HomeMy WebLinkAboutS-32020241 1
summ
Mum
FOR APPROVAL
g
Vote
BY
DATE IL-I-jov
Byd 0
DATE
;A
BY
J
By
DATE
tEl
BY
01:
3
W
OW°
D---
2U)0
or
Z
�V)
0�=MEMO
Ld
o
2
Z
Y
J
0
IT!
z
SANITARY SEWER NOTES &SPECIFICATIONS
1. ALL KWK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND
SPECIFICA TIONS OF THE C/ T Y OF REN TON U TIU T Y DEPAR TMEN T AND THE LA TES T
ED1 TION OF THE WSO T/APWA STANDARDS AND SPECIFICA TION&
2. THE HOURS OF WORK IN THE STREET RIGHT -COIF -WAY SHALL BE L /A417ED TO &30
A.M. TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY
THE DEPARTMENT OF PUBLIC WORKS AT 235 -2620. ALL STREET CLOSURES,
PARTIAL, OR FULL, SHALL BE APPROVED BY THE DEP'AR714ENT OF PUBLIC WORKS 24
HOURS IN ADVANCE. THE POLICE DEPARTMENT, AND 911 SHALL BE NO 7IF/ED 24
HOURS IN ADVANCE.
3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE IMTH ~STANDARD SPECIFICATIONS
FOR MUNICIPAL PUBLIC WORKS CONSTRUCTION" PREPARED BY WASHINGTON STA TE
CHAPTER AMER /CAN PUBLIC WWKS ASSOCIATION, LATEST EDI71CMV (APWA) AND
CITY OF RENTON STANDARD SPECIFICATIONS,
4. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL
BE THE CONTRACTOR'S RE-SPONSIB/L/TY TO VERIFY THE TRUE AND CORRECT
L OCA TION SO AS TO A MD DAMAGE OR DISTURBANCE.
5. A PRE- CONSTRUCTION CONFERENCE AND A 24 HOURS NOTICE SHALL BE REQUIRED
PRIOR TO S TAR TING NEW CANS TRUC TION. IT SHALL BE THE CON TRA C TOWS
RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING
CONSTRUCTION. (INSPECTION WLL BE ACCOWPUSHED BY A REPRESENTATIVE OF
THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
N077FY THE UTILITY DEPARTMENT 24 MOLARS IN ADVANCE OF BACaKnLL ALL
CONSTRUCTION.
6. CON TRA C TOR IS SOLELY RESPONSIBLE FOR THE MEANSy METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF Wl7RKERS AND OTHERS ON THE
CONSTRUCTION SITE:
7 IT SHALL BE THE RESPONSIBLE T Y OF THE CON TRA C TOR TO OBTAIN S TREE T USE
AND ANY RELATED PERM17S PRIOR TO ANY CONSTRUCTION.
8. PLANS APPROVED BY THE C4TY OF RENTON, PUBLIC WWKS DEPARTMENT SHALL TAKE
PRECEDENCE OVER ALL OTHER PLANS
9. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SLTE WHENEVER
CONSTRUCTION IS IN PROGRESS.
10. THE CONTRACTOR SHALL PROVIDE THE CITY OF RENTON WITH AN AS-BUILT
DRA W1'NG OF THE SANITARY SEWER SYSTEM W NC H HAS BEEN STAMPED AND
SIGNED B Y A LICENSED PROFESSIONAL ENGINEER OF LICENSED
PROFESSIONAL SURVEYOR.
11. BACKFILL SHALL BE PLACED EQUALLY ON BOTH SIDES OF THE PIPE IN LAYERS
W1 TH A LOOSE AVERAGE DEPTH OF 6 /NGHESr MAXIMUM DEPTH OF & INCHES,
THOROUGHLY TAMPING EACH LAYER TO 95 PERCENT OF MAXIMUM DENSITY. THESE
COMPACTED LA YERS MUST EXTEND FOR ONE PIPE &AMETER ON EACH SIDE OF THE
PIPE OR TO THE SIDE OF THE TRENCH. MATERIALS HOT AMAX PATCH SHALL BE
PLACED W! THIN 10 DAYS AND SHALL BE PER CITY OF RENTON CURRENT
STANDARDS.
13. DATUM SHALL BE CITY OF RENTON., U.S.C. AND G. S
14. ALL DISTURBED AREAS SHALL BE SEEDED MULCHED OR OTHERWISE STABILIZED TO
THE SATISFACTION OF THE DEPARTMENT FOR THE PREVEN7I00V OF ON -SITE EROSION
AFTER THE COMPLE71ON OF CONSTRUCn0N.
15. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED
FOUNDATION IN ACCORDANCE WITH SECTION 7- 02.3(1) OF THE CURRENT STA 7E OF
WASHINGTON STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION.
THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF
THE FOUNDATION AMA TFR /AL AS WELL AS PLACEMENT AND COUIIPAC71ON OF REQUIRED
BEDDING MATERIAL TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE
WILL BE SUPPORTED ON A UNIFORMLY DENSE UNYIELDING BASE. PIPE BEDDING
SHALL BE PEA GRA VEL 6" ABOVE AND BELOW THE PIPE.
16. SANITARY SEWER PIPE SHALL BE PAL YWN YL CHLORIDE (PVC) RUBBER GASKE TED
AST 1W D 3034, SOR 35, OR DUCnLE IRON CLASS 50.
17. IN UN- IMPROVED AREAS, MANHOLE TO EX TEND ANN /MUM 6 INCH AND MAXIMUM 18
INCH ABOVE FINISHED GRADE. IN PAVED AREA, COVER MUST SLOPE IN ALL
DIRECTIONS TO ASIA TCH PA WNG.
1/2'
1/8" RAISE -112' *$Ot
Sawa
CAST WQV RIWG AAA CODER
IV wo • ay.. *86 Ap
1w
314' SPACES SPACED -314'
AS kWCA TED-H T. 1/8'
.0
1•►
12 "0
FIBER JOINT -
PACKING
I
PROPERTY LINE
SIDE SEWER MAIN TO BUILDING SEWER
. � I FUTURE
6 " SEWER PIPE 6-0, 01BLDG SEWER
6*" SIDE OUTLET TEE ?; „
2X4 STUD SERVICE ARKER
PAINT UPPER PORTION K441 TE
w AND S TEN CI L ON SIDE WORD
"SEWER" WITH 3" HIGH
4 BLACK LETTERS.
6 " SIDE SEWER & BUILDING SEWER
PLAN
6* SIDE SEWER
1: 3.• 5 MIX NO TE:
CONCRETE 600 ALLOWABLE AMAX SIDE SEWER SHALL HA VE A
BLOCKING FOR CAST OR MINIMUM 5' COVER A T PROPERTY
UCT/LE IRON PIPE. LINE OR 3 -5' LOWER THAN THE
6 "MIN LOWEST HOUSE ELEVATION, WHICH-
1 25' AI/N E VER IS L O WER.
6 M/N HORIZANTAL
6 SIDE OURET TEE
SEWER MAIN
CONC. BLOCK /NG ANGLE
OF TEE A T MAIN OVER 25'
ELEVA TION
JS
25'
G01�
i 2X MIN SLOPE
" HORIZON TAL
TYPICAL SIDE SEWER
ELEVA TION
�— 4 3/4'
i
I
EXISTING SEWER MAIN
f6" SIDE SEWER
6 " TES T TEE
TO BE INSTALLED
AT CONNECTION
NOTE:
MAKE TAP THROUGH CAST IRON
SADDLE SECURED TO SEWER MAIN
IMTH STAINLESS STEEL BANDS
WHEN CONNECTING NEW SIDE
SEWERS TO EXISTING MA /N.
VITRIFIED CLAY, PLAIN &
REINFORCED CONCRETE, D1 &
C1 PIPE SEWER MAINS ARE TO
BE CORE DRILLED.
SIDE SEWER SERVICE DETAIL
TYP. SEE SHTS. 15 & 16
•
CASTING INLAND FDRY
aR EQUAL. PTpf714
;EE DETAIL 5.1.4
4DJUSTMEN T 4' MIN.
:ONE
/ORTAR "N TS
TEPS- 3/4 " DEFiWA&D BAR
w PEPS SHALL BE INCLUDED
1/2"
NRETE RISER BY PIPE INC.
APPROVED EQUAL
MAX PIPE SIZE- 21 "' I.D.
LADDER -STD. ALUMINUM
OR GAL VANIZED STEEL.
CONCRETE SHELF
PRECAST BASE SECTION
oe
• OR CAST IN PLACE
6" AAGN
6~ MiN.
SAN/ TAR Y MANHOLE TYPICAL DE TAIL
(Mn)
TYP. SEE SH TS. 15 & 16
NOTES,
1. STEPS TO BE 3/4" 0 DEFORMED BAR GALVANIZED SAFTEY STEPS OR EQUAL
2. STEPS ARE TO BE IN PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED
3. CASTING TO BE OLYMPIC FOUNDRY NH30 WITH NH30 D/T OR EQUAL. PER DWG.
4. KV*40LE SECTIONS TO BE OF REINFORCED PRECAST CONCRETE
S. OPENING SHOULD BE ON DOWNSTREAM SIDE.
6. ALL JOINTS SHALL BE GROUTED.
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR
SURFACES, INCLUDING CHANNELING, COATED (SEALED)
WITH A HIGH SOLIDS URETHANE COATING
WASSER MC- CONSEAL OR APPROVED EQUAL
COLOR OF COATING SHALL BE WHITE. 24 0$x 6" FRAME AND LIP
/-PER DRAWING BR29.
-- 2 24" x 6" FRAME AND LOCKING LID
PER DRAWING BR29.
ADJUSTING INGS OR BLOCKS
AS REQUIRED
PRECAST VALVE
CHAMBER CONE
R.C.P. OR EQUAL
PLUG TO K SEALED IN SAME
MANNER AS ASIA /N SEWER JOINTS.
TERIAL
A��A�� CLEAN —OUT DETAIL
ROLL 1 917
4 " MIN TO 12" MAX
16"
5'
POURED IN PLACE RASE
EVRA SHALLOW
SAN/TARP A/ANHALE TYPE C
r s.
.K
�1
i
R. . . a .. . • ♦ •
• •
SHALLOW TYP£ B
SANITARY A/ANHQL£ DETAIL
5- 3?O ?02
a„
I" TO irl
LE r TO
RECOMMENDED
FOR APPROVAL
Vote
BY
DATE IL-I-jov
Byd 0
DATE
;A
BY
DATE in
By
DATE
tEl
BY
DATE
FTI
D---
zCA�NrE0 APR 8 x o-06S
•