HomeMy WebLinkAboutS-20291AIX I I I I I AI I I I I I I I% I Y I Y I A I I 1 i I .$ F 4 s T
ABBREVIATIONS
GENERAL LEGEND
GENERAL NOTES:
ABB
ABBREVIATIONS
EA
EACH
L
LENGTH
RPM
RELVOLUTIONS PER MINUTE OR
-" ' - EXISTING STRUCTURE - -'- - = ASPHALT LIMITS
1. COORDINATE SYSTEM FOR THE PROJECT IS AN ASSUMED SYSTEM BASED ON THE
ACI
AMERICAN CONCRETE INSTITUTE
EF
EACH FACE
LAT
LATERAL
REINFORCED PLASTIC MORTAR
-- -'-- - -' -'- FENCE PROPOSED SEWER LINE
COORDINATES SHOWN IN THE COORDINATE SUMMARY.
AC
ACRES / ASBESTOS CEMENT
E
EAST
LC
LENGTH OF CURVE
RR
RAILROAD
SURVEY BASELINE
-'; •'• CONCRETE
2• VERTICAL CONTROL DATUM IS CITY OF RENTOf* ELEVATIONS OF CONTROL POINTS ARE
SHOWN ON SHEET G -3.
ACP
ASBESTOS CEMENT PIPE
ECC
ECCENTRIC
LF
LINEAL FOOT [FEET)
RT
RIGHT
-- RIGHT -OF -WAY LINE
RISC
AMERICAN INSTITUTE OF
ESMT
EASEMENT
LP
LIGHT POLE
R/W
RIGHT OF MAY
_
EXISTING MANHOLE TREES
3. UTILITY LOCATIONS SHOWN ARE APPROXIMATE AND BASED ON INFORMATION PROVDED BY THE
THE `ON€
ALUM
STEEL CONSTRUCTION
ALUMINUM
ED
EDGE OF OIL
LN
LONG
___
_IR.SDR --- STING UTILITY PROPERTY LINE
INDIVIDUAL AGENCIES, ACTUAL LOCATION MAY VARY. THE CONTRACTOR SHALL CALL
N
CALL' CENTER AT I- 800-424 -5555 FOR UTILITY MARKING 48 HOURS N ADVANCE OF ANY
ANSI
AMERICAN NATIONAL
ECR
EN) CURB RETURN
LOO
LARGE ORGANIC DEBRIS
S
SAN
SOUTH, SCUM, SINK,
SANITARY
ROAD RECONSTRUCTION
EXCAVATION.
STANDARDS INSTITUTE
ELEVATION (ELEV.)
lS
LUMP SUM
SCI)
SCREWED
(PROPOSED
4. UTILITY CROSSING LOCATIONS AND ELEVATIONS SHALL BE VERIFIED BY THE CONTRACTOR
4.
APPROX APPROXIMATE
EO
EQUAL
LEFT
SCH
SCHEDULE
RAISE �
N ADVANCE OF CONSTRUCTION.
AR
ASA
AIR RELEASE VALVE
AMERICAN STANDARDS
EVC
OR EOUATION
END VERTICAL CURVE
LT
LWL
LOW WATER LEVEL
SD
STORM GRAN
OSSEp
5. STATIONING SHOWN IS ALONG THE SURVEY BASELINE AS DEFINED BY THE CONTROL POINTS.
ASSOCIATION (IOW ANSI)
EW
EACH WAY
MAX
MAXIMUM
SEC
SECTION
CDC;I � ROCKERY (PROPOSED)
6. CITY OF RENTON STD. DETAILS ARE LOCATED WITHIN THE BOUND CONTRACT SPECIFICATIONS.
ASME
AMERICAN SOCIETY OF
MECHANICAL ENGINEERS
EXIST
EXISTING
IE
MEC�L ETD
SHT
SHEET
- - - - - ROCKERY (EXISTING)
7, THE HOURS OF WORK SHALL BE LIMITED TO 8:00 A.M. TO 5.00 P.M. ON WEEKDAYS
ASTM
AMERICAN SOCIETY FOR
(COLLARED TYPE)
SIM
SIMILAR
- ' - -" ' GABION (EXISTING)
UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS
TESTING AND MATERIAL
EXPJ7
EXT
EXPANSION JOINT
EXTERIOR
W
MECHANICAL JOINT
SL
SLOPE OR SURVEY LINE
- _ - - - --
AT 235 -2620. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY
THE DEPARTMENT OF PUBLIC WORKS 24 HOURS N ADVANCE. THE POLICE DEPARTMENT.
AVAR
AIR VACUUM AND
NIH
MANHOLE
SPECS
SPECIFICATIONS
FIRE DEPARTMENT. AND 911 SHALL BE NOTIFIED BY THE CONTRACTOR 24 HOURS N ADVANCE.
AIR RELEASE VALVE
AVE AVENUE
FN FINISH
MAN Mme(
SO SQUARE
8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND
FD
FLOOR
MISC
MISCELLANEOUS
SANITARY SEWER
GENERAL WORK APPROACH
ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
AWS
AWWA
AMERICAN WELDING ASSOCIATION
AMERICAN WATER WORKS
F TO F
DRAIN
FACE TO FACE
MARK
MARKER
SS
ST
STREET
9, A COPY OF THE APPROVED PLANS AND SPECIFICATIONS MUST BE ON THE JOB SITE WHENEVER
CONSTRUCTION IS IN PROGRESS.
ASSOCIATION
FIN GR FINISHED GRADE
WIL MONUMENT LINE
STA STATION
MAON
MOMAEIiT
THE PROJECT S LINEAR BEGINNING NEAR THE EXISTING PUMP STATION AT N.E. 27TH ST.
10. ASSIGNMENT CONTRACTOR'S RESPONSIBILITIES AND OBLIGATION FOR LOCATING. PROTECTING
BFR
BACK FLOW PREVENTER
FM
FIRE HYDRANT
MASL
MEAN SEA LEVEL LEVEL
STD
STANDARD
AND EXTENDING UPSTATIOi ALONG THE EXISTING NARROW ACCESS ROAD. RECONSTRUCTION
WORK SHALL BEGIN AT THE FIRST AREA NOTED FOR REPAIR AND EXTEND UPSTATION AS
AND REPAIRING G DAMAGE TO EXISTING UNDERGROUND UTILITIES IS SHOWN N SECTION h0707
BK
BACK
FL
FLOWLNE / FLANGE
STL
STEEL
WORK PRO((�iESSES. WORK SHALL FOLLOW THE GENERAL OUTLINE NOTED BELOW.
OF THE SPECIAL PROVISIONS.
BLDG
BUILDING
FLGD
FLANGED
MLTCP
MORTOR LNEG! AND TAPE
COATED PIPE
STN STL
STAINLESS STEEL
ROAD REPAIR AREAS:
IL ALL WORK IS SHOWN SCHEMATICALLY (I.e.: ENOUGH DETAIL ON DRAWINGS TO SHOW NTENTL
ALL ITEMS WILL BE FIELD FIT BY THE CONTRACTOR TO MATCH INTO EXISTING CONYTIONS.
BLD FLG BLIND FLANGE
FLR
FLOOR
N
NORTH
STRUCT STRUCTURAL OR STRUCTURE
BM
BENCH MARK
FIND
FOUND
NO
NUMBER
SY
SQUARE YARD
L INSTALL EROSION/ SEDIMENTATION CONTROLS.
12. THE LARGE ORGANIC DEBRIS (LOD) NOTED HERE -IN IS DEFINED AS LOGS, ROOTWADES. ETC.
WHICH ARE SUITABLE FOR USE IN STREAM STABILIZATION/ FISHERIES ENHANCEMENT WORK.
BO
BLOW -OFF ASSEMBLY
FPM
FEET PER MINUTE
NTS
NOT TO SCALE
2. CLEAR AND GRUB AREAS REOURNG EXCAVATIOf. STOCKPILE ANY MATERIALS DESIGNATED
BOT
BOTTOM
FPS
FEET PER SECOND
OC
ON CENTER
T
TELEPHONE
BY THE ENGINEER TO BE USED N THE STREAM STABILIZATION/ FISHERIES ENHANCEMENT
WORK.
13. THROUGHOUT PROJECT AREA THE ENGINEER MAY DESIGNATE AREAS FOR REVEGETATION.
LOD PLACEMENT OR OTHER HABITAT IMPROVEMENTS NOT SPECIFICALLY NOTED ON THESE
BRG
BEARING
FT
FEET OR FOOT
QO
OUTSIDE DIAMETER
T & B TOP AND BOTTOM
3. CONSTRUCT ROAD REPAIRS - LIMIT OPEN WORK AREA TO 200'. MAX.
PLANS.
B & S
BELL AND SPIGOT
FTG
FOOTING
ORIGINAL
T & G TONGUE AND GROOVE
14. THE CONTRACTOR SHALL PLACE ANY WASTE MATERIALS SUITABLE FOR LOD AS DIRECTED
BV
BUTTERFLY VALVE
oMG
TAN
TANGENT
4. FINISH GRADE AND CLEANUP ALL CONSTRUCTED AREAS.
BY THE ENGINEER.
G
GAS
p
POLE
TB
TELEPHONE BOX
5. INSTALL PLANTINGS AND HYDROSEED ALL DISTURBED AREAS.
15. ELEVATION OF FINISH GRADE FOR ROADWAY RECONSTRUCTION SHALL MATCH THE EXIST. GRADE:
BVC
BEGIN VERTICAL CURVE
GAGE
PC
POINT OF CURVATURE
CONTRACTOR SHALL ESTABLISH GRADE WITH STRING LINE AND OFFSET GRADE TO THE SIDE OF
CB
CATCH BASIN
GA
TBE
THREAD BOLT ENDS
6. REMOVE EROSION/ SEDIMENTATION CONTROLS.
ROADWAY AT 50 FT. INTERVALS.
CE
CONSTRUCTION EASEMENT
GALV
GALVANIZED
PCC
PE
PONT OF COMPOUND UND CURVATURE
PLAN END
TBC
TOP OF BACK OF CURB
16. FINISH GRADE FOR RAISE ROAD GRADE SHALL BE DETERMINED IN THE FIELD USING STRING LINE
GP
GALVANIZED IRON PPE
PIED
PEDESTAL
TOP
TOP OF PIPE
STREAM/ FISHERIES ENHANCEMENT-
OR OTHER APPROVED METHOD.
CFH
CUBIC FEET PER HOUR
GPO
GALLONS PER DAY
PELF
PERFORATED
TBM
TEMPORARY BENCH MARK
L SCHEDULE ELECTRO- SHOCKW (OF FISH) WITH THE CITY 48 HOURS IN ADVANCE. OF
17. ALL FINISH GRADE ELEVATIONS SHALL BE REVIEWED AND APPROVED BY THE ENGINEER PRIOR
CFM
CUBIC FEET PER MINUTE
GPH
GALLONS PER HOUR
PI
POINT OF INTERSECTION
TEl
TELEPHONE
CONSTRUCTION'
TO CONSTRUCTION OF THE WORK.
CFS
CUBIC FEET PER SECOND
GPM
GALLONS PER MINUTE
PK NAIL
TEMP'
TEMPORARY
Z. INSTALL STREAM DIVERSION AROUND THE WORK AREA USING SANDBAG DIKES, CULVERTS
18. THE CONTRACTOR SHALL PROVIDE SMOOTH ROAD TRANSITIONS TO AND FROM ALL AREAS
CHK V
CHECK VALVE
PL
PL
PLATE OR PROPERTY LNf
TH
THICK OR THICKNESS
OR OTHER ACCEPTABLE MEANS APPROVED BY THE ENGINEER
DESIGNATED TO BE RECONSTRUCTED OR RAISED. TRANSITION SLOPES SHALL NOT EXCEED
CIP
CAST IRON PIPE
GiD
GLADE OR GROUND
POC
POINT ON CURVE
TM
TELEPHONE MANHOLE
3. CONSTRUCT STREAM/ FISHERIES ENHANCEMENTS MAINTAINING THE SEPARATION OF THE
I VERT TO 20 HORIZ (5%).
CL
CENTER LINE
GR BRK
GRADE CHANGE
POT
POINT O_ d TANGENT
TP
ONE POLE OR
TELEPHONE
WORK FROM THE STREAM.
CMP
CORRUGATED METAL PPE
GV
GATE VALVE
PP
POWER POLE
TELEGRAPH POLE
4. REMOVE THE STREAM DIVERSION, AS APPROVED BY THE ENGINEER.
CMPA CORRUGATED METAL PIPE ARCH
PRESS PRESSURE
TYP TYPICAL
5. PLANT MATERIAL USED FOR LIVESTAKNG WILL BE COLLECTED
CO
CLEANOUT
pRC
POINT' OF REVERSE CUB
IN THOSE AREAS NOTED ON THE DRAWINGS AND AS APPROVED BY THE ENGINEER
COB
CLEANOUT BOX
HAP
HORIZONTAL ANGLE PONT
PRV
PRESSURE REGULATING. RELIEF
UG
UNDERGROUND
6, INSTALL PLANTINGS AS SHOWN AND HYDROSEED ALL ON -SHORE DISTURBED AREAS.
HORIZ
HORIZONTAL
OR REDUCING VALVE
UGC
UNDERGROUND CONDUIT
COL
COLUMN
HWL
HIGH WATER LEVEL
PSF
POUNDS PER SQUARE FOOT
USGS
UNITED STATES GEOLOGICAL
CONC
CONCRETE
HWY
HIGHWAY
PSI
POUNDS PER INCH
SURVEY..
CCP
CONCRETE CYLINDER PIPE
HPI
HORIZONTAL' POINT OF
PT
.SQUARE
PONT POINT � TANGENCY OR POINT
C
VERTICAL CURVE
CTR
CENTER
INTERSECTION
PVC
VINYL
POLY CHLORIDE
VCP
VITRIFIED CLAY PIPE
CY
CUBIC YARDS
PVMT
PAVEMENT
VERT
VERTICAL
CLR
CLEAR
ID
INSIDE DIAMETER
PWR
POWER
VOL
VOLUME
COORD
COORDINATE
N
(NCH
OTy
QUANTITY
VPi.
VERTICAL POINT
CONT
CONTINUOUS
IE
INVERT ELEVATION
OF ,INTERSECTION
COMPT
CONST
COMPACT OR COMPACTION
CONSTRUCTION OR CONSTRUCT
INST
INSTALLATION OR INSTALL
R
RC
RADIUS
REINFORCED CONCRETE
WM
WATER METER /WATER MAN
CPEP
CORRUGATED POLYETHYLENE PIPE
INV
INVERT
RCP
REINFORCED CONCRETE PIPE
W
WEST OR WATER
IPS
IRON PIPE SIZE
W/
WITH
DET
DETAIL
IRRG
IRRIGATION
RD
ROAD
WT
WEIGHT
DI
DUCTILE IRON
RDwD
REDWOOD
DIA
DIAMETER
RED
REDUCER OR REDUCING
WWM
WELDED WIRE MESH
DIP
DUCTILE IRON PIPE
REF
REFERENCE OR REFER
W/O
WITHOUT
DIST
DISTANCE
WV
WATER VALVE
DIP
DUCTILE IRON PIPE
REINF
REINFORCING OR REINFORCED
W LAT
WATER LATERAL
ON
DOWN
REOD
REQUIRED
DWG
DRAWING
RP
RADIUS POINT
YD
YARD
SECTION AND DETAIL IDENTIFICATION
NOTE DETAIL IDENTIFICATION
DETAIL IDENTIFICATION
DETAIL LETTER -�� H DRAWING ON WHIC
}�
D /C -6
DETAIL APPEARS
W DETAIL SHOWN AN DRAWING G -I AS:
FT-
-,—DETAIL LETTER
SECTION IDENTIFICATION
DRAWING ON WHICH
I G/, -12 ""
4S4w2O29
(1) SECTION CUT SHOWN ON DRAWING AS:
SECTION NUMBER
DETAIL APPEARS
CITY OF REINTON
(2) ON SHEET NUMBER GC -I THIS DETAIL IDENTIFIED AS:
DEPARTMENT OF PUBLIC WORKS
—DRAWING ON WHICH
SECTION APPEARS
DETAIL LETTER
HONEY CREEK INTERIM REPAIRS
G-2
DETAIL NAME
A F_---
RECORD DRAWING
SEE ORIGINAL CONTRACT DRAWINGS
AND
yjjy�P -22 -2029 ABBREVGENORAL NOTES
suaMiTTEO
WARNING
G -I
DRAWING FROM wwcH
DETAIL APPEARS
FOR SEAL AND SIGNATURES
I
DESIGNED:
DRAWN:
DATE: 593
FILE NAME:
O Vi I
PROJECT ENGINEER R.C.E. \�. DACE
SCALE: NONE
FIELD BOON: PAGE
IF THIS BAR DOES
NOT MEASURE I'
D RECORD DRAVYGJG
CHECKED:
I DPA
JEB
9 -24 -93
THEN DRAWING IS
BY
APPR.
I DATE
SHEET: G -Z OF:
MONTGOMERY WATSON R. c. E. N0. DATE NOT TO SCALE.
NC. I REVISION
IX I I I I I AI I I I I I I I% I Y I Y I A I I 1 i I .$ F 4 s T