Loading...
HomeMy WebLinkAboutD-27220B� � a ✓� Da N 1 a � °sow= N F — CB #17 CL (� EX. S MH RIM =31.73 IE 8" =27.6 - CB#186 EX. C.O. STA. 52+ 1.05.. o T IE 8" =27.5 RIM EL = 30.65± -a IE E/ 27.0 IF (N) = 28.25± CB #178 \ n c \ CB n IE CB =30.28 O6 W IE 8- 6V=28.2 N Q V / Trailer \ _ J IE 6_ NN 27.6 LLJ 0 j n �1 \ =7 -s\ U.) oc `J N � Grass W i1 r / f > !B W W W / W w -- _ w \ G 12" H.P. G�S G G _ —_— G o G 12" H.P. GAS Zj'\ v2 7 -7/4' IP. AS INT. N — G Gib v - -- ^z s _ o, _ - = ucr LID N ° ® UG — -- -- GGT B G T — — ucT Z Begin cant. walk 3 < 2 c. °lamer u — — ` a z c AS-BUILT DRAWING a \ E a _ -a -. _ 1� I ! I a I AS RECORDED BY TRACTOR j v I - _I Brush \ -\ c CON SURVEY VERIFICATION CB #1 SA c6 #nA o 2 FROM THE FLUER COMPANY `c I I 3 1 -1Y u� n ` n� CB#16 - r. I CB RIM -29.63 NOTE: - — \ IF 27.7 CONNECT NEW TYPE MANHOLE TO EXISTING -_ - STORM PIPE Brush \ -.- {.. RECOMMENDED FOR APPROVAL 3 I I NOTE: Brush STORM WATER UTILITY DATE 3` a a I 11 C LOCATE fiEW COPPER WATER SERVICE CONNECTIONS I - I a OVER NEW STORM DRAIN PIPE STORM WATER MAINTENANCE DATE E o (TYPICAL) I I I I- i - Horiz_ 1" = 20' Vert. 1 " = 5' i I f o a 53 +50 53 00 52 00 — — — 51+00 — — — — 50 +00 a M CB #18, TYPE 2. 48" CB #17. TYPE 2. 48" : : : . . . . . .. .. .... ................ ....... ...... .................... STA. 53 +46, RT. 1' : : STA. 51 +88,.RT. 1' - - CB #16, TYPE 2, 48" - - - - - - " - SOLID LOCKING LID - - - SOLID LOCKING LID - TA 4 1 - - c 0 Ain^ 31 60 :+ RIM: = 31.60 : ^nor 31-1G RIM = 30.54 : SOLID 5 LOOKING TLID - - �L - a - - 18" S IE = 27.24 - - 18" S IE - 27.44 - - -� - - _ - - - w 12 N IE = 27.`,L4 - - - - " 18" N IE = 27.21 - - - - - - - - - - z _ 35 .. -: - - -- 12`: E -IE 27.24 ............... ----12;; -E -IE _ 2721...... - RIM 3075. -- -- --- --- 35-- - w w - 12 IE = 28.04 _ _ - 12 - IE = 27.00 - 18, NE) JE_ 27.29 - 22.509 - Q _ IJJ:J� _ -- - - - - -GRADE AT CENTER LINE - - ------ - - - - -- - - -_ - -- _ _ - _ 18" (SW) - 30 aw _ _ _ _ - - - -- 30 �w 158 LF, 18" DIP @ 0.08% 134 LF, 18" DIP @ O.11% 2 .............. . . .... ;... .....:..... ..:...... -: -..- --- - ._- ... - -.- : -. - -.. - -:. -. _.. -. -... -. -.. _----. _.. _ 2 5 -. _ -.. -. _.... :.- .- ...-- _.- .......:........., " 16" W (TO BE ABANDONED) I NEW 10 ". W CB# 18A, Tv, . � 1 STA 53 +46 LT. 21' _ - CB# 188, TYPE 1 CB# 17A, TYPE _ STA. 51 +88 LT.. 21' -CB# 1713, TYPE 1 CONNECT NEW TYPE 2 MANHOLE TO EXISTING - - - BI- DIRECTIONAL STA. 53k.46. - RT 20'............ BI-DIRECTIONAL ; ......... - :STA.- 51+88i -RT. 20' ............. 18" STORM PIPE. _ _ ....... Z o VANED GRATE BI- DIRECTIONAL VANED GRATE VANED GRATE BI- DIRECTIONAL VANED GRATE in �,"�'- EC\�= 3k - RIM: EL. = 30.55 ± : - c RIM EL. = 30.96. 12" _(F) IF = 27:66 - - - -.- - -. - - RIM EL. = 30.97 - - - - - - - - 12" (W) IE = 28.47 - 12" (E) IE = 28.05 _ - - _ - - - - RIM EL. = 29.98 - -_- - - -_12" (W) IE = 27 -58 - - - - - - - - 3�j L _ _ I 30 L. o UG' ¢ 0 6" WATER (TO BE ABANDONED) o 2 5 L1GT ... � .:...... 6. :WATER.. :........ TO BE ABANDONED ( ) ..... :... :.........:....... :........ -. :....... :........ 22 LF 72' DIP SD @ 1.09 -- � 2" GAS J � -12" WATER -19 LF 12" CPEP SD @ 1.0% 22 LF 12' DIP SD @ 1.0`7 2' GAS 12" WATER r 1 2' 11 P GAS '1 ° 19 LF 12" CPEP SD @ 1.0% 2 _ 12" HP CASA, [ SCANNED SEP 1 3 2002 L L 176 F R ,v 3-:6