Loading...
HomeMy WebLinkAboutMFP19003221.pdfDEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Franchise Permit: MFP19003221 IVR Number: 19003221 Permit Informaon Permit Name:Century Link Permits Address/Locaon :06/12/2019Application Date:2144800500Parcel Number:8220 S 132ND ST Permit Type:06/14/2019Issue Date:Franchise Permit Work Class:06/13/2020Expiration Date:Minor Utility Job Number:N.541903Franchise Type:Telephone Description:Century Link to bore 80' across Renton ave S, trench 15', and access MH28. Restoration per City of Renton standards. APPROVED WITH COMMENTS OR REDLINES. Contacts Name Address PhoneTypeBilling C/O QWEST CORP 1801 CALIFORNIA ST #4600 Denver, CO 80202 Applicant Kim Parker QWest Corporation 931 14th St, Suite 1000A Denver, CO 80202 B: (303) 992-0752Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 CITY OF RENTON ROW 1055 S Grady Way Renton, WA 98057-3232 Owner QWest/Century Link - Billing 7850 S TRAFTON St TACOMA, WA 98409 Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐ New Construction ☐ Repair/Relocate ☐ Underground ☐ Overhead ☐ Sidewalk ☐ Street ☐ Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date Qwest Corp d/b/a CenturyLink N.541903 Austin Sweeney 253-766-7549 austin.sweeney@centurylink.com Intersection of S 132nd St & Renton Ave S CenturyLink to bore approx. 80' across Renton Ave S, trench approx 15', and access MH28. All other work to be done by the developer. North Sky Communications 503.582.1263 NORTHSC857Q4 BL.028638 6/12/19 4 Austin Sweeney MFP19003221 Scott Warlick 6/14/2019 RESTORATION PER CITY OF RENTON STANDARDS Justin Johnson 6-14-2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: N.541903 North Sky Communications 503.582.1263 Austin Sweeney 253.766.7549 23315 66th Ave S Kent, WA 98032 austin.sweeney@centurylink.com Intersection of S 132nd St & Renton Ave S 8:30 am to 3:30 pm Monday through Friday 6-14-2019 Reset FormPrint Form Austin Sweeney Austin Sweeney 6/12/19 MFP19003221 Justin Johnson SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). Comments: SIGN SPACING MPH "X"45+ 500' 35 350'30 200' 25 100'150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'ONE LANE TWO WAYTAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.541903 C.45 PERMIT # RENTON AVE S @ S 132ND ST BORE PITS -TRENCH -MH 28 UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:06/04/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.541903 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTH TAPER ('L') LANE WIDTH L MPH 10' 11' 12' SHIFTING 20 70 75 80 TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245SHOULDER 40 270 295 320 TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.541903 C.45Designed for CenturyLink bySharon MartosApproved 06/04/2019Traffic Control SupervisorTCS # 010745Expires: 5/30/2021Phone 253-737-5198sharon.martos@gmail.com Comments: SET UP BORE PITS 1 & 2 RENTON AVE S @ S 132ND ST. BORE FROM BP 1 -BP 2, TRENCH APPROX 15' TO MH 28. RIGHT LANE CLOSURE NB. LANE SHIFT SB. SIDEWALK ACCESSIBLE.SPOTTER WILL ASSIST PEDESTRIANS. Not to scaleNOT TO SCALE SPEED LIMIT 35 BP 1 BP 2 MH 28 WORK AREA 11 X 265 ROADWORKAHEADW20-1ROADWORKAHEADW20-1ROADWORKAHEAD W20-1 RIGHT LANECLOSEDAHEADW20-5W4-2LANESHIFTAHEADW5-5W1-4WORK AREA 11 X 155 RENTON AVE S S 132ND ST350'350'350' 350'350'350' 225' 115' N Legend Arrowboard (Chevron) Cone Not to scale Scale Marker Spotter Work Area Work Truck DWY www.invarion.com MFP19003221 left turn lane closed ahead will be required. detour will need to in place.Coordinate TCP with project on Renton Ave Comments: SIGN SPACINGMPH "X" 45+ 500'35 350' 30 200'25 100' 150' Seattle200' Sea TacComments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'ONE LANE TWO WAYTAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.541903 C.45 PERMIT # S 132ND ST @ RENTON AVE S P 902 ONE LANE 2-WAY UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:06/04/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.541903 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified.4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTHTAPER ('L') LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.541903 C.45 Designed for CenturyLink by Sharon Martos Approved 06/04/2019 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Comments: ACCESS POLE 902 SOUTH SIDE S 132ND ST, WEST OF RENTON AVE S. ONE LANE 2-WAY WITH FLAGGERS. NOTIFY PROPERTY OWNERS PRIOR TO START OF WORK REGARDING DRIVEWAY ACCESS. FLAGGERS WILL ASSIST PEDESTRIANS. Not to scaleNOT TO SCALE R E N T O N AV E S N ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bROADWORKAHEAD W20-1 BE PREPAREDTO STOP W20-7bROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aS 132ND ST Legend Cone flagger symbol Not to scale Scale Marker Work Area Work Truck 350' 350' SPEED LIMIT 35 WORK AREA 12 X 40 X W20-7a350'350' DWY DWY DWY P 902 www.invarion.com MFP19003221 Comments: SIGN SPACINGMPH "X" 45+ 500' 35 350'30 200' 25 100'150' Seattle200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'ONE LANE TWO WAY TAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.541903 C.45 PERMIT # S 132ND ST @ RENTON AVE S PED 8070 -P 89 ONE LANE 2-WAY UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:06/04/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.541903 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTHTAPER ('L') LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.541903 C.45 Designed for CenturyLink by Sharon Martos Approved 06/04/2019 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Comments: ACCESS PED 8070 & POLE 89 NORTH SIDE S 132ND ST, WEST OF RENTON AVE S.PLACE NEW DOWN GUY ON POLE. ONE LANE 2-WAY WITH FLAGGERS. FLAGGERS WILL ASSIST PEDESTRIANS. Not to scaleNOT TO SCALE R E N T O N AV E S N ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bROADWORKAHEAD W20-1 BE PREPAREDTO STOP W20-7bROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aS 132ND ST Legend Cone flagger symbol Not to scale Scale Marker Work Area Work Truck 350' 350' SPEED LIMIT 35 PED 8070 WORK AREA 12 X 95 X P 89 W20-7a350'350' www.invarion.com MFP19003221 Comments: SIGN SPACING MPH "X"45+ 500' 35 350' 30 200' 25 100'150' Seattle 200' Sea Tac Comments: CHANNELIZATION SPACING MPH TAPER TANGENT35 / 45 30' 60'25 / 30 20' 40'ONE LANE TWO WAY TAPER 50' TO 100' max TRAFFIC CONTROL PLAN JOB # N.541903 C.45 PERMIT # S 132ND ST @ RENTON AVE S PED 8232 ONE LANE 2-WAY UNLAWFUL FOR ANYONE OTHER THAN THE CITY OF RENTON TO ALTER THIS CERTIFIED TRAFFIC CONTROL PLAN IN ANY FORM WITHOUT EXPRESS WRITTEN CONSENT FROM: SHARON MARTOS, TCS# 010745 sharon.martos@gmail.com Date:06/04/2019 Author:Sharon Martos, Traffic Control Supervisor Project:N.541903 C.45 CERT:TCS # 010745 CENTURYLINK:Certified Traffic Control Plan (DO NOT ALTER) Comments: General Requirements 1. All signs and spacing to conform to the MUTCD and CITY OF RENTON requirements. 2. Channelizing devices are 28" traffic cones with retroreflective material. 3. All signs are 48" x 48" B/O unless otherwise specified. 4. Alert affected local residents and businesses. 5. Crew is required to leave a minimum of 11' for lane width. 6. Work hours will be ____am to ____pm. Comments: MERGING TAPER LENGTHTAPER ('L') LANE WIDTH L MPH 10' 11' 12'SHIFTING 20 70 75 80 TAPER 25 105 115 1651/2 L 30 150 165 180 35 205 225 245 SHOULDER 40 270 295 320TAPER 45 450 495 540 1/3 L Sharon Martos Project # N.541903 C.45 Designed for CenturyLink by Sharon Martos Approved 06/04/2019 Traffic Control Supervisor TCS # 010745 Expires: 5/30/2021 Phone 253-737-5198 sharon.martos@gmail.com Comments: ACCESS PED 8232NORTH SIDE S 132ND ST, WEST OF RENTON AVE S. ONE LANE 2-WAY WITH FLAGGERS. FLAGGERS WILL ASSIST PEDESTRIANS. Not to scaleNOT TO SCALE R E N T O N AV E S N ROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aROADWORKAHEAD W20-1 BE PREPAREDTO STOP W20-7b W20-7aROADWORKAHEADW20-1BE PREPAREDTO STOPW20-7bW20-7aS 132ND ST Legend Cone flagger symbol Not to scale Scale Marker Work Area Work Truck 350'350' 350' 350' 350' 350' SPEEDLIMIT 35 PED 8232WORK AREA 12 X 90 DWY www.invarion.com MFP19003221 Existing CTL MH #28 (feed for both copper & fiber) Existing Pedestal #8232 (sweep 1-4” conduit in/out) Existing Pedestal #8070 (intercepts feed crossing S 132nd) Place 1-4” from pedestal #8070 to pole P #89 Pole P #89 (will require new down guy to east) Place 264TA HH (note: can adjust location if required) Place 1-4” from HH into site for future feed Place 2-4” from P #89 to HH Place 2-4” from MH #89 to 264TA HH (note: sweep 1 duct in/out of pedestal #8232 / 1 duct straight through) Place 1-4” from pedestal #8232 to P #902 Pole #902 Bore across Renton Ave S, then trench approximately 15’ to MH All structure to be provided and placed by developer with the exception of the Renton Ave S crossing (see next page) CTL will pull new cable after structure is in place allowing for aerial facilities along the north side of S 132nd St to be removed. MFP19003221 Bore across Renton Ave S Place 2-4” conduits CenturyLink to schedule this structure placement CTL MH #28 Trench from end of bore pit approximately 15’ to vault Place 2-4” conduits MFP19003221