Loading...
HomeMy WebLinkAboutS-223906Z 0 F 4 O J W Z Z W te a_ va �� z or a of ? 9 W Y � D mya��W i K W U7 F2 JU)U U DU1 S r 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 MICROBOX R147 1710 10 5 I I I I I A I I I IA 1 1 6 7 8 9 10 11 12 13 14 15 Sff Yo i3 / 16 17 18 19 OLYMPIC FOUNDRY MH 30 NTH 111 "x17A" CONCRETE METER BOX W WITH pie" STEEL DIAMOND PLATE. z ADJUSTING RINGS 24" MH 30 D/T OR EQUAL CAST IRON OR DUCTILE IRON TRANSITION COUPLING PIPE TO COVER. OR BLOCKS ids REQUIRED CAST IRON TEE UNDISTURBED SOIL TO FIT �I qi M.J.xM.J.xM.J. SEWER LINE 0 ADAPTOR 4 "MIN. /12 "MAX. = a COLLAR — 0 oz: . a PRECAST VALVE­,, CHAMBER CONE ' x J c < 0 I PLUG, M.J. WITH GASKET, BOTH CUT IN HALF 18 " 0) FORD COPPERSETTER - WATER METER TO r z VH172-15W r BE SUPPLIED BY RUBBER CAST IRON OR THE CITY GASKET z MANHOLE WALL DUCTILE IRON WATERMAIN 8 "/12" PIPE g o. TYPE "K" SOFT DUCTILE IRON PIPE CLASS 50, _ TYPE "K" SOFT COPPER TUBING CEMENT LINED, LENGTH TO FIT. 22 COPPER TUBING POURED IN­-- N PLACE BASE .: a. ' • , . tO - -- I_ 48" I 7 • • CAST IRON 90' BEND LOOP DOWN TO CENTERLINE OF WATER CONNECT TO EX. SERVICE i- M.J.xP.E. CORPORATION STOP MAIN TO PROVIDE SLACK IN COPPER SERVICE LINE TO METER FORD TAPERED THREAD CLASS C CONCRETE (CC) =PACK JOINT (J -3401) SPECIAL SHALLQW MANHOLE DROP CONNECTION n LESS THAN 4 —0 DEEP UT13 „ -Y4 WATER SERVICE N.T.S. UT13 N.T.S. T - 4" MIN. 24» BEDDING GRAVEL, 12" MAX. CASTING - OLYMPIC FDRY. COMPACTED #MH 30 D/T OR EQUAL x �- FOUNDATION GRAVEL, 00, r- —� Q � 24 m: Q ADJUSTMENT 4" MIN. o ° °o ° oOo ° °o ° 00 °o °o ° o 0o 0 0 00 IF REQUIRED ORDINARY PIPE BEDDING N FOR 4° PIPE rn PRECAST SECTION I o M = > i 4" MIN. `OI 4" 54" N = a W x " STEPS -3/4 DEFORMED BEDDING GRAVEL, COMPACTED BAR STEPS SHALL BE 48" INCLUDED ;• . ' a 6 1 2" -'i GENERAL NOTES: t-O7— FOUNDATION GRAVEL, 6" z 1. IN UNIMPROVED AREAS, MANHOLE I 00000000000aoo�oo ° °o !F REQUIRED TO EXTEND MINIMUM 6" AND MAXIMUM 18" ABOVE FINISHED ORDINARY PIPE BEDDING it LADDER -STD. ALUMINUM GRADE. IN PAVED AREA, COVER FOR 6" AND LARGER PIPES NOTES: OR GALVANIZED STEEL MUST SLOPE IN ALL DIRECTIONS 1. STEPS TO BE 3/4 "0 DEFORMED BAR GALVANIZED MAX. PIPE SIZE- 21 "I.D. TO MATCH PAVING. —. SAFETY STEPS OR EQUAL 2. TYPE 3 72 INCH MANHOLES SHALL .. a CONCRETE cc 2. STEPS ARE TO BE IN PLACE BEFORE MH SECTIONS ARE INSTALLED. MORTAR CONCRETE SHELF BE IN ACCORDANCE WITH STD. a ° 3. CASTING TO BE OLYMPIC FOUNDRY MH 30 WITH FILLET PLAN B23C , WITH OLYMPIC FDRY. NO. MH 30 D/L OR EQUAL FRAME " MH 30 D /T OR EQUAL. PRECAST BASE SECTION AND COVER. 4. MANHOLE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE. OR CAST IN PLACE 6" MIN. FOUNDATION GRAVEL, °o °o °o °o�o�000�o�° °° IF REQUIRED 5. OPENING SHOULD BE ON DOWNSTREAM SIDE. a• °••N., _ZNAUG�c� CONCRETE ENCASEMENT WN f4 r V > MANHOLE 4' -0 "- TO 7' -0" DEEP ' ' " MANHOLE OVER 7-0 DEEP �� � '' � �Fi�� PIPE BEDDING CLASSES , �l�rsne! N.T.S. - N.T.S. - FlLENAME: UT22 REGION STATE FED. AID PROJ. N0, SNOT TRETt� 1 II�.7ar7��AY DIr1�7iOIV — — — AP RO Washingt ®n State �@ �'t�i1®nt Transportation P SR 406 TUKWILA TO SUNSET BLVD CEDAR RIVER PIPELINES- RELOCATION n UT22 PLOT DATE: 8/27/90 10 WASH ACI- 405 - 3(780) DRAWN G.O. CHECKED DNP as NUMBER 90WO69 SHEET 119 OF 317 SHEETS D Sol ADM R.Q. ANDERSON 8030/ 0 REVISED MANHOLE AND DROP CONNECTION DETAILS DNP CON7RACY HUMBER 3 8 -5-/ UR RoseWafer Engineering, Inc. UTILITY DETAILS APP,D S r 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 MICROBOX R147 1710 10 5 I I I I I A I I I IA 1 1 6 7 8 9 10 11 12 13 14 15 Sff Yo i3 / 16 17 18 19