HomeMy WebLinkAboutD-342637J 8" DIA PVC SAN SEWER 48" DIA CPEP SO IE 15.46' 14" STEEL CASING 8" PVC IE 14.51' ENCASE 13 LF 8" DIA PVC SAN SEWER IN 14" DIA STEEL CASING, SEE / SSMH #1 48" DIA MANHOLE 14" STEEL CASING 8" PVC IE 14.55' 48" DIA`CPEP SD IE 15.46' TYPE 2 CATCH BASIN, 84" DIA CASING DETAIL, THIS 8" DIA PVC SAN SEWER SHEET. CORE DRILL AND CONNECT TO EXISTING MANHOLE. RECHANNEL MANHOLE. Z -1 - ----------------- FI 18" SS - - -\ - - _--- - - - - -- - -� ✓ij - -- MH2383, 48" DIA PLAN INSTALL ADJUSTMENT RINGS AS NECESSARY, 4" MIN., 16" MAX. HEIGHT II II II �I II II IE 15.46' STANDARD SOLID LOCKING RING AND COVER RIM EL 23.9' FILL CB SUMP TO --- R'�- -A� bcu�u IE OF 48" PIPE PCLFsY WITH CONCRETE �/ PROFILE SEE SHEET SD08 FOR TRENCH BACKFILL DETAILS C13 #1 DETAIL SCALE: 1"=4' ROSEWATER CLIENTS I PEOPLEI PERFORMANCE 120i -BIRD AVENUE. SCUP ISCO SEARiI.E, WASRINGTON "101 - 3033 WITH 14 " STEEL CASING v�r�l 14" STEEL CASING 8" PVC IF 17.30' %- -SSMH #3, 48" MANHOLE �I +I TYPE 2 CATCH BASIN 84" DIA � J) `- 12" DIA CPEP SD EX 10 W 0 39.5' TO CROWN ��I FF ------ �i CB #4A- �u11 22" X 26" CONC INLET 14" STEEL CASING 48" CPEP SD 8" PVC IF 16.48' 1 1 N% IE = 16.33' - -I I if % I\ 18" SS R - - -- Ttt- ------------ - - - - -� (� L MH2181 PLAN 54" MANHOLE ENCASE 12 LF 8" DIA PVC SAN SEWER IN 14" DIA STEEL CASING. SEE CASING DETAIL, THIS SHEET. INSTALL ADJUSTMENT RINGS AS NECESSARY, 4" MIN., 16" MAX. HEIGHT T. 0. S. EX 10" WATER f 39" TO CROWNC) II II I� STANDARD SOLID LOCKING RING AND COVER IE 12" 21.77' II i IE 17.7' 8 "PVC WITH 14" STEEL CASING II � PROFILE SEE SHEET SD08� FOR TRENCH BACKFILL DETAILS C13 #4 DETAIL SCALE: 1"=4' 1. LOCATE CATCH BASIN SUCH THAT KNOCKOUT FOR STEEL CASING SEPARATED FROM 48" DIA. CONCRETE PIPE KNOCKOUT BY 1' HORIZONTAL, MINIMUM (AS MEASURED ON INSIDE WALL OF STRUCTURE). CATCH BASIN TO HAVE KNOCKOUT PROVIDED PRIOR TO DELIVERY TO PROJECT SITE. 2. STEEL CASING SHALL EXTEND 2 FT. BEYOND BOTH SIDES OF OUTSIDE SURFACE OF CATCH BASIN. 3. PROPOSED PVC CARRIER PIPES SHALL EACH BE OUTFITTED WITH CALPICO MODEL M SPACERS OR APPROVED EQUAL. SEE CASING INSTALLATION DETAIL ON THIS SHEET. 4. CARRIER PIPE SHALL HAVE RESTRAINED JOINTS WITHIN ENCASEMENT PIPE. 5. CATCH BASINS SHALL BE EQUIPPED WITH LADDER RUNGS PER THE SPECIFICATIONS (NOT SHOWN ON PROFILE FOR CLARITY). 6. SEE SPECIFICATIONS FOR ADDITIONAL DESIGN AND CONSTRUCTION REQUIREMENTS. PLACE END SPACER MAXIMUM OF ONE (1) FOOT FROM END OF CASING (TYP.) -STEEL PIPE CASING MAXIMUM DISTANCE BETWEEN SPACERS _ SHALL BE SIX (6) FEET O.C. I 12" �- CASING SPACERS SHALL BE MAXIMUM OF ONE (1) FOOT FROM EACH SIDE OF PIPE JOINT SEAL END OF CASING WITH NEOPRENE CASING END SEALS (CASCADE END SEALS OR APPROVED EQUAL) CARRIER PIPE (PVC, SDR 35) CASING SPACERS CARRIER PIPE DIAMETER 6" II it 12" ! L,,- IL1 SSMH #1 48" DIA MANHOLE 14" STEEL CASING 8" PVC IE 14.55' 48" DIA`CPEP SD IE 15.46' TYPE 2 CATCH BASIN, 84" DIA CASING DETAIL, THIS 8" DIA PVC SAN SEWER SHEET. CORE DRILL AND CONNECT TO EXISTING MANHOLE. RECHANNEL MANHOLE. Z -1 - ----------------- FI 18" SS - - -\ - - _--- - - - - -- - -� ✓ij - -- MH2383, 48" DIA PLAN INSTALL ADJUSTMENT RINGS AS NECESSARY, 4" MIN., 16" MAX. HEIGHT II II II �I II II IE 15.46' STANDARD SOLID LOCKING RING AND COVER RIM EL 23.9' FILL CB SUMP TO --- R'�- -A� bcu�u IE OF 48" PIPE PCLFsY WITH CONCRETE �/ PROFILE SEE SHEET SD08 FOR TRENCH BACKFILL DETAILS C13 #1 DETAIL SCALE: 1"=4' ROSEWATER CLIENTS I PEOPLEI PERFORMANCE 120i -BIRD AVENUE. SCUP ISCO SEARiI.E, WASRINGTON "101 - 3033 WITH 14 " STEEL CASING v�r�l 14" STEEL CASING 8" PVC IF 17.30' %- -SSMH #3, 48" MANHOLE �I +I TYPE 2 CATCH BASIN 84" DIA � J) `- 12" DIA CPEP SD EX 10 W 0 39.5' TO CROWN ��I FF ------ �i CB #4A- �u11 22" X 26" CONC INLET 14" STEEL CASING 48" CPEP SD 8" PVC IF 16.48' 1 1 N% IE = 16.33' - -I I if % I\ 18" SS R - - -- Ttt- ------------ - - - - -� (� L MH2181 PLAN 54" MANHOLE ENCASE 12 LF 8" DIA PVC SAN SEWER IN 14" DIA STEEL CASING. SEE CASING DETAIL, THIS SHEET. INSTALL ADJUSTMENT RINGS AS NECESSARY, 4" MIN., 16" MAX. HEIGHT T. 0. S. EX 10" WATER f 39" TO CROWNC) II II I� STANDARD SOLID LOCKING RING AND COVER IE 12" 21.77' II i IE 17.7' 8 "PVC WITH 14" STEEL CASING II � PROFILE SEE SHEET SD08� FOR TRENCH BACKFILL DETAILS C13 #4 DETAIL SCALE: 1"=4' 1. LOCATE CATCH BASIN SUCH THAT KNOCKOUT FOR STEEL CASING SEPARATED FROM 48" DIA. CONCRETE PIPE KNOCKOUT BY 1' HORIZONTAL, MINIMUM (AS MEASURED ON INSIDE WALL OF STRUCTURE). CATCH BASIN TO HAVE KNOCKOUT PROVIDED PRIOR TO DELIVERY TO PROJECT SITE. 2. STEEL CASING SHALL EXTEND 2 FT. BEYOND BOTH SIDES OF OUTSIDE SURFACE OF CATCH BASIN. 3. PROPOSED PVC CARRIER PIPES SHALL EACH BE OUTFITTED WITH CALPICO MODEL M SPACERS OR APPROVED EQUAL. SEE CASING INSTALLATION DETAIL ON THIS SHEET. 4. CARRIER PIPE SHALL HAVE RESTRAINED JOINTS WITHIN ENCASEMENT PIPE. 5. CATCH BASINS SHALL BE EQUIPPED WITH LADDER RUNGS PER THE SPECIFICATIONS (NOT SHOWN ON PROFILE FOR CLARITY). 6. SEE SPECIFICATIONS FOR ADDITIONAL DESIGN AND CONSTRUCTION REQUIREMENTS. PLACE END SPACER MAXIMUM OF ONE (1) FOOT FROM END OF CASING (TYP.) -STEEL PIPE CASING MAXIMUM DISTANCE BETWEEN SPACERS _ SHALL BE SIX (6) FEET O.C. I 12" �- CASING SPACERS SHALL BE MAXIMUM OF ONE (1) FOOT FROM EACH SIDE OF PIPE JOINT SEAL END OF CASING WITH NEOPRENE CASING END SEALS (CASCADE END SEALS OR APPROVED EQUAL) CARRIER PIPE (PVC, SDR 35) CASING SPACERS CARRIER PIPE DIAMETER 6" 8" CASING DIAMETER 12" ! 14" MIN. CASING THICKNESS 0.25" 0.25' SPACER BAND WIDTH 8" 8" ANTICORROSION COATING THICKNESS: CASING - 12 MILS DFT NOTES: 1. CASING SPACERS SHALL BE "CENTER POSITIONING" TYPE. MINIMUM RUNNER WIDTH SHALL BE 2 INCHES. 2. RUNNER HEIGHT SHALL BE SIZED TO PROVIDE: A. MINIMUM 0.75" BETWEEN CARRIER PIPE BELL AND CASING PIPE WALL AT ALL TIMES. B. MINIMUM 1" CLEARANCE BETWEEN RUNNERS AND TOP OF CASING WALL TO PREVENT JAMMING 'DURING INSTALLATION. SEWER CASING DETAIL NITS D- 342631 __..._.__. tiAIIVItF: AVt J kZjM 1l 1 R S VER "GAL: vE, 1 ,3 /1 IMPROVEMENTS PROJECT DM)M HARRIS I AECOM 1 APPROVED FOR CONSTRUCTION .ti � Q�� Wqs� �� DESIGNED. VARIES „ORIZONTPL: NAD 1983/1991 fIfL0800H: �, KSMITH �' ,� CITY OF PHASE 1 PAGE: DRAWN RENTON 10900 NE 8TH STREET, SUITE 750 1� DATUM =� SHATTUCK AVE S STORMWATER BYPASS oRAwNG N0: BELLEVUE, WASHINGTON 98004 %N ` R. EDRALIN PHONE: (425) 454 -5600 FAX: (425) 454 -0220 °� aaeoe �� CITY OF RENTON DATE CHECKED: ONE NCH E Public Works Dept. STORM DRAINAGE & UTILITIES S'D06 OF '�s1>� �� M DE LILLA ^ „Or ONE�O„ DETAILS "� L\ °G\ APPROVED: ACCORDINGLY MEET: 77 OF4j _ ONAL '! FED AID NO.: ARRA- 0167(044) NO. REVISION BY DATE JAPPR K. SMITH C� 'h- 34�L57 D- I 2 7 3 4 2 E