Loading...
HomeMy WebLinkAboutD-314605N i r M I C\ N CL .1� 3/4" DIA. SMOOTH BARS WITH ENDS WELDED TO BAR FRAME T EF I PLAN VIEW PIPE COUPLING OR JOINT (CPEP) NOTES: 1. CMP end— section (or CPEP smooth wall interior) 2. All steel parts must be galvanized and asphalt coated (Treatment 1 or better). 2 "X5" ANCHOR STRIPS WELDED TO 3/4" DIA. BAR —FRAME (4 PLACES) SPACED UNIFORMLY, FASTEN WITH 1/2" GALV. OR NON— CORROSIVE BOLTS & NUTS. t' MIN 3/4" DIA. 4" O.C. BAR BAR —FRAME SPACING T ° 0 1 r I_ 3 " BEVELED PIPE END SECTION ( —5" FOR 18" DIA. END VIEW 5 " -8" FOR 24" DIA. SIDE VIEW 7"-9" FOR 30" DIA. AND GREATER DEBRIS BARRIER — BASED ON STD PLAN 223.10 2" HMA CLASS 1/2" OR ACE CLASS B HMA OR ACP CLASS B SEE BELOW FOR MINIMUM STANDARDS* 6.5' MIN. 1' 1' 2.5' 1 T MIN MIN r MIN MIN 2" GRIND OR SAWCUT AND REMOVE, SEAL WITH AR -4000W 6" CRUSHED SURFACING TOP COURSE COMPACT TO 95% MODIFIED PROCTOR *MINIMUM STANDARDS SHALL BE: PRINCIPAL /MINOR /COLLECTOR, ARTERIAL AND INDUSTRIAL ACCESS STREETS — 6" HMA OR ACP CLASS 'B' RESIDENTIAL ACCESS STREETS — 2" HMA OR ACP CLASS 'B' THICKNESS SHALL NOT BE LESS THAN EXISTING PAVEMENT SECTION TYPICAL TRANSVERSE FLEXIBLE PAVEMENT BACKFILL MATERIAL CRUSHED SURFACE TOP COURSE, OR AS REQUIRED BY ENGINEER, COMPACT TO 95% MOD. PROCTOR PIPE ZONE BEDDING PER WSDOT STANDARD SPECIFICATIONS FOR TYPE OF PIPE, OR AS REQUIRED BY ENGINEER PATCH FOR BASED ON STD PLAN 110 (NTS) RECOMMENDED FOR APPROVAL BY DANIEL CAREY 6/29/10 BY CATCH BASIN TYPE II, 48" BASE SECTION OVERFLOW GRATE per STD. PLAN 234.30 OR EQUIVALENT REVIEW CB LOCATION WITH CITY BEFORE PLACING. ADJUST LOCATION AS NEEDED TO FIT EX. SLOPE. O 395.80 - -> DEBRIS BARRIER — II CPEP END SECTION, SEE DETAIL MATCH EX. CULVERT IE APPX -3+2.Cr —� 392.5 REBUILD DISTURBED SLOPE 2H:1V (MIN) TAPER TO BLEND INTO EXISTING SLOPE SURFACE WITH 6 TO 8 INCHES OF QUARRY SPALLS O < -- 392.35 12 "MIN. PIPE ZONE MATERIAL PER TRENCH BEDDING DETAIL �_� -- QUARRY SPALL FOUNDATION, IF NEEDED CULVERT END AND CB GRATE NEW 24 "CPEP TOP OF SLOPE — EL 398 IF APPX 3 9x2- 5-392.30 (0.10' LOWER THAN CULVERT IE) .......�PC..IM 14, aF WAey yc s 0 q RfGISTERF'��2 sDmrED: scue , N 1 ADDED AS —BUILT INFO, DWC 12/8/10 DWC Havaol�urw Nn ±s'eDiaa, AL REMOVED OLD INFO, OLD CONSTR. NOTES, CLEANED UP DRAVI NG. MON. As Noted ORIGINAL PLAN STAMPED DWC Daw: AND SIGNED 6/30/10 DWC oNE ,NCH DATUM BY: RONALD J. STRAKA a.—ECM: nr Fva Sca>: PE/% 29727 RJS, DWC IF NOT ONE INCH EXPIRES 10/16/11 NO. REVISION BY DATE APPR PPE JS scuE aCCDNCH., D=3 14605 Michael SURVEY BY: AS -BUILT Michael R. Dewitt, PLS #36795, Redline Plans Stamped on 10/5/2010 CITY OF RENTON Planning /Building /Public Works Dept. (2&: DR ,?f 05 NE 5 th G T UNION AVE NE STORM SYSTEM REPAIR DETAILS DI- 10 -21 -10 F..W Z D... NO 5 SHM. OF. - 5 246