Loading...
HomeMy WebLinkAboutD-314604d' M N D- 's d { w EX CB I - EX CB RIM EL= 96.9 RIM EL =396.9 S 12 "IE= 93.65 EX 12 "PVC N 12 "IE= 93.56 N 12 °IE= 395.75 IE «394 12 "DI _ .._. EX. ROCKERY WALL U) 0' 10' WOOD RAIL FENCE -� u 4" PVC Drain ate_ X IX I SCALE: 1 10' From Rockery 00 � l,n °� SSMH 24" IE =392.5 w z IW ! RIM EL= 397.65 - -- p IN IE= 389.12 Y UT IE =389.02 INSTALL NEW CS TYPE II I'�Y REBUILD SLOPE, SEE DETAIL -- 1"1" I'. - r rrr ° Removed, Reinstalled Ir Sign, Fence. rr WOOD RAIL Relocd Plants rC" STOP , 1 N =ENCE APEX TOP Y"r 0 .TEL BO OF SLOPE CATV _ 8 "PVC SS — EX 8 "PVC SS__- -__ -- - ___ -. u b OGV 41 = i r ° `X FIBER,OPT� rG Fl� px 1 GV I EX FIB OPTIC IOC APPX 4 _ i \ New ° POWER POLE _4_ – 12" Valve — — EX 12 "CI WM EX 12 "CI WM LJ Deadman Block Deodman Block PARKING LANE SIN ckled to Temp BND P, AJ, p Cap CUT _Z 1 Shackled to Valve -- ! — – EX 6" GAS - �X 6" GAS 1 — — Relocated Service Line T REMOVE EX 24" CMP SO Relocated 12" WM above new 24" SO --a- TRAFFIC LANE UNION AVE NE INSTALL NEW 24" SO with 45' ELs, Megalug fittings EX 24 "CMP SID EX 24 "CMP SO TRAFFIC LANE --- 0- EX SDMH o RIM EL =399.1 EX 36" WM PARKING LANE EOP }---------------° R W z CALL 48 HOURS BEFORE YOU DIG 1 -800- 424 -5555 EXISTING UTILITY LOCATIONS ARE APPROXIMATE, NOT ALL UTILTIES MAY BE SHOWN. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES. GENERAL NOTES: A. THIS PLAN DEVELOPED FROM PLANS AND ELEVATIONS IN CITY FILES. NOT SURVEYED. LOCATIONS MAY VARY. REF: TED -40 -2956 THE VINEYARDS SUBDIVISION TED -40 -1600 UNION AVE PLANS B. CONTRACTOR SHALL INSTALL EROSION CONTROL, INCLUDING FILTER FABRIC PROTECTION FOR DOWNSTREAM CATCHBASINS. C. TRENCH PATCH SHALL BE PER CITY STD PLAN 110 TYPICAL TRANSVERSE PATCH FOR FLEXIBLE PAVEMENT. D. SEE TRAFFIC CONTROL BID ITEM FOR WORK HOURS AND CONDITIONS. CONSTRUCTION NOTES: 1r REMOVE EX SO PIPE, ENLARGE OPENING AS NEEDED FOR NEW PIPE. 2O POTHOLE TO IDENTIFY UTILITY DEPTH, POTENTIAL CONFLICTS. r3 RESTORE CURB, GUTTER, SIDEWALK PER CITY DETAIL DRAWINGS, ADJUST SIDEWALK AND TYPE 2A RAMP AS NEEDED TO MATCH EXISTING. ® TESC PROTECTION: CATCH BASIN PROTECTION, FILTER FABRIC FENCING, ETC. SEE STD DETAILS 214, 216.2, 216.3. INSTALL FILTER FABRIC FENCE IN FRONT OF CONSTRUCTION AREA. PUMP WATER AROUND FILTER FABRIC AND CULVERT AS NEEDED. O PROVIDE TEMP STORM WATER BYPASS FOR EX 24" PIPE DURING CONSTRUCTION. PROFILE ALONG NEW PIPE LINE SCALE HORIZ: 1"= 10' \ /ART• 1 "- G' 12" WM RELOCATION (TYPICAL) (NTS> RECOMMENDED FOR APPROVAL By DANIEL CAREY 6/29/10 BY New Corp Stop Water Service to Residence on West Side of Union Ave 2" GAS Line Relocated 12" W I n 711� 0 New 24" SO CONIC DEADMAN NEW 12 "VALVE 45 ELs SHACKLED TO DEADMAN With Megalugs 45 ELs With Megalugs PGS IM /< hti of WAS "'� AS -BUILT SURVEY BY: D 314604 Michael R Dewitt PLS #36795 ORIGINAL PLAN STAMPED AND SIGNED 6/30/10 BY: RONALD J. STRAKA PE# 29727 EXPIRES 10/16/11 —BUILT INFO, ADDED 12'W RELOCATION DWC 112/8/101 DWC I sumavm: sc OLD INFO, OLD CONSTR. NOTES, CLEANED UP DUJNG. I As Noted __ onAwFl: DWC CNECI( @. aI SGIE RJS, DWC AT NLL it xm ox[ ixcx NO. REVISION BY DATE APPR ^aP""m'm sc.� ncmxwxciv RJS Redline Plans Stamped on 10/5/2010 }= CITY OF .0 R EN TON UNION AVE NE / NE 5th CT STORM SYSTEM REPAIR Planning /Building /Public Works Dept. 12" W RELOCATION a,:10- 7314604 =1 3 1 10-21-10 FlEIDBMN: vwc M