HomeMy WebLinkAboutS-218906GENERAL NOTES 1 6. 7. 8. 9. 10. 11. 12. 13. 14. EXISTING SITE IMPROVEMENTS SHOWN ARE BASED UPON A. SURVEY BY INCA ENGINEERS, INC., DATED 5/18/95 AND CITY OF RENTON RECORDS. NO WARRANTY OR GUARANTEE OF ACCURACY OR COMPLETENESS IS EITHER IMPLIED OR EXPRESSED. EXISTING UNDERGROUND UTILITIES AND IMPROVEMENTS HAVE BEEN SHOWN ON THESE DRAWINGS FOR THE PURPOSE OF ASSISTING THE CONTRACTOR IN LOCATING SAID UTILITIES AND IMPROVEMENTS IN THE FIELD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ACTUAL LOCATIONS IN THE FIELD AND CHECKING WITH APPROPRIATE AGENCIES THAT MAY HAVE UNDERGROUND UTILITIES AND IMPROVEMENTS WITHIN THE PROJECT LIMITS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY AND ALL DAMAGE TO UNDERGROUND UTILITIES AND IMPROVEMENTS RESULTING FROM HIS OPERATION. A COPY OF THE APPROVED PLANS AND SPECIFICATIONS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. DATUM — ELEVATIONS SHOWN ON CITY OF RENTON DATUM (NATIONAL GEODETIC VERTICAL DATUM), AND ARE BASED ON CITY OF RENTON BENCH MARKS. IT SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND OTHER RELATED OR REQUIRED PERMITS PRIOR TO ANY CONSTRUCTION ACTIVITY. THE CONTRACTOR SHALL ADJUST ALL NEW AND EXISTING MANHOLE RIMS, DRAINAGE STRUCTURE LIDS, VALVE BOXES, AND UTILITY ACCESS STRUCTURES TO FINISHED GRADE WITHIN AREAS AFFECTED BY THE PROPOSED IMPROVEMENTS. IN PAVED AREAS, ALL MANHOLE COVERS SHALL SLOPE TO MATCH PAVING. ALL PAVEMENT, WALK AND CURB REMOVALS SHALL BE VERTICAL SAW CUT AT THE BOUNDARIES OF REMOVAL AREA. REMOVALS BEYOND LIMITS SHOWN ARE AT CONTRACTOR'S EXPENSE AND SHALL BE INCLUDED IN THE TOTAL CONTRACT PRICE. CONTRACTOR SHALL RESTORE OR REPLACE ALL PAVEMENT, WALKS, CURBS, DRIVEWAYS, WALLS, ROCKERIES, LANDSCAPING INCLUDING LAWN. FENCES, UTILITIES, METERS, VAULTS, MAILBOXES AND SIGNS, OR RELATED ITEMS DAMAGED BY CONSTRUCTION TO ORIGINAL OR BETTER CONDITION. THE HOURS OF WORK IN STREET RIGHT —OF —WAY SHALL BE LIMITED TO 7:00 AM TO 5:00 PM ON WEEKDAYS ONLY (UNLESS OTHERWISE ,APPROVED IN WRITING BY PUBLIC WORKS AT 235 - 2635). SEE SPECIAL PROVISIONS FOR LANE CLOSURE REQUIREMENTS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND EMERGENCY 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF WORK. UTILITY CROSSING LOCATIONS AND ELEVATIONS SHALL BE VERIFIED BY THE CONTRACTOR A MINIMUM OF FIVE (5) PIPE LENGTHS IN ADVANCE OF NEW MAIN. PROVIDE ETHAFOAM PAD WHERE CLEARANCE BETWEEN NEW AND EXISTING UTILITY LINES AT CROSSINGS IS LESS THAN 1'. CONTRACTOR SHALL PROVIDE BYPASS PUMPING WHERE NECESSARY TO MAKE CONNECTIONS AND CONSTRUCT ALL PIPING AND APPURTENANCES. ALL BYPASS PUMPING METHODS SHALL BE APPROVED BY THE ENGINEER. ALL COSTS ASSOCIATED WITH PUMPING SHALL BE INCIDENTAL TO THE CONTRACT. INSTALLATION OF 45 DEC. WYE FITTING FOR SIDE SEWER CONNECTION TO MAIN SHALL BE ALLOWED ONLY IF APPROVED BY THE ENGINEER. CONTRACTOR SHALL RE---POSITION SIDE SEWER ALIGNMENT, IF NECESSARY, TO AVOID DISRUPTION OR DAMAGE OF EXISTING UTILITY SERVICES. NO SIDE SEWER SHALL BE CONNECTED TO THE NEW SEWER MAIN PRIOR TO TESTING AND FINAL ACCEPTANCE OF MAIN, UNLESS APPROVED BY THE ENGINEER. CITY OF RENTON STANDARD DETAILS ARE LOCATED WITHIN THE BOUND CONTRACT DOCUMENTS. ALL DUCTILE IRON PIPE FOR WATERMAINS SHALL BE CLASS 52 UNLESS OTHERWISE NOTED. ww p- j7-1/'89 SEE DETAIL FOR PAVEMENT REPAIR SELECT IMPORTED a a D BACKFILL CONFORMING TO SEC 9 -03.19 COMPACTED IN 12" MAX LIFTS TO 95% MAX. DRY DENSITY BEDDING MATERIAL I N PER WSDOT APWA. 9 -03.9 (3) CRUSHED SURFACING TOP d COURSE COMPACTED TO 95% DENSITY I t I FOUNDATION MATERIAL — 1 WHERE UNSUITABLE TRENCH FOUNDATION EXISTS W (PAY LIMIT) W = 48" FOR PIPE < 15" I.D. SEWER SEE DETAIL FOR PAVEMENT REPAIR SELECT IMPORTED a a q BACKFILL CONFORMING TO SEC 9 -03.19 COMPACTED IN 12" MAX LIFTS TO 95% MAX. DRY DENSITY a .0 ° I I 1 I FOUNDATION MATERIAL TRENCH WHERE UNSUITABLE W (PAY LIMIT) FOUNDATION EXISTS W = 48" FOR PIPE < 15" I.D. WATER SEWER PIPE & WATER PIPE BEDDING DETAIL 8 NOT TO SCALE APPROX. EDGE OF EXISTING CONC. PANEL, UNDER EXISTING OVERLAY. REMOVE PAVEMENT PANEL FROM EXISTING JOINT. SEE DETAIL 4 FOR PAVEMENT REPAIR 8 PAVEMENT 11' OR 22' PER PLAN 3 5' OR PER PLAN - VERIFY EDGES OF EXISTING CONCRETE PANEL (UNDER OVERLAY) ARE ALIGNED WITH EDGES OF TRAFFIC LANE. IF CONDITIONS ARE OTHERWISE, NOTIFY ENGINEER IMMEDIATELY. (TYP.) SELECT IMPORTED BACKFILL PER 1 DETAIL 8 12" WATER PIPE WITH POLYETHYLENE 8" SANITARY / \/ / WRAP SEWER PIPE WITH POLYETHYLENE WRAP SEE DETAILe FOR PIPE 9' TRENCH (PAY LIMIT) BEDDING 8 NOTE: REMOVE EXISTING DEACTIVATED 6" C.I. GAS LINE BETWEEN S. 2ND & S. 3RD ST. AS REQUIRED TO INSTALL NEW WATER PIPE. APPROX. LOCATION IS 9' WEST OF CENTERLINE SEWER AND WATER TRENCH SECTION 8 NOT TO SCALE STA. 20 +70 TO STA. 27+15 RO L L'1 4 9 37 APPROX. EDGE OF EXISTING CONC. PANEL, UNDER EXISTING OVERLAY. REMOVE PAVEMENT PANEL FROM EXISTING JOINT. VERIFY EDGES OF SELECT IMPORTED BACKFILL PER 1 DETAIL 8 EXISTING CONCRETE PANEL (UNDER OVERLAY) SEE DETAIL 4 ARE ALIGNED FOR PAVEMENT CE REPAIR 8 WITH EDGES OF TRAFFIC EXISTING RIGID BASE 12" LANE. IF CONDITIONS PAVEMENT \ ARE OTHERWISE, 11' (PAY LIMIT) NOTIFY ENGINEER COMPACTED CRUSHED SURFACING TOP COURSE. M M E D IATELY. SEE DETAIL FOR PIPE BEDDING 8 8" SANITARY SEWER PIPE SEWER TRENCH SECTION 8 NOT TO SCALE STA. 10 +00 TO STA. 19+85 SAW CUT & TACK COAT. SEAL AFTER ASPHALT CEMENT CONCRETE, PORTLAND CEMENT CONCRETE PAVING CL. B (3 -3/4" TO 5 -3/4" THICK PAVEMENT, 3 DAY /3000 PSI MIX, 2 LIFT MATCH EXIST. 8" THICK REMOVE LOOSENED TRIM ASP VERTICALLY S _v R e D E S I G N C O M P A N Y 911 W t _ A ' N \ii /iii 3/4" DIA. x 12" LONG \ /T\ \ii` \ `�i z O SELECT IMPORTED BACKFILL PER 1 DETAIL 8 DOWEL BAR ® 18" ON SEE DETAIL FOR PIPE BEDDING 8 8" SANITARY SEWER PIPE SEWER TRENCH SECTION 8 NOT TO SCALE STA. 10 +00 TO STA. 19+85 SAW CUT & TACK COAT. SEAL AFTER ASPHALT CEMENT CONCRETE, PORTLAND CEMENT CONCRETE PAVING CL. B (3 -3/4" TO 5 -3/4" THICK PAVEMENT, 3 DAY /3000 PSI MIX, 2 LIFT MATCH EXIST. 8" THICK REMOVE LOOSENED TRIM ASP VERTICALLY S _v R e D E S I G N C O M P A N Y 911 W t _ A ' N \ii /iii 3/4" DIA. x 12" LONG \ /T\ \ii` \ `�i z O es rn venue Suite 302 Seattle, WA 98104 DOWEL BAR ® 18" ON Phone 206.223.0326 CENTER (EPDXY COATED) k EXISTING RIGID BASE 12" QQ of MIN. v 4 95 aTm, e COMPACTED CRUSHED SURFACING TOP COURSE. 2/49 COMPACT TO 95% DENSITY pies COMPACTED TRENCH f 1 RECOMMENDED FOR APPROVAL BACKFILL PER DETAIL 8 PLAN REVIEW DATE CALL 48 HOURS BEFORE YOU DIG 1-800-424-5555 4 PAVEMENT REPAIR WASTEWATER UTILITY DATE 8 NOT TO SCALE WATER UTILITY DATE CITY OF RENTON DEPARTMENT OF PUBLIC WORKS MAIN AVENUE SOUTH UTILITIES REPLACEMENT GENERAL NOTES AND DETAILS DESIGNED: MAK DATE: 3 OCT 1995 FILE NAME: 5006 DRAWN: JZ /PMR MAINDEII CHECKED: TVS SCALEAS NOTED BELD sooK: REVISION BY APPR. DATE APPROVED: SHEET: 8 OF: 9