HomeMy WebLinkAboutR-405602SYMBOL LEGEND
DRAWN ON THIS SHEET
X BUILDING, WALL SECTIONS
#x # x # AND DETAIL REFERENCES
DRAWN ON THIS SHEET
REFERENCED FROM THIS SHEET
X REFERENCE TO DETAIL
#x # x # I\ P LAN
X DETAIL DESIGNATION
XXXX DRAWN ON SHEET NUMBER
x SECTION/DETAIL DESIGNATION
XXXXX XXXXX DRAWN ON SHEET NUMBER
REFERENCED ON SHEET NUMBER
0
sTs
Q-
D
-TOFA
- ROFA-
A
ss
•c0
E
cw
FW
Tw
Twc
11
11� .:: all or,
CONSTRUCTION ABOVE OR BELOW,
BEYOND OR BEHIND
FLAG NOTE FOR SPECIFIC
CONSTRUCTION DIRECTION
GENERAL "BOAT" NOTE FOR
SPECIFIC OR EXIST. INFORMATION
CHAINLINK FENCE
AIRCRAFT CLEARANCE LINES
CMP SLOT DRAIN
STORM SEWER
FUEL SPILL LINE, DIP
TYPE 1 CATCH BASIN, SOLID LID
TYPE 1 CATCH BASIN, GRATE
TYPE 2 CATCH BASIN, SOLID LID
TYPE 2 CATCH BASIN, GRATE
TAXIWAY OBJECT FREE AREA
RUNWAY OBJECT FREE AREA
AIRPORT LEASE LINE
CLEARANCE LINE
COMPRESSED AIR
SANITARY SEWER
CLEANOUT
ELECTRICAL
DOMESTIC WATER
FIRE WATER
TEPID WATER
TEPID WATER COLLECTION
AUTOMATED SLIDE GATE
TURNSTILE
ADA ACCESSIBLE GATE
BOLLARD
ASPHALT PAVEMENT
CONCRETE PAVEMENT
CONCRETE PANEL
SYM
REVISION
BY
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
-
APRON
C
Cl
PROJECT
- SITE
DCN-04
RT
TWN
03.09.16
-
APRON C
Cl PROJECT -
SITE
DCN-09
RT
TWN
05.11.16
-
APRON
C
Cl
PROJECT
- SITE
DCN-05
RT
TWN
03.28.16
-
APRON C
Cl PROJECT -
SITE
DCN-10
RT
TWN
06.06.16
-
APRON
C
Cl
PROJECT
- SITE
DCN-06
RT
TWN
04.05.16
-
APRON C
Cl PROJECT -
SITE
DCN-11
RT
TWN
07.05.16
-
APRON
C
Cl
PROJECT
- SITE
DCN-07
RT
TWN
04.12.16
-
RECORD
DRAWING - 737
MAX
FLIGHTLINE UTILITIES
RT
TWN
10.17.16
-
APRON
C
Cl
PROJECT
- SITE
DCN-08
RT
TWN
04.22.16
APRON C
PARCEL 820
RT
TWN
02.08.19
ABBREVIATIONS
&
AND
INCL
@
AT
JT
AB
ANCHOR BOLT
ADJ
ADJACENT
K
AFF
ABOVE FINISHED FLOOR
KO
AGG
AGGREGATE
L
AL
ALUMINUM
LB
ALT
ALTERNATE
LEN
ANCH
ANCHOR, ANCHORAGE
LF
APA
AMERICAN PLYWOOD ASSOC.
LL
APPD
APPROVED
LWR
APPROX
APPROXIMATE
ASTM
AMERICAN SOCIETY
MATL
OF TESTING MATERIALS
MAX
BTWN
BETWEEN
MB
BLDG
BUILDING
MBR
BLKG
BLOCKING
MET
BOT
BOTTOM
MFR
MIN
C
CHANNEL
MISC
CB
CATCH BASIN
MT
CC
CENTER TO CENTER
MTL
CEM
CEMENT
CF
CUBIC FEET
N
CJ
CONTROL JOINT
NF
CL
CENTER LINE
NIC
CLR
CLEAR(ANCE)
NO.
CMP
CORRUGATED METAL PIPE
NOM
COL
COLUMN
NTS
COMP
COMPRESS(ED) (ION)
OA
CONIC
CONCRETE
O/C
CONN
CONNECTION
OD
CONST
CONSTRUCTION
OF
CONT
CONTINUOUS, CONTINUE
OPG
CONTR
CONTRACT(OR)
OPP
CTSK
COUNTERSUNK
CY
CUBIC YARD(S)
P
PAR
0
DIAMETER
PCC
DBL
DOUBLE
PCF
DEMOL
DEMOLISH, DEMOLITION
PERF
DEP
DEPRESSED
PERIM
DI
DUCTILE IRON
PL
DIA
DIAMETER
PLYWD
DIAL
DIAGONAL
PNL
DIM
DIMENSION
PREST
DL
DEAD LOAD
PRF
DN
DOWN
PSF
DS
DOWNSPOUT
PSI
DWG
DRAWING
PT
E
EAST (COORDINATE)
PVC
EA
EACH
R
EB
EXPANSION BOLT
R
EF
EACH FACE
REF
EJ
EXPANSION JOINT
REINF
EL
ELEVATION
REQ
ELEV
ELEVATION
REV
EQ
EQUAL
RH
EW
EACH WAY
RO
EXIST
EXISTING
EXP
EXPOSED
S
EXT
EXTERIOR
SECT
SF
FAS
FASTEN(ER)
SHT
FF
FACTORY FINISH
SIM
FF
FINISHED FLOOR
SQ
FGR
FINISH GRADE
SST
FH
FIRE HYDRANT
ST
FIN
FINISHED)
STD
FND
FOUNDATION
STL
FOC
FACE OF CONCRETE
STR
FOF
FACE OF FINISH
SYM
FOIC
FURNISHED BY OWNER/
SYS
INSTALLED BY CONTRACTOR
FO
FINISHED OPENING
T&B
FRO
FOR REFERENCE ONLY
T&G
FT
FOOT
TEMP
FTG
FOOTING
THK
FUT
FUTURE
TOC
GA
GAGE
TOC
TOL
GALV
GALVANIZED
TOS
GC
GENERAL CONTRACTOR
TS
GI
GALVANIZED IRON
TYP
GR
GRADE
GT
GROUT
UBC
HDNR
HARDENER
UL
HDPE
HIGH DENSITY POLYETHYLENE
UNO
HDWD
HARDWOOD
UPR
HDWR
HARDWARE
VB
HG
HIGH GRADE
VERT
HM
HOLLOW METAL
HOR
HORIZONTAL
W
HS
HIGH STRENGTH
W
HT
HEIGHT
W
ID
INSIDE DIAMETER
WO
W
ID
INSIDE DIMENSION
W/0
IF
INSIDE FACE
WWF
IN
INCH
Q� BOE/NG°
C'—
GENERAL NOTES
INCLUDED(D) (ING)
1)
THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CLOUD(S) MARKED WITH THE REVISION (REV) LETTER WHICH MATCHES THE ONE
JOINT
INDICATED IN THE LOWER RIGHT CORNER OF THE SHEET OR THE LATEST REV LETTER IN THE REVISION SECTION OF THE TITLE BLOCK. IF
THERE IS NO CLOUD ON THE SHEET, THE ENTIRE SHEET IS IN THE SCOPE OF WORK, UNLESS IT'S A DETAIL SHEET. A DETAIL REFERENCED
KIPS)
WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK EVEN WHEN THE ACTUAL DETAIL DRAWING IS NOT CLOUDED ON THE DETAIL SHEET.
KNOCK OUT
LEGENDS AND GENERAL NOTES ALWAYS APPLY WHETHER CLOUDED OR NOT. CONSTRUCTION NOTES PERTAINING TO THIS JOB WILL BE CLOUDED
LENGTH
AND MARKED WITH THE MATCHING REV LETTER UNLESS ON A SHEET WHERE THERE ARE NO CLOUDS AT ALL, THEN ALL NOTES APPLY. FLAG
LAG BOLT
NOTES POINT TO SPECIFIC INSTANCES OF THE CONSTRUCTION; NUMBERED NOTES APPLY TO THE ENTIRE CONSTRUCTION AREA.
LENGTH
LINEAL FEET
2)
PROVIDE MEANS PURCHASE AND INSTALL TO COMPLETE WORKING ORDER, INTEGRATED WITH ADJACENT BUILDING ELEMENTS AND FINISH ITEMS, IN
LIVE LOAD
FULL COMPLIANCE WITH DESIGN INTENT. INSTALL MEANS, OBTAIN ITEM(S) TO BE INSTALLED FROM OWNER AT LOCATION AS DIRECTED BY
LOWER
CONSTRUCTION MANAGER, AND INSTALL IN SAME MANNER AND COMPLIANCE AS IF PURCHASED.
MATERIAL
3)
KEEP AREAS UNDER CONSTRUCTION CLEAR OF DIRT AND DEBRIS CAUSED BY DEMOLITION AND STORE CONSTRUCTION MATERIALS AND EQUIPMENT
MAXIMUM
IN AREAS DESIGNATED BY THE CONSTRUCTION MANAGER.
MACHINE BOLT
MEMBER
4)
VERIFY DIMENSIONS & CONDITIONS SHOWN ON THE DRAWINGS AND ON SITE AND ACCEPT RESPONSIBILITY FOR THE JOINING OF WORK AMONGST
METAL
MANUFACTURE(R)
VARIOUS TRADES AND TO EXISTING CONDITIONS. BRING DISCREPANCIES ON DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE
MINIMUM
CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY.
MISCELLANEOUS
MOUNTED) (ING)
5)
STOP WORK IN AREA WHERE ASBESTOS &/OR LEAD PAINT IS SUSPECTED. IMMEDIATELY REPORT DISCOVERY TO CONSTRUCTION MANAGER FOR
TESTING AND POSSIBLE REMEDIAL ACTIVITY BY BOEING.
M ETAL
NORTH (COORDINATE)
6)
ENSURE ALL WORK CONFORMS TO APPLICABLE CODES AND REGULATIONS.
NEAR FACE
NOT IN CONTRACT
7)
COMPLY WITH THE CONSTRUCTION MANAGER (OR PROJECT ADMINISTRATOR) FOR CONSTRUCTION AREA AND SECURITY REGULATIONS.
NUMBER
NOMINAL
8)
PROVIDE ALL REPETITIVE FEATURES NOT FULLY SHOWN ON THE DRAWINGS AS IF DRAWN IN FULL SO THAT THE WORK COMPLETELY MEETS THE
NOT TO SCALE
INTENT OF THE CONTRACT DOCUMENTS.
OVERALL
9)
DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF CONCRETE OR MASONRY WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS,
ON CENTER
UNLESS NOTED OTHERWISE. DIMENSION ARE NOT SHOWN IN CONDITIONS WHERE NEW CONST IS TO ALIGN WITH EXISTING FACE OR CENTER
OUTSIDE DIAMETER
LINE.
OUTSIDE FACE
OPENING
OPPOSITE
10)
PATCH AND PAINT ALL EXISTING SURFACES DAMAGED DURING REMOVAL AND CONSTRUCTION (PAINT ENTIRE CONTINUOUS SURFACE).
PAINT
11)
PRIOR TO INSTALLING FINISHES, INSPECT, PATCH AND REPAIR ALL SUBSURFACE CONDITIONS TO PROVIDE A SMOOTH, FLAT FINISH THROUGHOUT.
PARALLEL
PRECAST CONCRETE
12)
PLANS WHICH APPEAR AS BACKGROUNDS ON MECHANICAL AND ELECTRICAL DRAWINGS, ARE ONLY FOR THE PURPOSE OF ILLUSTRATING GENERAL
POUNDS PER CUBIC FOOT
PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT RELATED TO THE SPECIFIC
PERFORATE(D)
SYSTEMS SHOWN ON EACH SHEET AS INDICATED IN THE DRAWING SUB —TITLE.
PERIMETER
PLATE
13)
TAKE RESPONSIBILITY FOR COORDINATION OF ARCHITECTURAL, MECHANICAL, AND ELECTRICAL WORK. REFER TO ARCHITECTURAL, MECHANICAL AND
PLYWOOD
ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC REQUIREMENTS.
PANEL
PRESTRESS(ED)
14)
VERIFY LOCATION OF ALL UTILITIES PRIOR TO WORK BELOW INTERIOR FINISH FLOOR OR EXTERIOR PAVING.
PREFORMED
POUNDS PER SQUARE FOOT
15)
OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE AUTHORITY HAVING JURISDICTION PRIOR TO COMMENCING CONSTRUCTION.
POUNDS PER SQUARE INCH
POINT
POLYVINYL CHLORIDE
16)
PROVIDE MANUFACTURER'S INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE
REFERENCED IN THE CONSTRUCTION NOTES.
RADIUS (CURVATURE)
RISER
17)
COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED MATERIALS TO
REFERENCE, REFER TO
BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED.
REINFORCE(D) (ING)
REQUIRED) (ING)
18)
SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR
REVISION(S), REVISED
MATERIAL CALLOUTS.
RIGHT HAND
ROUGH OPENING
19)
PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION, BETWEEN ALL FIRE RESISTANCE RATED CONSTRUCTION
SOUTH (COORDINATE)
AT FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS.
SECTION
SQUARE FEET
20)
VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. PROVIDE ACCESS FOR
SHEET
ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES.
SIMILAR
SUBMIT THE LOCATIONS, SIZES & TYPES OF EXPOSED ACCESS DOORS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION OF THE
SQUARE
MECHANICAL AND ELECTRICAL EQUIPMENT.
STAINLESS STEEL
STRUCTURAL TEE
STANDARD
STEEL
STRUCTURAL
SYM M ETRY,SYM METRICAL
SYSTEM
TOP AND BOTTOM
TONGUE AND GROOVE
TEMPORARY
THICKNESS)
TOP OF CONCRETE
TOP OF CURB
TOLERANCE
TOP OF STEEL
STRUCTURAL TUBE
TYPICAL
UNIFORM BUILDING CODE
UNDERWRITERS' LABORATORY
UNLESS NOTED OTHERWISE
UPPER
VAPOR BARRIER
VERTICAL
WEST (COORDINATE)
WIDE FLANGE
WIDTH, WIDE
WHERE OCCURRING
WITH
WITHOUT
WELDED WIRE FABRIC
w
ACCEPTABILITY
DRAWN
R. TEMPLADO
SFij
THIS DESIGN AND/OR
CHECKED
T. NEU
o G
SPECIFICATION IS APPROVED
ENGINEER
APPROVED BY
DEPT.
DATE
T. NEU
CHECKED
D. MURATA
4
APPROVED
NAL
...
IN COMPUA I C E Vyll I- %;I ry OF FRENTON $TANDARD$
DEVELOPMENT ENGINEERING
rnair 04/26/2019 '
IFIC SUBMITTAL
FEBRUARY 8, 2019
AIL SUBTITLE
02.08.19
02.08.19
TITLE
02.08.19
02.08.19
CIVIL MASTER
KEY SHEET
BOEING APRON C PARCEL 820 PROJECT
SITE 05-YD
JOB NO.
RENTON, WA DWG N0.
R-405602
41"D
REVISION SYMBOL DATE
W3441886
Gl Gl
W3441886 COMP NO.
05—APRON—C—G1