mI SA NITA R Y SEWER NOTES
ail
Z
0
i
N
m
W
o
w
w
a
cc
a�
C4
0
C2
ail
cr
W W
1. ALL *VRK MA 7FR/ALS SHALL BE IN CONFORMANCE IMTH THE STANDARDS AND SPECIF /CA VANS OF THE CITY OF RENTON
U7TLI TY DEPARTMENT AND THE LA TEST EDV T70H1 OF THE WSDOT/APWA STANDARDS AND SP£C/f7'CA 770OVS
2. THE HOURS OF WORK IN THE STREET RIGHT -OF- WA Y SHALL BE LIMI TEED TO & 30 AM TO 3: 30 PM AN WEKDA Y5 UNLESS
OTHERWISE APPROVED IN NCR17 NG BY THE DEPARTMENT OF PUBLIC *VRKS A T 425-4.50-7200. ALL STREET CLOSURES,
PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OIF PUBLIC MAWS 24 HOURS IN ADVANCE. THE POLICE
DEPARTMENT FIRE DEPAR7MENT, AND 911 SHALL BE NOTTf7ED 24 HOURS IN ADVANCE.
J. A LL CONS TRUC7701V SHALL BE IN ACCORDANCE WITH "STANDARD SPECIRCA 77ONS FAR MUNICIPAL PUBLIC WnRKS
CONSTRUCTTOW" PREPARED BY THE WASHINGTON STA TLS CHAPTER AMERICAN PUBLIC WIDRKS ASSOC/A 77AN (APWA), LA TEST
ED17700V AND THE CITY of RENTOW STANDARD SPECIf7CA 770WS.
4. ALL LOCH 77ONS OF EXIS77NG UTILITIES SHOWN ARE APPRDX /MA TF AND IT SHALL BE THE CONTRACTORS'
RESPONSIBILITY 70 VERIFY 7HE TRUE AND CORRECT LOCH 770VV SO AS TO A VVID DAMAGE OR DIS7URBANCE.
5. A PRE- CONSTRUC710NV CONFERENCE AND A 24 HOUR N077CE SHALL BE REQUIRED PRIOR TO STAR77NG NEW CONS7RUC770N.
IT SHALL BE THE CON7RA CTOR'S RESPONS(BILI TY TO SECURE ALL NECESSARY PERM /TS PR /OR TO STAR77NG
CONS 7RUC 770N. (INSPEC77CW WILL BE ACCOMPLISHED BY A REPRESENTA 77 k OF THE Cl TY OF RENTON). I T SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO NO77FY THE U77LITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL
CONSTRUCTION
6. CONTRACTOR IS SaEL Y RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONS7RUCTTON AND FOR THE SAFETY
OF WORKERS AND OTHERS ON THE CONS7RUC770N SI7F
7. IT SHALL BE THE RESPONSIBILITY OF 7HE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELA OFD PERMITS
PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY ME CITY OF REN70N PUBLIC Wt7RKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
9. A COPY OF 7HESE APPROVED PLANS MUST BE ON THE JOB SI7F WENEVER CONSMUCTTON IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WfTH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM
WHICH HAS BEEN STAMPED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALL Y ON 80TH SIDES OF ONE PIPE IN LA )FRS W1'T Y A LOOSE A VERAGE DEPTH OF 6
INCHES, MAXIMUM DEP TY OF 8 INCHES, THOROUGHL Y TAMPING EA CH LA YER TO 95X OF MAX /MUM DENSI T7! THESE
COMPACMD LA YERS MUST EXTE'NO FOR ONE PIPE DIAMETER ON EACH S /DE OF THE PIPE OR TO 7HE SIDE OF THE
TRENCH. MATERIALS TO COMPLE7F THE FILL OVER THE PIPE SHALL BE ONE SAME AS DESCRIBED.
12 OPEN CUT ROAD CROSSINGS FOR UMITY TRENCHES ON EXISTING IRA VErLED ROADWA Y SHALL BE BACKFILLED WITH
CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO EXIS77NG ASPHALT SHALL BE NEA 7LINE CUT Wf TH A SAW IN
A CON77N000S LINE. A 7EMPORARY COLD MIX PA TCH MUST BE PLACED /MMED /A 7FL Y AFTER BACKFILL AND COMPAC77ON.
A PERMANENT HOT MIX PA TCH SHALL BE PLACED WI THIN 10 DA YS AND SHALL BE PER CURRENT CI TY OF- RENTON
STANDARDS.
13 DA 7UM SHALL BE CITY OF RENTON, NAM 1988 (METERS) AND NAD 1983/1991 (METERS)
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SA 77SFA C770YV OF THE
DEPARTMENT FOR ONE PREPEN77ON OF ON -SITE EROSION AFTER THE COUPLEI7ON OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDA 770N IN ACCORDANCE WITH SEC77ON
7- 02.3(1) OF THE CURRENT STA 7E OF WASH /NGTON STANDARD SPECIFICA 77ONS FOR ROAD ANO BRIDGE CONS 7RUC770N.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF 7HE FOUNDA 7700V MA TER /AL AS *ELL
AS PLACEMENT AND COMPAC77ON OF REQUIRED BEDDING MA 71`RIAL TO UNIFORM GRADE SO 1HA T THE EN77RE LENGTH OF
PIPE WE'LL BE SUPPOR7ED ON A UNIFORYL Y DENSE UN"ELO /NG BASE. PIPE BEDDING SHALL BE PEA GRA V£L 6" ABOPF
AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POL YVINYL CHLORIDE (PVC) RUBBER GASKE7ErD ASTN D 3034, SDR 35 OR DUCTILE
IRON CLASS 50. SANITARY SEWER FORCE MAIN TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO LA 7FST
REVISION OF A WWA C110 & C111, THICKNESS CL. 52.
17 IN UNIMPROVED AREAS, MANHOLE TO EX7FND A MIN /MUM OF 6" AND A MAX /MUM OF 18" ABOVE FIN /SHED GRADE. /N
PA VED AREAS, COVER MUST SLOPE IN ALL DIREC77ONVS TO MA TCH PA V!NGG,
18. ALL SANITARY SEWER IMPROVEMENTS SHALL BE CON57RUC7F'D IN ACCORDANCE WITH THESE APPROVED PLANS. ANY
DEEWA 770W FROM/ 7HESE PLANS WILL REQUIRE APPROVAL FROU THE OWNER, ENGINEER AND APPROIARIA T F PUBLIC
AGENCIES.
19. LOCA 77ONS OF ROADWA YS, BUILDINGS AND PARKING AREAS SHOWN HEREON ARE APPRDX /MA 7E. FOR DIMENSIONED
LOCA 77ONS OF THESE IMPROVEMENTS, REFER TO THE ARCH /TFCTURAL SI7E PLAN. IMPROVEMENT AND S7RUC711RE
LOCH 77ONS SHALL BE FIELD SET BY THE ENGINEER AS REQUIRED.
20. ALL MANHOLES SHALL BE PER THE CITY OF RENTON STANDARDS AND SPECIRCA 7TONSS, ALL MANHOLES SHALL HA VF A
M/N/MUM a 1D FOOT TO MAXIMUM 1.0 FOOT DROP BETWEN INVFRT IN ANO INVERT OUT. ALL MANHOILE COWRS SHALL
BE ADXS7ED TO FINISH GRADE PR/AR TO FINAL PA WNG OR LANDSCAPING.
21. ALL 7RENCH BACKFILL SHALL BE COMPACTED TO A T LEAST 95x OF ONE MAX /MUM DRY DENSITY PER ASTM D- 1557 -70
(MO1DIf7ED PROCTOR), FOR THE FIRST 7H EE FEET ABOVE THE PIPE. THE REMAINING BACKFILL MA Y BE TO 9OX IF
NOT IN AN AREA OF FU71JRE PA VFMENT OR S7RUC7URAL FILL. TRENCH BACKFILL AND COMPAC7TON SHALL BE COUPLETErD
PRICY? TO 7ES77NG LINES FOR LEAKAGE.
22. ALL SIDE SEWERS SHALL BE A MIN /MUM 6" D/AME7FR AND HA W A MIN /MUM SLOW£ OF 2. OX PROPER TY/L0T CORNERS
AND /OR BUILDING LOCA 77ONS AND FINISH GRADES SHALL BE ESTABLISHED IN THE FIELD PR /OR TO ANY SEWER
CONSTRUCTION. SIDE SEWER 7EE STA 770WS ARE REFERENCED FROM/ THE NEAREST DOWNSTREAM MANHLaLE. THE
CON7RACTOR SHALL MAINTA IN ACCURATE AS -BUIL T RECORDS OF ALL SIDE SEVER LOCH 770OVS. ALL SIDE SEW RS SHALL
BE 7FS7EFD A T 7HE TOME OF MAIN LINE 7E- STING.
23. WHERE A WA 7F'R MAIN CROSSES ABOVE THE SANITARY SEWER, AND LESS 7HAN 3'0" 0#r WR77CAL CLEARANCE EX/S75
BETNEEN THE TOP OF SEVER AND BOTTOM OF WA TER MAIN, ME' SEVER SHALL BE CONSTRUCTED OR RECONVSTRUCMD WITH
DUC77LE /ROW PIPE (CLASS 50) FOR A MINIMUM HORIZONTAL DISTANCE OF 10' ON EACH SIDE OF TIME WA TER MAIN
CROSSINGG,
24 SANITARY SEVER MAIN LINES (8" DIAME-TER AND LARGER) SHALL NOT BE CONSTRUCTED ANY CLOSER THAN 10 FEET TO
ANY BUILDING OR 5 FEET TO ANY CARPORT.
25. NEW CONNECTIONS TO EXIS77NG FACILITIES SHALL BE SEALED OFF UN77L UPS7REAM CONS7RUCTTON IS FINISHED,
TESTED, CLEANED AND ACCEPTED. ALL C00VS7RUC77CN DEBRIS AND WA 7LR SHALL BE REMOVED PRIOR 70 OPENING ONE
SEAL. ALL 7FS77NG SHALL BE IN ME PRESENCE OF A CITY OF RENTON INSPECTOR.
26. PRIOR TO ACCEPTANCE OF CONS7QUC770N AND /OR ISSUANCE OF OCCUPANCY PERM(M ENG/NEERISURVEYOR- CER7TF /ED
AS -BUIL T DRAIMNGS A/UST B£ PREPARED OF ALL SANITARY SEVER FAaLITIEB
MOR)AA
FILLET
s' MIN. +
T
SEC. 16, TWP, 23 We ROE. 5 E. � W.M.
8 x 8 "x 114"
SM PLAIT
4►5' &WD
NI 7H PUV
PLUG
arc PIPE aAMEMe As
N07En cw ME PLANS
(LANDSCAPE AREA aF AX sEeWCE)
CZE4NOLff DETAIL
K703 .-
CASTING INLAND fDIRY
CAP F011AL PT., f714
SEE DETAIL 51.4.
ADWSIMENT 4" MIN.
.!:La
RUB ER GASKEMD "N7S
N ACICARDANCE WTH AS7M C -443
PRECAST SEC770 V
S7FPS - 314" DIEFGi MED BAR
S7FPS SHALL sE ovaUQED
C VO?ETF ftWR BY PIPE INC,
GYP APPROVED 06AL.
MAX. PfF SIZE - 21'0 I.D.
LAGIGIER- -STD. ALUMINUM
OR GAL VAN/ZED STEEL
i%WWIF 9Vi7F
PRECAST BASE" S FC#aN
GYP CAST IN SNiZf.
SANITARYMANHOLE 7YPICAL DETAIL
FtOLL1'9�7
1
NO SCALE
B' IEE
1%1 PLUG
AS DAM
STAMI►KESS
SiM STRAPS
900 a
18" MAX.
INSIDE DROP C
IN EX. SSMH w 60 8
t Ar[ AFF 9wA[t aE s" ruTfiu[ As MAftff.
2 SrilOWL- S Sffn STRAPS Si MU HA If A AIIAXMW
PACK GIB 18'. STRAPS SVAU 8f ATTAO"
019W SrA#WrZ Sffn EJrPANSOY A2 N
AINIL 2 EAOf A r COWCnOV PgWIS
I fa? MANAW 1 AAb Z IW COVMAC7OP HAS
7W aPXW ar ALSO iSW AN OUT" GI►PIAo PER
Gadt sm 6071
FR 3�
ND1FS
1. STEPS rO BE J1410 DEFOYPA/ED BAR
GAL VAN /ZED SAFETY STEPS GYP EQUAL.
2 57EPS ARE 70 BE IN PLACE BUWE
MANHOLE SEC77LWS ARE INSTALLED.
J CASTING rO BLS` PER DRAKING BR2. 9
4 MANHGY.E WC776WS TO BE 6F REIWFGIRCED
PRECAST COV07EM
5 ALL "N75 SHALL BE MOWED.
6 SAN /TARY SEVER MANHOLES SMALL HAW
ALL aVIENOR SURFACES, MIaUDYWG '
OVANNELING COATED (SEALED) M11H A HIG Y
SOLIDS URETHANE COLA ANG' WAS'SER
MC- CaWTAL GYP APPROVED EOUAL,• COLAS'' Or
COA 77NG STIALL BE NHI M
7 RUBBER GANEW XWTS SMALL BE IN
CaVf YPII/ANCE N1TH ASIA/ C -443
8 OYANNEL HEOYT SMALL BE A MINIMUM OF
314 Of - 7HE /N,9DIE DYAMEMR OF THE LARGEST
PIPE.
9 CGWNEC7TOWS M MANHOLE 9YALL dE MADE
USWG OW ADAPMR,, K6R- -N -SEAL 801075 6R
APPROVED EQY/AL
RIV
I 10' 4#N.
6" fiMDWG SEVER APE
I
7FE WhY 6" .SLOE OI lur I GZ'EANGrIT -SEE
DETAIL LEFT
2 "x 4" SW .SERVILE MARKER PA /NT Uol°E"R
PW770V MH17F ANS S71NOL 6W SW
#DUNG "SE"NER" WTH 3" HIG Y MACK LETIFRB
AND A HIRE NIPAPP0 ARAI/WD 1HE SW AND
EX75NDED M 7HE 70P aF 7HE STUD.
SIDE SEWER DETAIL
NO SCALE
60" ALL OWAME MAX.
FOR CAST NOW PIPE
a? DUCTILE RM PIPE
ctiwcwE7E ,
MOCKING
5" SW AU11ET ME
SEVER MAIN
CMG ME7F 6LOCKNG ANGLE"
`D
OF TEL" A T MAIN OVER 25'
E�TM�G
1X ANN 5X WE
HQfl7QVTAL
` SENfR MAIN
TYPICAL SW WNUR ELEVA MW
NOTE
UNLESS OTHERNISE SHONN aN PLAN, SIDE SEVER SHALL HA Vf A ANN /MUM
4' GO7VER AT PRIA Ewy aw GYP .i 5' LONER IRAN THE LONEST HOUSE
ELEVA AGW, NflMhf ER /S LONER.
UNLESS OTHERIMSE APPIROWD Br THE aTY, MAKE TAP 7HROOW CAST
/ROV SADDLE ,SEa R1ED 70 SEVER MAIN IMTH STAINLESS STEEL BANDS
NNEN C WNECTING NEW S)E SE'NERS 70 EXISANG MAIN.
N7Td 4FIED aA Y, PLAIN AND A9NF0RffD GONO 7F D. /. PPE AAV C Z
PFF SE"NER MAINS ARE TO 6E CWE DN#LLED
SIDE SEWER DE TA Am
NO SCALE
5 -30 ?403
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
•L'��� Date
Date
Date
.oY
1a 6 -12 -05
14711 NE 2ft Ploa, # 101
N. IN 0 wasmigion 98007
425.885.7877 Fox 4 25.885.7963
'cosm ENGINEERING
DESIGN PLANNING
�zm
SURVEYING
SANITARY SEWER DETAILS & NOTES
iCANMEO MR ! t
�J
aJ121l W
?r .► .,pi. M �► y
z
0
i
N
cr
W W
1. ALL *VRK MA 7FR/ALS SHALL BE IN CONFORMANCE IMTH THE STANDARDS AND SPECIF /CA VANS OF THE CITY OF RENTON
U7TLI TY DEPARTMENT AND THE LA TEST EDV T70H1 OF THE WSDOT/APWA STANDARDS AND SP£C/f7'CA 770OVS
2. THE HOURS OF WORK IN THE STREET RIGHT -OF- WA Y SHALL BE LIMI TEED TO & 30 AM TO 3: 30 PM AN WEKDA Y5 UNLESS
OTHERWISE APPROVED IN NCR17 NG BY THE DEPARTMENT OF PUBLIC *VRKS A T 425-4.50-7200. ALL STREET CLOSURES,
PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OIF PUBLIC MAWS 24 HOURS IN ADVANCE. THE POLICE
DEPARTMENT FIRE DEPAR7MENT, AND 911 SHALL BE NOTTf7ED 24 HOURS IN ADVANCE.
J. A LL CONS TRUC7701V SHALL BE IN ACCORDANCE WITH "STANDARD SPECIRCA 77ONS FAR MUNICIPAL PUBLIC WnRKS
CONSTRUCTTOW" PREPARED BY THE WASHINGTON STA TLS CHAPTER AMERICAN PUBLIC WIDRKS ASSOC/A 77AN (APWA), LA TEST
ED17700V AND THE CITY of RENTOW STANDARD SPECIf7CA 770WS.
4. ALL LOCH 77ONS OF EXIS77NG UTILITIES SHOWN ARE APPRDX /MA TF AND IT SHALL BE THE CONTRACTORS'
RESPONSIBILITY 70 VERIFY 7HE TRUE AND CORRECT LOCH 770VV SO AS TO A VVID DAMAGE OR DIS7URBANCE.
5. A PRE- CONSTRUC710NV CONFERENCE AND A 24 HOUR N077CE SHALL BE REQUIRED PRIOR TO STAR77NG NEW CONS7RUC770N.
IT SHALL BE THE CON7RA CTOR'S RESPONS(BILI TY TO SECURE ALL NECESSARY PERM /TS PR /OR TO STAR77NG
CONS 7RUC 770N. (INSPEC77CW WILL BE ACCOMPLISHED BY A REPRESENTA 77 k OF THE Cl TY OF RENTON). I T SHALL BE
THE CONTRACTOR'S RESPONSIBILITY TO NO77FY THE U77LITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL
CONSTRUCTION
6. CONTRACTOR IS SaEL Y RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONS7RUCTTON AND FOR THE SAFETY
OF WORKERS AND OTHERS ON THE CONS7RUC770N SI7F
7. IT SHALL BE THE RESPONSIBILITY OF 7HE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELA OFD PERMITS
PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY ME CITY OF REN70N PUBLIC Wt7RKS DEPARTMENT SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS.
9. A COPY OF 7HESE APPROVED PLANS MUST BE ON THE JOB SI7F WENEVER CONSMUCTTON IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WfTH AN AS -BUILT DRAWING OF THE SANITARY SEWER SYSTEM
WHICH HAS BEEN STAMPED BY A LICENSED PROFESSIONAL ENGINEER OR LICENSED PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALL Y ON 80TH SIDES OF ONE PIPE IN LA )FRS W1'T Y A LOOSE A VERAGE DEPTH OF 6
INCHES, MAXIMUM DEP TY OF 8 INCHES, THOROUGHL Y TAMPING EA CH LA YER TO 95X OF MAX /MUM DENSI T7! THESE
COMPACMD LA YERS MUST EXTE'NO FOR ONE PIPE DIAMETER ON EACH S /DE OF THE PIPE OR TO 7HE SIDE OF THE
TRENCH. MATERIALS TO COMPLE7F THE FILL OVER THE PIPE SHALL BE ONE SAME AS DESCRIBED.
12 OPEN CUT ROAD CROSSINGS FOR UMITY TRENCHES ON EXISTING IRA VErLED ROADWA Y SHALL BE BACKFILLED WITH
CRUSHED ROCK AND MECHANICALLY COMPACTED. CUTS INTO EXIS77NG ASPHALT SHALL BE NEA 7LINE CUT Wf TH A SAW IN
A CON77N000S LINE. A 7EMPORARY COLD MIX PA TCH MUST BE PLACED /MMED /A 7FL Y AFTER BACKFILL AND COMPAC77ON.
A PERMANENT HOT MIX PA TCH SHALL BE PLACED WI THIN 10 DA YS AND SHALL BE PER CURRENT CI TY OF- RENTON
STANDARDS.
13 DA 7UM SHALL BE CITY OF RENTON, NAM 1988 (METERS) AND NAD 1983/1991 (METERS)
14. ALL DISTURBED AREAS SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED TO THE SA 77SFA C770YV OF THE
DEPARTMENT FOR ONE PREPEN77ON OF ON -SITE EROSION AFTER THE COUPLEI7ON OF CONSTRUCTION.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDA 770N IN ACCORDANCE WITH SEC77ON
7- 02.3(1) OF THE CURRENT STA 7E OF WASH /NGTON STANDARD SPECIFICA 77ONS FOR ROAD ANO BRIDGE CONS 7RUC770N.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF 7HE FOUNDA 7700V MA TER /AL AS *ELL
AS PLACEMENT AND COMPAC77ON OF REQUIRED BEDDING MA 71`RIAL TO UNIFORM GRADE SO 1HA T THE EN77RE LENGTH OF
PIPE WE'LL BE SUPPOR7ED ON A UNIFORYL Y DENSE UN"ELO /NG BASE. PIPE BEDDING SHALL BE PEA GRA V£L 6" ABOPF
AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE POL YVINYL CHLORIDE (PVC) RUBBER GASKE7ErD ASTN D 3034, SDR 35 OR DUCTILE
IRON CLASS 50. SANITARY SEWER FORCE MAIN TO BE CEMENT LINED DUCTILE IRON PIPE CONFORMING TO LA 7FST
REVISION OF A WWA C110 & C111, THICKNESS CL. 52.
17 IN UNIMPROVED AREAS, MANHOLE TO EX7FND A MIN /MUM OF 6" AND A MAX /MUM OF 18" ABOVE FIN /SHED GRADE. /N
PA VED AREAS, COVER MUST SLOPE IN ALL DIREC77ONVS TO MA TCH PA V!NGG,
18. ALL SANITARY SEWER IMPROVEMENTS SHALL BE CON57RUC7F'D IN ACCORDANCE WITH THESE APPROVED PLANS. ANY
DEEWA 770W FROM/ 7HESE PLANS WILL REQUIRE APPROVAL FROU THE OWNER, ENGINEER AND APPROIARIA T F PUBLIC
AGENCIES.
19. LOCA 77ONS OF ROADWA YS, BUILDINGS AND PARKING AREAS SHOWN HEREON ARE APPRDX /MA 7E. FOR DIMENSIONED
LOCA 77ONS OF THESE IMPROVEMENTS, REFER TO THE ARCH /TFCTURAL SI7E PLAN. IMPROVEMENT AND S7RUC711RE
LOCH 77ONS SHALL BE FIELD SET BY THE ENGINEER AS REQUIRED.
20. ALL MANHOLES SHALL BE PER THE CITY OF RENTON STANDARDS AND SPECIRCA 7TONSS, ALL MANHOLES SHALL HA VF A
M/N/MUM a 1D FOOT TO MAXIMUM 1.0 FOOT DROP BETWEN INVFRT IN ANO INVERT OUT. ALL MANHOILE COWRS SHALL
BE ADXS7ED TO FINISH GRADE PR/AR TO FINAL PA WNG OR LANDSCAPING.
21. ALL 7RENCH BACKFILL SHALL BE COMPACTED TO A T LEAST 95x OF ONE MAX /MUM DRY DENSITY PER ASTM D- 1557 -70
(MO1DIf7ED PROCTOR), FOR THE FIRST 7H EE FEET ABOVE THE PIPE. THE REMAINING BACKFILL MA Y BE TO 9OX IF
NOT IN AN AREA OF FU71JRE PA VFMENT OR S7RUC7URAL FILL. TRENCH BACKFILL AND COMPAC7TON SHALL BE COUPLETErD
PRICY? TO 7ES77NG LINES FOR LEAKAGE.
22. ALL SIDE SEWERS SHALL BE A MIN /MUM 6" D/AME7FR AND HA W A MIN /MUM SLOW£ OF 2. OX PROPER TY/L0T CORNERS
AND /OR BUILDING LOCA 77ONS AND FINISH GRADES SHALL BE ESTABLISHED IN THE FIELD PR /OR TO ANY SEWER
CONSTRUCTION. SIDE SEWER 7EE STA 770WS ARE REFERENCED FROM/ THE NEAREST DOWNSTREAM MANHLaLE. THE
CON7RACTOR SHALL MAINTA IN ACCURATE AS -BUIL T RECORDS OF ALL SIDE SEVER LOCH 770OVS. ALL SIDE SEW RS SHALL
BE 7FS7EFD A T 7HE TOME OF MAIN LINE 7E- STING.
23. WHERE A WA 7F'R MAIN CROSSES ABOVE THE SANITARY SEWER, AND LESS 7HAN 3'0" 0#r WR77CAL CLEARANCE EX/S75
BETNEEN THE TOP OF SEVER AND BOTTOM OF WA TER MAIN, ME' SEVER SHALL BE CONSTRUCTED OR RECONVSTRUCMD WITH
DUC77LE /ROW PIPE (CLASS 50) FOR A MINIMUM HORIZONTAL DISTANCE OF 10' ON EACH SIDE OF TIME WA TER MAIN
CROSSINGG,
24 SANITARY SEVER MAIN LINES (8" DIAME-TER AND LARGER) SHALL NOT BE CONSTRUCTED ANY CLOSER THAN 10 FEET TO
ANY BUILDING OR 5 FEET TO ANY CARPORT.
25. NEW CONNECTIONS TO EXIS77NG FACILITIES SHALL BE SEALED OFF UN77L UPS7REAM CONS7RUCTTON IS FINISHED,
TESTED, CLEANED AND ACCEPTED. ALL C00VS7RUC77CN DEBRIS AND WA 7LR SHALL BE REMOVED PRIOR 70 OPENING ONE
SEAL. ALL 7FS77NG SHALL BE IN ME PRESENCE OF A CITY OF RENTON INSPECTOR.
26. PRIOR TO ACCEPTANCE OF CONS7QUC770N AND /OR ISSUANCE OF OCCUPANCY PERM(M ENG/NEERISURVEYOR- CER7TF /ED
AS -BUIL T DRAIMNGS A/UST B£ PREPARED OF ALL SANITARY SEVER FAaLITIEB
MOR)AA
FILLET
s' MIN. +
T
SEC. 16, TWP, 23 We ROE. 5 E. � W.M.
8 x 8 "x 114"
SM PLAIT
4►5' &WD
NI 7H PUV
PLUG
arc PIPE aAMEMe As
N07En cw ME PLANS
(LANDSCAPE AREA aF AX sEeWCE)
CZE4NOLff DETAIL
K703 .-
CASTING INLAND fDIRY
CAP F011AL PT., f714
SEE DETAIL 51.4.
ADWSIMENT 4" MIN.
.!:La
RUB ER GASKEMD "N7S
N ACICARDANCE WTH AS7M C -443
PRECAST SEC770 V
S7FPS - 314" DIEFGi MED BAR
S7FPS SHALL sE ovaUQED
C VO?ETF ftWR BY PIPE INC,
GYP APPROVED 06AL.
MAX. PfF SIZE - 21'0 I.D.
LAGIGIER- -STD. ALUMINUM
OR GAL VAN/ZED STEEL
i%WWIF 9Vi7F
PRECAST BASE" S FC#aN
GYP CAST IN SNiZf.
SANITARYMANHOLE 7YPICAL DETAIL
FtOLL1'9�7
1
NO SCALE
B' IEE
1%1 PLUG
AS DAM
STAMI►KESS
SiM STRAPS
900 a
18" MAX.
INSIDE DROP C
IN EX. SSMH w 60 8
t Ar[ AFF 9wA[t aE s" ruTfiu[ As MAftff.
2 SrilOWL- S Sffn STRAPS Si MU HA If A AIIAXMW
PACK GIB 18'. STRAPS SVAU 8f ATTAO"
019W SrA#WrZ Sffn EJrPANSOY A2 N
AINIL 2 EAOf A r COWCnOV PgWIS
I fa? MANAW 1 AAb Z IW COVMAC7OP HAS
7W aPXW ar ALSO iSW AN OUT" GI►PIAo PER
Gadt sm 6071
FR 3�
ND1FS
1. STEPS rO BE J1410 DEFOYPA/ED BAR
GAL VAN /ZED SAFETY STEPS GYP EQUAL.
2 57EPS ARE 70 BE IN PLACE BUWE
MANHOLE SEC77LWS ARE INSTALLED.
J CASTING rO BLS` PER DRAKING BR2. 9
4 MANHGY.E WC776WS TO BE 6F REIWFGIRCED
PRECAST COV07EM
5 ALL "N75 SHALL BE MOWED.
6 SAN /TARY SEVER MANHOLES SMALL HAW
ALL aVIENOR SURFACES, MIaUDYWG '
OVANNELING COATED (SEALED) M11H A HIG Y
SOLIDS URETHANE COLA ANG' WAS'SER
MC- CaWTAL GYP APPROVED EOUAL,• COLAS'' Or
COA 77NG STIALL BE NHI M
7 RUBBER GANEW XWTS SMALL BE IN
CaVf YPII/ANCE N1TH ASIA/ C -443
8 OYANNEL HEOYT SMALL BE A MINIMUM OF
314 Of - 7HE /N,9DIE DYAMEMR OF THE LARGEST
PIPE.
9 CGWNEC7TOWS M MANHOLE 9YALL dE MADE
USWG OW ADAPMR,, K6R- -N -SEAL 801075 6R
APPROVED EQY/AL
RIV
I 10' 4#N.
6" fiMDWG SEVER APE
I
7FE WhY 6" .SLOE OI lur I GZ'EANGrIT -SEE
DETAIL LEFT
2 "x 4" SW .SERVILE MARKER PA /NT Uol°E"R
PW770V MH17F ANS S71NOL 6W SW
#DUNG "SE"NER" WTH 3" HIG Y MACK LETIFRB
AND A HIRE NIPAPP0 ARAI/WD 1HE SW AND
EX75NDED M 7HE 70P aF 7HE STUD.
SIDE SEWER DETAIL
NO SCALE
60" ALL OWAME MAX.
FOR CAST NOW PIPE
a? DUCTILE RM PIPE
ctiwcwE7E ,
MOCKING
5" SW AU11ET ME
SEVER MAIN
CMG ME7F 6LOCKNG ANGLE"
`D
OF TEL" A T MAIN OVER 25'
E�TM�G
1X ANN 5X WE
HQfl7QVTAL
` SENfR MAIN
TYPICAL SW WNUR ELEVA MW
NOTE
UNLESS OTHERNISE SHONN aN PLAN, SIDE SEVER SHALL HA Vf A ANN /MUM
4' GO7VER AT PRIA Ewy aw GYP .i 5' LONER IRAN THE LONEST HOUSE
ELEVA AGW, NflMhf ER /S LONER.
UNLESS OTHERIMSE APPIROWD Br THE aTY, MAKE TAP 7HROOW CAST
/ROV SADDLE ,SEa R1ED 70 SEVER MAIN IMTH STAINLESS STEEL BANDS
NNEN C WNECTING NEW S)E SE'NERS 70 EXISANG MAIN.
N7Td 4FIED aA Y, PLAIN AND A9NF0RffD GONO 7F D. /. PPE AAV C Z
PFF SE"NER MAINS ARE TO 6E CWE DN#LLED
SIDE SEWER DE TA Am
NO SCALE
5 -30 ?403
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
•L'��� Date
Date
Date
.oY
1a 6 -12 -05
14711 NE 2ft Ploa, # 101
N. IN 0 wasmigion 98007
425.885.7877 Fox 4 25.885.7963
'cosm ENGINEERING
DESIGN PLANNING
�zm
SURVEYING
SANITARY SEWER DETAILS & NOTES
iCANMEO MR ! t
�J
aJ121l W
?r .► .,pi. M �► y