HomeMy WebLinkAboutD-224002-224 to A 4COMPLIANCE W o, exaq.�F FY lei l"A U tea -a- FOR "AS CONSTRUCTED G® ° m PLANS" ONLY — -- Date . °,°,.«�� +�' •,.GGrrsa� Date ssro "M E" 4�ONAL6�a �i1r h Sw - a7 -asvD FILENAME: MILLI GENERAL UTILITY NOTES: RHO. STATE FED. AID PROD. NO. I. ALL PIPE AND FITTINGS FOR WATERLINES SHALL BE CEMENT MORTAR -LINED DUCTILE HIGHWAY DiVISiON APPROVED ® Washington State Department of Transportation SR �5 SOUTH RENTON TO SUNSET BLVD. HOV gN_17 IRON. ALL PIPE SHALL BE THICKNESS CLASS 52, UNLESS OTHERWISE SHOWN. PIPE JOINTS MAY BE PUSH -ON OR MECHANICAL JOINT, UNLESS OTHERWISE SHOWN. ALL WASH I -IR- 405 - 3(783).. FITTING JOINTS SHALL BE MECHANICAL JOINTS, UNLESS OTHERWISE SHOWN. PE LEGEND SLEEVES SHALL BE INSTALLED BETWEEN MECHANICAL JOINT FITTINGS WHERE REQUIRED. 2. ALL VALVES 12 INCHES IN DIAMETER OR LARGER SHALL BE INSTALLED IN A VAULT. EXISTING NEW GATE VALVES SHALL BE SUITABLE FOR 250 PSI OPERATING PRESSURE AND SHALL s1EE� of 1C,74 SHEETS PROJ. ENGR. J.E. JOHNSON BE METROSEAL 250, AS MANUFACTURED BY U.S. PIPE, OR APPROVED EQUAL. U!'�S oaratTw+la RoseWater Engineering, Inc. MILL AVENUE UTILITY LEGEND AND GENERAL NOTES DIST. ADM. R.Q. ANDERSON - - - -- - - --- -- 6" W - - - - --- - - -- 6" W WATER LINE 3. FIRE HYDRANTS SHALL BE IN ACCORDANCE WITH DETA I L DATE REVISION BY WD-7 - - - - -- -- - - - - -- 12" 5 - 12" S SAN SEWER LINE 4. ALL WATER MAINS SIX INCHES IN DIAMETER AND LARGER SHALL BE CLEANED WITH PIPE CLEANING "PIGS" PRIOR TO DISINFECTION. THE "POLY PIGS" SHALL BE 2 LB /CU FT - -- - -- +" G - 4° G GAS LINE DENSITY FOAM WITH 90A DUROMETER URETHANE RUBBER COATING ON THE REAR OF "PIG" ONLY, "PIGS" SHALL BE CYLINDER SHAPED WITH BULLET NOSE OR SQUARE END. - -- - -- Bf -- - - -- - -- BT BURIED TELEPHONE 5. UNLESS OTHERWISE SHOWN, MANHOLES SHALL BE AS FOLLOWS: - -- OP OP OVERHEAD POWER MANHOLES OVER 7' -0" DEEP - DETAIL 8 _ -- -- IS'" S1 18" ST STORM SEWER Wi MANHOLES 4' -0" TO 7'-0" DEEP - DETAIL 2 r� 0 MANHOLE 11 CATCH BASIN 6. ALL JOINT RESTRAINT SYSTEMS (SHACKLE RODS, NUTS, BOLTS, ETC.) SHALL BE AS MANUFACTURED BY THE STAR MANUFACTURING COMPANY OF COLUMBUS, OHIO OR EQUAL O SANITARY CLEANOUT APPROVED IN WRITING. SHACKLE ALL WATERLINE BENDS. FOR RUNS OF JOINT RESTRAINTS IN EXCESS OF 20' WITHOUT FITTINGS, RESTRAINED JOINT PIPE MAY BE FIRE HYDRANT USED. JOINTS MUST BE CAPABLE OF BEING DEFLECTED AFTER ASSEMBLY. ® WATER METER 7, ASPHALT AND CONCRETE STREET PAVING SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES. OIL MAT STREETS MAY BE SPADE CUT. ALL SURFACE CONCRETE PAVEMENT, r WATER VALVE BOX SIDEWALKS, CURB, GUTTERS, AND DRIVEWAY APPROACHES SHALL BE SAWCUT TO A MINIMUM DEPTH OF TWO INCHES OR REMOVED TO AN EXISTING EXPANSION JOINT. r >1 DG GATE VALVE UNDER 12" g, A TEMPORARY COLD MIX ASPHALT PATCH SHALL BE PLACED ON THE DAY OF INITIAL EXCAVATION WITH A PERMANENT, SEALED PATCH TO BE PLACED, g. • GATE VALVE IN CHAMBER 12" WITHIN TEN DAYS, WEATHER PERMITTING. TELEVISION J BOX 9. BLOCKING FOR CONVEX VERTICAL BENDS IN WATERLINES SHALL BE IN ACCORDANCE WITH 6-L WSDOT STD. PLAN B -22. TURNBUCKLES SHALL BE USED. -} TELEPHONE VAULT 10. CAUTION - EXTREME HAZARD - OVERHEAD ELECTRICAL SERVICE LINES ARE GENERALLY NOT SHOWN ON THE DRAWINGS. ELECTRICAL LINES SHOWN ON THE DRAWINGS ARE ter° ELECTRICAL J BOX LOCATED BY POINT -TO- POINT, POWER POLE -TO -POWER POLE CONNECTION. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXTENT OF ANY HAZARD CREATED BY OVERHEAD ELECTRICAL POWER IN ALL AREAS AND SHALL FOLLOW PROCEDURES DURING . ... . ... DITCH CONSTRUCTION AS REQUIRED BY LAW AND REGULATION. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL MEET WITH UTILITY OWNERS AND DETERMINE THE EXTENT OF HAZARD ASPHALT CONCRETE GUTTER AND REMEDIAL MEASURES AND SHALL TAKE WHATEVER PRECAUTIONS MAY BE REQUIRED. ' 11. IDENTIFICATION, LOCATION, MARKING AND RESPONSIBILITY FOR UNDERGROUND UD -T - -i° UNDER DRAIN FACILITIES OR UTILITIES IS GOVERNED BY THE PROVISIONS OF CHAPTER 19.122, REVISED CODE OF WASHINGTON, 12. SIDEWALK PATCHING SHALL MATCH EXISTING THICKNESS AND FINISH. -224 to A 4COMPLIANCE W o, exaq.�F FY lei l"A U tea -a- FOR "AS CONSTRUCTED G® ° m PLANS" ONLY — -- Date . °,°,.«�� +�' •,.GGrrsa� Date ssro "M E" 4�ONAL6�a �i1r h Sw - a7 -asvD FILENAME: MILLI RHO. STATE FED. AID PROD. NO. SHEET TML HIGHWAY DiVISiON APPROVED ® Washington State Department of Transportation SR �5 SOUTH RENTON TO SUNSET BLVD. HOV gN_17 PLOT DATE: 8/9/91 10 WASH I -IR- 405 - 3(783).. DRAWN E.M.L. CHECKED DNP JCB NUMBER 91WO97 s1EE� of 1C,74 SHEETS PROJ. ENGR. J.E. JOHNSON U!'�S oaratTw+la RoseWater Engineering, Inc. MILL AVENUE UTILITY LEGEND AND GENERAL NOTES DIST. ADM. R.Q. ANDERSON 16.91 REVISED SHEET #'S PER WSDOT CONTRACT NU"BER osa DATE REVISION BY PP'D ROLL 1 149 254