Window, Skylight and Door Schedule
Project Information Contact Information
Width Height
Ref. U-factor Qt. Feet
Inch Feet Inch Area UA
Exempt Swinging Door (24 sq. ft. max.)0.0 0.00
0.0 0.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref. U-factor Qt. Feet
Inch Feet Inch Area UA
0.0 0.00
0.30 1 8
0 5 0 40.0 12.00
0.30 1 10
0 8 0 80.0 24.00
0.26 1 3
0 5 0 15.0 3.90
0.30 1 8
0 5 0 40.0 12.00
0.0 0.00
0.0 0.00
0.30 1 5
0 5 0 25.0 7.50
0.26 2 2
6 2 0 10.0 2.60
0.26 1 2
6 6 0 15.0 3.90
0.26 1 2
6 2 0 5.0 1.30
0.26 2 3
0 5 0 30.0 7.80
0.26 1 2
0 4 0 8.0 2.08
0.26 3 3
0 5 6 49.5 12.87
0.30 1 8
0 8 0 64.0 19.20
0.26 2 6
0 5 0 60.0 15.60
0.27 4 3
0 2 0 24.0 6.48
0.30 1 6
0 8 0 48.0 14.40
0.26 3 6
0 5 0 90.0 23.40
0.27 6 3
0 2 0 36.0 9.72
0.30 1 4
6 4 0 18.0 5.40
0.0 0.00
0.0 0.00
0.26 2 2
0 5 6 22.0 5.72
0.30 1 4
0 4 0 16.0 4.80
0.26 1 2
0 5 6 11.0 2.86
0.30 1 6
0 5 6 33.0 9.90
0.26 2 3
0 5 6 33.0 8.58
0.26 1 5
0 1 4 6.7 1.73
0.27 1 3
0 5 0 15.0 4.05
0.26 3 6
0 5 0 90.0 23.40
0.26 6 3
0 5 6 99.0 25.74
0.26 2 3
0 5 0 30.0 7.80
0.30 1 8
0 5 0 40.0 12.00
0.26 2 2
0 5 6 22.0 5.72
Lakeview L430-B QUADRANT HOMES
14725 SE 36TH ST
BELLEVUE, WA 98006
BASEMENT FLOOR PLAN
Rec Rm 8050 XOX
Rec Rm 10080 SGD
Gym/ Bdrm 6 3050 FG
Gym/Bdrm 6 8050 XOX
FIRST FLOOR PLAN
Guest Bdrm 5050 SL
Guest Bdrm 2620 FG
Foyer 2660 FG
Foyer 2620 FG
Foyer/Stairs 3050 FG
Stairs/Hall 2040 FG
Study 3056 FG
Study 8080 SGD
Great Rm 6050 FG
Great Rm 3020 AWN Mulled
Dining 6080 SGD
Dining 6050 FG
Dining 3020 AWN Mulled
Hall Bath 5014 FG
Bdrm #4 3050 CSMT
Valet 4640 SL
SECOND FLOOR PLAN
Bdrm #3 2056 FG
Bed #2 & #3 Hallway 4040 SL
Exempt Glazed Fenestration (15 sq. ft. max.)
"Open to Below (2)" 6050 FG
Stairs 3056 FG
Loft 3050 FG
Loft 8050 XOX
Mstr Bdrm 2056 FG
Bdrm #2 2056 FG
Bdrm #2 6056 SL
Bdrm #2 3056 FG
0.30 1 8
0 5 6 44.0 13.20
0.26 5 2
6 5 0 62.5 16.25
0.0 0.00
0.0 0.00
0.0 0.00
0.14 1 3
0 8 0 24.0 3.36
0.0 0.00
Sum of Vertical Fenestration Area and UA 1205.7 329.26
Vertical Fenestration Area Weighted U = UA/Area 0.27
Overhead Glazing (Skylights)
Component Width Height
Description Ref. U-factor Qt. Feet
Inch Feet Inch Area UA
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Overhead Glazing Area and UA 0.0 0.00
Overhead Glazing Area Weighted U = UA/Area 0.00
1205.7 329.26Total Sum of Fenestration Area and UA (for heating system sizing calculations)
Foyer Front Door 3080 SC
Mstr Bdrm 8056 XOX
Mstr Bath 2650 FG
First Floor Plan
Simple Heating System Size: Washington State
Project Information Contact Information
Heating System Type:
To see detailed instructions for each section, place your cursor on the word "Instructions".
Design Temperature
Instructions Design Temperature Difference (∆T) 46
∆T = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft) 4,301
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height (ft)9.0 38,709
Glazing and Doors U-Factor X Area = UA
Instructions
0.30 1,206 361.71
Skylights U-Factor X Area = UA
Instructions 0.50 ---
Insulation
Attic U-Factor X Area = UA
Instructions 0.026 2,181 56.71
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions No selection ---
Above Grade Walls (see Figure 1)U-Factor X Area UA
Instructions 0.056 4,293 240.41
Floors U-Factor X Area UA
Instructions 0.025 4,228 105.70
Below Grade Walls (see Figure 1)U-Factor X Area UA
Instructions No selection ---
Slab Below Grade (see Figure 1)F-Factor X Length UA
Instructions No selection ---
Slab on Grade (see Figure 1)F-Factor X Length UA
Instructions No selection ---
Location of Ducts
Instructions Duct Leakage Coefficient
1.00
Sum of UA 764.52
Envelope Heat Load 35,168 Btu / Hour
Sum of UA X ∆T
Air Leakage Heat Load 19,231 Btu / Hour
Volume X 0.6 X ∆T X .018
Building Design Heat Load 54,399 Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load 54,399 Btu / Hour
Ducts in unconditioned space: Sum of Building Heat Loss X 1.10
Ducts in conditioned space: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 76,158 Btu / Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA Manuals
J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30.
The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC.
Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at
(360) 956-2042 for assistance.
Lakeview
L430-06LC
Elevation B
Above Grade
Below Grade
Figure 1.
All Other Systems Heat Pump
(07/01/13)