Loading...
HomeMy WebLinkAboutR-405411V ) 0 Z Q J r= V 2 W 2 I- Q U) rr 0 W U w 0 0 z fr LL m LANDING GRADE BREAK - SEE CONTRACT PLANS - 4'- V MIN. CEMENT CONCRETE SIDEWALK - SEE NOTE 5 FLARE (TYP.) 3/8" EXPANSION JOINT (TYP.) - SEE STANDARD PLAN F-30.10 GRADE BREAK A CURB RAMP WIDTH 4'- W MIN. LANDING TO MATCH CURB RAMP WIDTH - SEE CONTRACT PLANS LANDING I GRADE BREAK CURB RAMP SEE CONTRACT PLANS - CEMENT CONCRETE _ 4'- 0" MIN. SIDEWALK - SEE NOTE 5 PROVIDE SMOOTH TRANSITION TO SIDEWALK WIDTH Y (TYP) SEE CONTRACT PLANS - - * 4'- 0" MIN. ..........; W13" EXPANSION JOINT (TYP.) -SEE r I CURB RAMP STANDARD PLAN F-30.10 I GRADE BREAK TRANSITION TO SIDEWALK BUF�� PRESENT, OR TO BACK OF CURB (TYP) - - ......... ......... ..... iii.....�EE'::E:i * * SEE CONTRACT PLANS :::::::::......... %! CURB, OR CURB .............. : AND GUTTER - CURB, OR CURB SEE NOTE 4 AND GUTTER - - DETECTABLE WARNING SURFACE - SEE NOTE 4 B SEE STANDARD PLAN F-45.10 FACE OF CURB FACE OF CURB - MEASURED PARALLEL DEPRESSED CURB AND GUTTER - TO CURB (TYP.) CROSSWALK SEE NOTE 4 10 CONTRACTION JOINT (TYP) - SEE STANDARD PLAN F-30,10 FOR CURB RAMP LENGTHS GREATER THAN 8'- D" PROVIDE SE 1/4 SECTION 14, TOWNSHIP 23 N, RANGE 5 E, W.M. CEDARS A T THE HIGHLANDS A NOTES CURB RAMP WIDTH 4' - 0" MIN. 1. At marked crosswalks, the connection between the curb ramp and the road - LANDING E MATCH CURB RAMP I WIDTH -SEE CONTRACT PLANS way must be contained within the width of the crosswalk markings. Y I 2. Where "GRADE BREAK' is called out, the entire length of the grade break GRADE BREAK between the two adjacent surface planes shall be flush. 3. Do not place Gratings, Junction Boxes, Access Covers, or other appurten- ances on any part of the Curb Ramp or Landing, or in front of the Curb Ramp where it connects to the roadway. MIN. SEE CONTRACT 4. See Contract Plans for the curb design specified. See Standard Plan PLANS - 4'- D" MIN. * F-10.12 for Curb, Curb and Gutter, Depressed Curb and Gutter, and BUFFER WIDTH -MATCH Pedestrian Curb details. TO CURB RAMP DEPTH I "(TYP.) 5. See Standard Plan F-30.10 for Cement Concrete Sidewalk Details. See I v, Contract Plans for width and placement of sidewalk. 6. The Bid Item "Cement Concrete Curb Ramp Type _" does not include the adjacent Curb, Curb and Gutter, Depressed Curb and Gutter, Pedestrian w Curb, or Sidewalks. ........ ........ 7. The Curb Ramp length is not required to exceed 15 feet (unless shown CEMENT CONCRETE otherwise in the Contract Plans). When applying the 15-foot max. length, PEDESTRIAN CURB SEE NOTE 4 the running slope of the Curb Ramp is allowed to exceed 8.3%. Use a single constant slope from bottom of ramp to top of ramp to match into DETECTABLE WARNING SURFACE - the landing over a horizontal distance of 15 feet. Do not Include the SEE STANDARD PLAN F-45.10 abutting landing in the 15-foot max. measurement. - DEPRESSED CURB AND GUTTER 8. Curb Ramps and Landings shall receive a broom finish. See Standard CROSSWALK Specifications 8.14. 9. Pedestrian Curb may be omitted if the ground surface at the back of the Curb Ramp and/or Landing will be at the same elevation as the Curb Ramp or Landing and there will not be material to retain. PLAN VIEW CONTRACTION JOINT EQUALLY SPACED 4'- 0" MIN. OC. PLAN VIEW TYPE PERPENDICULAR TYPE PERPENDICULAR B DETECTABLE WARNING SURFACE -- _ (SHOWN WITH BUFFER) SEE STANDARD PLAN F-45.10 4'- W MIN. 16 - 0" MAX. (TYP.) GRADE BREAK SLOPE TREATMENT - SEE CONTRACT PLANS SEE NOTE 7 COUNTER SLOPE - SEE STANDARD PLAN F-30.10 - _ GRADE BREAK S III MAX. * TOP OF ROADWAY � P P LANDING CURB RAMP DEPRESSED CURB AND GUTTER - 1 SEE STANDARD PLAN F-10.12 SECTION OA CEMENT CONCRETE CEMENT CONCRETE CURB RAMP "TYPE CEMENT CONCRETE CURB RAMP "TYPE PEDESTRIAN CURB - PERPENDICULAR "A" PAY LIMIT - SEE NOTE 6 PERPENDICULAR "B" PAY LIMIT SEE NOTE 4 DETECTABLE WARNING SURFACE - SEE STANDARD PLAN F415.10 3" R. TYP. 1 DEPRESSED CURB AND GUTTER - SEE NOTE 4 CEMENT CONCRETE CURB AND GUTTER -SEE NOTE 4 CURB RADIUS DETAIL OB ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT LEGEND - SLOPE IN EITHER DIRECTION 1.5 OR FLATTER RECOMMENDED FOR DESIGNIFORMWORK (2% MAX.) * * 7.5% OR FLATTER RECOMMENDED FOR DESIGNIFORMWORK (8.3% MAX.) * 9.5% OR FLATTER RECOMMENDED FOR DESIGN/FORMWORK (10% MAX.) ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT oV WASIj, QW �0 28680 �01 S TBR$ g� �s/®NAL Jun 24 2016 7:20 AM CAP PERPENDICULAR CURB RAMP STANDARD PLAN F-40.15-03 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Carpcii�,,.1"rf eQ1L/iCM�L, Jun 29 2016 229 PM BiATE DESIGN ENGINEER 0 Washington State Deportment or Transportation NOTES aB 1. The Detectable Warning Surface (DWS) shall extend the full width of the curb ramp, E MIN. MAX DETECTABLE WARNING landing, or other roadway entrance as applicable. Exception: If the Manufacturer of CURB RAMP, LANDING, CUT - SURFACE (DWS) - the DWS requires a concrete border around the DWS, a variance of up to 2 inches A 1.60" 2.40" THROUGH OR WALKWAY SEE NOTE 3 on each side of the DWS is permitted. 11 B 0.65" - 2, The Detectable Warning Surface (DWS) shall be placed at the back of curb, with the A D a 0.46" 0.80" two leading corners of the DWS panel placed adjacent to the back of the curb, and with no more than a 2 inch gap between the DWS and the back of the curb measured D 0.V 1.40" BACK OF CURB - TRUNCATED DOME SEE NOTE 2 ` - c::"i.:::::: \ 2' - 0" MIN. - at the center of the DWS panel. Exception: If the Manufacturer of the selected DWS E o.2^ 0.2^ ...:....:::,:: TYP. OF ALL requires a concrete border around the DWS, a variance of up to 2 inches from the SECTION O APPLICATIONS TRUNCATED DOME SPACING. SEE NOTE 3 SEE STANDARD SPECIFICATIONS FOR COLOR OF SURFACE TRUNCATED DOME DETAILS W Y 4LL LANDING � m OFFSET CURB RAMP -,.� , SEE NOTE B _ WIDTH OF WALKWAY , ::: WALKWAY WALKWAY ii DETECTABLE WARNING SURFACE (DWS) - �\ SEE NOTE 4 - - BACK OF CURB SINGLE DIRECTION CURB RAMP (GRADE BREAK BETWEEN CURB AND LANDING15 5 FT. FROM BACK OF CURB) (SEE NOTE 6) WAL back of the curb is permitted (measured at the leading corners of the DWS panel). 3. The rows of truncated domes shall be aligned to be perpendicular to the grade j' break at the back of curb. 4. The rows of truncated domes shall be aligned to be parallel to the direction of travel. CURB AND GUTTER MATCH TO WIDTH OF CURB RAMP, LANDING, CUT -THROUGH OR 5. If curb and gutter are not present, such as a shared -use path connection, the WALKWAY Detectable Warning Surface shall be placed at the pavement edge. DETECTABLE WARNING SURFACE DETAIL 6. See Standard Plans for sidewalk and curb ramp details. 7. If a curb ramp is required, the location of the Detectable Warning Surface must be at LANDING the bottom of the ramp and within the required distance from the rail. 8. When the grade break between the curb ramp and the landing is less than or equal to WALKWAY WIDTH OF CUT- 5 ft. from the back of curb at all points, place the Detectable Warning Surface on the / THROUGH (TYP.) bottom of the curb ramp directly above the grade break. .r �C WIDTH OF CUT -THROUGH CURB RAMP ::?!;: 11 (TYP.) lZ,i FLARE ::: FLARE 7-(":i:::r.: -2'-0"MIN. / DETECTABLE WARNING I �� DETECTABLE WARNING X` LANDING BACK OF CURB - J! SURFACE (DWS) - SURFACE DIRECTION OF SEE NOTE 2 (TYP-) -, SEE NOTE 3 ) SEE NOTE 3 _ WIDTH OF CURB RAMP _ BACK OF CURB - BACK OF CURB - SEE NOTE 2 )ERPENDICULAR CURB RAMP I SEE NOTE z 111 (SEE NOTE 6) 1�_- ;=Y;;pi� j �`:........2, _ 0„ MIN. WIDTH OF CURB RAMP, ISLAND CUT -THROUGH ; LANDING, OR WALKWAY DETECTABLE WARNING , �'If" S U R FACE (TYP.) - �'lr SEE NOTE 3 ` pN WASJfr i / ::• :::::: K h.. BACK OF CURB - �' JiT SEE NOTE 2 MEDIAN CUT -THROUGH ' SINGLE DIRECTION CURB RAMP WIDTH OF SHARED- _. DETECTABLE WARNING - o iv i r I ! - 'I (GRADE BREAK BETWEEN CURB AND SURFACE (DWS) - � ' I i 1 I USE PATH OR - �� �C 2esa0 -Q .�5 LANDING > 5 FT FROM BACK OF CURB) SEE NOTES 4 & 7 ` v m t' G d & TFw ' o W I TRAVEL SEE NOTE 2 WIDTH OF WALKWAY 3LE WARNING (DWS) - SEE NOTE 3 (SEE NOTE 6) CURB RAMP CURB RAMP WALKWAY LANDING WALKWAY DETECTABLE WARNING BACK OF CURB - SURFACE (DWS) - SEE NOTE 3 SEE NOTE 2 WIDTH OF LANDING PARALLEL CURB RAMP (SEE NOTE 6) r � Cd 2 Working Days Before You Dig 811 Utilities Underground Location Center (ID,MT,ND,OR,WA) `,- PATH OR WALKWAY PEDESTRIAN RAILROAD CROSSING PIE of WAS71 C, r� 53232 _ �SSIDNAL ���~ b�p•lg WALKWAY (TYP.)'I's C Her, Scott WIDTH OF CUT -THROUGH SHARED -USE Jul 12 2016 4:25 I'M (TYP.) PATH OR WALKWAY DETECTABLE WARNING ROUNDABOUT SPUTTER SURFACE ISLAND PAVEMENT SHOULDER EDGE `•;:;;;; STANDARD PLAN F-45.10-02 SHEET 1 OF 1 SHEET ti DETECTABLE WARNING APPROVED FOR PUBLICATION SURFACE (DWS) - =� caTpma,:«vr SEE NOTES 4 & 5 TO is znl6 zr,x6 PM i STATE DESIGN ENGINEER Aft PLACEMENT GUIDELINES SHARED -USE PATH CONNECTION WasStale Stle Depaltmsnt of Transportation D.R. STRONG CONSUL TING ENGINEERS ENGINEERS PLANNERS SURVEYORS 620 - 7th AVENUE KIRKLAND, WA 98033 O 425 827 3063 F 425 827 2423 1 CITY COMMENTS 02.19.19 1 CITY COMMENTS 05.03.19 NO. I REVISION 1.5" RADIUS B (TYP.) A C O UAW o Dif � \ l D E 0.3" BORDER (TYP.) Ali SIGN DIMENSIONS SIGN TYPE A B C D E POST MOUNTED STREET NAME SIGN (SPEED LIMIT <40MPH) 8„ VARIES 6" 4.5" 3.5" POST MOUNTED STREET NAME SIGN (SPEED LIMIT >40MPH) 12" VARIES 8" 6" 5" GENERAL NOTES: 1. FONT SHALL BE MUTCD D SERIES, UNLESS AN ALTERNATE MUTCD SERIES IS APPROVED BY THE CITY 2. LETTERS AND NUMERALS SHALL BE CUT FROM 3M ELECTROCUT FILM SERIES 1170 OR APPROVED EQUAL 3. SIGN BLADE SHALL BE FLAT ALUMINUM, TREATED, 0.080 GAUGE 4. SIGN SHEETING SHALL BE 3M HIGH INTENSITY PRISMATIC OR APPROVED EQUAL 5. SIGN MOUNTING HARDWARE SHALL INCLUDE BOLTS, RIVETS SHALL NOT BE ALLOWED 6. FOR SIGN POST DETAILS, SEE CITY OF RENTON STANDARD DETAIL 129, EXCEPT MOUNTING HEIGHT SHALL BE 9'-0" COLORS LEGEND, ARROW HEAD, SEPARATION BAR - WHITE (REFL.) BACKGROUND - GREEN (REEL.) Gti"C O POST MOUNTED PUBLIC WORKS STREET NAME SIGNS DEPARTMENT "BAND OR MOUNTING ON EXISTING METAL POLE OR LUMINAIRE 4" MIN. T EDGE OF GALVANIZED BOLT WITH GALVANIZED WASHERS. TUB LINE _n�TD. PLAN- 134 APPROVED: 7/30/2018 4:0 (iL DATE NOTES 1. DIMENSIONS FOR THE PARTS USED TO ASSEMBLE THE BASE CONNECTIONS ARE INTENTIONALLY NOT SHOWN. BASE CONNECTIONS ARE PATENTED, MANUFACTURED PRODUCTS THAT ARE IN COMPLIANCE WITH NCHRP 350 CRASH TEST CRITERIA. THE BASE CONNECTION DETAILS ARE SHOWN ON THIS PLAN ONLY TO ILLUSTRATE HOW THE PARTS ARE ASSEMBLED. 2. A 2" (IN) POST WITH A 2 1/4" (IN) PSST ANCHOR OR A 2 1/4" (IN) POST WITH A 2 1/2" (IN) PSST ANCHOR MAY BE SUBSTITUTED. SEE CONTRACT PLANS. 3. PERFORATED SQUARE STEEL POST SHALL MEET THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATION 9-06. 4. USE ONLY BASE CONNECTION MANUFACTURER SUPPLIED HARDWARE THAT MEETS THE REQUIREMENTS OF WSDOT STANDARD SPECIFICATIONS 9-06 AND 9-28. EDGE OF TRAVELED ROADWAY 90' FOR REFLECTORIZED SIGNS: MOUNT FACING 3-(degree) OUTWARD IF SIGN IS WITHIN 30 FEET OF ROADWAY SIGN FACE ORIENTATION ST 0 N 5416% (IN) T SHOULDER NUT AND W 2 REQUIRED BOLTFOR S SIGN PO LOWER SIG CORNER BOLT POST SUPPOR )FLANGED IBO LT WITH ASHERS ^ (TYP.) ST OP IGN POST TYPE ST-4 SIGN SUPPORT LOWER SIGN POST SUPPORT - 2.25" N.(IN), 7-GAGE, HOT -DIP GALVN�., IHEAVY-DUTY ANCHOR IAM. COMMERCIAL CONCRETE MOUNTING ON METAL POST SIGN MOUNTING ON SINGLE STD. PLAN- 129 ®� PUBLIC WORKS METAL POST APPROVED: f DEPARTMENT (ADOPTED) G-7 E NT O ns•re DRD 04.11.19 YLP SURVEYED: JGR CYW 06.20.19 YLP DESIGNED: YLPDRAWN: GLB CHECKED: YLP BY DATE APPR APPROVED SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CONSTRUCTION NOTES: 1. ALL TRANSPORTATION INFRASTRUCTURE FEATURES ARE TO BE MAINTAINED ON LEVEL GRADE IF THE SURFACE LEVEL FROM CONSTRUCTION IS CHANGED (I. E. JUNCTION BOXES, LUMINAIRE POLES, TRAFFIC SIGNAL POLES, SIGN POSTS) 2. ALL OTHER TRANSPORTATION INFRASTRUCTURE SHALL BE PROVIDED TO BE ON LEVEL GRADE ONCE CONSTRUCTION IS COMPLETE. 3. ALL EXISTING OR PROPOSED TRANSPORTATION FEATURES WITHIN THE PROJECT CONSTRUCTION LIMITS SHALL MEET CURRENT ADA STANDARDS (I.E. JUNCTION BOXES SHALL HAVE NON-SKID LIDS.) M� W T O O I T I Q J O C) T TRANSPORTATION NOTES STD. PLAN- 135 PUBLIC WORKS APPROVED: DEPARTMENT Zta l DAT C TY OF RENTON Planning/Building/Public Works Dept. :as��zs T-405402 z IN COMPLIANCE WITH CITY OF RENTON STANDARDS J 2 DEVELOPMENT ENGINEERINGAr% IL bbannwarth 07/01 /2019 _ W 2 DATE: Q CEDARS AT THE HIGHLANDS 01.29.19 STANDARD WSDOT RAMP AND STREET SIGN DETAILS FIELDBOOK: PAGE: DRAWING 14120160TH AVENUE SE C 1 1 LU RENTON, WASHINGTON 98059 SHEET' OP:28 U DRS PROJECT NO. 16041