HomeMy WebLinkAboutCA_Prescriptive-Worksheet-Both-Zones_181029_v2PR16000315 B18006362 RECEIVED 11/19/2018 lwalker BUILDING DIVISION 3.5 Window, Skylight and Door Schedule Project Information Contact Information Width Height Ref. U-factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)0.0 0.00 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA 0.0 0.00 0.30 1 8 0 5 0 40.0 12.00 0.30 1 10 0 8 0 80.0 24.00 0.26 1 3 0 5 0 15.0 3.90 0.30 1 8 0 5 0 40.0 12.00 0.0 0.00 0.0 0.00 0.30 1 5 0 5 0 25.0 7.50 0.26 2 2 6 2 0 10.0 2.60 0.26 1 2 6 6 0 15.0 3.90 0.26 1 2 6 2 0 5.0 1.30 0.26 2 3 0 5 0 30.0 7.80 0.26 1 2 0 4 0 8.0 2.08 0.26 3 3 0 5 6 49.5 12.87 0.30 1 8 0 8 0 64.0 19.20 0.26 2 6 0 5 0 60.0 15.60 0.27 4 3 0 2 0 24.0 6.48 0.30 1 6 0 8 0 48.0 14.40 0.26 3 6 0 5 0 90.0 23.40 0.27 6 3 0 2 0 36.0 9.72 0.30 1 4 6 4 0 18.0 5.40 0.0 0.00 0.0 0.00 0.26 2 2 0 5 6 22.0 5.72 0.30 1 4 0 4 0 16.0 4.80 0.26 1 2 0 5 6 11.0 2.86 0.30 1 6 0 5 6 33.0 9.90 0.26 2 3 0 5 6 33.0 8.58 0.26 1 5 0 1 4 6.7 1.73 0.27 1 3 0 5 0 15.0 4.05 0.26 3 6 0 5 0 90.0 23.40 0.26 6 3 0 5 6 99.0 25.74 0.26 2 3 0 5 0 30.0 7.80 0.30 1 8 0 5 0 40.0 12.00 0.26 2 2 0 5 6 22.0 5.72 Lakeview L430-B QUADRANT HOMES 14725 SE 36TH ST BELLEVUE, WA 98006 BASEMENT FLOOR PLAN Rec Rm 8050 XOX Rec Rm 10080 SGD Gym/ Bdrm 6 3050 FG Gym/Bdrm 6 8050 XOX FIRST FLOOR PLAN Guest Bdrm 5050 SL Guest Bdrm 2620 FG Foyer 2660 FG Foyer 2620 FG Foyer/Stairs 3050 FG Stairs/Hall 2040 FG Study 3056 FG Study 8080 SGD Great Rm 6050 FG Great Rm 3020 AWN Mulled Dining 6080 SGD Dining 6050 FG Dining 3020 AWN Mulled Hall Bath 5014 FG Bdrm #4 3050 CSMT Valet 4640 SL SECOND FLOOR PLAN Bdrm #3 2056 FG Bed #2 & #3 Hallway 4040 SL Exempt Glazed Fenestration (15 sq. ft. max.) "Open to Below (2)" 6050 FG Stairs 3056 FG Loft 3050 FG Loft 8050 XOX Mstr Bdrm 2056 FG Bdrm #2 2056 FG Bdrm #2 6056 SL Bdrm #2 3056 FG 0.30 1 8 0 5 6 44.0 13.20 0.26 5 2 6 5 0 62.5 16.25 0.0 0.00 0.0 0.00 0.0 0.00 0.14 1 3 0 8 0 24.0 3.36 0.0 0.00 Sum of Vertical Fenestration Area and UA 1205.7 329.26 Vertical Fenestration Area Weighted U = UA/Area 0.27 Overhead Glazing (Skylights) Component Width Height Description Ref. U-factor Qt. Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 1205.7 329.26Total Sum of Fenestration Area and UA (for heating system sizing calculations) Foyer Front Door 3080 SC Mstr Bdrm 8056 XOX Mstr Bath 2650 FG First Floor Plan Simple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions Design Temperature Difference (∆T) 46 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 4,301 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)9.0 38,709 Glazing and Doors U-Factor X Area = UA Instructions 0.30 1,206 361.71 Skylights U-Factor X Area = UA Instructions 0.50 --- Insulation Attic U-Factor X Area = UA Instructions 0.026 2,181 56.71 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No selection --- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 4,293 240.41 Floors U-Factor X Area UA Instructions 0.025 4,228 105.70 Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Location of Ducts Instructions Duct Leakage Coefficient 1.00 Sum of UA 764.52 Envelope Heat Load 35,168 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 19,231 Btu / Hour Volume X 0.6 X ∆T X .018 Building Design Heat Load 54,399 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 54,399 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 76,158 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Lakeview L430-06LC Elevation B Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13)