HomeMy WebLinkAboutP_SEA_Bloom_Plan_Drawings_190422_v1.pdfAPPLICANT:
VERIZON WIRELESS
3245 158TH AVENUE SE
BELLEVUE, WA 98008
APPROVED BY
CONSTRUCTION MANAGER
DATE SIGNATURE
PROJECT MANAGER
SITE ACQUISITION
ZONING
APPROVAL / SIGN OFF
PROJECT CONTACT LIST
PROJECT INFORMATION
RF
REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO
EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED
DRIVING DIRECTIONS
ZONING CLASSIFICATION:
CODE INFORMATION:
IM (INDUSTRIAL-MEDIUM)
BUILDING CODE:IBC 2015
CONSTRUCTION TYPE:IIB
OCCUPANCY:U, S-2
JURISDICTION:CITY OF RENTON
PROPOSED BUILDING USE:UNMANNED TELECOM
LATITUDE:
SITE LOCATION (NAD83):
47° 27' 16.40" N
LONGITUDE:122° 13' 07.20" W
TOP OF STRUCTURE:79.00' AMSL
BASE OF STRUCTURE:19.10' AMSL
186 SF
PROJECT LEASE AREA:
125380-0015
PARCEL NUMBER:
2.26 ACRES
AREA OF PARCEL:
186 SF
NEW IMPERVIOUS AREA:
1.PARKING REQUIREMENTS ARE UNCHANGED.
2.TRAFFIC IS UNAFFECTED.
3.SIGNAGE IS UNAFFECTED.
GENERAL INFORMATION:
59.9' AGL
0.0' AGL
(47.454541° N)
(122.218667° W)
VICINITY MAP
NOT TO SCALE
GENERAL LOCATION MAP
NOT TO SCALE
TITLE SHEET
T-1.0
LANDLORD
2701 EAST VALLEY RD
RENTON, WA 98055
SEA BLOOM
DRAWING INDEX
DWG NO.DESCRIPTION
T-1.0 TITLE SHEET
SV-1.0 CIVIL SURVEY
A-1.0 SITE PLAN
A-2.0 ENLARGED SITE PLAN
A-3.0 ELEVATIONS
LDC, INC.
CONTACT: MICHAEL MERRITT,
PLS, CFedS
PHONE: (425) 806-1869
EMAIL: michaelm@ldccorp.com
PROJECT SURVEYOR:
PROJECT ARCHITECT:
LDC, INC.
CONTACT: RICHARD B. HALL, AIA
PHONE: (425) 806-1869
EMAIL: rhall@ldccorp.com
PROPERTY OWNER:
UTILITY COMPANIES
MICROWAVE
(ON SITE)
TELEPHONE:
TBD
POWER:
PROPRIETARY INFORMATION
DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY
ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY
ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS
DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION.
LDC TAKES NO RESPONSIBILITY FOR ADEQUACY OF
TOWER MOUNTS FOR EXISTING OR PROPOSED LOADING.
CONTRACTOR AND MOUNT MANUFACTURER TAKE FULL
RESPONSIBILITY FOR MOUNTING PRODUCTS USED &
THEIR ADEQUACY. MOUNTS SHOWN IN DRAWINGS ARE
FOR ILLUSTRATIVE PURPOSES ONLY.
DISCLAIMERS
THE INFORMATION CONTAINED IN THIS SET OF
CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE.
ANY USE OR DISCLOSURE OTHER THAN THAT WHICH
RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY
PROHIBITED.
PROJECT DESCRIPTION
VERIZON WIRELESS PROPOSES TO CONSTRUCT AN
UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF
59.9' MONOPOLE WITHIN A 35'-7"x5'-7" FENCED LEASE AREA.
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
18-801
SEA BLOOM
2701 EAST VALLEY RD
RENTON, WA 98055
7-30-18
RJG
RBH
1 7-30-18 PRELIMINARY ZONING RJG
2 8-3-18 RPZD: CLIENT COMMENTS ENS
3 1-14-19 FINAL ZONING ENS
4 1-28-19 RFZD: CLIENT COMMENTS ENS
APPROVAL STAMP
Survey ing
Eng ineer ing
Pla nning
AN N I V E R S ARYth15
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
SEE SV-1.0 FOR LEGAL DESCRIPTION
LEGAL DESCRIPTION
PROPERTY OWNER:
FROM VERIZON WIRELESS OFFICE:
·HEAD SOUTH ON 160TH AVE SE
·TURN LEFT ONTO SE EASTGATE WAY
·TURN RIGHT ONTO THE SEATTLE W/SEATTLE RAMP
·KEEP LEFT TO CONTINUE TOWARD I-90 W
·MERGE ONTO I-90 W/SEATTLE
·USE THE RIGHT 2 LANES TO TAKE EXIT 10 FOR INTERSTATE 405 S TOWARD RENTON
·MERGE ONTO I-405 S
·TAKE EXIT 2A TO MERGE ONTO WA-167 S TOWARD KENT/AUBURN
·PARTS OF THIS ROAD MAY BE CLOSED AT CERTAIN TIMES OR DAYS
·TAKE THE E VALLEY RD EXIT TOWARD SOUTHWEST 43RD STREET
·TURN RIGHT ONTO E RAINIER AVE S/E VALLEY RD
·DESTINATION WILL BE ON THE LEFT
2701 E VALLEY LLC.
2701 EAST VALLEY RD
RENTON, WA 98055
PROJECT CONSULTANT:
LDC, INC.
CONTACT: RICK CARDOZA
PHONE: (253) 218-9017
EMAIL: rcardoza@ldccorp.com
PROJECT
PROJECT
RECEIVED
05/08/2019
amorganroth
PLANNING DIVISION
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
VERIZON
SEA BLOOM
2701 E. VALLEY ROAD
RENTON, WA 98055
3-16-18
NSY
MRM
S urv ey i ng
E ngineer ing
P la nning
A N N IVE RS A RYth15
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
PROJECT
§§
§§
CIVIL SURVEY
SV-1.0RPLANOIS
SEFO ROYEVRUSDNALMICHAELR
M
RE T
ER OB
TIRT
Δ
1
PROPOSED QUANTITIES
POWER LENGTH:
N/A
FIBER/TELCO LENGTH:65'
ROAD LENGTH:N/A
UNDERGROUND:
OVERHEAD:488'
SITE PLAN
22"x34" SCALE: 1" = 30'11"x17" SCALE: 1" = 60'
PROPOSED VERIZON WIRELESS
LEASE AREA (35'-7"x 5'-7")
PROPOSED VERIZON WIRELESS
ANTENNA MOUNTED ON 59.9' MONOPOLE
EXISTING SITE ACCESS
SITE PLAN
A-1.0
1
A-2.0
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
18-801
SEA BLOOM
2701 EAST VALLEY RD
RENTON, WA 98055
7-30-18
RJG
RBH
1 7-30-18 PRELIMINARY ZONING RJG
2 8-3-18 RPZD: CLIENT COMMENTS ENS
3 1-14-19 FINAL ZONING ENS
4 1-28-19 RFZD: CLIENT COMMENTS ENS
APPROVAL STAMP
Survey ing
Eng ineer ing
Pla nning
AN N I V E R S ARYth15
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
ZONING MAP
NOT TO SCALE
PROJECT
IM CA
IL
ZONING:
IM (INDUSTRIAL-MEDIUM)
ADJACENT ZONING:
CA (COMMERCIAL ARTERIAL)
ADJACENT ZONING:
IL (INDUSTRIAL-LIGHT)
ADJACENT ZONING:
IM (INDUSTRIAL-MEDIUM)
23'
TOWER SETBACK
83'
TOWER SETBACK328' TOWER SETBACK198' TOWER SETBACK
EXISTING SITE ACCESS
ADJACENT ZONING:
IM (INDUSTRIAL-MEDIUM)
1ENLARGED SITE PLAN
22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0"
EXISTING SITE ACCESS
ENLARGED SITE PLAN
A-2.0
1
A-3.0
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
18-801
SEA BLOOM
2701 EAST VALLEY RD
RENTON, WA 98055
7-30-18
RJG
RBH
1 7-30-18 PRELIMINARY ZONING RJG
2 8-3-18 RPZD: CLIENT COMMENTS ENS
3 1-14-19 FINAL ZONING ENS
4 1-28-19 RFZD: CLIENT COMMENTS ENS
APPROVAL STAMP
Sur veying
E ngineer ing
Pl ann ing
AN N I V E R SARYth15
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
CONSTRUCTION PLAN KEYED NOTES
1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2.ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY
OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS HALOGEN SERVICE LIGHT, TYP
(2 TOTAL).
PROPOSED UNDERGROUND POWER & FIBER ROUTING.
PROPOSED VERIZON WIRELESS 6'-0" HIGH CHAIN LINK FENCE
W/ BARBED WIRE AND PRIVACY SLATS.
PROPOSED VERIZON WIRELESS CHAIN LINK ACCESS GATE W/ PRIVACY
SLATS AND LOCKING MECHANISM. VZW SIGNAGE MOUNTED TO GATE.
PROPOSED VERIZON WIRELESS HYBRID FIBER CABLE TO ANTENNAS
(2 TOTAL).
PROPOSED VERIZON WIRELESS EQUIPMENT CONCRETE PAD.
STRUCTURAL PENDING.
PROPOSED VERIZON WIRELESS T-ARM ANTENNA MOUNT.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 2 PER SECTOR, 8 TOTAL).
PROPOSED VERIZON WIRELESS MICROWAVE W/ MOUNT
(1 TOTAL).
PROPOSED VERIZON WIRELESS TELCO/FIBER CABINET.
PROPOSED VERIZON WIRELESS ILC CABINET.
EXISTING BOLLARD (TYP OF 4).
PROPOSED VERIZON WIRELESS RRUS 8843 UNIT
(TYP 1 PER SECTOR, 4 TOTAL).
PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP-12 BOX
(4 TOTAL, 2 @ ANTENNAS, 2 WITHIN CABINET).
PROPOSED 59.9' MONOPOLE. ENGINEERED BY OTHERS.
PROPOSED VERIZON WIRELESS 30KW
NATURAL GAS GENERATOR.
PROPOSED VERIZON WIRELESS WP METER/MAIN W/ METER
BASE AND DISCONNECT.
PROPOSED VERIZON WIRELESS UTILITY H-FRAME.
PROPOSED VERIZON WIRELESS BATTERY CABINET (1 TOTAL).
PROPOSED VERIZON WIRELESS LEASE AREA (35'-7"x 5'-7").
PROPOSED VERIZON WIRELESS (1) PDU/RF CABINETS WITH
(2) PRE-INSTALLED RAYCAP OVP-12 DEVICES.
PROPOSED VERIZON WIRELESS RRUS 4449 UNIT
(TYP 1 PER SECTOR, 4 TOTAL).
1
2
3
4
5
6
7
9
10
11
12
14
18
19
21
22
23
24
25
26
27
28
EXISTING PROPANE
TANK (TO REMAIN)
PROPOSED
VERIZON WIRELESS 5'-8"
FENCED LEASE AREA
& EQUIPMENT PAD
EXISTING 16'-8" TRASH ENCLOSURE128'-2"11'-5"PROPOSED VERIZON WIRELESS 35'-8"
FENCED LEASE AREA & EQUIPMENT PAD92827
24
2
21
22
19
25
23
14
12
5
7
3
11
6
4
EXISTING TREE (TYP
OF 3 TO REMAIN)
EXISTING CHAIN LINK
FENCE (TO REMAIN)EXISTING 15'-0"CITY WATERLINE EASEMENTEXISTING 18'-0" TRASH ENCLOSURE
SECTOR 3 : 220°SECTOR 1 : 35°MW
:
68°
SE
C
T
O
R
2
:
12
0
°
PROPOSED 7'-6"
UTILITY H-FRAME
1'-7"
26
SE
C
T
O
R
4
:
30
0
°EXISTING 15'-0"CITY WATERLINE EASEMENT1 9
10
10
18
PROPOSED 12'
ROLLING GATE
1
PROPOSED VERIZON WIRELESS 35'-8"
FENCED LEASE AREA & EQUIPMENT PAD
PROPOSED NORTH ELEVATION (LOOKING SOUTH)
22"x34" SCALE: 1/4" = 1'-0"11"x17" SCALE: 1/8" = 1'-0"
TOP OF EXISTING MONOPOLE
59.9' AGL
TIP HEIGHT OF PROPOSED
VERIZON WIRELESS ANTENNAS
59.9' AGL
FINISH GRADE
0.0' AGL
ELEVATIONS
A-3.0
RICHARD B. HALL
STATE OF WASHINGTON
8828 REGISTERED
ARCHITECT
SHEET NUMBER
SUBMITTALS
DATE:
DRAWN BY:
CHECKED BY:
SITE
DESCRIPTION BYDATE
SHEET TITLE
REV
18-801
SEA BLOOM
2701 EAST VALLEY RD
RENTON, WA 98055
7-30-18
RJG
RBH
1 7-30-18 PRELIMINARY ZONING RJG
2 8-3-18 RPZD: CLIENT COMMENTS ENS
3 1-14-19 FINAL ZONING ENS
4 1-28-19 RFZD: CLIENT COMMENTS ENS
APPROVAL STAMP
Survey ing
Eng ineer ing
Pla nning
AN N I V E R S ARYth15
www.LDCcorp.com
20210 142nd Avenue NE
Woodinville, WA 98072 Fx. 425.482.2893
Ph. 425.806.1869
CONSTRUCTION PLAN KEYED NOTES
1.VERIFY ANTENNA MODEL, TIP HEIGHT & AZIMUTHS.
2.ANALYSIS OF TOWER & FOUNDATION SHALL BE PERFORMED BY
OTHERS & STAMPED BY A LICENSED STRUCTURAL ENGINEER.
SITE NOTES
PROPOSED VERIZON WIRELESS 6'-0" HIGH CHAIN LINK FENCE
W/ BARBED WIRE AND PRIVACY SLATS.
PROPOSED VERIZON WIRELESS CHAIN LINK ACCESS GATE W/ PRIVACY
SLATS AND LOCKING MECHANISM. VZW SIGNAGE MOUNTED TO GATE.
PROPOSED VERIZON WIRELESS HYBRID FIBER CABLE TO ANTENNAS
(2 TOTAL).
PROPOSED VERIZON WIRELESS EQUIPMENT CONCRETE PAD.
STRUCTURAL PENDING.
PROPOSED VERIZON WIRELESS T-ARM ANTENNA MOUNT.
PROPOSED VERIZON WIRELESS PANEL ANTENNA
(TYP 2 PER SECTOR, 8 TOTAL).
PROPOSED VERIZON WIRELESS MICROWAVE W/ MOUNT
(1 TOTAL).
EXISTING BOLLARD (TYP OF 4).
PROPOSED VERIZON WIRELESS RRUS 8843 UNIT
(TYP 1 PER SECTOR, 4 TOTAL).
PROPOSED VERIZON WIRELESS RAYCAP DISTRIBUTION OVP-12 BOX
(4 TOTAL, 2 @ ANTENNAS, 2 WITHIN CABINET).
PROPOSED 59.9' MONOPOLE. ENGINEERED BY OTHERS.
PROPOSED VERIZON WIRELESS 30KW
NATURAL GAS GENERATOR.
PROPOSED VERIZON WIRELESS BATTERY CABINET (1 TOTAL).
PROPOSED VERIZON WIRELESS LEASE AREA (35'-7"x 5'-7").
PROPOSED VERIZON WIRELESS (1) PDU/RF CABINETS WITH
(2) PRE-INSTALLED RAYCAP OVP-12 DEVICES.
PROPOSED VERIZON WIRELESS RRUS 4449 UNIT
(TYP 1 PER SECTOR, 4 TOTAL).
1
2
3
4
5
6
7
9
10
11
12
14
18
24
27
28
RAD CENTER OF PROPOSED
VERIZON WIRELESS ANTENNAS
43.0' AGL
EXISTING 18'-0" TRASH ENCLOSURE9
24
14
28 27
4
11
12
7
3
6
5
10
18
21
EXISTING ADJACENT
BUILDING (TO REMAIN)
PROPOSED 12'
ROLLING GATE