HomeMy WebLinkAboutS-051006FILL DEPRESSION WITH GROUT SEALER TO COVER ANCHOR BOLT AND PREVENT DEBRIS FROM FILLING HOLE NOTE: TANK /SLAB SEAL CONNECTION ALTERNATIVES MUST BE APPROVED BOLT AND WASHER TO BEAR B THE ENGINEER. AGAINST CONCRETE SLAB TOP OF PRECAST CONCRETE TOP SLAB FOR 12' DIA. LIFT STATION DEPRESSION TO CONCEAL TOP OF # ANCHOR BOLT, CONTRACTOR TO SIZE, BOLT SHALL NOT EXTEND ABOVE � o CONCRETE SLAB., D ' : v OR 1" DIA. SLEEVE FOR REMOVABLE 1, b ANCHOR BOLTS, CAST WITH CONCRETE SLAB THREADED FOR OR CIRCUMFERENCE OF STRUCTURE MANHOLE GASKET' (TYP. EACH JOINT) b,. ,- GROUT AS NECESSARY TO FILL GAPS (TYP.) RUBBER GASKET TO SEAL BETWEEN CONCRETE ` r AND FRP TANK ALONG CIRCUMFERENCE. DRILL HOLE IN CONCRETE WALL FOR INSTALLING HILTI HVA ADHESIVE ANCHOR SYSTEM Y4" DIA. ADHESIVE ANCHOR INSERT � b ',, ..�., '' ° �' y`= °` APPROX. 1' -6" ® 12" O.C., CIRCUMFERENCE OF STRUCTURE, EQUAL TO HILTI HVA ADHESIVE ANCHOR SYSTEM:^ INTERIOR WALL OF 9' DIA. FRP TANK, EXTERIOR WALL OF 12' I.D. TOP OF FRP TANK WALL TO BEAR AGAINST CONCRETE LIFT STATION RUBBERIZED GASKET AND SEAL CIRCUMFERENCE REMOVABLE TOP SLAB CONNECTION CO3 TANK /SLAB SEAL CO3 SCALE: 1" = 6" SCALE: 1" = 6" W' STEEL PLATE CONNECTION, 16 PLATES EQUALLY SPACED AROUND PERIMETER, COAT PLATE WITH COAL TAR EPDXY BEFORE INSTALLATION JOINT BETWEEN MANHOLE SECTIONS S -6" 2" B" B" grog 1' -2" In -W' DIA. EXPANSION BOLT, EQUAL TO HILTI S.S. KWIK BOLT 11, KBI1304SS34 -434 EMBEDMENT DEPTH PER MANUFACTURER'S REQUIREMENTS TO DEVELOP FULL STRENGTH OF BOLT MANHOLE GASKET (TYP. EACH JOINT) 6 „`', �- INTERIOR WALL OF 12' I.D. PRECAST CONCRETE LIFT STATION, WALL REINFORCEMENT NOT SHOWN 2„ �o Yl ±,...; —L2' Ij MANHOLE JOINT CONNECTION C13 CO3 SCALE: 1” = 6" REVISED TO CONFORM TO CONSTRUCTION RECORDS .e�iJis�lLG /®PE �l�s RH2 ENGINEERING P.S. DAffE GRATING OBLIQUE a q F q 16727 �`D�+sTSREOx SIGNED: Sroxnt 10109192 EXPIRES 8/2/96 FRP LADDER CONNECTED TO CONCRETE TOP SLAB AND GRATING FRAME, SEE DETAILS DWG. NO. UO2 1 ,. 1• 1 (2) Y2" DIA. FRP BOLTS AND NUTS, EACH LEG OF ANGLE, EQUAL TO FIBERBOLT 4 "x4 "xY8" FPR ANGLE, EACH SIDE 16x3xY4 BEAM, COPE FLANGES AT ENDS W 6x6xYe BEAM GRATING PLAN SCALE: 1" = 2' -0" 2 "x2" SQUARE x2" THICK FRP MOLDED GRATING, EQUAL TO CHEMGRATE, SECURE TO SUPPORT FRAME WITH S.S. CLIPS AT 12" O.C. EXCEPT WITHIN RFMOVARI F SFCTION 1' 4 "x4 "x3'e" FRP ANGLE MOLDED INTO TANK WALL AROUND INTERIOR CIRCUMFERENCE D GRATING CONNECTIONS coo SCALE: 1" = 4" 9' -0" DIA. FRP TANK AND SLEEVES 2 "x2 "x Y4" FRP ANGLE, FULL LENGTH OF BEAM, SECURE TO TOP FLANGE OF BEAM WITH EPDXY, ;TYP. EACH SIDE OF GRATING) 3' -0" x 4' -0" REMOVABLE FRP GRATING TO FIT BETWEEN AND MATCH LEVEL OF ADJACENT SECURED GRATING FRP GRATING, CUT TO FIT AGAINST TANK WALL CUT FRP BEAM TO FIT AGAINST TANK WALL (TYP.) GRATING NOTES: SEAL ALL CUT FIBERGLASS EDGES ALL FIBERGLASS BEAMS TO BE EXTREN 625 OR EQUAL. CUT GRATING AND BEAMS TO FIT AGAINST TANK WALL (2) 1/2" DIA. FRP BOLTS AND NUTS, EQUAL TO FIBERBOLT, EACH SIDE OF BEAM WEB CENTERED WITHIN BEAM FLANGE 9' -0" DIA. FRP TANK WALL ,S -- - (o SCHEDULE A ONLY ^I A .I_ _I^ -I I— -I. A -I— -I_ ^I^ J— j I I IA 11 I — A 1 A I I -I— 1- -1 -I ® I 1 ® .. _ _ ®_ _sue® ® as