HomeMy WebLinkAboutCA_Letter from Engineer_190305_v219011 Wood-Sno Road NE, Suite 100 Woodinville, WA 98072-4436 Phone: (425) 814-8448 Fax: (425) 821-2120 BTL ENGINEERING PROJECT RECORD Date: October 31, 2018 To: Quadrant Homes 14725 SE 36th Street Bellevue, WA 98006 Attn: Tatyana Sirotisnky From: Brian Lampe Plan: Lakeview (Lots 14 and 17) Pages: 2 RE: Prescreening Checklist Tatyana, The following addresses the outstanding prescreening checklist items from the City of Renton. Note that there is no permit intake reference number as this is a generic screening: Structural 3. Lateral calcs sheet L2.9: d. The truss temporary and permanent bracing shall be per IRC Sections 502.11.2 and 802.10.3 as well as the Truss Plate Institute’s Building Component Safety Information. The truss manufacturer shall provide the bracing information so have them coordinate. The building department may require the truss shop drawings along with the submittal or they may allow a deferred submittal. See Note 6.5, item N. on S1.1 of the structural drawings. e. Truss alteration shall not occur unless the approval of a design professional as indicated in IRC Sections 502.11.3 and 802.10.4. The truss manufacture’s documents should include this information. I have added to the end of Note 6.5, highlighting that the trusses shall not be modified. 6. Joists shall be laterally supported at the ends by full-depth solid blocking not less than 2 inches nominal in thickness; or by attachment to a full-depth header, band or rim joist, or to an adjoining stud to provide lateral support to prevent rotation. Additionally, in Seismic Design Categories D0, D1 and D2, lateral restraint shall be provided at each intermediate support. The drawings do not indicate this requirement. Please revise the drawings to include this requirement and resubmit the drawings for review. See IRC Sections 106.1.1 and 502.7. Note that the framing is designed in accordance with IBC which supersedes the IRC so Seismic Design Categories D0, D1 and D2 don’t exist and is replaced by Seismic Design Category D. The drawings properly show the joist bracing. Note that the floor systems used are trusses (upper floor) and I-Joists (main floor) and are subject to the manufacturer’s recommendation in accordance with Exception 1. 8. Simpson SDS screws… Note that the framing is designed in accordance with IBC so the IRC tables have been superseded by design.  Deck ledger demand load is (60psf + 10psf) x (9.75ft/2) = 341#/ft  Capacity of deck ledger detail shown in 17/S3.3 is (2 rows SDWS22400DB screws @ 12”oc) = 385#/screw x 2 screws/ft = 700#/ft  Alternately, the Simpson table referenced shows maximum 7”oc screw spacing for a 10-ft span. We have equivalent of 6”oc and a 9’-9” span.  Note these screws have a “double barrier coating” equivalent to ASTM A153. See also note 6.9 on S1.1. RECEIVED 11/16/2018 aalexander BUILDING DIVISION PR16000315 B18006356 V2 REVISION Received: 03/06/2019 / aalexander BUILDING DIVISION APPROVED BUILDING DIVISION THIS SET OF APPROVED PLANS MUST BE ON THE JOB AT ALL TIMES DURING CONSTRUCTION. THIS BUILDING IS NOT TO BE OCCUPIED UNTIL AFTER FINAL INSPECTION BY THE RENTON BUILDING DIVISION AND RECEIPT OF CERTIFICATE OF OCCUPANCY. APPROVAL SHALL NOT BE CONSTRUED AS THE AUTHORITY TO VIOLATE OR CANCEL ANY PROVISIONS OF CODES, ORDINANCES, OR OTHER REGULATIONS ENFORCED BY THIS CITY. DATE: 04/24/2019  Page 2 9. Detail 16/S3.4 indicates a pinned connection at the gable end of the wall… Detail 16/S3.4 shows GWB ceiling bracing the top of the wall. No diagonal bracing is required. GWB is capable of supporting 35-plf (seismic) and 70-plf (wind) in accordance with IBC Table 2508.5. Load demand at top of wall is 34-plf (seismic: 5psf x 13.5ft/2) and 68-plf (wind: 10psf x 13.5ft/2). 10. Our review indicates that a “flat” 2x member, e.g.; 2x6, needs to be connected to the 2x diagonal wood bracing… This will not apply. We don’t have bracing at the wall top plate. Bracing for the gable studs, as required, will be less than 6’-3” as the maximum gable height is 4’-6”. 11. The drawings do not indicate lateral load attachments of the decks to the house… Lateral load is resolved with the ledger decking. As the deck is nestled in the main house recess, pull-out due to rotation is unlikely. However, the ledger connection parallel to the deck joists resolves pull-out at one end and we added a DTT1Z to resolve pull-out at the open end. A theoretical demand on the pull-out is 50# (2850# x 0.15 x 0.7 x 9.75ft/2 I 29ft). Capacity of side ledger (for pull-out) is 5390# (385#/screw x 2 screws/ft x 7ft). Pull-out capacity of DTT1Z w/ SDWH and (3)SD#9 = 420#. Please call if you have any questions. Sincerely, Brian Lampe, P.E., S.E. BTL Engineering