Loading...
HomeMy WebLinkAboutzS-3996Set304 =06 302 2 8= 260 �262 7�0 AIRCI y 9'Q 9 "r I i SPRINKLER RISER ROOM PER RENTON STANDARD PLAN NO. 360.5 NO. SCALE: 1" = 50' 0 25 50 100 "O!!!� EX. INF/L TRAT/ON DETENTION VAULT USE THE EXISTING GA TE VAL VE TO ISOLA TE THE WATER MAIN AD✓ACENT TO BUILDING E DURING CONSTRUCTION CUT AND TAP EXISTING SEWER STUBS DURING DEMOLITION AND RECONNECT AT THE TIME OF BUILDING COMPLETION REMOVE EX. OIL/WATER SEPERATOR AND CONNECT W TO EX. SEWER STUB 0 PROVIDE 6" ROOF DRAIN TO EX. CATCHBASINS (TYP) ASPHAL T REPAIR PER C. O.R. STD. PLAN H032-1 (TYP) 4 CONNECT TO EXISTING WA TER MAIN AND PROVIDE NEW J14" DOMESTIC WATER SERVICE (TO BE INSTALLED SY THE CITY) PER C.O.R. STD. PLAN 320.1 WITH CAST IRON METER BOX EQUAL TO OL YMPIC FOUNDARY. A SEPARATE WATER PERMIT IS REQUIRED. STORM DRAIN INLET PROTECTION PER C.O.R. STDD, PLAN 216.30 (TYP) MARK EXISTING WA TER LINE TO ENSURE PROTECTION DURING CONSTRUCTION EXISTING FIRE HYRDRANT I REVISION SITE STA TIS TICS PARCEL NUMBER.• SITE ADDRESS - TOTAL SITE AREA: DISTURBED AREA. PROPOSED USE EXISTING ZONING.- CR/T/CAL AREAS.• RIGHT -OF -WA Y DEDICATION.• STRUCTURAL DESIGN CRITERIA: SHEET INDEX 1623059062, 1623059142, 1623059143, 162JO59144 2829 NE 3R0 STREET 333, 529 SF. (7.66 AC) 16,854 S.F. (0.39 AC) MINI WAREHOUSE IL -INDUSTRIAL - LIGHT NONE NONE SEE STRUCTURAL PLANS C1. 01 T. E. S. C. & UTILITY PLAN C1.02 STANDARD NOTES & DETAILS C1.03 BOUNDARY & TOPOGRAPHIC SURVEY L 1.01 LANDSCAPE PLAN 0 W z Q o = Q Q 900 STREET Q � N. 3R0 ST. 3Fp AIRPORT WY. N E � v Q S/ TE S. 2ND ST. 0,Py S JRD. ST. 167 Q 169 k GRAY WAY VICINITYMAP 515 0 o SCALE: 1 " = 2, 600' .z 330 320 310 Ex 0+50 24 HOUR EROSION CONTROL CONTACT TBD PERMIT NO C18000336 SURVEYED: RDW SCALE. HORIZONTAL NAD 1983/1991 DESIGNED: OF✓ 1 » = 50 DRAWN: OF✓ ONE INCH DATU M CHECKED: OF✓ AT FULL SCALE IF NOT ONE INCH BY DATE APPR APPROVED: LBH SCALE ACCORDINGLY 1+00 OWNER/APPLICANT GILROY FAMIL Y LLC 1614 118TH A VENUE SE SELLEVUE, WASHINGTON 98005 (425) 999-8250 CONTACT PATRICK GILROY LEGEND ENGINEER/SURVEY/ PLANNER CORE DESIGN INC 14711 N.E. 29TH PLACE, SUITE 101 BELLEWf,, WASHINGTON 98007 (425) 885-7877 CONTACT SHERI MURA TA, P. E. - ENGINEER ROBERT D. WEST, P.L. S. - SURVEYOR LAFE B. HERMANSEN - PLANNER @ STORM DRAIN INLET PROTECTION ® WATER VAULT ® TYPE 1 CATCH BASIN ♦ FIRE DEPT. CONNECTION Q) STORM DRAIN MANHOLE WATER VALVE G SANITARY SEWER MANHOLE Y FIRE HYDRANT O TELEPHONE MANHOLE IR WATER METER —W— WATER • EXISTING 1/2" REBAR W/YELLOW PLASTIC CAP —G— GAS "LS 37555 PER SHORT PLAT —T— TELEPHONE O FOUND CORNER MONUMENT -SD- STORM DRAIN AS NOTED —ss— SANITARY SEWER BASIS OF BEARING REF 1 BENCHMARK 1. CITY OF RENTON CONTROL PT. 11884 3--112" BRASS DISK STAMPED 71AFF--1990" ON CONC. MONUMENT. ELEV. 340.93 2. CITY OF RENTON CONTROL PT. 11502 4 " CONC. MONUMENT W 2" BRASS DISK & PUNCH A T INTERSECTION MONROE A VE. N. E. & N.E. 4TH (N114 COR. SEC. 16) ELEV. 341.39 LEGAL DESCRIPTION LOTS 1, 2, 3, AND 4 OF CITY OF RENTON SHORT PLAT N0. LUA-02-065-5HPL, RECORDED UNDER RECORDING NUMBER 20021217900004, BEING A PORTION OF THE NORTHWEST QUARTER OF THE NORTHWEST QUARTER OF SECTION 16, TOWNSHIP 23 NORTH, RANGE 5 EAST, W.M., IN KING COUNTY, WASHINGTON REFERENCES 1. RECORD OF SURVEY FOR STEVE HARER BY ✓OHN E. CRAMER RECORDED IN VOL. 127, PG. 98 REC. NO.. 9901269002. 3-20-16 CITY OF RENTON Planning/Building/Public Works Dept. 330 320 S-399601 310 WATER UTILITY i Abdoul Gafour 04/17/2018 � W-399601 i.so s.00 R-399601 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY Justin Johnson 04/16/2018 rstraka 04/16/2018 WASTEWATER UTILITY REGIONAL FIRE AUTHORITY Dki dchristen 04/16/2018OAPPROVEDcthomas 04/17/2018 "9 T.E.S.C. & UT/L/TYPLAN 1112118 THE STOR-HOUSE - PHASE /V PAGE: OOK: PAGE: G/LROYFAM/L YLLC 1614 118TH A VENUE SE SELLEWf,, WA 98005 DRAWING NO: C1.01 SHEET: 1 OF: 4