Loading...
HomeMy WebLinkAboutS-202303EXISTING 6' FORCE MAIN - DOWN TO EXISTING LIFT STATION AT COLUMN M11 c 1. 4" FORCE MAIN DOWN - 6 n N CONNECT TO EXISTING, SEE C203 z z z z = z z j z z z z z z z z z z z - z J PIPING IN MECH MEZZANINE SEE q 0 0 0 0 0 0 0 0 0 0 0 O O O O O v O v O O O C201 °o EXISTING FM Y1 FOR PIPING THIS q° CAFETERIA \ T AREA, SEE a C203 e A -20 BUILDING a FOR FLOOR AND WALL SEE PARTIAL PLAN C203 \ PROVIDE CLEANOUTS ON PENETRATIONS ABANDONED POWER ATI T 2" HUB \ i�' ALL BRACH LINES SE FOR PIPING THIS AREA DUCT TO DEMOLISHED \ \ 1 -4 1 BUILDING 4 -01 &' (7 TYp CAP EXIST IN / C202 7 4 -03 ) BUILDING 4 -20 NORTH WALL MECH MEZZANINE �F�1' -CO 1 1 2 1 HPW ABANDONED IL - - IN PLACE (TYP) 1 COLUMN LINE S �� I - -- 1 - -- - - -i �� - - -_ ass- - -1 SS - -- - -9 -- g5T5 =_- IH - 10HPW2 e"SS == - -_ -5i 5-' -1N'STS -I- - - -- -I-I- - - - - - 1 -1- - - - - -I -I - i- - - - - -I -� -srs- - - - - -I - - -1�9T5- -- BUILDING DING , I 2"W 2„W, 2„ W, I I• 2 "W 12 "W DOOR 16 , JJ4 "CW_ I I _1 40 I T70'±-' _ J_J_ _ _ _ _ _ DOOR '.15 - _FM_ ~(t _ - I -� -. 12_x- Ir -I - .STS- -i I -1� I -- - TI 1- _17srs _ _ $- - 10"HPW - T - - - - _- I- - -I - FIA HPW --'-' 1 — -FM - I = - ,10"HPWT - - ._ - 4 "FM 6'HPW - 1- - - -VAF- - - - -- - - �i_AF ' AF- - - - AF - - - - -- -- 9"AF - -- w SLOPE i i 6"W i SEE NOTE 15 CO. (TYP) - - - - -t - — - - -- - — - _ — - 6.W� - - - - PAVEMENT CUT LINE I� FLOW STS ABANDONED 4 "FM LIFT STATION, IN PLACE (TYP) CLEANOUT (TYP), a O 1 POWER CONDUIT I SEE SHT C202 FLUSH WITH EXIST GRADE, 1- Wcw- - - - - SEE 1&2 IN TRENCH ANDe SEE SEE C (6 TYP) A SEE C 02 I E e D C 5 -B '2.1 e I C203 C203 C203 I 020 1 &2 C203 C203 u C20 TYP CONNECTION TO STRUCTURAL '..�� SUPPORTING MEMBER TO BE SAME FOR VERTICAL, I DIAGONAL AND LONGITUDINAL SITE PLAN �� 5 /e"INSERT (USE EXIST IN SCALE: NONE N 2 1/2 x2 1/2 x16 CA INSTALLED) BEAMS WHERE - LONGITUDINAL DIAGONAL ® 80'. OC MAX .ASPHALT CONCRETE ` PAVEFULL WIDTH OF -i 5 /6'ROD AREA WHERE SLAB (3 "MIN) REPLACEMENT HAS BEEN REMOVED PATCH TO BE 1" II THICKER THAN FINAL JOINT MUST BE DIAGONAL ANGLE - -' PREVIOUSLY EXISTED. -- - SAW -.CUT - 2" x2 x16 G - -I ADD PIPE SLEEVE THAT HAS AN ID 1/4" LARGER THAN EXISTING 3/6' BOLT TO ANGLE OD OF BOLT ASPHALT CONCRETE 6" ° TMIN.I CRUSHED SURFACING TOP, COURSE "ELCErI" HANGER ROD CUP 4" FORCE MAIN - + SURFACE - COMPACT SUBGRADE SUBGRADE - EXISTNG PAVEMENT.. ASPHALT CONCRETE PATCH TYP FORCE AIN RAVEL BASE, a e° ° e RESTORATION' SEE OVER PREPARED GRADE 2 SEISMIC' PIPE BRACING �1 8" LIFTS, 959. MAX D.D. ° B g DETAILS 3 &4 SCALE: NONE C201 Q e 8 e z THIS SHEET SCALE: '. NONE C201 COMPACTION b _ .FINAL JOINT: TO SEE NOTE 17 AND 13 CEMENT CONIC (6'MIN) i9'-D 6^ BE SAW -CUT REPLACEMENT PATCH TO 4 "FM (WHERE I #p5 x31 NG a BE 1 "THICKER THAN 9' -6" TYP APPLICABLE) VERTICAL TRENCH '6OWEL BARS _ _ PREVIOUSLY EXISTED. CONTROL PANEL 6" SUPPORT SYSTEM ®i6'OC (TYP) - LOCATION (SEE 0 O BY CONTRACTOR OMIT DOWELS +- ELEC DWGS) - BEDDING AS REQUIRED FOR EXISTING 8" LIFTS, 95% ASPHALT PAVEMENT EXISTING ASPHALT CONCRETE PAD / 5'4 \ / 5'0 \\ COMPACTION Z' OR 6" DRILL AND GROUT INTO OR. CEMENT ' 4• -12 I b GRAVITY WASTE EXISTING SLAB 6" CONC PAVEMENT SEE NOTES 6 O VALVE PUMP 1 AND. 10 (° BOX / r- SUMP m iv S E 6' MIN CRUSHED �. r a is SEE SPEC NOTE: BOLLARD D SURFACING TOPCOURSE UNDISTURBED - CONIC SHALL MEET THE. - (g Typ) � � �___________ .' NATIVE MATERIAL ' OD +1.0'MAX REQUIREMENTS OF SECTION 5 -OS - 3" O OF WSDOT -APWA FOR 3 -DAY MIX. COMPACT SUBGRADE SEE NOTE 14 WITH ONE PIPE 12" EXPANSION JOINT - YVENT UP, 3' ABOVE TYPICAL PIPE CEMENT CONCRETE PATCH TYP GRADE ro GOOSENECK O TRENCH SECTION OVER PREPARED GRADES LIFT STATION PLAN 5 SCALE: NONE C201 SCALE: NONE C201 SCALE: NONE 0201 GENERAL NOTES LOCATIONS OF EXISTING PIPING RUNS AND FIXTURES ARE TAKEN FROM AS -BUILT DRAWINGS AND SITE SURVEYS. LOCATIONS ARE TO BE CONSIDERED APPROXIMATE. EXERCISE EXTREME CAUTION DURING EXCAVATION IN ORDER TO AVOID DAMAGE TO EXISTING UTILITIES. SEE SITE SURVEYS FOR ADDITIONAL INFORMATION ON SURFACE FEATURES. CONSTRUCTION NOTES 1. BOLLARDS AROUND SUMP AND VALVE BOX. 5 "0 STEEL PIPE 5'-6" LONG WITH 2000 PSI CONCRETE CORE. HEIGHT ABOVE SURROUNDING PAVEMENT 4' -C". SET IN 12"0, 18" DEEP 2000 PSI CONCRETE BASE. PAINT POSTS SAFETY YELLOW FSC -23655 - SEE SPEC SECTION 09900. 2. PROVIDE'NECESSARY STEEL PLATES TO COVER TRENCHES TO MAINTAIN TRAFFIC DURING CONSTRUCTION. 3. SHORING AND DEWATERING MAY BE REQUIRED FOR TRENCHING AND LIFT STATION EXCAVATION. 4. SLOPE ALL GRAVITY PIPING TOWARD PUMP SUMP AT 1 /8" /FT MINIMUM. 5. CONTRACTOR TO PATCH TRENCH EXCAVATION AREAS PER DETAILS 1 THRU 4 THIS SHEET. 6. CONCRETE PAD ONLY SHALL BE INDENTIFIED BY A FOUR INCH (4 ") WIDE BORDER PAINTED YELLOW SAFETY (FSC - 23655). AND, IN ADDITION, DIAGONALLY STRIPED AT FORTY FIVE DEGREES WITH LINE OF WIDTH AND SPACING APPRORIATE TO THE SIZE OF THE AREA. SEE SPEC SECTION 09900 2.02A. 7. PROVIDE 12 GUARD POSTS A,=ND PIV TO BE FIELD LOCATED BY ENGINEER. 8. UNLESS OTHERWISE NOTED, USE ASPHALT CONCRETE PATCHING FOR ALL SURFACES DISTURBED BY THE :CONSTRUCTION WORK. 9. PROVIDE COMPACTED BACKFILL MATERIAL TO REPLACE MATERIAL REMOVED FOP. DEMOLITION PER SPEC SECTION 2223 3.01 B4 OR CLASS B. 10. REINFORCE LIFT STATION SLAB WITH #4 BARS 0 12" EACH DIRECTION. 11. PROVIDE THRUST BLOCKS ON GRAVITY MAIN SIMILAR TO THAT SHOWN ON C204. 12.IF ASPHALT OVERLAY IS 'PRESENT, PATCH WITH A LAYER OF ASPHALT SAME DEPTH. 13. ALL CONSTRUCTION LATERAL JOINTS AT 15' MAX SPACING TO ALIGN WITH EXISTING SLAB JOINTS. 14. PROVIDE GEOTEXTILE FOR WIDTH OF TRENCH AND ABBREVIATIONS /LEGEND A COMPRESSED AIR AF AUXILIARY FIRE MAIN AFF ABOVE FINISHED FLOOR APPROX APPROXIMATELY BLDG BUILDING CO CLEANOUT CW COLD WATER CIA DIAMETER EST ESTIMATED EXIST EXISTING' FM FORCED WASTE MAIN GA GAUGE GM GRAVITY WASTE MAIN HWL HIGH WATER LEVEL HPW HIGH PRESSURE WATER MAIN CC ON CENTER OD OUTSIDE DIAMETER REQ'D REQUIRED SHT SHEET STS STORM SEWER TY P TYPICAL W WASTE - - - - -- EXISTING PIPING, BURIED EXISTING PIPING, ABOVE GRADE — — — NEW PIPING, BURIED NEW PIPING, ABOVE GRADE BLDG 4-21 COL LINE S %nu�Rar�e�i 71 Rs- 1Buiti" Au. ikbl,-- I AREA OF CONSTRUCTION KEY PUN S -2 2 D -- CITY OF RENTON DEPARTAS);NT OF PUBLIC WORKS KCMseattle, Kramer, Ch1n &Mayo, Inc. RECOMMENDED M1icG . 1917 First Avenue SITE PLAN, SECTION, AND DETAILS RECOMMENDED FOR APPROVAL "SEWAGE LIFT STATION INSTALLATIOIS FoR APPROVAL � J / Washington 98101 g1�.tiplJl(�FP�i(Sral RENTON PWO RENEW COMMENTS SDN 10/18/91 DESIDNED: SDN DATE: 10/23/91 mE NANE:RENMIIV BV ��c..<[ I L /9/ Wqs fEWATER VjIGIry Er+4 /HEK�R _ -- Pp a�ii '� QQ PER RENTON PWD REVIEW COMMENTS SDN 11/8/91 DMWN: DV PL RN REVIEW f .s �� cHECxsD: ACB scu.E: NONE DGn000x: \.A.xD -/C -7nli ' -f ND. XENSIDN BY APPR. DATE MPROYFD: ______ ________ SHEEP: 0201