HomeMy WebLinkAboutS-296605LEFT BLANK INTENTIONALLY
1 -1,
3/4" SQUARES SPACED - 3/4"
AS INDICATED - HT. 1/8"
RAISE-1/2"
VIDE BORDER
CAST IRON RING AND COVER
12"0
FIBER
PACKIr
45• (1/8)
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTE:
IN UNIMPROVED AREAS POUR 1' -0" THICK
2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND
RING AND COVER.
IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING
AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36.
10/17/96 1 Added notes. DCV AG
DATE I REVISION I BY APPR'C
w
z
J
H
w
w
rn
Y
w
0_
0
PLUG TO BE SEALED
IN SAME MANNER AS
MAIN SEWER JOINTS.
CONCRETE
CLASS 3000
3/4„
6 INCH OR 8 INCH CLEAN -OUT
CITY OF RENTON
♦ i
STANDARD .PLANS
iST DATE: 12/96
DWG. NAME: BW18B SP PAGE: B076
o PROPERTY LINE
z
6' -0"
o FUTURE
6" BUILDING SEWER PIPE I BUILDING SEWER
5 a 13.DATUM SHALL BE CITY OF RENTON. U.S.C. AND G.S.
14.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR 60" ALLOWABLE MAX: TEE WITH 6" SIDE OUTLET
3 3 3 a OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR CAST:. IRON PIPE
0 o p a FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION OF OR DUCTILE IRON PIPE. - 2 "x 4" STUD SERVICE MARKER PAINT UPPER
CONSTRUCTION. PORTION WHITE ANS STENCIL ON SIDE
0 0 o w 1:3:.5 MIX p`'� _ _ WORDING "SEWER "` WITH 3" HIGH BLACK' LETTERS.
I I 15.ALL PIPE AND. APPURTENANCES SHALL BE. LAID ON A PROPERLY CONCRETE }' AND #6 WIRE WRAPPED AROUND THE STUD AND
° o PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(l) OF BLOCKING �. �P 2`' o v� EXTENDED TO 11iE TOP OF THE STUD.
THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR \� 1 NG
v v v > ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY R G�-� LOC�
0
00 m STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND Nth 9
BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING + 6" SIDE OUTLET TEE MG NGR� 2% MIN SLOPE
OF THE - TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL SEWER MAIN
AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING 6'� MIN. HORIZONTAL -
MATERIAL TO UNIFORM GARDE SO THAT THE ENTIRE LENGTH OF THE / UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
In a PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. CONCRETE BLOCKING ANGLE IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS`
zW W PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE OF IEE AT MAIN OVER 25 SEWER MAIN WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN.
W PIPE. ELEVATION -
VITRIFIED -CLAY, PLAIN AND REINFORCED CONCRETE, -D1 PL E' AND C1
�
16.SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC)
TYPICAL SIDE SEWER ELEVATION PIPE SEWER MAINS ARE TO BE CORE DRILLED
w
w w RUBBER GASKETED ASTM 3034, SDR 35, OR DUCTILE IRON CLASS 50. NOTE
of 0 17.IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 .INCHES.
UNLESS OTHERWISE. SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY
`0 T AND MAXIMUM 18 INCH ABOVE FINISHED GRADE. IN PAVED AREA, LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION,' WHICHEVER IS LOWER.
N 2 -� COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. PN \D W Cq
v °z v~ NOTE: AVOID CUTTING UNDERGROUND RECOMMENDED �. pF wasyisF`
o N UMUTY ONES Irs COSTLYI FOR' PROVAL
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
a a a IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE Call EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER— BY
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO s 284
w w w REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN before YOU Bl' 'nF 'vF�I57 EWE'J,�F4,
Of X Of Of
NOT
ESHOWN ENGINEER
S NOT SHOWN INETHEIRSPROPER FOR OCATION. IN BY ss /�NAL••EN�'`
n
CALL BEFORE YOU DIG: 1- 800 - 424 -5555 �0— iOG...
UNDERGROUND SERVICE (USA). EXPIRES 5 -13 -07
n C5
srtuv iwT vam uecss swa uo o�reo
_CAJ'5- 2An,vo5 OECY9 07
P
o
°
o
U
a
a
a
H
SANITARY SEWER NOTES AND SPECIFICATIONS-
PQ
A
1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE
rC"'t
STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON AND THE
LATEST EDITION OF THE WSDOT /APWA STANDARDS AND
Q
d
SPECIFICATIONS.
W
2. THE HOURS OF WORK IN THE STREET RIGHT OF WAY SHALL BE
LIMITED TO 8:30 AM TO 3:30 PM ON WEEKDAYS UNLESS OTHERWISE
W
F
O
APPROVED IN WRITING BY THE TRANSPORTATION DIVISION AT (425) 430 -
7200. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE
Z
APPROVED BY THE TRANSPORTATION DIVISION 24 HOURS IN ADVANCE.
I
THE POLICE DEPARTMENT, FIRE DEPARTMENT AND 911 SHALL BE
NOTIFIED 24 HOURS IN ADVANCE.
W
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH "STANDARD
SPECIFICATIONS FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION"
w
PREPARED BY WASHINGTON STATE CHAPTER AMERICAN PUBLIC WORKS
W
ASSOCIATION, LATEST EDITION (APWA) AND THE CITY OF RENTON
y,
STANDARD SPECIFICATIONS.
y
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
Z
Z
AND IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY THE
TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
O
DISTURBANCE.
5. A PRE - CONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL
BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION, IT SHALL BE
THE CONTRACTORS RESPONSIBILITY TO SECURE ALL NECESSARY
PERMITS PRIOR TO STARTING CONSTRUCTION (INSPECTION WILL BE
ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT
SHALL BE THE CONTRACTORS RESPONSIBILITY TO NOTIFY THE CITY
�y [-
INSPECTOR 24 HOURS IN ADVANCE OF BACKFILLING ALL
Q4
CONSTRUCTION.
o
W ^
n
N
6. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS
N
Z o
AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS
tV u c
N
N o
AND OTHERS ON THE CONSTRUCTION SITE.
wN
4
7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
S, v
p
rya
OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY
CONSTRUCTION.
z
o� vWi
m�' M
8. PLANS APPROVED BY THE CITY OF RENTON, DEVELOPMENT
SERVICES DIVISION, SHALL TAKE PRECEDENCE OVER ALL OTHER
e
PLANS.
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE
WHENEVER CONSTRUCTION IS IN PROGRESS.
t
€
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN
AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM WHICH. HAS BEEN
o
STAMPED AND SIGNED BY A LICENSED PROFESSIONAL ENGINEER OR
LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE
PIPE IN LAYERS WITH A LOOSE AVERAGE DEPTH OF 6 INCHES,
MAXIMUM DEPTH OF 8 INCHES, THOROUGHLY TAMPING EACH LAYER TO
°
95% OF MAXIMUM DENSITY. THESE COMPACTED LAYERS MUST EXTEND
II
FOR ONE PIPE DIAMETER ON EACH SIDE OF THE PIPE OR TO THE
`o
SIDE OF THE TRENCH. MATERIALS TO COMPLETE THE FILL OVER .PIPE
SHALL BE THE SAME AS DESCRIBED.
12.OPEN CUT ROAD CROSSINGS FOR UTILITY TRENCHES ON EXISTING
i
TRAVELED ROADWAY SHALL BE BACKFILLED WITH CRUSHED
z -
MECHANICALLY COMPACTED. CUTS INTO THE EXISTING ASPHALT SHALL
BE N ATUNE CUT WITH SAW IN A CONTINUOUS LINE. A TEMPORARY
_
>
MIX PATCH MUST BE PLACED IMMEDIATELY AFTER BACKFILL AND
w o
o c
COMPACTION. -A PERMANENT HOT MIX PATCH SHALL BE PLACED: WITHIN
'
10 DAYS AND SHALL BE PER CITY OF RENTON .CURRENT STANDARDS.
B
LEFT BLANK INTENTIONALLY
1 -1,
3/4" SQUARES SPACED - 3/4"
AS INDICATED - HT. 1/8"
RAISE-1/2"
VIDE BORDER
CAST IRON RING AND COVER
12"0
FIBER
PACKIr
45• (1/8)
PIPE MATERIAL AS SPECIFIED
BY THE ENGINEER
NOTE:
IN UNIMPROVED AREAS POUR 1' -0" THICK
2'-0" SQUARE CONCRETE, CLASS 3000, PAD AROUND
RING AND COVER.
IN ASPHALT ROADWAYS RESTORE AROUND CLEANOUT RING
AND COVER AS REQUIRED BY STANDARD DETAIL DRAWING BR36.
10/17/96 1 Added notes. DCV AG
DATE I REVISION I BY APPR'C
w
z
J
H
w
w
rn
Y
w
0_
0
PLUG TO BE SEALED
IN SAME MANNER AS
MAIN SEWER JOINTS.
CONCRETE
CLASS 3000
3/4„
6 INCH OR 8 INCH CLEAN -OUT
CITY OF RENTON
♦ i
STANDARD .PLANS
iST DATE: 12/96
DWG. NAME: BW18B SP PAGE: B076
o PROPERTY LINE
z
6' -0"
o FUTURE
6" BUILDING SEWER PIPE I BUILDING SEWER
5 a 13.DATUM SHALL BE CITY OF RENTON. U.S.C. AND G.S.
14.ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR 60" ALLOWABLE MAX: TEE WITH 6" SIDE OUTLET
3 3 3 a OTHERWISE STABILIZED TO THE SATISFACTION OF THE DEPARTMENT FOR CAST:. IRON PIPE
0 o p a FOR THE PREVENTION OF ONSITE EROSION AFTER THE COMPLETION OF OR DUCTILE IRON PIPE. - 2 "x 4" STUD SERVICE MARKER PAINT UPPER
CONSTRUCTION. PORTION WHITE ANS STENCIL ON SIDE
0 0 o w 1:3:.5 MIX p`'� _ _ WORDING "SEWER "` WITH 3" HIGH BLACK' LETTERS.
I I 15.ALL PIPE AND. APPURTENANCES SHALL BE. LAID ON A PROPERLY CONCRETE }' AND #6 WIRE WRAPPED AROUND THE STUD AND
° o PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(l) OF BLOCKING �. �P 2`' o v� EXTENDED TO 11iE TOP OF THE STUD.
THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR \� 1 NG
v v v > ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY R G�-� LOC�
0
00 m STATE OF WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND Nth 9
BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING + 6" SIDE OUTLET TEE MG NGR� 2% MIN SLOPE
OF THE - TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL SEWER MAIN
AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING 6'� MIN. HORIZONTAL -
MATERIAL TO UNIFORM GARDE SO THAT THE ENTIRE LENGTH OF THE / UNLESS OTHERWISE APPROVED BY THE CITY, MAKE TAP THROUGH CAST
In a PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. CONCRETE BLOCKING ANGLE IRON SADDLE SECURED TO SEWER MAIN WITH STAINLESS STEEL BANDS`
zW W PIPE BEDDING SHALL BE PEA GRAVEL 6" ABOVE AND BELOW THE OF IEE AT MAIN OVER 25 SEWER MAIN WHEN CONNECTING NEW SIDE SEWERS TO EXISTING MAIN.
W PIPE. ELEVATION -
VITRIFIED -CLAY, PLAIN AND REINFORCED CONCRETE, -D1 PL E' AND C1
�
16.SANITARY SEWER PIPE SHALL BE POLYVINYL CHLORIDE (PVC)
TYPICAL SIDE SEWER ELEVATION PIPE SEWER MAINS ARE TO BE CORE DRILLED
w
w w RUBBER GASKETED ASTM 3034, SDR 35, OR DUCTILE IRON CLASS 50. NOTE
of 0 17.IN UNIMPROVED AREAS, MANHOLE TO EXTEND MINIMUM 6 .INCHES.
UNLESS OTHERWISE. SHOWN ON PLAN, SIDE SEWER SHALL HAVE A MINIMUM 2.5' COVER AT PROPERTY
`0 T AND MAXIMUM 18 INCH ABOVE FINISHED GRADE. IN PAVED AREA, LINE OR 3-5' LOWER THAN THE LOWEST HOUSE ELEVATION,' WHICHEVER IS LOWER.
N 2 -� COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING. PN \D W Cq
v °z v~ NOTE: AVOID CUTTING UNDERGROUND RECOMMENDED �. pF wasyisF`
o N UMUTY ONES Irs COSTLYI FOR' PROVAL
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
a a a IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE THE Call EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER— BY
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO s 284
w w w REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN before YOU Bl' 'nF 'vF�I57 EWE'J,�F4,
Of X Of Of
NOT
ESHOWN ENGINEER
S NOT SHOWN INETHEIRSPROPER FOR OCATION. IN BY ss /�NAL••EN�'`
n
CALL BEFORE YOU DIG: 1- 800 - 424 -5555 �0— iOG...
UNDERGROUND SERVICE (USA). EXPIRES 5 -13 -07
n C5
srtuv iwT vam uecss swa uo o�reo
_CAJ'5- 2An,vo5 OECY9 07
P