30 MIL MIN. GEOMEMBRANE
LINER
Y.
30 MIL MIN. GEOMEMBRANE ,` .x' '•Y -� : ry , r. 12" MIN.
LINER _r �3. 'ti ' y.., `� �.„ : f ;": t s. _ DESIGNER TO
DESIGNER TO SPECIFY y°� `+i- .rJ ; t. SPECIFY MIN. PIPE
"'r-^>; ' ` } - : '� •r DESIGNER TO
MIN. CLEARANCE "-+T��_:COVER ASREOUIRED
1 SPECIFY �MIN. PIPE ' �!,:�•.♦:ISri,'c:.. : AROUND UTILITY, SEE NOTE 3 ;..-r BY UTILITY PROVIDER,
COVER AS REQUIRED 30" MIN.
BY UTILITY PROVIDER,
VERIFYTO
BOTTOM OF FACILIN.PARSEIEE NOTE 3 �� �� OonO 30" MIN. O
L NATIVE SOIL, SEE NOTE 2
EXISTING UTILITY SERVICE TO
REMAIN IN PLACE, SEE NOTE 1
SECTION - SHALLOW UTILITY SERVICE
SCALE: NTS
UNDER BIORETENTION FACILITY q
65.00
.-, .1. . .1. .
DESIGNER TO SPECIFY
i ;!?/' ;; ." ;ti,; c � •2
MIN. PIPE COVER AS
' .y
REQUIRED BY UTILITY
7t-'� ; t; �' ;y��5,� • = ;.
PROVIDER, 30" MIN.
EMBED LINER 3" MIN. 1
INTO NATIVE SOIL
NATIVE SOIL.
SEE NOTE 2 EXISTING UTILITY SERVICE TO
REMAIN IN PLACE, SEE NOTE 1
SECTION SHALLOW UTILITY SERVICE
WITHIN BIORETENTION FACILITY 3
SCALE: NTS I 265.00
DESIGNER TO SPECIFY
MIN. CLEARANCE AROUND
UTILITY, SEE NOTE 3
DESIGNER TO
SPECIFY MIN. PIPE
COVER AS REQUIRED
BY UTILITY PROVIDER,
30" MIN.
J ^ OV 30 MIL MIN. GEOMEMBRANE
LINER
LINER
UTILITY SERVICE EMBED LINER 3" MIN
PIPE CASING PER STD. PLAN 412 NATIVE SOIL, EXISTING UTILITY MAIN TO
� .
INTO NATIVE SOIL SEE NOTE 2 REMAIN IN PLACE. SEE NOTE 1
SECTION - ENCA8 D UTILITY SERVICE SECTION - SHALLOW UTILITY MAIN
WITHIN BIORETENTION FACILITY C� WITHIN BIORETENTION FACILITY D
SCALE: NTS 65.00
SCALE: NTS 65.00
NOTES:
1. CONTRACTOR SHALL LOCATE AND DETERMINE DEPTH OF EXISTING UTILITY WITHIN THE FOOTPRINT OF THE BIORETENTION FACILITY WHILE LIMITING THE AMOUNT OF DISTURBANCE TO THE SOIUBACKFILL MATERIAL OVER AND
AROUND THE UTILITY PIPE. IF ELECTROMAGNETIC UTILITY LOCATING, POTHOLING, OR OTHER METHOD REVEALS THAT THE UTILITY PIPE DOES NOT MEET THE REQUIRED CLEARANCE FROM THE BOTTOM OF THE BIORETENTION
FACILITY, THE UTILITY PROVIDER MAY REQUIRE IMPLEMENTATION OF PROTECTION MEASURES THAT EXCEED STANDARDS SHOWN PER THEIR OWN STANDARDS OR REQUIRE THE EXISTING UTILITY TO BE RELOCATED OUT OF
THE BIORETENTION SECTION.
2. EXISTING UTILITIES AND NATIVE SOIL AROUND EXISTING UTILITIES SHOULD REMAIN IN PLACE WHERE POSSIBLE. IF A PORTION OR ALL OF THE UTILITY IS UNCOVERED DURING EXCAVATION OR EXISTING SOIL WITHIN 1 FOOT OF
THE KNOWN EXISTING UTILITY IS SCARIFIED, NATIVE SOIL OR APPROVED ENGINEERED BACKFILL SHALL BE CAREFULLY PLACED AND COMPACTED AROUND THE UTILITY PER THE UTILITY PROVIDER'S REQUIREMENTS.
PROVIDE THE MINIMUM CLEARANCE AROUND THE UTILITY SERVICE OR MAIN AND SETBACKS FROM STRUCTURAL ELEMENTS (I.E. CATCH BASINS, MANHOLES, VAULTS, ETC.) PER THE UTILITY PROVIDER'S REQUIREMENTS.
GENERAL NOTES:
1. ANY DISCREPANCIES BETWEEN THE EXISTING UTILITIES SHOWN IN THE DESIGN DRAWINGS AND THE ACTUAL FIELD CONDITIONS SHOULD BE COMMUNICATED TO THE ENGINEER IMMEDIATELY.
2. UTILITY MAINS SHALL NOT BE SUBJECT TO LOADING FROM NEW CURBSIWALLS. LOAD BEARING LINES TO BE DETERMINED BY THE GEOTECHNICAL ENGINEER.
3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
STD. PLAN - 265.10
• PUBLIC WORKS D:
UTILITY CROSSINGS - BIORETENTION SECTIONS PPR
DEPARTMENT GAZ 9/28/2018 1 9:45
Public Works Atlministntor DATE
GENERAL NOTES;
1.
ALL NEWLY -INSTALLED AND NEWLY-REHABLITATED (PUBLIC AND PRIVATE) SANITARY SEWER AND STORM DRAIN MAIN LINES SHALL BE
INSPECTED BY MEANS OF REMOTE CCTV. CCTV INSPECTIONS AND REPORTS SHALL BE SUBMITTED TO THE CITY OF RENTON INSPECTOR
ASSIGNED TO THE PROJECT PRIOR TO RECEIVING APPROVAL TO INSTALL PROJECT CURES. GUTTERS. AND/OR PAVEMENT.
2,
THE CONTRACTOR SHALL PERFORM ALL CCTV INSPECTIONS IN ACCORDANCE WITH THE NATIONAL ASSOCIATION OF SEWER SERVICE
COMPANIES(NA55G0) PI PEE INE ASSE SSMENT C ERTI FICATION PROGRAM(PACP)-
3.
ALL CCTV OPERATORS SHALL HAVE CURRENT NASSCO PACP CERTIFICATION.
4.
CCTV INSPECTIONS SHALL BE RECORDED INAGRANITENETCOMPATIBLE FORMAT DATABASE USING THE LATEST SOFTWARE VERSION
AND SU8MITTEDNTH ELECTRONIC LINKS BETWEEN THE DATA AND THE VIDEO ON AN EKTERNAL HDD, DVD, OR FLASH DRD/E.
5.
ALL CCTV INSPECTION REPORTS SHALL BE WITHIN +1. TWO (2) FEET OF THE MEASU RED LINEAR FOOTAGE BETWEEN MANNDiALONG
THE EXISTING PIPELINE CENTERLINE FROM THE START OF PIPE TO END OF PIPE.
S.
ALL OWNER AND PACP REQUIRED HEADER INFORMATION MUST BE FULLY AND ACCURATELY ENTERED ON ALL CCTV REPORTS. WORK NOT
FOLLOWNG THESE SPEOFICA71DNS WILL BE REJECTED AND THE CONTRACTOR SHALL BE REQUIRED TD RE -CCTV THE WORK.
7,
THE DOCUMENTATION OF THE WORK SHALL CONSIST OF PACP CCTV REPORTS, PACP DATABASE, LOGS, ELECTRONIC REPORTS, ETC.
NOTING IMPORTANT FEATURES ENCOUNTERED DURING THE INSPECTION. THE SPEED OF TRAVEL SHALL BE SLOW ENOUGH TO INSPECT
EACH PIPE JOINT. TEE CONNECTION, STRUCTURAL DETERIORATION, INFILTRATION AND INFLOW SOURCES, AND DEPOSITS. BUT SHOULD
NOT, AT ANY TIME, BE FASTER THAN 30 FEET PER MINUTE, EXCEPT AS NOTED OTHERWISE IN THIS DOCUMENT.
6,
THE CAMERA MUST BE CENTERED IN THE PIPE TO PROVIDE ACCURATE DISTANCE MEASUREMENTS TO PROVIDE LOCATIONS OF FEATURES
IN THE SEWER AND THESE FOOTAGE MEASUREMENTS SHALL BE DISPLAYED AND DOCUM ENTER ON THE VIDEO. ALL PACP OBSERVATIONS
SHALL BE IDENTIFIED BY AUDIO AND ON A PACP LOG. ALL VIDEO MUST BE CONTINUOUSLY METERED FROM MANHOLE TO MANHOLE. ALL
VIDEO RECORDING SHALL BE CONTINUOUS FROM STRUCTURETO STRUCTURE WITH NO"PAUSING'OF THE VIDEO RECORDING DURING
EACH PIPELINE INSPECTION. THE PIPE SHALL BE CLEANED PRIOR TO THE CCTV INSPECTION TO ENSURE ALL DEFECTS, FEATURE. AND
OBSERVATIONS ARE SEEN AND LOGGED.
9-
JUST PRIOR TO BEGINNING THE CCTV IN5PEC TION, WHILE THE CCTV CAMERA IS IN PLACE AND RECORDING. WATER (CONTAINING DYE)
SHALL BE INTRODVC ED INTO THE UPSTREAM MANHOLE OF EACH PIPE SEGMENT UNTIL IT IS 03SERVE0 AND RECORDED FLOWING PAST
THE CAMERA'S FIELD OF VISION IN ITS ENTIRETY.
10_
THE CC TV CAM E RA SHALL HAVE A WATER -LEVEL MEAS U RI N G DEVIC E (BALL, CYLINDER, ETC-) ATTACHED THAT HAS 1(4- AJAR KINGS TO
SHOW THE DEPTH OF WATER IN THE PIPE DURING THE CCTV INSPECTION.
11_
ALL MANHDLES SHALL BE CHANNELED AND COATED PRIOR TO CCTV INSPECTION.
12_
PER CITY OF RENTON SPECIFICATION 7-08.S(2)A, SEWER AND STORM DRAIN F4 PELINE SHALL HAVE NO MORE THAN 112' OF PONDI NG TO BE
CONSIDERED ACCEPTABLE.
U NLE55 GTHE RWI SF %Q Tf I), DINNING 15 NOT TO5CA LE (NT51
STD. PLAN - 266.00
,•
�1
PUBLIC WORKS
DEPARTMENT
CCTV INSPECTION SPECIFICATIONS
:45 A
RR °
GAZ 9/28/2018 I
v,ble w.es Aa-..n..wr DATE
P �G
Land Planning o Civil Engineering
5130 South 166th Lane
SeaTac, WA 98188
T (206) 229-6422
�Aoy HsX.
A 42�4-01-�
�'LO,c� ��'GISTEg�'��
�SSIONAL E��l
(1) OPEN PICKHOL
r rw 1 rn�t vO 1rI11:
(2) 3I8--16 55 SOCKET HEAD CAP
SCREW (ALL ENHEAD) WNSHRS
ON A B' OVA BOLT CIRCLE
PLAN VIEW
CAST IRON FRAME AND
COVER, SEE NOTE 3 -
I
ASPHALT. SEE NOTE 4
CLEANOUT RISER, SEE NOTE 2
SOIL TIGHT 4S' BEND
WYE r
1' MIN. CURB CUT TO
CATCH BASIN
EDGE OF CATCH BASIN
4+ •
.y e
• e • 4
•
d
4 ♦ .
d 4 � W ♦ Y W W W Y ♦ ♦ W Y Y ♦ Y � W W
Y V W W� �•
iYWYIWI♦Yii iii �
\\ 4 °
A,B.0 UTILITY MAIN
W W W W . W . W i i .. W W ,. w W W J. W . W .
d / + ♦ .r ♦ ♦ Y ♦ ♦ W ♦ + • Y ♦ + 65.1 .r ♦ YI IW + i + i + i + ♦ i CROSSING + i i i ♦ i i i
d ♦ Y W i W ♦ ♦
e
W W W W I W
♦ ,,. Y� W ♦ Y + \ d° d
♦ W ♦ ♦ ♦ •\
i Y Y Y
T W Y i W W W Y* W
W i i °
W Y
d f i •Y W W i W � i I- i W W i_ Y+ W i♦ i
i W W Y i i Y �.' �. i
i W i. W
i i ♦ ♦ W W W 'Y
�Y -. Y ♦ W 1 i- ♦ W 1.1 + Y . Y i W Y i ♦ -
d \♦ + + W Y Y + W + + i UTILITY SERVICE YI I W Y W W W W W + W Y W + 1
♦ + i + i ♦ i ♦ i W + W Y i W Y
W W ♦ W i� W i W i ♦ i CROSSINGSr
W + + + + d
W W ♦ + ♦ d 'AW
Y Y Y W Y + d [
4° W ,r�.r \Y .r '�- +,_ .. W
i ♦iW-
. . W i ♦
\i. W =�=Y= W W i
o W
\ W W♦ W W W♦ W W W♦ W W W W+W♦ W W+ W W W W W W W
li' I
- O to W i Q
� /+ d
iW♦ i i W i i W i W i i
W + i ♦ ♦ i W Y Y W i ♦ ♦
i w W+ .v
4
' - d Gam..` i i i ♦ .. i i i . Y . Y (il i i ♦ Y W i i i . Y . . i i i ♦ i
i
♦ _ i .� 4 d 4
1 W W W-i i i W ♦ i ♦ . W . ♦ i i♦ . i i W W W
4
4 � � i ♦ Y Y + W + Y ♦ ♦ 1+1 Y ♦ ♦ ♦ ♦ W Y ♦ Y ♦ ♦
. W W I l
° G 4
4�`
i ♦ Y' 4-I ♦ i ♦ i a
d ° I IT!
�° d
G
4 a
°
BIORETENTION FACILITY 4 d I I� °
d a
G d Ip ° 4°
A d a
°
4 ° <° d Q 4
d d v
° 4.6
4
4 G 4
° 4 °
°
4
OPTIONAL UTILITY TRENCH DAM (TYP.),
DESIGNER TO SPECIFY
GENERAL NOTES:
1. ABANDONED UTILITIES WITHIN FOOTPRINT OF FACILITY AND OBSERVED DURING CONSTRUCTION MUST BE REMOVED. COORDINATE WITH MUNICIPAL OR PRIVATE OWNER AND ENGINEER.
2. HORIZONTAL SEPARATION BETWEEN WATER MAIN WALL AND TOP OF SLOPE OF THE BIORETENTION FACILITY SHALL BE NO LESS THAN 7 FEET.
3. FIRE HYDRANTS SHALL BE AT LEAST 5 FEET FROM BIORETENTION FACILITY FOOTPRINT.
4. WATER METER SHALL BE LOCATED OUTSIDE BIORETENTION FACILITY FOOTPRINT.
5. MANHOLES SHALL BE LOCATED OUTSIDE BIORETENTION FACILITY FOOTPRINT.
6. A MINIMUM OF 1 FOOT SEPARATION BETWEEN SANITARY SEWER CROSSINGS AND UNDERDRAINS SHALL BE MAINTAINED.
7. UTILITY SERVICE AND UTILITY MAIN CROSSINGS SHALL BE MADE PERPENDICULAR TO THE BIORETENTION FACILITY.
8. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS,
UNLESS OTHERWISE NOTED, DRAWING 15 NOT TO SCALE (NTS)
TD. PLAN - 265.00
PUBLIC WORKS
UTILITY CROSSINGS - BIORETENTION
9/28/2018
EG
DEPARTMENT
�,.,,���,„rim. DATE
h _ T DIA -il
4'
B-118" pIA
1a112' DIA
15' DIA
FRAME SECTION
PAVED AREA (EYP-1
12- EXTEND OV OE SIG CLEANOUT RISER
2-ABOVE DESIGN PONDING
ELEVATION OR PER PLAN
a DESIGN PONDING
ELEVATION -
d" COMPACTED SAND OR
GRAVEL BACKFILL FOR DRAINS
PER WSDOT 9-03.12(4) Q
�-{ 8.13,'16' DIA �+-•
I1T1}
5t8•
FERNCO GASKETE D
OUIKCAP OR SIMILAR
r4' STREAMBED COBBLES
I PER WEOGT 9-W.11(2)
CLEANOUT RISER
SEE NOTE 2
I
CLEANOUT RISER LOCATED WITHIN
BIORETENTION PONDING AREA
SOIL TIG HT
COUPLER
UNDERDRAIN, FOOTING
DRAIN COLLECTOR, DR
ROOF DRAIN COLLECTOR
'
PIPE, SEE NOTE 1
�.
TOOVERFLOW
'•
STRUCTURE OR
STORM MAIN f
\,
MEC HANICAL PLUG OR
CONTINUED CONNECTION
TYPICAL CLEANOUT
CONFIGURATION
NOTES:
1. DIAMETER TO BE &INCHES MINIMUM PRIVATE, 8•1NCHES MINIMUM PUBLIC. U N DERDRAIN PI PE PER STD. PLAN 262.10.
2, CLEANOUT RISER SHALL BE SAME SIZE AND MATERIAL AS CONINECTED UNDERDRAIN, FOOTING DRAIN COLLECTOR, OR ROOF DRAIN COLLECTOR PIPE.
3. FRAME AND COVER SHALL BE EJ PRODUCT NO. OC367549801 OR APPROVED EQUAL. COVER TO BE LOCKING WITH ALLEN HEAD BOLT, MARKED -STORM'-
4. FOR CLEANOUTS FULLY OR PARTIALLY WITHIN UNPAVED AREAS OUTSIDE OF BIORETENTION PONDING AREA, POURS' THICK, 2'x2 SQUARE CONCRETE
COLLAR AROUND FRAME. CONCRETE COLLAR SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.000 PSI.
GENERAL NOTES:
1. CLEANOUTS FOR UNDER DRAIN, FOOTING DRAIN COLLECTOR, AND ROOF DRAIN COLLECTOR PIPES SHALL BE INSTALLED AT A MINIMUM OF EVERY 100
FEET. AT EVERY 90 DEGREE OR SECOND 45 DEGREE BEND, AT THE END OF EVERY COLLECTOR PIPE. AND AT EACH END OF AN UN DERDRAIN PIPE NOT
CONNECTED TO AN OVERFLOW STRUCTURE. CLEANOLITS SHALL BE INSTALLED TO ALLOW FOR MAINTENANCE ACCESS TO ALL PIPES
2, ALL FITTINGS SHALL BE SOIL TIGHT.
3. CLEANOUT RISER SHALL BE LOCATED OUTSIDE OFSIORETENTION PONDING WHERE POSSIBLE.
4. CLEANOUTSSH/LLL NOT BE LOCATED WITHIN THE STREET TRAVEL LANE, UNLESS OTHERWISE APPROVED BY THE CITY.
UNLESS ONERwISC NOTED, DRAWING IS NOT TO SCALE (NTS;'
STD. PLAN - 226.00
PUBLIC WORKS APPROVED:
DEPARTMENT STORM SYSTEM CLEANOUT GAZ 9/28/2018 1
GATE
JOB NO.
F U7420
NO.
REVISION
:45
DocuSign Envelope ID: 6EECF586.602A-4E4A-B436-A317AA638878
SEE NOTE 2 10'MIN. 5' MIN.
n
HOUSE
YARD DRAIN OR CATCH BASIN
1 PLAN WITH SOLID LID
ROOF DOWNSPOUT WITH OVERFLOW
WYE AND SPLASH BLOCK
PERFORATED PIPE TO BE LEVEL
FLEXIBLE G,45KETED
CAP PER ASTM D5926
CLEANOUT
PER STD. PLAN 226.00 6' MIN. 8' MIN, HOUSE
2' MIN,
12" 8' DIA. MIN. SQH40 PVC
12' PIPE PER ASTM 01785
6' DIA. MIN. FERFORATEO RVC
• 3- TO 1-1 f2- WASHED DRAIN ROCK PIPE PER ASTM 01765
' FINE MESH SCREEN, S5304 10z 10 OR SIMILAR
ELEVATION
COMPACTED BACKFILL
f
6' MIN., "N
PIPE~
NON WOVEN GEOTEXTILE FOR SEPARATION
ON TOP AND SIDES OF TRENCH PER WSDQT
SPECIFICATIONS SECTION 9.33.211) TABLE 3
12" MIN.
12' MIN. ABOVE SEASONAL HIGH.\
GROUNDWATER OR HYDRAULICALLY 24' MIN.
RESTRICTIVE LAYER
SECTION A
NOTES:
1. IS MINIMUM SETBACK FROM INFILTRATION TRENCH TO BUILDINGS WITH CRAWL SPACES, BASEMENTS, OR ELEVATIONS
BELOW THE OVERFLOW POINT.
2. REQUIRED TRENCH LENGTH VARIES DEPENDING ON SOIL TYPE, UP TO 100' MAX. WHEN LOCATED IN COARSE SANDS OR
COBBLES. INFILTRATION TRENCHES MUST BE AT LEAST 20' IN LENGTH PER 1,000 SQUARE FEET OF IMPERVIOUS
SURFACE SERVED. WHEN LOCATED IN MEDIUM SANDS, INFILTRATION TRENCHES MUST BE AT LEAST 39IN LENGTH PER
1.000 SQUARE FEET OF IMPERVIOUS SURFACE SERVED.
3. SEE CONSTRUCTION PLANS FOR SPECIFIC PROJECT REQUIREMENTS.
UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SOLLE (RiSI
STD. PLAN - 225.20
= PUBLIC WORKS
SINGLE FAMILY ROOF DOWNSPOUT
°°R °
JL�A-*Ar DEPARTMENT
INFILTRATION TRENCH
GAZ 9/28/2018 I
:45 A
DATE
BY I DATE I APPR
DESIGNED:
H. H. PHAN
DRAWN:
H. H. PHAN
CHECKED:
APPROVED:
SCALE:
VERTICAL: NAVD 1988
NA HORIZONTAL: NAD 1983/1991
DATUM
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
CITY OF
RENTON
Planning/Building/Public Works Dept.
�70•
I s', Y, 4'.11 I r. OR W
L ONE 93 BAR HOOP FOR T HEIGHT
INCREMENT (SPACED EQUALLY),
SEE NOTE 1
RECTANGULAR ADJUSTMENT SECTION
*3 BAR EACH CORNER
43 BAR EACH SIDE
03 BAR EACH WAY
PRECAST BASE SECTION
43 BAR HOOP
#3 BAR EACH
CORNER 15" MIN.
SEE NOTE I
ALTERNATIVE PRECAST BASE SECTION
• PUBLIC WORKS
DEPARTMENT
PIPE ALLOWANCES
MAXIMUM
PIPE MATERIAL
INSIDE
DIAMETER
REINFORCED OR PLAIN
CONCRETE
12.
ALL METAL PIPE
15'
CPSSP',
STD. SPEC. 9.05.20
12'
SOLID WALL PVC,
STD. SPEC- 9-06.12(1)
15"
PROFILE WALL PVC,
STD. SPEC.9-06.12(2)
15,
'CORRUGATED POLYETHYLENE$TQRM
SEWER PIPE
NOTES:
1. AS ACCEPTABLE ALTERNATIVES TO THE RE BAR SHOWN
IN THE PRECAST BASE SECTION. FIBERS (PLACED IN
ACCORDANCE WITH STANDARD SPECI FICATIO N
9.05.5019)), OR WIRE MESH HAVING A MINIMUM AREA OF
O.12 SQUARE INCHES PER FOOT SHALL BE USED WITH
THE MINIMUM REQUIRED REBAR SHOWN IN THE
ALTERNATIVE PRECAST BASE SECTION, WIRE MESH
SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN
ACCEPTABLE ALTERNATIVE TO THE RE BAR SHOWN IN
THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH
RAVINGA MINIMUM AREA OF 0.12 SQUARE INCHES PER
FOOT MAY BE US ED.
2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER
THAN 20'. KNOCKOUTS SHALL HAVE WALL THICKNESS
OF 2' MINIMUM TO 23' MAXIMUM. PROVIDE A 1.5'
MINIMUM GAP BETW EEN THE KNOCKOUT WALL AND THE
OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED,
FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH
STANDARD SPECIFCATION 94M.3.
3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO
THE LOWEST PIPE INVERT SHALL BE 5 FEET.
4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE
FLANGE DOWN.
5, THE PRECAST BASE SECTION MAY HAVE A ROUNDED
FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF
1 H:24V OR STEEPER.
6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE
PRECAST BASE SECTION.
7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE
INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR
NON -SHRINK APPLICATIONS INACCORDANCE WITH
STANDARD SPECIFICATION 9.20.3(2),
8. ALL GRADE RINGS AND CASTI NGS SHALL BE SET IN
MORTAR IN ACCORDANCE WITH STANDARD
SPECIFICATION 9.01 THEN APPLY MORTAR TO INSIDE
AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND
FRAMES.
9. MORTAR SHALL BE MIXED AND APPLIED PER
MANUFACTURER'S DIRECTIONS.
10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY
TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS
DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT
LENGTH.
11, ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND
REMAIN VISIBLE U PON COMPLETION.
CATCH BASIN TYPE 1
UN LESS OTH ERYN SE NOTED, DRAWING IS N OT TO SCALE I NTS)
STD. PLAN - 200.00
APPR ED:
GAZ 9•/28,/2018 7-45
,9
ad.4+4tra,w f:;,Tf
R-405512
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING
swarlick 04/18/2019
CALLIDUS COMMUNITY DUPLEX
15-04 KIRKLAND AVE NE
RENTON, WA 98056
STANDARD DETAILS - 6