Loading...
HomeMy WebLinkAboutP_Exterior_Elevations_and_Floor_Plans_Lot_4_190607_v1© SQUARE FOOTAGE PLAN L410 "A" BASEMENT FLOOR AREA 753 SQ. FT. FIRST FLOOR AREA 1578 SQ. FT. SECOND FLOOR AREA 1846 SQ. FT. TOTAL AREA 4177 SQ. FT. GARAGE AREA (2-BAY)419 SQ. FT. GARAGE AREA (1-BAY)212 SQ. FT. PORCH AREA 83 SQ. FT. PATIO 382 SQ. FT. COVERED BALCONY 162 SQ. FT. BA. 5 9'-0" CLG. H.S. REC. ROOM 9'-0" CLG. CARPET BDRM. 5 9'-0" CLG. CARPET PATIO CONC. CRAWL SPACE 45'-0" 15'-11"15'-0"14'-1" 12'-1"8" 4'-2"10'-1"8"75'-0"21'-312"4'-512"4'-0"9'-5"22'-0"13'-10"8"3'-912"8"3'-4"8"8'-9"8"12"21'-312"45'-0" 11'-41 2"6'-7"6'-41 2"20'-8" 8" 1 2"10'-8"8"5'-11"8"5'-81 2"8"19'-4"8" 21'-61 2"1 2"8"10'-01 2"8"75'-0"21'-312"28'-812"11'-2"1'-7"1'-7"13'-10"8"18'-9"8"7'-1112"8"17'-212"8"12"10"12'-91 2"18'-11 2"3'-8" 9'-10"2'-111 2"5'-2"2'-51 2"8'-812"2'-512"5'-312"2'-8"VARIES7'-11"4'-2"2'-5"2'-9"112"16'-0"5060 FG3060 FG3060 FG(TEMP)12'-612"1'-312"812"7"8"2 0 ' - 5 1 2" 3060 CSMT. A A1-B4-0 A A1-B4-0 B A1-B4-0 B A1-B4-0 5'-3" 8"4" 1'-4" 11'-81 2"2'-41 2" 8'-5" 5'-3"(TEMP)FRENCH DOORS(TEMP)PAIR 308030'-11"VARIES1'-912"3060 CSMT.OPT. 36"x36"AC PADE C A1-A4-0 PARTIAL 2480 H.C.60"x34" SHOWERPER SPECS.OPT. WET BAR OPT. UNDER CAB. REFRIG. AT OPT. WET BAR UP 17R. TB TP 2680 H.C. R&S 5080 BI-PASS CPTHS 2480 H.C.17'-8"6'-8"3'-8"3'-61 2" 10'-51 2"7'-21 2"2'-5"7" 8" 1 2" 8" 42" HIGH CONCRETE STEM WALL - WRAP SIDING TO INSIDE CORNER 812"12'-512"8"7"15'-812"4'-1"1'-6"7"STEPPED FOUNDATION -VARIES PER SITEREFER TO CIVIL PLANSSTEPPED FOUNDATION - VARIES PER SITEREFER TO CIVIL PLANSLINEN #13'-7"11"1'-912"SHELF -4" BELOW SILL CRAWL SPACE VENTS PRE-FAB NICHE ©1.PROVIDE COMBUSTION AIR PER MANUFACTURERS RECOMMENDATIONS 2.INSTALL TEMPERATURE & PRESSURE RELIEF VALVE SOFFIT SYMBOLS FLAT SOFFIT W/ TOP @ 8'-2 12" A.F.F. @ 9'-0" PL. NOTE: SOFFITS AT OPTIONAL 8'-0" DOOR ARE AT 8'-6". WATER HEATER NOTE LAUNDRY ROOM NOTES 1.GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH IRC SECTION R308.3 2.GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE WORD 'TEMPERED' OR 'TEMP' OR 1.NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL (EACH SLEEPING ROOM SHALL HAVE AT LEAST ONE) SHALL BE DESIGNATED FOR EMERGENCY EGRESS & RESCUE. 2.ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF 5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHES HIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS 3.ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONAL FROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS. E 1.UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION, DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90 DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO 2.PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS 3.WASHER SPACE, PROVIDE RECESSED WATER AND WASTE 4.AT 2ND FLOOR, PROVIDE OPT. "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE 5.FLIP WASHER/DRYER ON REVERSE PLANS - WASHER TO ALWAYS BE ON THE LEFT DRYER VENT TO OUTSIDE AIR GLAZING & WINDOW NOTES EMERGENCY BEDROOM EGRESS AND RESCUE SAFETY GLAZING 1.ALL GLAZING SHALL COMPLY WITH IRC SECTION R308 2.ALL GLAZING SHALL BE IN COMPLIANCE WITH WASHINGTON STATE ENERGY CODE SEC R303.1.3. 3.WINDOW CALLOUTS ARE AS FOLLOWS: SGD = SLIDER SH = SINGLE HUNG DH = DOUBLE HUNG FX = FIXED GLASS CA = CASEMENT 1.WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH IRC SECTION R308.4. 2.IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED WINDOW FALL PROTECTION T BATH AND SHOWER SPACES BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (IRC SEC R307.2) DV BASEMENT FLOOR PLAN "A" 1/4" = 1'-0" 8'-0"8'-0" ALL EXTERIOR DOORS AND WINDOWS TO HAVE HEADER HEIGHT AS LISTED BELOW U.N.O.: (SEE ELEVATIONS) HEADER HEIGHTS FIRST FLOOR:SECOND FLOOR 8'-0" BASEMENT FLOOR: 2x4 STUD WALL WALL LEGEND 2x6 STUD WALL (2) 2x4 STUD WALL 2x8 STUD WALL SQUARE FOOTAGE PLAN L410 "A" BASEMENT FLOOR AREA 753 SQ. FT. FIRST FLOOR AREA 1578 SQ. FT. SECOND FLOOR AREA 1846 SQ. FT. TOTAL AREA 4177 SQ. FT. GARAGE AREA (2-BAY)419 SQ. FT. GARAGE AREA (1-BAY)212 SQ. FT. PORCH AREA 83 SQ. FT. PATIO 382 SQ. FT. COVERED BALCONY 162 SQ. FT.55'-0"18'-1"8080 SECTIONAL GARAGE DOOR 16080 SECTIONAL GARAGE DOOR45'-0" 15'-11"15'-0"1'-4"12'-9" 8'-21 2"4'-61 2" 7'-1"5'-6"3'-4"2'-01 2"3'-6"3'-6"3'-6"2'-51 2"75'-0"1'-7"2'-0"3'-912"2 0 ' - 5 1 2"1'-0"49'-0"6'-9"4'-5"13'-10"20'-312"11'-3"3'-10"5'-312"8'-4"5'-10"5'-5"1'-1112"2'-512"6'-1012"6'-1112"45'-0" 11'-8"12'-8" 15'-41 2"5'-31 2" 1'-81 2"8'-3"1'-81 2" 5'-6"7'-1"2'-91 2" 1'-91 2"3'-6"1'-91 2" 6'-31 2"3'-9"2'-71 2"20'-8" 9'-7"11'-1" 1'-111 2"4'-4"1'-111 2"1'-91 2"1'-312"3'-512"1'-0"4'-0"2'-012"1'-1112"1'-5"2'-012"75'-0"1'-7"20'-0"1'-0"1'-8"16'-3"1'-1"1'-312"13'-1012"21'-9"2'-612"8'-4"3'-0"7"6'-1"11'-4"2'-812"1'-2"8'-712"15'-11"5'-81 2"3" 1'-2" 5'-111 2"5'-11"10'-51 2"5'-10" 3'-10" 4'-4"7'-7"4'-6"7'-5"7"15'-2"4'-712"8'-6"1'-0"6'-5" 4'-3"7"3'-1"2'-41 2"5'-01 2"11'-612"3"2'-9"3"5'-7"4'-1"4'-3"5060 SL3060 FG3060 FG3060 FG3060 FG2480 H.C.4050 SL12080 SGDCENTER-MEET(TEMP)3060 CSMT. 2660 FG 2660 FG 3080 S.C.3060 SH o/ 3016 FG 3060 SH o/3016 FG2040 SH 3060 SH 3060 SH SINK w/ DISPOSAL D.W. VERIFY DIM. w/ MANUF. LINE OF UPPER CABINETS ISLAND w/ EATING BAR 34 12" LOW WALL 36" REFRIG. SPACE LINE OF UPPER CABINETS PANTRY w/ (4) SHELVES 2480 H.C. FIREPLACE PER SPECS. OPEN RAIL TP 60"x34" SHOWERPER SPECS.R&SR&S 2480 H.C.2680 H.C.2880x13 8" SC TIGHT FITTING SELF CLOSING CPTHSGREAT ROOM VOL. CLG. H.S. NOOK 9'-0" CLG. H.S. KITCHEN 9'-0" CLG. H.S. BALCONY W.P. DECKING PAN. 9'-0" CLG. H.S. BA. 1 9'-0" CLG. H.S. STUDY 9'-0" CLG. CARPET VALET 9'-0" CLG. H.S. FOYER 9'-0" CLG. H.S.HALL 9'-0" CLG. H.S. 2-BAY GARAGE CONC. 1-BAY GARAGE CONC. PORCH CONC. GUEST BDRM. 9'-0" CLG. CARPET5060 SL2'-41 4"2'-21 4"3060 FG(TEMP)B A1-A4-0 A A1-A4-0 A A1-A4-0 B A1-A4-0 E DN. 17R.5'-0"16'-6"7"91 2"1'-012"10'-312"10'-6"9'-912"4050 FG 18"x24" CRAWL SPACE ACCESS PANEL - CARPET TB PRE-FAB NICHE 2'-6"2'-912"5020 FG C A1-A4-0 PARTIAL OBSCURED H.H. AT PLATE A 2880x13 8" SC TIGHT FITTING SELF CLOSING 36" GAS APPLIANCE w/ HOOD ABOVE OPT. 48" RANGE 33" MICRO./ OVEN COMBO18'-6"3'-3"2646 FG UP. 17R. 1'-4"4'-3"1"6'-8"4'-4"R&S2480 H.C.STD. BENCHOPT. 18" WINE FRIDGE OR 30/30 FRIDGE/FRZ OPT. UTIL. SINK TANKLESS WATER HEATER 95% EFFECIENT 7"4" MDF SHELF/CAP +42" ABOVE F.F. WRAP TILE/STONE FIREPLACE SURROUND PER FLOOR PLAN WIDTH A 4" MDF SHELF/CAP +42" ABOVE F.F.4'-0"PAINTED PR PRE-STAINED BOX FRAMED MANTEL RETURN MATERIAL TO EXTERIOR WALL, 5" ADDITIONAL WRAP ©1.PROVIDE COMBUSTION AIR PER MANUFACTURERS RECOMMENDATIONS 2.INSTALL TEMPERATURE & PRESSURE RELIEF VALVE SOFFIT SYMBOLS FLAT SOFFIT W/ TOP @ 8'-2 12" A.F.F. @ 9'-0" PL. NOTE: SOFFITS AT OPTIONAL 8'-0" DOOR ARE AT 8'-6". WATER HEATER NOTE LAUNDRY ROOM NOTES 1.GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH IRC SECTION R308.3 2.GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE WORD 'TEMPERED' OR 'TEMP' OR 1.NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL (EACH SLEEPING ROOM SHALL HAVE AT LEAST ONE) SHALL BE DESIGNATED FOR EMERGENCY EGRESS & RESCUE. 2.ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF 5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHES HIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS 3.ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONAL FROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS. E 1.UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION, DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90 DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO 2.PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS 3.WASHER SPACE, PROVIDE RECESSED WATER AND WASTE 4.AT 2ND FLOOR, PROVIDE OPT. "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE 5.FLIP WASHER/DRYER ON REVERSE PLANS - WASHER TO ALWAYS BE ON THE LEFT DRYER VENT TO OUTSIDE AIR GLAZING & WINDOW NOTES EMERGENCY BEDROOM EGRESS AND RESCUE SAFETY GLAZING 1.ALL GLAZING SHALL COMPLY WITH IRC SECTION R308 2.ALL GLAZING SHALL BE IN COMPLIANCE WITH WASHINGTON STATE ENERGY CODE SEC R303.1.3. 3.WINDOW CALLOUTS ARE AS FOLLOWS: SGD = SLIDER SH = SINGLE HUNG DH = DOUBLE HUNG FX = FIXED GLASS CA = CASEMENT 1.WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH IRC SECTION R308.4. 2.IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED WINDOW FALL PROTECTION T BATH AND SHOWER SPACES BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (IRC SEC R307.2) DV FIRST FLOOR PLAN "A" 1/4" = 1'-0" 8'-0"8'-0" ALL EXTERIOR DOORS AND WINDOWS TO HAVE HEADER HEIGHT AS LISTED BELOW U.N.O.: (SEE ELEVATIONS) HEADER HEIGHTS FIRST FLOOR:SECOND FLOOR 8'-0" BASEMENT FLOOR: 2x4 STUD WALL WALL LEGEND 2x6 STUD WALL (2) 2x4 STUD WALL 2x8 STUD WALL SQUARE FOOTAGE PLAN L410 "A" BASEMENT FLOOR AREA 753 SQ. FT. FIRST FLOOR AREA 1578 SQ. FT. SECOND FLOOR AREA 1846 SQ. FT. TOTAL AREA 4177 SQ. FT. GARAGE AREA (2-BAY)419 SQ. FT. GARAGE AREA (1-BAY)212 SQ. FT. PORCH AREA 83 SQ. FT. PATIO 382 SQ. FT. COVERED BALCONY 162 SQ. FT. M. BA. 9'-0" CLG. H.S. MASTER BEDROOM 9'-0" CLG. CARPET HALL 9'-0" CLG. CARPET LAUN. 9'-0" CLG. H.S.BDRM. 2 9'-0" CLG. CARPET LOFT 9'-0" CLG. CARPET BELOW OPEN TO BA. 2 9'-0" CLG. H.S. BDRM. 3 9'-0" CLG. CARPET W.I.C. 9'-0" CLG. CARPET SHARED BATH 9'-0" CLG. H.S. BDRM. 4 9'-0" CLG. CARPET 45'-0"1'-6" 15'-11"15'-0"14'-1"75'-0"20'-0"26'-412"10'-0"18'-712"21'-012"5'-4"11'-0"3'-0"3'-312"3'-712"14'-912"24'-9"1'-0"4'-0"2'-8"7'-312"3'-1112"8'-012"2'-912"5'-1012"1'-5"45'-0"1'-6" 11'-8"12'-8"15'-41 2"5'-31 2" 6'-31 2"3'-9"2'-71 2" 1'-111 2"1'-1112"2'-012"4'-4"1'-111 2"1'-91 2" 2'-4"9'-71 2"3'-91 2"15'-2" 4'-51 2"2'-111 2"4'-3"4'-1"2'-8"11'-8"4'-61 2"75'-0"49'-0"11'-2"13'-10"6'-3"7'-612"11'-5"15'-512"8'-4"1'-812"3'-6"3'-6"2'-512"2'-012"8'-912"3'-0"2'-4"3'-6"2'-6"5'-1014"5'-634"1'-812"2'-9"1'-912"1'-31 2"2'-10"4'-101 2"3'-61 2"2'-8" 5'-51 2" 12'-11 2"3"2'-9"3"11'-8"8'-9"3'-412"2'-8"2'-8"8'-2"7"11'-8"3'-912"4'-1"4'-3"2'-01 2"2'-01 2"14'-81 2"4'-2"3'-912"19'-6"17'-012"4'-0"3040 SH3060 SH o/ 3016 FG 3060 SH o/ 3016 FG 2040 SH (TEMP) 3060 FG 3060 FG 3060 SH 4020 FG3060 FG o/7'-1"3'-4"2'-01 2"3'-6"3'-6"3'-6"2'-51 2"4'-83 4"3'-6"3'-6"2'-41 4"3060 FG3060 FG3060 FG3060 FG3060 FG3060 FG5060 SL2626 FG 5050 FG 2050 FG 2020 FG 2020 FG 3060 FG 3050 FG 3050 FG 3050 FG 3060 FG 3060 FG 7'-31 2"3'-6"4'-7" 3060 SH 2'-4"2'-111 2" 66"x36" FREE STANDING TUB - PER SPECS 97.5"x48" SHOWER PER SPECS.SHOWERSEATR&SR&S R&SOPT. SINK2880 H.C.2680 S.C.NOTE: INSULATE F.A.U. ENCLOSURE WALLS 95% EFFICIENT 2480 H.C. CPTHS CPTHSOPEN RAIL 14 D2 R&S5080 BI-PASS60"x34" SHOWER PER SPECS.CPTHS2480 H.C.CPTHS2480 H.C.R&S 5080 BI-PASS 2680 H.C. 60"x32" TUB PER SPECS - OPT. 60"x34" SHOWER PER SPECS.2480 H.C.CPT HS 2480 H.C.R&S5080 BI-PASS2680 H.C.2080 H.C.2880 H.C.2680 H.C. 5'-6"5060 SL3040 FGB A1-B4-0 A A1-B4-0 A A1-B4-0 B A1-B4-0 (TEMP)2'-1"16'-612"LINE w/ (4) SHELVES 3'-1"6'-11"3'-2"6'-112"2'-312"2'-7"6'-5"3'-91 2"7'-101 2" 3060 FG 2'-612"2626 FG E E E TP TB TB TB TP CPTHS 5050 SL E 10'-41 2"7'-1012"7'-7"9056 X0X 1'-0"5'-10"4'-4" DN. 17R. C A1-A4-0 PARTIAL 2 4 8 0 H .C .2680 H.C.2480 H.C.CPTHSOPT. 3080 BARN DOOR STANDARD SHELF OPT. UPPER CABS. 4'-0"7'-8"2050 FGPRE-FAB NICHE PRE-FAB NICHE PRE-FAB NICHELINENOPEN RAIL ©1.PROVIDE COMBUSTION AIR PER MANUFACTURERS RECOMMENDATIONS 2.INSTALL TEMPERATURE & PRESSURE RELIEF VALVE SOFFIT SYMBOLS FLAT SOFFIT W/ TOP @ 8'-2 12" A.F.F. @ 9'-0" PL. NOTE: SOFFITS AT OPTIONAL 8'-0" DOOR ARE AT 8'-6". WATER HEATER NOTE LAUNDRY ROOM NOTES 1.GLAZING SUBJECT TO HUMAN IMPACT SHALL COMPLY WITH IRC SECTION R308.3 2.GLAZED PANELS REQUIRING SAFETY GLAZING SHALL BE IDENTIFIED WITH THE WORD 'TEMPERED' OR 'TEMP' OR 1.NOTE: EXTERIOR WINDOWS LABELED W/ AN SYMBOL (EACH SLEEPING ROOM SHALL HAVE AT LEAST ONE) SHALL BE DESIGNATED FOR EMERGENCY EGRESS & RESCUE. 2.ESCAPE & RESCUE WINDOWS SHALL HAVE A MIN. NET CLEAR OPENABLE AREA OF 5.7 SQ. FT. THE MIN. NET CLEAR OPENING SHALL BE NOT LESS THAN 24 INCHES HIGH AND 20 INCHES WIDE. WHEN WINDOWS ARE PROVIDED AS A MEANS OF ESCAPE OR RESCUE, THEY SHALL HAVE THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES MEASURED FROM THE FLOOR. THESE WINDOWS 3.ANY BARS, GRILLS GRATES OR OTHER SIMILAR DEVICES SHALL BE OPERATIONAL FROM THE INSIDE OF ROOM WITHOUT THE USE OF KEYS OR TOOLS. E 1.UNLESS OTHERWISE PERMITTED OR REQUIRED BY THE DRYER MANUFACTURER'S INSTRUCTIONS AND APPROVED BY THE AUTHORITY HAVING JURISDICTION, DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET, INCLUDING TWO 90 DEGREE ELBOWS. A LENGTH OF 2 FEET SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO 2.PROVIDE 100 SQUARE INCHES OF MAKE-UP AIR TO ALL LAUNDRY ROOMS 3.WASHER SPACE, PROVIDE RECESSED WATER AND WASTE 4.AT 2ND FLOOR, PROVIDE OPT. "SMITTY" PAN UNDER WASHER WITH DRAIN TO OUTSIDE 5.FLIP WASHER/DRYER ON REVERSE PLANS - WASHER TO ALWAYS BE ON THE LEFT DRYER VENT TO OUTSIDE AIR GLAZING & WINDOW NOTES EMERGENCY BEDROOM EGRESS AND RESCUE SAFETY GLAZING 1.ALL GLAZING SHALL COMPLY WITH IRC SECTION R308 2.ALL GLAZING SHALL BE IN COMPLIANCE WITH WASHINGTON STATE ENERGY CODE SEC R303.1.3. 3.WINDOW CALLOUTS ARE AS FOLLOWS: SGD = SLIDER SH = SINGLE HUNG DH = DOUBLE HUNG FX = FIXED GLASS CA = CASEMENT 1.WINDOW FALL PROTECTION SHALL BE PROVIDED IN ACCORDANCE WITH IRC SECTION R308.4. 2.IN DWELLING UNITS, WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED WINDOW FALL PROTECTION T BATH AND SHOWER SPACES BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. (IRC SEC R307.2) DV SECOND FLOOR PLAN "A" 1/4" = 1'-0" 8'-0"8'-0" ALL EXTERIOR DOORS AND WINDOWS TO HAVE HEADER HEIGHT AS LISTED BELOW U.N.O.: (SEE ELEVATIONS) HEADER HEIGHTS FIRST FLOOR:SECOND FLOOR 8'-0" BASEMENT FLOOR: 2x4 STUD WALL WALL LEGEND 2x6 STUD WALL (2) 2x4 STUD WALL 2x8 STUD WALL FLOOR FRAMING SYSTEM - REFER TO STRUCTURAL 9'-118"9'-118"9'-118"GREAT ROOM F.F. T.O.P. T.O.P.1'-058"F.F. T.O.P.1'-334"HALL HALL M. BA.STAIR WELL REC. ROOM BA.5 FOUNDATION SYSTEM - REFER TO FOUNDATION PLAN GRADE GRADE FLOOR FRAMING SYSTEM - REFER TO STRUCTURAL KITCHEN R-21 INSULATION 2" CONTINUOUS RIGID FOAM INSULATION 2x4 FLAT FRAME R-21 INSULATION 2x4 WALL HALL R-49 INSULATION (2)2x8 FRAMING AT 16" O.C. AT LANDINGS (2)2x8 FRAMING AT 16" O.C. AT LANDINGS GRADE F.F. T.O.P. T.O.P. F.F. T.O.P.9'-118"9'-118"9'-118"FOUNDATION SYSTEM - REFER TO FOUNDATION PLAN REC. ROOM FLOOR FRAMING SYSTEM - REFER TO STRUCTURAL PRE-MANUFACTURED ROOF TRUSSES - REFER TO ROOF FRAMING PLAN 12 4 PATIO GREAT ROOMNOOK FOYER PORCH 4'-0" PROVIDE R-10 RIGID INSULATION UNDER SLAB. CONTINUE TO TOP OF SLAB PER OPTION 1A TABLE 406.2 4'-0" R-21 INSULATION R-49 INSULATION MASTER BEDROOM LAUNDRYHALL GRADE F.F. T.O.P. F.F. T.O.P.9'-118"9'-118"1'-058"F.F. T.O.P.9'-118"1'-334"STAIR WELL R-21 INSULATION R-21 INSULATION 2" CONTINUOUS RIGID FOAM INSULATION 2x4 FLAT FRAME 2x6 WALL 2x4 WALL (2)2x8 FRAMING AT 16" O.C. AT LANDINGS (2)2x8 FRAMING AT 16" O.C. AT LANDINGS SILL SEALANT RIM INSULATION PRESSURE TREATED MUD SILL CONCRETE FOUNDATION WALL DAMP PROOFING 4" CONCRETE SLAB SLAB BASE (2" SAND)* MOISTURE BARRIER COMPACTED EARTH *GOOD PRACTICE: REQUIRED ONLY IN HIGHER RISK RADON COUNTIES HEATED BASEMENT 4" GRAVEL BASE* 3/8"-3/4" SCREENED WITH FINES REMOVED R-VALUE BASED ON COMPLIANCE PATH SILL SEAL AND CAPILLARY BREAK ("GOOD PRACTICE")©PROVIDE 1/2" MINIMUM CLEARANCE BETWEEN TOP PLATE OF INTERIOR PARTITIONS AND BOTTOM CHORD OF TRUSSES (TO INSURE LOADING WILL BE AS DESIGNED) PROVIDE FIRE STOPS AT THE FOLLOWING LOCATIONS A.IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AT THE CEILING AND FLOOR LEVELS, AND AT 10'-0" INTERVALS ALONG THE LENGTH OF THE WALL. B.AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERT. AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS. C.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIR ARE UNFINISHED. D.IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND SIMILAR OPENINGS WHICH AFFORD A PASSAGE FOR FIRE AT CEILING AND FLOOR LEVELS WITH NONCOMBUSTIBLE MATERIALS. SECTION NOTES THE MAXIMUM RISER HEIGHT SHALL BE 7 3/4" AND THE MINIMUM TREAD DEPTH SHALL BE 10". THE RISER HEIGHT IS TO BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF THE ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. STAIR TREADS AND RISERS ACCESSIBLE AREAS UNDER STAIRS PROVIDE A MINIMUM OF 1/2" GYPSUM BOARD AT ENCLOSED SIDE OF ACCESSIBLE SPACE UNDER STAIRS PER IRC SECTION R302.7 DUCTS IN THE GARAGE PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF MINIMUM NO. 26 GAUGE SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE PER IRC SECTION R302.5 DWELLING/GARAGE SEPARATION SEPARATION MATERIAL FROM THE RESIDENCE AND ATTICS NOT LESS THAN 1 2" GYP BOARD OR EQUAL ON THE GARAGE SIDE FROM ALL HABITABLE ROOMS ABOVE THE GARAGE OR CARPORT NOT LESS THAN 5 8" TYPE X GYP BOARD OR EQUIVALENT STRUCTURES SUPPORTING FLOOR / CEILING ASSEMBLIES USED FOR SEPARATION REQUIRED BY THIS SECTION NOT LESS THAN 1 2" GYP BOARD OR EQUIVALENT WALLS (2X4) : WALLS (2X6) : FLOOR (O/ GARAGE) : FLOOR (EXT.) : ROOF (TRUSS) : ROOF (RAFTER) : WSEC INSULATION VALUES R-15 R-21 R-30 R-30 R-49 R-38 BUILDING SECTION "A" 1/4" = 1'-0" BUILDING SECTION "B" 1/4" = 1'-0" PARTIAL BUILDING SECTION "C" 1/4" = 1'-0" TYPICAL WALL SECTION 1/2" = 1'-0" 8'-0" HDR. HGT. TYP.9'-118"9'-118"T.O.S. F.F. T.O.P. T.O.P.8'-0" HDR. HGT. TYP.6 D1 2 D3 HORIZONTAL SIDING 8" REVEAL STACK BOND BRICK HORIZONTAL SIDING 4" REVEAL 2x4 CORNER BOARD-TYP. 1x4 WOOD TRIM STONE CAP 4x6 WOOD TRIM 2x4 WOOD TRIM METAL CAP 2x4 WOOD TRIM7 D6 11 D6 2B D6 1 D6 6 D6 GARAGE BUMPOUTS A1-A2-1 9'-118"9'-118"F.F. F.F. T.O.P. T.O.P.9'-118"T.O.S. T.O.P.8'-0" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.GLASS PANEL RAILING WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 1368 S.F. AREA OF WINDOWS 462 S.F. WINDOW PERCENTAGE 33.8% 1 D6 6 D6 11 D6 2 D6 2 D3 STACK BOND BRICK 2x2 WOOD TRIM HORIZONTAL SIDING 8" REVEAL 2x4 WOOD TRIM 2x4 WOOD TRIM 2x4 WOOD TRIM 2x4 WOOD TRIM 2x4 CORNER BOARD-TYP. METAL CAP 13 D6 4:12 SLOPE 2%2.5:124:12 V A L L E Y RIDGE SLOPE 2%VALLEYVALL E Y 2.5:12S LO P E 2%2.5:12SLOPE 2% CRICKETVALLEYSLOPE 2%4:121'-6" 1'-0"1'-0"1'-6" 2'-0"1'-0"1'-0"1'-6"1'-6" 1'-6"1'-6"12 D1 6'-5"ROOF JACKS AREA 1 Ø ©1.THE CONTRACTOR RESPONSIBLE FOR FABRICATION & INSTALLATION OF GUTTERS & DOWNSPOUTS SHALL SUBMIT SHOP DRAWINGS CONSISTING OF ROOF PLANS, ELEVATIONS & DETAILS OUTLINING THE ENTIRE GUTTER & DOWNSPOUT SYSTEM TO THE BUILDER/CONTRACTOR FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 2.DOWNSPOUTS SHALL BE TIED INTO AREA DRAINS, SEE PRECISE GRADING PLAN. 3.ALL DOWNSPOUTS SHALL BE HIDDEN TO THE BEST EXTENT POSSIBLE. 4.THE TRUSS MANUFACTURER SHALL ALLOW FOR SERVICE ACCESS TO THE ATTIC MOUNTED FORCED AIR UNITS, (WHERE APPLICABLE) 5.THE MINIMUM NET FREE VENTILATING AREA SHALL BE 1/150 OF THE AREA OF THE VENTED SPACE. EXCEPTION: THE MINIMUM NET FREE VENTILATION AREA SHALL BE 1/300 OF THE VENTED SPACE PROVIDED ONE OR MORE OF THE FOLLOWING CONDITIONS ARE MET: 1.IN CLIMATE ZONES 6, 7 AND 8, A CLASS I OR II VAPOR RETARDER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING 2.AT LEAST 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE ATTIC OR RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED NO MORE THAN 3 FEET BELOW THE RIDGE OR THE HIGHEST POINT OF THE SPACE, MEASURED VERTICALLY, WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. WHERE THE LOCATION OF WALL OR ROOF FRAMING MEMBERS CONFLICTS WITH THE INSTALLATION OF UPPER VENTILATORS, INSTALLATION MORE THAN 3 FEET BELOW THE RIDGE OR HIGHEST POINT OF THE SPACE SHALL BE PERMITTED. R806.2 2012 INTERNATIONAL RESIDENTIAL CODE ROOF PLAN NOTES 1.SEE SHEET A1 FOR ALL GENERAL NOTES AND REQUIREMENTS. 2.SEE SHEET A1 FOR TYPICAL BUILDING MATERIALS. 3.PROVIDE DOUBLE UNDERLAYMENT FOR ROOF PITCH FROM 2:12 UP TO (BUT NOT INCLUDING) 4:12. 4.TRUSS DESIGN BY MANUFACTURER. TRUSS PLAN AND FLOOR FRAMING DESIGN BY MANUFACTURER. FRAMING PLANS SHOWN ARE FOR GENERAL LAYOUT ONLY (SEE SHEET A1: SUMMARY 7) - TRUSS LOADING (SEE SHEET A1: SUMMARY 3-2) - TRUSS SPAN PER FLOOR FRAMING PLANS - TRUSS TYPE PER ROOF FRAMING PLAN 5.ROOF FRAMING SPACING, 24" O.C. U.O.N. 6.ROOF PITCH - EXTERIOR PER ELEVATION - INTERIOR PER SECTION. 7.ALL EXTERIOR WALLS ARE P1-6 TYPICAL U.O.N. 8.ROOF TAIL AND RAKE OVERHANG PER ROOF PLAN. 9.SEE 'S' SHEETS FOR SHEARWALL SCHEDULE, NOTES AND LATERAL DETAILS. 10.PLANS TO GOVERN FURNACE LOCATION. GENERAL FRAMING NOTES FRONT ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY REAR ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY ROOF PLAN "A" 1/8" = 1/-0" N. 39th CT. (EAST) LAKE WA. BLVD. N (WEST) T.O.S. F.F. T.O.P. T.O.P. T.O.S.9'-118"9'-118"9'-118"9'-118"9'-118"8'-0" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.T.O.P. F.F. T.O.P. T.O.P. F.F.7'-10201256" HDR. HGT. TYP.GLASS PANEL RAILING WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 1792 S.F. AREA OF WINDOWS 270 S.F. WINDOW PERCENTAGE 15.1% *INCLUDES GLASS GARAGE DOOR 1 D6 6 D6 11 D6 2 D6 STACK BOND BRICK 2x2 WOOD TRIM HORIZONTAL SIDING 8" REVEAL 2x4 WOOD TRIM STONE CAP 2x6 WOOD TRIM 2 D3 2x4 WOOD TRIM 3 D6 SIM. 2x CAP 5 D6 9'-118"9'-118"F.F. F.F. T.O.P. T.O.P.7'-111516" HDR. HGT. TYP.8'-0" HDR. HGT. TYP.9'-118"T.O.S. T.O.P. GLASS PANEL RAILING WINDOW AREA TABULATIONS AREA OF TOTAL FACADE 1724 S.F. AREA OF WINDOWS 387 S.F. WINDOW PERCENTAGE 22.4% 1 D6 6 D6 11 D6 2 D3 2 D6 2x4 WOOD TRIM HORIZONTAL SIDING 8" REVEAL 2x4 CORNER BOARD-TYP. STACK BOND BRICK 2x4 WOOD TRIM 2x4 WOOD TRIM METAL CAP 2x CAP ©LEFT ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY RIGHT ELEVATION "A" 1/4" = 1/-0"NORTHWEST CONTEMPORARY N. 40TH ST (NORTH) SOUTH ELEVATION BA. 5 REC. ROOM BDRM. 5 PATIO CRAWL SPACE3'-0"7'-112"7'-112"3'-0"11'-8"3'-0" WP GFCIOC220v FUSED DISCONNECT AT OPT. AC GFCI WP 3'-0"8'-9"5'-71 2"3'-0"7'-3"3'-0"S 3 TO SWITCH ABOVE S CM GFCI AT OPT. CABINETS BELOW AT OPT. REFRIG. GFCI 5'-3"5'-3"2'-0"8'-1012"2'-0"2'-0"7'-6"2'-0"HBS.O.V.TV TV ©BASEMENT FLOOR UTILITY PLAN "A" 1/4" = 1'-0" UTILITY SYMBOLS WPGFCI GFCI 3 4 +XX" F F B J T HB HB W/ S.O.V. ADDRESS S +XX"F F OC D 220V CM CAT5 RG6-CAT5 100 50 C H 120V DUPLEX CONVENIENCE RECEPTACLE W/ ARC FAULT CIRCUIT INTERRUPT, INSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.) 120V (OR 240V AS NOTED) WEATHERPROOF RECEPTACLE W/ G.F.C.I. 120V DUPLEX CONVENIENCE RECEPTACLE W/ G.F.C.I. 120V 4-PLEX CONVENIENCE RECEPTACLE 120V FLOOR TYPE RECEPTACLE W/ COVER 120V DUPLEX CONVENIENCE RECEPTACLE, 1/2 HOT, THE OTHER HALF SWITCH CONTROLLED 22OV SINGLE CONVENIENCE RECEPTACLE INSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.) TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) W/ OCCUPANCY SENSOR TWO-POLE DIMMER LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) THREE-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) FOUR-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) HUMIDISTAT PHONE JACK INSTALLED 12" ABOVE FINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.) TELEVISION / PHONE JACK INSTALLED 12" ABOVE FINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.) CAT6 NETWORK JACK SURFACE MOUNTED INCANDESCENT WALL LIGHT FIXTURE, SEE PLANS FOR HEIGHT SURFACE MOUNTED FLUORESCENT WALL LIGHT FIXTURE, SEE PLANS FOR HEIGHT SURFACE MOUNTED INCANDESCENT CEILING LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT CEILING LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE 40 LUMENS/WATT HANGING INCANDESCENT LIGHT FIXTURE RECESSED COMBINATION EXHAUST FAN/ INCANDESCENT LIGHT, SWITCH CONTROLLED RECESSED COMBINATION EXHAUST FAN/ FLUORESCENT LIGHT, SWITCH CONTROLLED, 40 LUMENS/WATT RECESSED FRACTIONAL HP EXHAUST FAN, SWITCH CONTROLLED CONTINUOUS FAN COMPLIANT WITH ASHRAE 62.2. VENT TO EXTERIOR WITH 6" DUCT LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 50 CFM MAX 3 SONE OR EXCEEDS 400 CFM LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 100 CFM MAX 3 SONE OR EXCEEDS 400 CFM RECESSED INCANDESCENT "EYE-BALL" CAN LIGHT FIXTURE SURFACE MOUNTED WALL SCONCE LIGHT FIXTURE SEE PLANS FOR HEIGHT SURFACE MOUNTED TRACK LIGHT FIXTURE SEE PLANS FOR LENGTH SURFACE MOUNTED LIGHT BAR ABOVE MIRROR, SEE PLANS FOR LENGTH FUEL GAS OUTLET FUEL GAS LOOSE KEY VALVE PUSH BUTTON FOR GARAGE DOOR OPENER OR CHIMES JUNCTION BOX, W/ COVER OR ADAPTER AS REQUIRED (VOLTAGE AS INDICATED) THERMOSTAT VERIFY LOCATION W/ HVAC LAYOUT HOSE BIBB HOSE BIBB WITH SHUT OFF VALVE ILLUMINATED ADDRESS NUMBERS SMOKE DETECTOR, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 SMOKE/CARBON MONOXIDE DETECTOR COMBO, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 CARBON MONOXIDE DETECTOR, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 DOOR CHIMES, SEE PLANS FOR HEIGHT UNDER CABINET, SURFACE MOUNTED 24" FLUORESCENT LIGHT AS REQUIRED BY CALIFORNIA TITLE 24, 40 LUMENS/WATT SURFACE MOUNTED CEILING FAN, SWITCH CONTROLLED W/ OPTIONAL INCANDESCENT LIGHT 12"X48" SINGLE TUBE OR 24'X48" DOUBLE TUBE CEILING MOUNTED FLUORESCENT FIXTURE, SWITCH CONTROLLED, 40 LUMENS/WATT UTILITY NOTES 1.ELECTRICAL, MECHANICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION & PLACEMENT. ALL HEIGHTS SHOWN ARE TO CENTERLINE OF FIXTURE. 2.PROVIDE GFCI PROTECTED OUTLETS AT THE FOLLOWING LOCATIONS: BATHROOMS, GARAGES, OUTDOORS, CRAWL SPACES LOCATED AT OR BELOW GRADE LEVEL, UNFINISHED BASEMENTS, ALL KITCHEN COUNTERTOPS, AND WITHIN 6'-0" OF LAUNDRY OR WET BAR SINKS 3.RECEPTACLE OUTLETS AT KITCHEN COUNTERTOPS SHALL BE SPACED SO THAT NO PORTION OF THE COUNTERTOP IS FURTHER THAN 24" FROM AN OUTLET 4.WALL OUTLETS IN HABITABLE ROOMS SHALL BE SPACED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6'-0" FROM AN OUTLET AND THAT NO WALL 2' OR GREATER DOES NOT HAVE AN OUTLET 5.WEATHER PROTECT OUTDOOR OUTLETS 6.PROVIDE ONE ELECTRICAL OUTLET IN HALLWAYS AT LEAST 10'-0" LONG 7.OUTLET BOXES FOR CEILING FANS SHALL BE LISTED SPECIFICALLY FOR THAT USE AND BE DESIGNED TO SUPPORT 70 LB PADDLE FANS 8.PROVIDE SWITCH CONTROLLED LIGHTING OUTLETS AT ALL ROOMS, GARAGES AND OUTDOOR ENTRANCES 9.CARBON MONOXIDE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERY LEVEL OF THE DWELLING AND IN THE IMMEDIATE VICINITY OF THE BEDROOMS, PER 2012 IRC R314 & R315. 10.SMOKE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERY LEVEL OF THE DWELLING, IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND IN EACH SLEEPING ROOM, PER 2012 IRC R314 & R315. 11.IN CLOSETS, PROVIDE 12'' HORIZONTAL CLEARANCE BETWEEN THE NEAREST POINT OF A STORAGE SPACE AND A FULLY ENCLOSED INCANDESCENT SURFACE MOUNTED LIGHT 12.RECESSED LIGHTING FIXTURES ON INSULATED CLG'S SHALL BE IC RATED BY U.L. 13.PANEL BOARDS ARE NOT ALLOWED IN STORAGE CLOSETS OR BATHROOMS 14.ELECTRICAL EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING LAB 15.OVER AND UNDER GAS AND ELECTRICAL METERS ARE NOT ALLOWED. 16.BATHROOM OUTLETS SHALL BE SERVED BY A SEPARATE 20 AMP CIRCUIT HOWEVER, THIS CIRCUIT IS PERMITTED TO SUPPLY THE REQUIRED RECEPTACLES IN MORE THAN ONE BATHROOM 17.ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN ALL ROOMS, EXCEPT KITCHEN, BATHROOMS, LAUNDRY ROOMS & GARAGE, SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S), PER WAC 296--46B-210. 18.ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS OF MORE THAN 50 VOLTS SHALL HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM THE EQUIPMENT SERVED. 19.ALL FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE MARKED 'SUITABLE FOR WET LOCATIONS' 20.FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE EVENT OF IGNITION OR FLAME FAILURE. 21.GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND HAVE ITS OPENING SEALED ON OUTSIDE. 22.ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFCI PROTECTED IN KITCHEN AREA 23.PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS 24.BATHROOM CIRCUITS SHALL HAVE NO OTHER OUTLETS, MINIMUM 20-AMP CIRCUIT 25.BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 PERCENT TO A MAXIMUM OF 80 PERCENT. A HUMIDITY CONTROL MAY BE UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO INTEGRAL. (I.E. BUILT-IN) 26.EXHAUST FANS WITH A COMMON EXHAUST SHALL BE PROVIDED WITH A BACKDRAFT DAMPER TO PREVENT RECIRCULATION 27.MECHANICAL WHOLE HOUSE VENTILATION TO BE PROVIDED, IN COMPLIANCE WITH WAC SEC R403.5. 28.GROUND-FAULT CIRCUIT INTERRUPTER PROVIDED AT: - KITCHENS -BATHROOMS -GARAGES -LAUNDRY ROOMS 29.CLOTHES DRYERS TO HAVE 4-WIRE GROUNDED ELECTRICAL OUTLET 30.BOND GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING, POINTS OF ATTACHMENT OF THE BONDING JUMPER(S) TO BE ACCESSIBLE. PER IRC SEC E3607. 31.ALL 125-VOLT, 15- AND 20- AMPERE RECEPTACLES TO BE LISTED TAMPER-RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED PER PER WAC 296--46B-210. WASHINGTON STATE ENERGY CODE 1.EXHAUST FAN FOR LOCAL AND WHOLE HOUSE VENTILATION (CFM'S PER TABLE R403.5.1 OF THE WASHING STATE ENERGY CODE). S CM PLUMBING NOTES 1.PROVIDE AN EXPANSION TANK FOR PLUMBING SYSTEM. 2.PROVIDE MIXING VALVES FOR ALL LAVS, TUBS, AND SHOWERS. 3.PROVIDE / VERIFY A BACKWATER VALVE FOR SANITARY SEWER WHEN REQUIRED. 4.PLASTIC PIPE AND FITTINGS, OTHER THAN THOSE USED FOR GAS, SHALL MEET THE REQUIREMENTS OF NATIONAL SANITATION FOUNDATION 14. 5.ALL PIPE, TUBE, FITTINGS, SOLVENT, CEMENT, THREAD SEALANT, SOLDER, AND/OR FLUX USED IN POTABLE WATER SYSTEMS INTENDED TO SUPPLY DRINKING WATER SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NATIONAL SANITATION FOUNDATION 61. ≤ N GREAT ROOM NOOK KITCHEN BALCONY PAN. BA. 1 STUDY VALET FOYER HALL 2-BAY GARAGE 1-BAY GARAGE PORCH GUEST BDRM.+60"NB A GFCIHB S.O.V. H.B. OPT.220v+80" FOR VENT FG 3 USBTO LIGHTS AND SWITCH BELOW 33 TO LIGHTS AND SWITCH ABOVE FG TO LIGHTS ABOVE 3 S TV S CM OC WPGFCI ℄ AT CEILING FOR GARAGE DOOR OPENER ℄ B ℄ ℄ P GFCI +48" CABLE TV SERVICE BOX TELEPHONE SERVICE BOX 200 AMP ELECT. METER GAS METER PROVIDE GFCI OUTLET INSIDE TOP CORNER OF TELEPHONE/FIBER CABINET SINGLE 110v OR DUPLEX GFCI OUTLET FOR AUTOMATIC SPRINKLER CONTROLLERGFCIWP GFCI GFCI +48" GFCI +48"GFCIGFCI220vGFCIBELOW FOR D.W. AND DISPOSAL GFCI CHANDELIER ℄ ℄ 3 3 3 5'-6"5'-0"5'-0"4'-0"5'-4"1'-6"TCW GFCI +48" GFCI WP P GFCI WP 5'-6"℄5'-6"5'-6"GFCITV GFCIE.V.AT CEILING FOR GARAGE DOOR OPENER COACH LIGHT CENTERED ON WALL AT +84" COACH LIGHT CENTERED ON WALL AT +84" COACH LIGHT CENTERED ON WALL AT +84" COACH LIGHT CENTERED ON WALL AT +84" 2'-0"6'-4"2'-0"2'-0"6'-912"2'-0"3'-0"4'-111 2"3'-0"3'-0"8'-1012"3'-0"3 2'-01 2"10'-6"3'-1012"6'-0"3'-1112"©FIRST FLOOR UTILITY PLAN "A" 1/4" = 1'-0" UTILITY SYMBOLS WPGFCI GFCI 3 4 +XX" F F B J T HB HB W/ S.O.V. ADDRESS S +XX"F F OC D 220V CM CAT5 RG6-CAT5 100 50 C H 120V DUPLEX CONVENIENCE RECEPTACLE W/ ARC FAULT CIRCUIT INTERRUPT, INSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.) 120V (OR 240V AS NOTED) WEATHERPROOF RECEPTACLE W/ G.F.C.I. 120V DUPLEX CONVENIENCE RECEPTACLE W/ G.F.C.I. 120V 4-PLEX CONVENIENCE RECEPTACLE 120V FLOOR TYPE RECEPTACLE W/ COVER 120V DUPLEX CONVENIENCE RECEPTACLE, 1/2 HOT, THE OTHER HALF SWITCH CONTROLLED 22OV SINGLE CONVENIENCE RECEPTACLE INSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.) TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) W/ OCCUPANCY SENSOR TWO-POLE DIMMER LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) THREE-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) FOUR-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) HUMIDISTAT PHONE JACK INSTALLED 12" ABOVE FINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.) TELEVISION / PHONE JACK INSTALLED 12" ABOVE FINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.) CAT6 NETWORK JACK SURFACE MOUNTED INCANDESCENT WALL LIGHT FIXTURE, SEE PLANS FOR HEIGHT SURFACE MOUNTED FLUORESCENT WALL LIGHT FIXTURE, SEE PLANS FOR HEIGHT SURFACE MOUNTED INCANDESCENT CEILING LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT CEILING LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE 40 LUMENS/WATT HANGING INCANDESCENT LIGHT FIXTURE RECESSED COMBINATION EXHAUST FAN/ INCANDESCENT LIGHT, SWITCH CONTROLLED RECESSED COMBINATION EXHAUST FAN/ FLUORESCENT LIGHT, SWITCH CONTROLLED, 40 LUMENS/WATT RECESSED FRACTIONAL HP EXHAUST FAN, SWITCH CONTROLLED CONTINUOUS FAN COMPLIANT WITH ASHRAE 62.2. VENT TO EXTERIOR WITH 6" DUCT LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 50 CFM MAX 3 SONE OR EXCEEDS 400 CFM LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 100 CFM MAX 3 SONE OR EXCEEDS 400 CFM RECESSED INCANDESCENT "EYE-BALL" CAN LIGHT FIXTURE SURFACE MOUNTED WALL SCONCE LIGHT FIXTURE SEE PLANS FOR HEIGHT SURFACE MOUNTED TRACK LIGHT FIXTURE SEE PLANS FOR LENGTH SURFACE MOUNTED LIGHT BAR ABOVE MIRROR, SEE PLANS FOR LENGTH FUEL GAS OUTLET FUEL GAS LOOSE KEY VALVE PUSH BUTTON FOR GARAGE DOOR OPENER OR CHIMES JUNCTION BOX, W/ COVER OR ADAPTER AS REQUIRED (VOLTAGE AS INDICATED) THERMOSTAT VERIFY LOCATION W/ HVAC LAYOUT HOSE BIBB HOSE BIBB WITH SHUT OFF VALVE ILLUMINATED ADDRESS NUMBERS SMOKE DETECTOR, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 SMOKE/CARBON MONOXIDE DETECTOR COMBO, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 CARBON MONOXIDE DETECTOR, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 DOOR CHIMES, SEE PLANS FOR HEIGHT UNDER CABINET, SURFACE MOUNTED 24" FLUORESCENT LIGHT AS REQUIRED BY CALIFORNIA TITLE 24, 40 LUMENS/WATT SURFACE MOUNTED CEILING FAN, SWITCH CONTROLLED W/ OPTIONAL INCANDESCENT LIGHT 12"X48" SINGLE TUBE OR 24'X48" DOUBLE TUBE CEILING MOUNTED FLUORESCENT FIXTURE, SWITCH CONTROLLED, 40 LUMENS/WATT UTILITY NOTES 1.ELECTRICAL, MECHANICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION & PLACEMENT. ALL HEIGHTS SHOWN ARE TO CENTERLINE OF FIXTURE. 2.PROVIDE GFCI PROTECTED OUTLETS AT THE FOLLOWING LOCATIONS: BATHROOMS, GARAGES, OUTDOORS, CRAWL SPACES LOCATED AT OR BELOW GRADE LEVEL, UNFINISHED BASEMENTS, ALL KITCHEN COUNTERTOPS, AND WITHIN 6'-0" OF LAUNDRY OR WET BAR SINKS 3.RECEPTACLE OUTLETS AT KITCHEN COUNTERTOPS SHALL BE SPACED SO THAT NO PORTION OF THE COUNTERTOP IS FURTHER THAN 24" FROM AN OUTLET 4.WALL OUTLETS IN HABITABLE ROOMS SHALL BE SPACED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6'-0" FROM AN OUTLET AND THAT NO WALL 2' OR GREATER DOES NOT HAVE AN OUTLET 5.WEATHER PROTECT OUTDOOR OUTLETS 6.PROVIDE ONE ELECTRICAL OUTLET IN HALLWAYS AT LEAST 10'-0" LONG 7.OUTLET BOXES FOR CEILING FANS SHALL BE LISTED SPECIFICALLY FOR THAT USE AND BE DESIGNED TO SUPPORT 70 LB PADDLE FANS 8.PROVIDE SWITCH CONTROLLED LIGHTING OUTLETS AT ALL ROOMS, GARAGES AND OUTDOOR ENTRANCES 9.CARBON MONOXIDE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERY LEVEL OF THE DWELLING AND IN THE IMMEDIATE VICINITY OF THE BEDROOMS, PER 2012 IRC R314 & R315. 10.SMOKE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERY LEVEL OF THE DWELLING, IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND IN EACH SLEEPING ROOM, PER 2012 IRC R314 & R315. 11.IN CLOSETS, PROVIDE 12'' HORIZONTAL CLEARANCE BETWEEN THE NEAREST POINT OF A STORAGE SPACE AND A FULLY ENCLOSED INCANDESCENT SURFACE MOUNTED LIGHT 12.RECESSED LIGHTING FIXTURES ON INSULATED CLG'S SHALL BE IC RATED BY U.L. 13.PANEL BOARDS ARE NOT ALLOWED IN STORAGE CLOSETS OR BATHROOMS 14.ELECTRICAL EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING LAB 15.OVER AND UNDER GAS AND ELECTRICAL METERS ARE NOT ALLOWED. 16.BATHROOM OUTLETS SHALL BE SERVED BY A SEPARATE 20 AMP CIRCUIT HOWEVER, THIS CIRCUIT IS PERMITTED TO SUPPLY THE REQUIRED RECEPTACLES IN MORE THAN ONE BATHROOM 17.ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN ALL ROOMS, EXCEPT KITCHEN, BATHROOMS, LAUNDRY ROOMS & GARAGE, SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S), PER WAC 296--46B-210. 18.ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS OF MORE THAN 50 VOLTS SHALL HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM THE EQUIPMENT SERVED. 19.ALL FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE MARKED 'SUITABLE FOR WET LOCATIONS' 20.FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE EVENT OF IGNITION OR FLAME FAILURE. 21.GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND HAVE ITS OPENING SEALED ON OUTSIDE. 22.ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFCI PROTECTED IN KITCHEN AREA 23.PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS 24.BATHROOM CIRCUITS SHALL HAVE NO OTHER OUTLETS, MINIMUM 20-AMP CIRCUIT 25.BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 PERCENT TO A MAXIMUM OF 80 PERCENT. A HUMIDITY CONTROL MAY BE UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO INTEGRAL. (I.E. BUILT-IN) 26.EXHAUST FANS WITH A COMMON EXHAUST SHALL BE PROVIDED WITH A BACKDRAFT DAMPER TO PREVENT RECIRCULATION 27.MECHANICAL WHOLE HOUSE VENTILATION TO BE PROVIDED, IN COMPLIANCE WITH WAC SEC R403.5. 28.GROUND-FAULT CIRCUIT INTERRUPTER PROVIDED AT: - KITCHENS -BATHROOMS -GARAGES -LAUNDRY ROOMS 29.CLOTHES DRYERS TO HAVE 4-WIRE GROUNDED ELECTRICAL OUTLET 30.BOND GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING, POINTS OF ATTACHMENT OF THE BONDING JUMPER(S) TO BE ACCESSIBLE. PER IRC SEC E3607. 31.ALL 125-VOLT, 15- AND 20- AMPERE RECEPTACLES TO BE LISTED TAMPER-RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED PER PER WAC 296--46B-210. WASHINGTON STATE ENERGY CODE 1.EXHAUST FAN FOR LOCAL AND WHOLE HOUSE VENTILATION (CFM'S PER TABLE R403.5.1 OF THE WASHING STATE ENERGY CODE). S CM PLUMBING NOTES 1.PROVIDE AN EXPANSION TANK FOR PLUMBING SYSTEM. 2.PROVIDE MIXING VALVES FOR ALL LAVS, TUBS, AND SHOWERS. 3.PROVIDE / VERIFY A BACKWATER VALVE FOR SANITARY SEWER WHEN REQUIRED. 4.PLASTIC PIPE AND FITTINGS, OTHER THAN THOSE USED FOR GAS, SHALL MEET THE REQUIREMENTS OF NATIONAL SANITATION FOUNDATION 14. 5.ALL PIPE, TUBE, FITTINGS, SOLVENT, CEMENT, THREAD SEALANT, SOLDER, AND/OR FLUX USED IN POTABLE WATER SYSTEMS INTENDED TO SUPPLY DRINKING WATER SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NATIONAL SANITATION FOUNDATION 61. ≤ N M. BA. MASTER BEDROOM HALL LAUN. BDRM. 2 LOFT BA. 2 BDRM. 3 W.I.C. SHARED BATH BDRM. 4NTVFGTO SWITCH BELOW 8'-81 2"3'-0"3'-0"3'-0"6'-614"6'-614"9'-0"3'-0"3'-0"3'-0"10'-1"3'-0"USB USB OCWP WP GFCI3'-0"9'-2"3'-0"8'-51 2"3'-0"3'-0" TO SWITCH BELOW 333 NTVTVS S TVWP GFCI OC3 3TVS33OCGFCI WP220v+54"GFCI 75 CFM WHOLE HOUSE FAN TIMEROCSGFCI33 2'-0"7'-41 2"2'-0"2'-0"7'-412"2'-0"2'-0"7'-414"4'-412"2'-0"6'-11"2'-0"2'-0"7'-112"2'-0"2'-0"8'-1"2'-0"©SECOND FLOOR UTILITY PLAN "A" 1/4" = 1'-0" UTILITY SYMBOLS WPGFCI GFCI 3 4 +XX" F F B J T HB HB W/ S.O.V. ADDRESS S +XX"F F OC D 220V CM CAT5 RG6-CAT5 100 50 C H 120V DUPLEX CONVENIENCE RECEPTACLE W/ ARC FAULT CIRCUIT INTERRUPT, INSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.) 120V (OR 240V AS NOTED) WEATHERPROOF RECEPTACLE W/ G.F.C.I. 120V DUPLEX CONVENIENCE RECEPTACLE W/ G.F.C.I. 120V 4-PLEX CONVENIENCE RECEPTACLE 120V FLOOR TYPE RECEPTACLE W/ COVER 120V DUPLEX CONVENIENCE RECEPTACLE, 1/2 HOT, THE OTHER HALF SWITCH CONTROLLED 22OV SINGLE CONVENIENCE RECEPTACLE INSTALLED 12" ABOVE FINISHED FLOOR (U.O.N.) TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) TWO-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) W/ OCCUPANCY SENSOR TWO-POLE DIMMER LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) THREE-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) FOUR-POLE LIGHT SWITCH AT 42" ABOVE FLOOR OR 8" ABOVE COUNTER (U.O.N.) HUMIDISTAT PHONE JACK INSTALLED 12" ABOVE FINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.) TELEVISION / PHONE JACK INSTALLED 12" ABOVE FINISHED FLOOR OR 8" ABOVE COUNTER (U.N.O.) CAT6 NETWORK JACK SURFACE MOUNTED INCANDESCENT WALL LIGHT FIXTURE, SEE PLANS FOR HEIGHT SURFACE MOUNTED FLUORESCENT WALL LIGHT FIXTURE, SEE PLANS FOR HEIGHT SURFACE MOUNTED INCANDESCENT CEILING LIGHT FIXTURE SURFACE MOUNTED FLUORESCENT CEILING LIGHT FIXTURE RECESSED INCANDESCENT LIGHT FIXTURE RECESSED FLUORESCENT LIGHT FIXTURE 40 LUMENS/WATT HANGING INCANDESCENT LIGHT FIXTURE RECESSED COMBINATION EXHAUST FAN/ INCANDESCENT LIGHT, SWITCH CONTROLLED RECESSED COMBINATION EXHAUST FAN/ FLUORESCENT LIGHT, SWITCH CONTROLLED, 40 LUMENS/WATT RECESSED FRACTIONAL HP EXHAUST FAN, SWITCH CONTROLLED CONTINUOUS FAN COMPLIANT WITH ASHRAE 62.2. VENT TO EXTERIOR WITH 6" DUCT LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 50 CFM MAX 3 SONE OR EXCEEDS 400 CFM LOCAL EXHAUST FAN COMPLIANT WITH ASHRAE 62.2. MIN. 100 CFM MAX 3 SONE OR EXCEEDS 400 CFM RECESSED INCANDESCENT "EYE-BALL" CAN LIGHT FIXTURE SURFACE MOUNTED WALL SCONCE LIGHT FIXTURE SEE PLANS FOR HEIGHT SURFACE MOUNTED TRACK LIGHT FIXTURE SEE PLANS FOR LENGTH SURFACE MOUNTED LIGHT BAR ABOVE MIRROR, SEE PLANS FOR LENGTH FUEL GAS OUTLET FUEL GAS LOOSE KEY VALVE PUSH BUTTON FOR GARAGE DOOR OPENER OR CHIMES JUNCTION BOX, W/ COVER OR ADAPTER AS REQUIRED (VOLTAGE AS INDICATED) THERMOSTAT VERIFY LOCATION W/ HVAC LAYOUT HOSE BIBB HOSE BIBB WITH SHUT OFF VALVE ILLUMINATED ADDRESS NUMBERS SMOKE DETECTOR, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 SMOKE/CARBON MONOXIDE DETECTOR COMBO, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 CARBON MONOXIDE DETECTOR, I.C.B.O. APPROVED, CEILING MOUNTED (INSTALL PER MANUFACTURERS SPECIFICATIONS) DETECTORS TO BE HARD WIRED W/ BATTERY BACKUP PER 2013 CRC R314 & R315 DOOR CHIMES, SEE PLANS FOR HEIGHT UNDER CABINET, SURFACE MOUNTED 24" FLUORESCENT LIGHT AS REQUIRED BY CALIFORNIA TITLE 24, 40 LUMENS/WATT SURFACE MOUNTED CEILING FAN, SWITCH CONTROLLED W/ OPTIONAL INCANDESCENT LIGHT 12"X48" SINGLE TUBE OR 24'X48" DOUBLE TUBE CEILING MOUNTED FLUORESCENT FIXTURE, SWITCH CONTROLLED, 40 LUMENS/WATT UTILITY NOTES 1.ELECTRICAL, MECHANICAL AND PLUMBING SYSTEMS ARE SHOWN FOR INTENT ONLY. THESE SYSTEMS SHALL BE ENGINEERED BY OTHERS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION & PLACEMENT. ALL HEIGHTS SHOWN ARE TO CENTERLINE OF FIXTURE. 2.PROVIDE GFCI PROTECTED OUTLETS AT THE FOLLOWING LOCATIONS: BATHROOMS, GARAGES, OUTDOORS, CRAWL SPACES LOCATED AT OR BELOW GRADE LEVEL, UNFINISHED BASEMENTS, ALL KITCHEN COUNTERTOPS, AND WITHIN 6'-0" OF LAUNDRY OR WET BAR SINKS 3.RECEPTACLE OUTLETS AT KITCHEN COUNTERTOPS SHALL BE SPACED SO THAT NO PORTION OF THE COUNTERTOP IS FURTHER THAN 24" FROM AN OUTLET 4.WALL OUTLETS IN HABITABLE ROOMS SHALL BE SPACED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACE IS MORE THAN 6'-0" FROM AN OUTLET AND THAT NO WALL 2' OR GREATER DOES NOT HAVE AN OUTLET 5.WEATHER PROTECT OUTDOOR OUTLETS 6.PROVIDE ONE ELECTRICAL OUTLET IN HALLWAYS AT LEAST 10'-0" LONG 7.OUTLET BOXES FOR CEILING FANS SHALL BE LISTED SPECIFICALLY FOR THAT USE AND BE DESIGNED TO SUPPORT 70 LB PADDLE FANS 8.PROVIDE SWITCH CONTROLLED LIGHTING OUTLETS AT ALL ROOMS, GARAGES AND OUTDOOR ENTRANCES 9.CARBON MONOXIDE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERY LEVEL OF THE DWELLING AND IN THE IMMEDIATE VICINITY OF THE BEDROOMS, PER 2012 IRC R314 & R315. 10.SMOKE DETECTORS TO BE 110 VOLT W/ BATTERY BACKUP AND SHALL BE INTERCONNECTED SO THAT IF AN ALARM SOUNDED IN ONE ROOM, IT SHALL BE SOUNDED IN ALL THE OTHERS, & SHALL BE LOCATED ON EVERY LEVEL OF THE DWELLING, IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND IN EACH SLEEPING ROOM, PER 2012 IRC R314 & R315. 11.IN CLOSETS, PROVIDE 12'' HORIZONTAL CLEARANCE BETWEEN THE NEAREST POINT OF A STORAGE SPACE AND A FULLY ENCLOSED INCANDESCENT SURFACE MOUNTED LIGHT 12.RECESSED LIGHTING FIXTURES ON INSULATED CLG'S SHALL BE IC RATED BY U.L. 13.PANEL BOARDS ARE NOT ALLOWED IN STORAGE CLOSETS OR BATHROOMS 14.ELECTRICAL EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING LAB 15.OVER AND UNDER GAS AND ELECTRICAL METERS ARE NOT ALLOWED. 16.BATHROOM OUTLETS SHALL BE SERVED BY A SEPARATE 20 AMP CIRCUIT HOWEVER, THIS CIRCUIT IS PERMITTED TO SUPPLY THE REQUIRED RECEPTACLES IN MORE THAN ONE BATHROOM 17.ALL BRANCH CIRCUITS THAT SUPPLY 125-VOLT, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS INSTALLED IN ALL ROOMS, EXCEPT KITCHEN, BATHROOMS, LAUNDRY ROOMS & GARAGE, SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER(S), PER WAC 296--46B-210. 18.ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS OF MORE THAN 50 VOLTS SHALL HAVE A POSITIVE MEANS OF DISCONNECT ADJACENT TO AND IN SIGHT FROM THE EQUIPMENT SERVED. 19.ALL FIXTURES INSTALLED IN DAMP OR WET LOCATIONS SHALL BE MARKED 'SUITABLE FOR WET LOCATIONS' 20.FUEL BURNING EQUIPMENT SHALL BE EQUIPPED WITH AN APPROVED AUTOMATIC MEANS WHICH WILL SHUT OFF FUEL SUPPLY TO EQUIPMENT IN THE EVENT OF IGNITION OR FLAME FAILURE. 21.GAS PIPING EXTENDING THROUGH FOUNDATION WALL SHALL BE SLEEVED AND HAVE ITS OPENING SEALED ON OUTSIDE. 22.ALL RECEPTACLES THAT SERVE THE COUNTER AREA SHALL BE GFCI PROTECTED IN KITCHEN AREA 23.PROVIDE MIN. TWO (2) 20-AMP SMALL APPLIANCE BRANCH CIRCUITS FOR KITCHEN AND SHALL HAVE NO OTHER OUTLETS 24.BATHROOM CIRCUITS SHALL HAVE NO OTHER OUTLETS, MINIMUM 20-AMP CIRCUIT 25.BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDISTAT WHICH SHALL BE READILY ACCESSIBLE. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 PERCENT TO A MAXIMUM OF 80 PERCENT. A HUMIDITY CONTROL MAY BE UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO INTEGRAL. (I.E. BUILT-IN) 26.EXHAUST FANS WITH A COMMON EXHAUST SHALL BE PROVIDED WITH A BACKDRAFT DAMPER TO PREVENT RECIRCULATION 27.MECHANICAL WHOLE HOUSE VENTILATION TO BE PROVIDED, IN COMPLIANCE WITH WAC SEC R403.5. 28.GROUND-FAULT CIRCUIT INTERRUPTER PROVIDED AT: - KITCHENS -BATHROOMS -GARAGES -LAUNDRY ROOMS 29.CLOTHES DRYERS TO HAVE 4-WIRE GROUNDED ELECTRICAL OUTLET 30.BOND GROUNDING ELECTRODE TO METAL GAS AND WATER PIPING, POINTS OF ATTACHMENT OF THE BONDING JUMPER(S) TO BE ACCESSIBLE. PER IRC SEC E3607. 31.ALL 125-VOLT, 15- AND 20- AMPERE RECEPTACLES TO BE LISTED TAMPER-RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED PER PER WAC 296--46B-210. WASHINGTON STATE ENERGY CODE 1.EXHAUST FAN FOR LOCAL AND WHOLE HOUSE VENTILATION (CFM'S PER TABLE R403.5.1 OF THE WASHING STATE ENERGY CODE). S CM PLUMBING NOTES 1.PROVIDE AN EXPANSION TANK FOR PLUMBING SYSTEM. 2.PROVIDE MIXING VALVES FOR ALL LAVS, TUBS, AND SHOWERS. 3.PROVIDE / VERIFY A BACKWATER VALVE FOR SANITARY SEWER WHEN REQUIRED. 4.PLASTIC PIPE AND FITTINGS, OTHER THAN THOSE USED FOR GAS, SHALL MEET THE REQUIREMENTS OF NATIONAL SANITATION FOUNDATION 14. 5.ALL PIPE, TUBE, FITTINGS, SOLVENT, CEMENT, THREAD SEALANT, SOLDER, AND/OR FLUX USED IN POTABLE WATER SYSTEMS INTENDED TO SUPPLY DRINKING WATER SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF NATIONAL SANITATION FOUNDATION 61. ≤ N