HomeMy WebLinkAboutS-272215vl
�,
fN
�) ,
N
N=
z
N
1 -
l� z3=
N 3
A r<
�-
N �
N � �^
1� � _ € rn
N 3 � � �� WIDTH VARIES
� ? MATCH EXISTING }
� a
o N 3 3
I o MIN. 3° ASPHALT LL
� F CONCRETE (1 LIFT) °
� x
� �
R
d
15
i
3a
A
Qo
mo
o�
wz N
N.0
O � 3�
a
�z �-
�w
I�-t WW a °-
�ix �o
�E
_�
_�
°5v
� ��
c
o �,
a�
\��
.N�
PAY LIMIT
TRENCH BACKFlLL
6' -0° FOR 8 °, 10" ANO 12' MAIN LINES
AND 4' FOR 6° SIDE SEWERS
J-
�._o.
T6'
I ° e ° EXCAVATION OF UNSUITABLE SOIL
AND BACKFlLL OF FOUNDATION
° ° � MATERIAL (IF NECESSARY) DEPTH
AS APPROVED BY ENGINEER
MATERIAL SHALL MEET SECTION
9- 03.9(1) BALLAST
6 ". 8 ". 10" AND 12" PVC SEWER
TYPICAL TRENCH BEDDING AND BACKFlLL
NOTES:
t. PROVIDE UNIFORM SUPPORT UNDER BARREL
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT PIPE ZONE MATERIAL TO 90� MINIMUM DENSITY
EXCEPT DIRECTLY OVER PIPE WHERE COMPACTION WILL BE
HAND TAMP ONLY.
4. PIPE MUST BE ANCHORED IN SUCH A MANNER AS TO ENSURE
FLOW LINE IS MAINTAINED.
5. ALL EXCAVATION AND BEDDING AND BACKFTLL MATERIALS
BEYOND PAY LIMIT OF TRENCH SHALL BE INGLUUED WITHIN
THE TRENCH EXCAVATION SAFETY SYSTEMS BID ITEM.
24 "x 6" FRAME AND LIP
PER DRAWING BR29.
4" MIN. TO
. " l2" MAX.
.� do
�.- I 2a"
72" DIAMETER Iv1H �4
(Sheet 3)
NOTES:
1. STEPS TO BE 3/4" DEFORMED BAR GALVANIZED
SAFETY STEPS OR EQUAL
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE
SECTIONS ARE INSTALLED.
3. CASTING TO BE PER DRAWING BR29.
zo 4. MANHOLE SECTIONS TO BE OF REINFORCED
N PRECAST CONCRETE.
5. OPENING SHOULD SE ON DOWNSTREAM SIDE.
�i 6. ALL JOINTS SHALL BE GROUTED.
� 7. SANITARY SEWER MANHOLES SHALL HAVE ALL
INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS
URETHANE COATING; WASSER MC- CONSEAL OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
KITH ASTM C -443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE
INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING
GPK ADAPTOR, KOR -N -SEAL B00T5 OR APPROVED EQUAL.
o wwp I7 -a7az
10" to S. 5th St.
VI
N
3
E
w
0
V)
a'
v
3
0
12" from S. 5th St.
CHANNELING DETAIL for 72" DIAMETER MH �4
(Sheet 3)
. • • ' �
12°
TYP
PATCH PAYMuvT
TRENCH WIDTH PER APPROPRIATE
DETAIL PLUS 2' -0"
ASPHALT CONCRETE PAVEMENT
RESTORATION DETAIL
NTS
SAWCUT FlNAL JOINT
TYP. EACH SIDE
`EXIST. ASPH. CONC.
PAVEMENT, TYP.
3" CL '8' ASPHALT
CONCRETE PATCH ( 1 LIFT )
- 6" CRUSHED SURFACING
TOP COURSE
BACKFlLL
(SEE BEODINGfBACKFlLL DETAIL)
NOTES:
t. ALL TRENCHES IN ROADWAY AREAS SHALL 8E BACKFILLED AND PATCHED
PER SPECAL PROVISION 5 -06.1 AT END OF EACH WORK DAY.
THIS WORK IS INCIDENTAL TO ALL TRENCH RESTORATION WORK.
2. THE FlNAL SAWWT JOINT SHALL BE A MINIMUM OF 1' BEYOND
THE UNDISTURBED EDGE OF THE TRENCH.
3. ALL ASPHALT PATCH AREA OUTSIDE OF PAY LIMIT SHOWN SHALL
BE CONSIDERED INCDENTAL TO OTHER ITEMS OF WORK.
4. ALL TEMPORARY PATCHES ON TRENCHES SHALL BE PERMANENTLY PATCHED
WITHIN {2) WEEKS OF COMPLETION OR WORK WITHIN THE ROADWAY AREA
UNLESS APPROVED BY THE ENGINEER.
5. SEE CONSTRUCTION NOTES 15 AND i6 ON THIS SHEET FOR PAVING AND
CONSTRUCTIQN CONSTRAINTS ON PORTIONS OF BURNETT AVE S, WILLIAMS AVE S
AND WELLS AVE S.
REMOVE TDP 2'
OF MANHOLE
AND RESTORE PER ASPHALT
:CONCRETE PAVEMENT DETAIL
CRUSHED ROCK
(DEPTH VARIES)
�, I � MAX. I' CONCRETE OR CDF
ABANDON MANHOLE TYPICAL DETAIL
{Sheet 11: Station 61 +12. 9.85 RT)
NOT TO SCALE
NOTES:
1. CONCRETE OR CONTROL DENSITY FlLL SHALL
BE POURED TO A DEPTH OF NOT MORE THAN
1 FOOT ABOVE THE CROWN OF THE NEW
CURED -IN -PLACE LINER.
2. AFTER CONCRETE OR CONTROL DENSITY FILL
HAS CURED, FILL REMAINDER OF MANHOLE
WITH 1 -1 /4" CRUSHED ROCK OR APPROVED
EQUAL.
5- ?7 ? ?IS
INSIDE DROP CONNECTION
TO EXISTING MANHOLE
(Sheet i 8: Station 99 +93.86. 7.17' LT)
NTS
NOTES:
1. ALL PIPE SHALL BE SIMILAR MATERIAL AS MAINLINE.
2. STAINLESS STEEL STRAPS SHALL BE 2" X 1/8"
STAINLESS STEEL PLATE WITH 2 - 5/8" HOLES.
CONNECPON TO MANHOLE SHALL BE MADE USING
1/2" STAINLESS STEEL ANCHOR BOLTS WITH
BACKING AND LOCKING NUTS. SPACING BETWEEN
STRAPS SHALL BE AT 3 FEET ON- CENTER. A
MINIMUM OF 2 STRAPS SHALL BE USED FOR EACH
DROP.
CONSTRUCTION NOTES
7. TRENCH SAFELY AND SHORING SHALL BE PER SECTION 7- 08.3(7)8 OF THE SPECIAL
PROVISIONS. TRENCHES SHALL BE SEALED TO PREVENT ENTRY DURING NON- WORKING
HOURS.
2 VERTICAL CONTROL DATUM BASED ON NAVD 1988 (IN FEET)
3. UTILITY CROSSING LOCATIONS AND ELEVATIONS SHALL BE DETERMINED BY THE
CONTRACTOR IN ADVANCE OF ANY CONSTRUCTION ACTIVITIES.
4. EXISTING PRIVATE IMPROVEMENTS SHALL BE TEMPORARILY RELOCATED AND
PERMANENTLY REPLACED TO ACCOMMODATE SERVICE CONSTRUCTION.
5. STARONING SHOWN IN CENTERLINE OF ROADWAY OR SURVEY CONTROL LINES
AS DEFlNED BY THE CONTROL POINTS.
6. ALL MANHOLES SHALL HAVE LOCKING LIDS.
7. MATCH FINISH GRADE Willi ALL MANHOLE LIDS.
8. PROVIDE AS -BUILT INFORMATION SHOWING ALL INVERT AND RIM ELEVATIONS
OF MANHOLE AND CATCH BASINS AND SIDE SEWER VERTICAL AND HORIZONTAL LOCATIONS.
9.- INSTALL SEWER MAIN AND SERVICES A MINIMUM 2' FROM PARALLEL GAS LINES
WHERE CONFLCT OCCURS.
10. ALL CEMENT CONCRETE DRIVEWAYS AND ALLEY APPROACHES SHALL BE 6"
THICK. (IN ACCORDANCE WITH STANDARD PLAN �'F006, DRAWING �%FRO1 N).
71. REPLACE ALL DISNRBED CURB &GUTTERS IN ACCORDANCE WITH STANDARD
PLAN # F008, DRAtWNG � FR05 ANC STANDARD P�..N � F.,�� "CEMENT CONCRETE
CURB AND GUTTER."
12. REPLACE ALL DISTURBED SIDEWALK IN ACCORDANCE WITH STANDARD PLAN
„ M,-,, DRAWING ;y FROZ.
73. WHERE UTILITY PIPE LINE V'cRTiCAL SEPARATON IS LE55 THAN (1) ONE FOOT,
INSERT ETHAFOAM HS 600 PLANK -FOAM BOARD OR EQUAL AS CLEARANCE
SEPARATION.
14. FINP.L PAVING OF WELLS AVE. S. AND WILLIAMS AVE. S. FROM 5. 3RD ST. THROUGH
THE INTERSECTION OF S. 4TH ST. SHALL BE COMPLETED PRIOR TO JULY 76, 1999.
IF A TOTAL AND FlNAL RESTORATION OF THESE BLOCKS CANNOT BE COMPLETED BY
THE SPECIFlED DAIS, THEN NO EXCAVATION WORK SHALL TAKE PLACE IN liiESE BLOCKS
UNTIL AFTER AUGUST 2, 1999.
75. ALL WORK ON BURNETT AVE. S. BETWEEN S. 3rd ST. RND S. 4th ST. SHALL BE COMPLETED
PRIOR TO SEPTEMBER 15, 1999.
16. REFER TO SHEET 7 FOR INFORMATION REGARDING THE COMMERCIAL LAUNDRY LOCATED AT
THE CORNER OF WELLS AVE. 5. AND S. 4th ST.
77. SIDE SEWERS SHOWN ON THE PLANS WERE LOCATED VIA TELEVIDEO. BECAUSE THE LOW
POINTS IN THE EXISP.NG MAIN LINE WERE UNDER WATER, SOME ACTIVE SIDE SEWERS MAY
NOT BE SHOWN. THE CONTRACTOR SHALL LOCATE AND REPLACE /RECONNECT ALL ACTIVE
SIDE SEWERS FROM THE NEW SEWER MAIN TO THE PROPERTY LINE UNLESS SPECIFlED
OTHERWISE ON THE PLANS.
SF-iEc i i
��` =�; �' � z � ='�! '- �CaNNF.D DEG 101999
STREET OVERLAY SCHEDULE
WELLS AVE S - EXTENTS OF OVERLAY SHALL BE
CURB TO CURB (36' WIDTH) AND
10' NORTH AND SOUTH OF PIPELINE
SEE DETAIL FOR STREET
REPLACEMENT.
R'ESTORATiCN R'cOUiREMENTS
WIWAMS AVE S - EXTENTS OF OVERLAY SHALL BE
CURB TO CURB (44' WIDTH) AND
10' NORTH AND SOUTH OF PIPELINE
SUBSEQUENT BACKFlLL MATERIAL
REPLACEMENT.
(NATIVE IF APPROVED BY ENGINEER)
BURNETT AVE S - EXTENTS OF OVERLAY SHALL BE
OR IMPORT PER SECTION 9- 03.72(1)C
BETWEEN EAST CURB OF STREET
(SELECT BACKFlLL) --
AND EAST EDGE OF ADJACENT
OF THE SPECIAL PROVISIONS.
PARKING AREA CURBS (APPROX.
18' WIDTH) AND 10' NORTH AND
SOUTH OF PIPELINE REPLACEMENT.
PROPOSED 6 ", 8 ", 10" AND 12" SEWER PIPE
SOUTH 5th ST - EXTENTS OF OVERLAY SHALL BE
THE NORTH HALF OF THE STREET
PIPE ZONE MATERIAL PER SECTION 9 -03.16
FROM A POINT 10' WEST OF CO# 2
TO WIWAMS AVE S, THE SOUTH HALF
BEDDING MATERIAL FOR FLEXIBLE PIPE
OF THE STREET FROM WIWAMS AVE 5
TO WELLS AVE S, AND FULL WIDTH
FROM WELLS AVE S TO A POINT 70'
EAST OF MHO 5.
24 "x 6" FRAME AND LIP
PER DRAWING BR29.
4" MIN. TO
. " l2" MAX.
.� do
�.- I 2a"
72" DIAMETER Iv1H �4
(Sheet 3)
NOTES:
1. STEPS TO BE 3/4" DEFORMED BAR GALVANIZED
SAFETY STEPS OR EQUAL
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE
SECTIONS ARE INSTALLED.
3. CASTING TO BE PER DRAWING BR29.
zo 4. MANHOLE SECTIONS TO BE OF REINFORCED
N PRECAST CONCRETE.
5. OPENING SHOULD SE ON DOWNSTREAM SIDE.
�i 6. ALL JOINTS SHALL BE GROUTED.
� 7. SANITARY SEWER MANHOLES SHALL HAVE ALL
INTERIOR SURFACES, INCLUDING CHANNELING,
COATED (SEALED) WITH A HIGH SOLIDS
URETHANE COATING; WASSER MC- CONSEAL OR
APPROVED EQUAL; COLOR OF COATING SHALL BE WHITE.
8. RUBBER GASKETED JOINTS SHALL BE IN CONFORMANCE
KITH ASTM C -443.
9. CHANNEL HEIGHT SHALL BE A MINIMUM OF 3/4 THE
INSIDE DIAMETER OF THE LARGEST PIPE.
10. CONNECTIONS TO MANHOLE SHALL BE MADE USING
GPK ADAPTOR, KOR -N -SEAL B00T5 OR APPROVED EQUAL.
o wwp I7 -a7az
10" to S. 5th St.
VI
N
3
E
w
0
V)
a'
v
3
0
12" from S. 5th St.
CHANNELING DETAIL for 72" DIAMETER MH �4
(Sheet 3)
. • • ' �
12°
TYP
PATCH PAYMuvT
TRENCH WIDTH PER APPROPRIATE
DETAIL PLUS 2' -0"
ASPHALT CONCRETE PAVEMENT
RESTORATION DETAIL
NTS
SAWCUT FlNAL JOINT
TYP. EACH SIDE
`EXIST. ASPH. CONC.
PAVEMENT, TYP.
3" CL '8' ASPHALT
CONCRETE PATCH ( 1 LIFT )
- 6" CRUSHED SURFACING
TOP COURSE
BACKFlLL
(SEE BEODINGfBACKFlLL DETAIL)
NOTES:
t. ALL TRENCHES IN ROADWAY AREAS SHALL 8E BACKFILLED AND PATCHED
PER SPECAL PROVISION 5 -06.1 AT END OF EACH WORK DAY.
THIS WORK IS INCIDENTAL TO ALL TRENCH RESTORATION WORK.
2. THE FlNAL SAWWT JOINT SHALL BE A MINIMUM OF 1' BEYOND
THE UNDISTURBED EDGE OF THE TRENCH.
3. ALL ASPHALT PATCH AREA OUTSIDE OF PAY LIMIT SHOWN SHALL
BE CONSIDERED INCDENTAL TO OTHER ITEMS OF WORK.
4. ALL TEMPORARY PATCHES ON TRENCHES SHALL BE PERMANENTLY PATCHED
WITHIN {2) WEEKS OF COMPLETION OR WORK WITHIN THE ROADWAY AREA
UNLESS APPROVED BY THE ENGINEER.
5. SEE CONSTRUCTION NOTES 15 AND i6 ON THIS SHEET FOR PAVING AND
CONSTRUCTIQN CONSTRAINTS ON PORTIONS OF BURNETT AVE S, WILLIAMS AVE S
AND WELLS AVE S.
REMOVE TDP 2'
OF MANHOLE
AND RESTORE PER ASPHALT
:CONCRETE PAVEMENT DETAIL
CRUSHED ROCK
(DEPTH VARIES)
�, I � MAX. I' CONCRETE OR CDF
ABANDON MANHOLE TYPICAL DETAIL
{Sheet 11: Station 61 +12. 9.85 RT)
NOT TO SCALE
NOTES:
1. CONCRETE OR CONTROL DENSITY FlLL SHALL
BE POURED TO A DEPTH OF NOT MORE THAN
1 FOOT ABOVE THE CROWN OF THE NEW
CURED -IN -PLACE LINER.
2. AFTER CONCRETE OR CONTROL DENSITY FILL
HAS CURED, FILL REMAINDER OF MANHOLE
WITH 1 -1 /4" CRUSHED ROCK OR APPROVED
EQUAL.
5- ?7 ? ?IS
INSIDE DROP CONNECTION
TO EXISTING MANHOLE
(Sheet i 8: Station 99 +93.86. 7.17' LT)
NTS
NOTES:
1. ALL PIPE SHALL BE SIMILAR MATERIAL AS MAINLINE.
2. STAINLESS STEEL STRAPS SHALL BE 2" X 1/8"
STAINLESS STEEL PLATE WITH 2 - 5/8" HOLES.
CONNECPON TO MANHOLE SHALL BE MADE USING
1/2" STAINLESS STEEL ANCHOR BOLTS WITH
BACKING AND LOCKING NUTS. SPACING BETWEEN
STRAPS SHALL BE AT 3 FEET ON- CENTER. A
MINIMUM OF 2 STRAPS SHALL BE USED FOR EACH
DROP.
CONSTRUCTION NOTES
7. TRENCH SAFELY AND SHORING SHALL BE PER SECTION 7- 08.3(7)8 OF THE SPECIAL
PROVISIONS. TRENCHES SHALL BE SEALED TO PREVENT ENTRY DURING NON- WORKING
HOURS.
2 VERTICAL CONTROL DATUM BASED ON NAVD 1988 (IN FEET)
3. UTILITY CROSSING LOCATIONS AND ELEVATIONS SHALL BE DETERMINED BY THE
CONTRACTOR IN ADVANCE OF ANY CONSTRUCTION ACTIVITIES.
4. EXISTING PRIVATE IMPROVEMENTS SHALL BE TEMPORARILY RELOCATED AND
PERMANENTLY REPLACED TO ACCOMMODATE SERVICE CONSTRUCTION.
5. STARONING SHOWN IN CENTERLINE OF ROADWAY OR SURVEY CONTROL LINES
AS DEFlNED BY THE CONTROL POINTS.
6. ALL MANHOLES SHALL HAVE LOCKING LIDS.
7. MATCH FINISH GRADE Willi ALL MANHOLE LIDS.
8. PROVIDE AS -BUILT INFORMATION SHOWING ALL INVERT AND RIM ELEVATIONS
OF MANHOLE AND CATCH BASINS AND SIDE SEWER VERTICAL AND HORIZONTAL LOCATIONS.
9.- INSTALL SEWER MAIN AND SERVICES A MINIMUM 2' FROM PARALLEL GAS LINES
WHERE CONFLCT OCCURS.
10. ALL CEMENT CONCRETE DRIVEWAYS AND ALLEY APPROACHES SHALL BE 6"
THICK. (IN ACCORDANCE WITH STANDARD PLAN �'F006, DRAWING �%FRO1 N).
71. REPLACE ALL DISNRBED CURB &GUTTERS IN ACCORDANCE WITH STANDARD
PLAN # F008, DRAtWNG � FR05 ANC STANDARD P�..N � F.,�� "CEMENT CONCRETE
CURB AND GUTTER."
12. REPLACE ALL DISTURBED SIDEWALK IN ACCORDANCE WITH STANDARD PLAN
„ M,-,, DRAWING ;y FROZ.
73. WHERE UTILITY PIPE LINE V'cRTiCAL SEPARATON IS LE55 THAN (1) ONE FOOT,
INSERT ETHAFOAM HS 600 PLANK -FOAM BOARD OR EQUAL AS CLEARANCE
SEPARATION.
14. FINP.L PAVING OF WELLS AVE. S. AND WILLIAMS AVE. S. FROM 5. 3RD ST. THROUGH
THE INTERSECTION OF S. 4TH ST. SHALL BE COMPLETED PRIOR TO JULY 76, 1999.
IF A TOTAL AND FlNAL RESTORATION OF THESE BLOCKS CANNOT BE COMPLETED BY
THE SPECIFlED DAIS, THEN NO EXCAVATION WORK SHALL TAKE PLACE IN liiESE BLOCKS
UNTIL AFTER AUGUST 2, 1999.
75. ALL WORK ON BURNETT AVE. S. BETWEEN S. 3rd ST. RND S. 4th ST. SHALL BE COMPLETED
PRIOR TO SEPTEMBER 15, 1999.
16. REFER TO SHEET 7 FOR INFORMATION REGARDING THE COMMERCIAL LAUNDRY LOCATED AT
THE CORNER OF WELLS AVE. 5. AND S. 4th ST.
77. SIDE SEWERS SHOWN ON THE PLANS WERE LOCATED VIA TELEVIDEO. BECAUSE THE LOW
POINTS IN THE EXISP.NG MAIN LINE WERE UNDER WATER, SOME ACTIVE SIDE SEWERS MAY
NOT BE SHOWN. THE CONTRACTOR SHALL LOCATE AND REPLACE /RECONNECT ALL ACTIVE
SIDE SEWERS FROM THE NEW SEWER MAIN TO THE PROPERTY LINE UNLESS SPECIFlED
OTHERWISE ON THE PLANS.
SF-iEc i i
��` =�; �' � z � ='�! '- �CaNNF.D DEG 101999