HomeMy WebLinkAboutT-405406qqt
L J
C)
1
N
I
O
rr
Cl)
0
z
J
2
0
2
w
1-
1—
Cl)
rr
a
0
W
C)
i 11WII:1T i ID':5D30BA1A-204D-48E8-BB23-8A2834BB565E
a L7 s .
AL.: !A UM L 4 AIRF: AND POLE
RELATED. PARTS SHALL. BE FACTORY
PRIMED AND POWDER COATED.
FINISH COLM. RAT. 9005TX "JET BLACK"
PRESTIGE SERIES (CY17T4) LED
POST -TOP LUMINAIRE (WATTAGE
PER PLANS, 4;000K CCT, 120-277V
UNIVERSAL DRIVER; WITH VS3AR
RIDDED ACRYLIC LENS) BY GYL'LCINE.
(DR APPROVED NUAL), DRIVER
SHALL BE. INTEGRAL T€1 THE
FIXTURE.
TERMINAL BLOCK LOCATED N THE
FIXTURE
STRFFT LIGHT STANDARD ITEf'X
NUMBERING PER. STD PLAN 121.
2" CONDUIT ON
STATED OTHER+
PLANS.
ANCHOR. BOLT
2' CONDUIT UNLESS
STATED OT.NERMSE ON
PLANS
d" FOINIIAT14N4 CAP` `
3/4" UHAMFER (TYP'.,)
(4) OVAL SLL,?TS
/11,
BASE PLATE DETAIL
- #5 BARS,
VENILY.SPACED
ato Comma
4. FOUNDATION
OTT UR_ :{DIA PER.
ASE PLATE DETAIL, -
HIS SriEE:.T)`
,4 HOOPS 8' T2
FOUNDATION SECTION
=JIND POLE TO
F— FOUNDATION
EXTEND THE CONDUIT It 1 11 1 LM
5^ MIN: BEYOND
FOUNDATION OR THE'
CONTROLLED DENSITY
BACkEILL
14'-0" FLUTED 'SHAPE, 5" DIAMETER
r~
#4 HOOPS 0 12"-
STRAIGHT -ALUMINUM POLE
w
a
(PD15-t4-8D46-RAL9095TX-TN43)
8 - #5 BARS, -m
BY CYCLONE (OR APPROVED ECUAL)
EVENLYSPACEDa o.
-
2 1/2° CLR' J
n
INSTALL GROUT.
U'
PROVIDE 1/2" DIA. DRAIN
3" MIN. BOLT a a
..
TUBE THROUGH GROUT. —+�,
PROJECTION W
S14" CHAMFER
24°
6"
HIGH FOUNDATION CAP
` FOUNDATION QFTAII_
- r 719" DIA
,� t �
', • # � r `�".' t '?' I/�. STEEL ?(fili=
2"x5" HANOHDLE
+ . f
.. .... .NOLi CIRCLE' ; #
PER BASE PL&'IE
DECORATIVE ALUMINUM C.Atr4IT"11
DETAIL, Tq.S S HEE'1
BASE COVER 8D46 BY CYCLONE
ANCHOR BOLT TEMPLATE DETAIL
(OR APPROVED EOUALI'.. VILE
BASE aETAIL
10 F %ONDATION
POLE BASE PERDETAIL
THIS
ANCHOR BOLT, 4 "IDTAL.
SHEET".
3/4";DIA (TYP),
-
16' DIAMETER-
BASE COVER
3/4":REX NUTS, STEEL (6
REO'D PER ANCHOR BOLT),
FLAT WASHERS (6 REVD PER
ANCHOR BOLT,)
�'r 'r'•"
ANCHOR BOLT ASSEMBLY DETAIL.
FOUNTHIS DAVONPER DETAILS,
FOUNDATION DETAILS
POLE ELEVATION
NOTE SONATUBE SHALL NOT BE ALLOWED
FOR FOUNDATION CONSTRUC-90N
NEIGHBORHOOD STREET
STD. PLAN - 116-1
+ PUBLIC WORKS
PEDESTRIAN LUMINAIRE
ROVED:
DEPARTMENT
FIXTURE AND POLE DETAILS
GAZ 3/13/'2019 I
DATE
Dacu9ign Enyelope ID: 5D308AIA-204ID-48E&BB23-8A2 .BB565E
POLE
PAD
JUNCTION BOX
LMINAIRE CONCRETE
SIDE VIEW
LUMINAIRE CONCRETE PA[ DETAIL
GENERAL NOTE
1, LUWNARE CONCRETE PAD SHALL BE USED IN AREAS
OUTSIDE OF SIDEWALK:
2. CONCRETE CLASS FOR LVMINA:RE CONGRETE PAD 3TIAIL.
BE PER STD PLAN 135
3. TRP OF 141MIN.AIRE FOUNDATION ELEVATION SHALL BE
LOCATED AT BOTTOM OF LUMINAIRE QQNC(tETE P•AD
ELEVATION: OR BOTTOM OF SIDEWALK ELEVATION
4. LUMINAIRE POLE AND JUNCTION, BOX TYPE PER PLAN
5: LUMINAIRECONi RETE PAD ACCONMIODATES TYPE T AND
TYPE 2 JUNCTION BOXES ONLY
Pul ILIC 'WORKS
DEPARTMENT
fl
Call 2 Working Days Before You Dig
all
tilities Underground Location Cente
(ID,MT,ND,OR,WA)
I-UMINAIRE POLE 11 NOTION BOX
CONCRETE SIDEWALK
PLAN AEW PER STD PLAN T02
UMIN:ATRE POLE
CONCRETE SIDEWALK:
PER STD PLAN 102
_ I
JUNCTION BOX
LUMINAIRE QONCRETE'.
FOUNRATION;
SIDE VIEW
LUMINAIRE WITH SIDEWALK.RETAIL
16}
asaa. .
CONCRETE PAD -0
JUI'ICTION eo* PLAN VIEW
4.
'CONCRETE Pr10
JUNCTION 'BOX SIDE w9EW
INDIVIDUAL JUNCTION BOX PAD DETAIL
LUMINAIRE CONCRETE
PADISIDEWALK AND STD. PLAN' --- 120
JUNCTION 80.7E CONCRETEPAD r�cnn;,,,,„f
oF WAS
IVD�?THWE�T
TRA FF/C EX PER TS
11410 NE 124th St., #590, Kirkland, WA 98034 FS /oninLR��'G\
Phone:425.522.4118 Fax:425.522.4311
5—
-- INSTALL DECAL NLWERS VERTICALLY,
INSTALL IN DRY WEATHER, 50° F OR
ABOVE
1 NUMBERING
2 EXAMPLES
3
C —
- LED TYPE
5
6
7
\PITRAMH
WATTAGE
F—
L
LaJ
.l
LED i
Li
CD
PLAN VIEW
II
FOR STD PLAN 117.1
(77
FOR STD PLAN 116.1,117.2,117A
4 TO 2"
€38"
I
00
N
N
DECAL:
REFLECTOREMD GOTHIC GOLD
OR WHITE
LEGEND ON BLACK BACKGROUND
E,
U!�
#r, PUBLIC WORKS
STREET LIGHT STANDARC)
DECAL NUMBERING SYSTEM
STD. PLAN- 121
PROV
DEPARTMENT
m
FUSE KITS QUICK
REFER TO WSDOT LOCKING. DISCONNECT 10 AMP IN LINE
LID STANDARD DUTY FUSE KITS S:E.C. OR EQUAL -
JUNCTION BOIL TYPES I &
2 STANDARD' PLAN J-40.10
GROUND LUG
SPLICE KITS CLEAR EPDXY SPLICE
KITS ON ALL THRU WIRE RUNS—\
CONCRETE PAD OR
SIDEWALK PER STD PLAN 120
2e(MIN) .'COVER' #8 BARE COPPER
GROUND WIRE
GROUND ll II
CLAMP 1 II
II
1 -#8 EQUIPMENT GROUND»
PVC CONDUIT, II Il
WIREW/GREEN INSULATION
FROM SERVICE CABINET
2 - LIGHTING SYSTEM
5/8"x8' COPPER CLAD
WIRES TO CONTACTOR
GROUND ROD
(SIZED AS REQ'D,)
LUMINAIRE
GREEN INSULATED WIRE'
FIXTURE GROUND LUG
CONCRETE FOUNDATION
NOTES:
1, THIS DETAIL DEPICTS THE BASIC LUMINAIRE ELECTRICAL WIRING ITEM. ,ADDITIONAL ELECTRICAL EQUIPMENT MAY
VARY.
2. MINIMUM GROUND WIRE SIZE SHALL BE #8; AS SHOWN ABOVE IF CURRENT CARRYING CONDUCTORS ARE LARGER
THAN #8, THE MINIMUM GROUND WIRE SIZE SHALL MATCH THE LARGEST "WIRE SIZE OF THE CURRENT CARRYING
CONDUCTORS:
1 EQUIPMENT GROUND WIRE & BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE POLE
HANDHOLE ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND
MAINTENANCE.
4- IF THE: FIIETU E MANUFACTURER HAS MADE PROVISIONS FOR THE ATTACHMENT OF .A GROUND WIDE, A GREEN
INSULATED WIRE OF THE SAME SIZE. SHALL RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE
HANDHOLE. IF THE FIXTORE MANUFACTURER HAS A GROUND LUG A #8 GREEN INSULATED WIRE SHALL BE RUN
FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUI.
PUBLC WOO
' DEPARTMENT
LUMINAIRE' ELECTRICAL
WIRING -SYSTEM
STD. PLAN - 119
OVER:
DATE
SURVEYED:
DESIGNED:VJG
2 COR REDLINES VJG 5/8/19 LDH DRAWN: VJG
1 COR REDLINES VJG 3/15/19 LDH CHECKEDLDH
N0. REVISION BY DATE APPR APPROVED:
LDH
DowSign Envelope ID
_ I
SHIM TO PLUMB
/SHIM LO PLCIM6
SEE' NOTE 3 i J ,e-».SE€ NOTE O
TRANSPORTATION NOTESroom W01wS STD PLAN 135
DEPARTMENT A � F�I)VED; 3,45/2019' 1 4
A� DATE:.
NSETES
1. y111 FQNDAIQy hnQ T<, P9(_.,TGiMNfALL UEA4.Ef �0µg7R0
vNI`LV54WIbt4 sWdtaX jW11WMPL%WERE
kA9i..OUTT3RTOAM4, 9' ,L.MN
1i€ .F7),II F{ElA (3Y A
C€SFPETE CONTRACTOR AND 54ALL MEET THE. RE6SNREMEtiTS OF
SEE'i1N 3-i4F 53 +t1 '(FIE I T S'TANOARTY 8P€55&'11605.
9. PAU MOU04.DESI N 16 iPPlI
1 PLACE A. 50CtiN€ SE4 akf*EN Tht, FSONRANO AND tMAtT.
45 ANCH95 QIT5 0o -Tklm SPACING -P. B€ 5UPP£I F :RY' trNT'
MANUPACTUREB AND WWIYIED Tb THE. ENE`r ift , FOO APPEtOV ,U,
ft. GCiNRUTT ?S1FES, QUANTt7g95 FOR. $:E CON.TROLLER` pN6 CQNTAfT.QR
CADINET5 SHALL. BE INSTALLER PER. THE Ce,'gMACT PLANS, PUTS ONE
2` SPAIM CAPAED EL T?Aa7 114F P,OUNIJATIM.
5'. CO'N' 9T5 CLASS 3xE'k BTO.PLAN 1:Y5_
7. 2' CONDUIT MALL BE RILACED FROM 7143 GCMBINED SB"ONTAGTOR
TO TH;f 6®NYROL-EA £PBt1E
6. SACH OA8 NE:e SHALL. HN& -A N' OtAU51ER PLASTIZ IWAIN PIPE.
4 LOCATE C®WnUIT'S CENTRALL-T" NRWN THE CABINETS.
I %- ViEN ALL THRcE CAPINE7S, ARC TO BE..INSTALUX) NO SPATE,
ALLOWS„ A.COV6W0 FOUNDAT04 SHALL 5E UNED-
11, MUER 941ASSHALL NOT 'BE"115Efii'
IZ GRMXDONC SYik— BE KR WMQT.STANDYARD PLAN J-'DD,DS, SHEET 3.
I 1 H`wPS AEON Tt ':IsuMIS
EDUA2L 15PACE5j'--. ,SEE. NOTE 3-
�
WN
FRbNT.yi�W -_
,3 R0w4RCwG 61iW'. {EODAL SPACESD .
-- S/'B'" DIAMETER PLASTIC DRAIN (ONE PER CABINET:).
SEE M(ltE
SEE NOTE 7
3VV `DIAMETER PCP.SUC CN2.51Nj
S'EE NOTE 5
_ 4
r?�•
HIXi179N"fAL
v
•I' COL€B1NFD'. F0UNT3A710Ni
REINF BAR DIAGRAIM
i OEOES
lf #4 I' l �Qb P.E"zin" >}A
SCALE:
1 "= 40'
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATU M
C TY OF
RENTON
Planning/Building/Public Works Dept.
T-405406
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
DEVELOPMENT ENGINEERING 00416
bbannwarth 07/01 /2019
ul
TRANSPORTATION OPERATION
cbarnes 07/09/2019
CEDARS AT THE HIGHLANDS DATE:1-16-19
14120 160TH AVENUE SE PAGE: OOK:—
AGE:
RENTON, WASHINGTON DRAWING NO:
I L2
ILLUMINATION PLAN
SHEEP: 2 OF:
1—
a
J
I
Er
0
Cl)
0
z_
0
z
a
J
z
W
w
ar
0