+60" +60" I BADGE READER 1 _ _ — GE READER G _ _ — — G — ►I DATA DROP/BADGE READER
TURNSTILE l 1 X _ i +18 G_--
® OPERATOR + 172------„-----�_ —T _ N❑ PEDESTAL MOUNTED DATA DROP/BADGE READER
XTURSTILE I _96G — —
TROLLER I G I 1 "PVC, C.O. _ E E y 120V, 10 MOTOR
,,, G _+-42— I —
x x x—fix (2)1 "C.O. � _ __ -- —
X o x _ G—_— G __-- E 0� CAMERA
Y T Y 1 C.O. ADA DOOR r E-- - -- -----
x I GENERAL NOTES
I 1 ` -- -- -- -- — —------- OPERATOR �� _ _ E — — — — 1
0 1 1 1 "C.O. 'J" 72 — — — — E 3/4" LOOP CONDUIT #4/0 1 1. ALL NEW STRUCTURES AND FACILITIES ARE PARALLEL
_x_x 1 I I ()1 "C.0 (2) "C.O. e o (2)1 C. o (2) "C.O. — — —
—f--- i 1--- AND PERPENDICULAR TO EAST BOEING LEASE LINE AT
f 1 1 f 1 BEARING N4°48'53"W.
Il-----------------------------11
`--------— — — — — — — — — — — — -- --------— I I I I I I 2. PER IFC 2009, CHAPTER 11, AVIATION FACILITIES:
---------- ----------------
l — — — — 1 co I GROUND 1 I GROUND I AIRCRAFT BEING FUELED SHALL BE POSITIONED SUCH
--
05-430/3B i LOOP 4 400PI�-- 1 i �'--fT �! LOOP i THAT ANY FUEL SYSTEM VENTS AND OTHER FUEL TANK
3/4"C, 2#10, #10G I PEDESTAL MOUNTED I I I I I I II 1 OPENINGS ARE A MINIMUM OF TWENTY—FIVE FEET (7620
I BADG READER — � TO BUILDING I I I I I I I MM) FROM BUILDINGS OR STRUCTURE OTHER THAN JET
< < I I BRIDGES; AND FIFTY FEET (15,240 MM) FROM AIR
— 45-430 _ _ _ INTAKE VENTS FOR BOILER, HEATER OR INCINERATOR
1 "PVC, C.O. I I I ROOMS.
TURNSTILE SLIDING
ENLARGED P A 760 PARCEL GATEII I 3/4" LOOP CONDUIT #4/0
1 3. REPAIR OR REPLACE ANY AND ALL PAVEMENT DISTURBED
SCALE: 1 " = 2' E61 E510 I I I DURING CONSTRUCTION IN ACCORDANCE WITH C501 AND
1 I THE SPECIFICATIONS.
I I (2) 3/4" LOOP CONDUIT #4/0
1 / A +18" I 1 4. CONTRACTOR SHALL SUBMIT BORING PLANS AND
BADGE BADGE I I PROFILES TO DESIGN TEAM FOR APPROVAL PRIOR TO
READER 1 READER 1 PEDESTAL MOUNTED PHOTO EYE + I I I MOBILIZING.
+ BADGE READER I I 1
0" +6 i X 5. CONTRACTOR SHALL PROVIDE THOROUGH LOCATE SERVICE
1/2" PHOTO EYE FOR ALL AREA'S IN BORE OR TRENCH PATH.
TURNSTILE TURNS LE ADA DOOR / z 1 72 x CONDUIT
6. ALL DIRECT BURIED CONDUIT SHALL BE SHEDULE 80
CONTROLLER 1 OPERAT OPERATOR + I OPERATOR CONDUIT. SWEEPS WHICH ENTER THE EARTH SHALL BE
x x X x x A,GATE
x PVC COATED RIGID STEEL.
x 1
S (2)1 "C.O. (2)1 "C.O. T I 7. ABOVE GRADE EXPOSED CONDUIT SHALL BE EITHER RIGID
—� 172„ X 1/2" PHOTO EYE ALUMINUM OR PAINTED RIGID GALVANIZED STEEL. PER
L 2 1 "C.O. �1 "C.O. _I I I I CONDUIT THE SPECIFICATIONS.
1 " PVC, C.O. P�l I PHOTO EYE
1
X 1 I 1 8. ALL POWER CONDUCTORS SHALL BE XHHW.
+18
1 "PVC, C.O. I 1 i 1 "PVC, C.O. 9. PROVIDE EXPLOSION PROOF SEAL —OFFS ON ALL CONDUIT
(2)1 "PVC, C.O. II 1 I I
----------------�1 ---------------1— -- X 1 I I I PVC, C.O. THROUGH THE ENTERING OR EHAZARDOUS AREA.XITING THE EARTH IN, OR PASSING
PSC7-1 /8a I 1 1
PEDESTAL MOUNTED I 1 1 I 10. ALL CONDUCTORS INSTALLED OUTDOORS SHALL BE
34"C, 2#12, #12 GND BADGE READER X 1 I j 1 XHHW.
1 1 1 1 "C. 2#12,
X , I #12G REFERENCE DRAWINGS
ENLARGED TUR ST �E PLAN 820 PARCEL 3 11 I , A
SCALE: 1 " = 2' E360 E510
X ; I 1 1 CONSTRUCTION NOTES
I
1 1 I
x I I I AT THE PARCEL 820 TURNSTILE, DISCONNECT THE
LIGHT POLE II
1 I TURNSTILE CONTROL CABINET AND ALL BADGE READER
(BY OTHERS) I j EQUIPMENT, AND RETURN THE EQUIPMENT TO BOEING.
SURFACE X
ARMORED MOUNTED PHOTO EYE I I 1
TURNSTILE OPERATORS AND AUTO DOOR OPERATOR LOOP DOOR
CONTACT 1 I 1 I
120V POWER (BY OTHERS) +18" 1 q
(BY OTHERS)
JUNCTION BOX X 1
11 I
I
1 ' ONDUIT X 1 1
PEDASTAL MOUNTED I 1
BADGE READER I I 1
0
72" 1
+42" I j
FIELD � — I I 1 " C.O.
VERIFY ADA DOOR 1 I 1 "PVC, C.O.
LOCATION +42" OPERATO —
1 I (3)1 "PVC, C.O.
I r I I
I I I
1 (2)1" C.O.
I 11 I I
1 "PVC, C.O. 1 1 1
3'x3' ❑-------�
HOFFMAN II
ENCLOSURE II TURNSTILE CONTROLLER 1 "
II
ELECTRIC I TO DATA CA I ET
II STRIKE
II PNL 05-430/5c PNL 05-430/11c 1
11 11 3/4"C, 2# 12, # 12G 3/4"C, 2# 12, # 12G J
--------
I 1 II II
I I I I II II II II II II I II
TO CARD READERS 11 A CONCRETE MANUFACTURER D ETA I E 2
1k y. L(L — ON UNSECURE SIDE-----------�� RECOMMENDED (102"X72"X4") = E6E5 1 10
TO POWER ----------------------- SCALE: 1" 2'-405641
SOURCE
TURNSTILE ELEVATION VIEW 76 ARCEL 4 ISSUE FOR CONSTRUCTION CECASNEEngineering
545 FACTORIA BOULEVARD SE, SUITREMOVAL E 200
SCALE: NTS XXE510 FEBRUARY 08 2019 BELLEVUE, WA 98006
(425) 522-1000 WWW. CASNE. COM JOB NO. 191-027
SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE L DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL A DATE 02.08.19
t�4w° WAS�I��'' HSC ESIGNB D/ R CH CKEDDC. ON 07.15.15 ELECTRICAL DETAILS - AMS AND SLIDING GATE
APRON C CI PROJECT W3441886 CASNE CEC 12.14.15 SPECIFICATION IS APPROVED SHEET
— RECORD DRAWING-737 MAX FLIGHTLINE UTILITIES W3441886 CASNE DAT 12.19.16 �O�,H� ® _ P OVED BY DEPT. DATE ENGINEER TITLE APRON C PARCEL 820 E51 OR E16
A APRON C PARCEL 820 CASNE CEC 02.08.19 CHECKED
35276 APPROVED APRON C JOB NO. COMP NO.
°� ��rsTER�° �',^,II W3441886
�SS'(ONAL � 2 CAI APPROVED ELECTRICAL MASTER RENTON, WA�7GNO. 05—APRON—C—E51 OR