Loading...
HomeMy WebLinkAboutS-320605SANITARY SEWER AND WA RMAIN EXTENSION PLAN a I T 1. IN li I ( IIII cl z z mF U ° __ w i s w - w . w - s - w - - - • w -w w . , . - - i- . .rte . w - Y I W w 3 U . 15 INSTALL ; v o STA. 6 +89.96, O.C. W ' ��.. • ., '` :;: 14 INSTALL: � 1 co -8'x8' CROSS (FLxMJ) (VERTICAL) W 4+89-23, O.C. 8 - 1 " PLUG z (MJ) 1 -8'x8` CROSS (FLxMJ) (VERTICAL) € W 1 -8` BOND FLANGE (FL) i-Rw Ptur. Imul p Q W O » ° 1 -2" TEMP. BLOW -OFF ASSEMBLY w 1 -8 BLIND FLANGE (FL) z n � « (BOTTOM OF CROSS) c = 1 -8 xs TEE (FLxMJ) z V + 0 1 -2' TEMP. BLOW -OFF ASSEMBLY ° ° 1 -6" GATE VALVE (FLxMJ) Z Q g 0 1 -8'x6' TEE (FLxMJ) -' RI 14 LF 6' a EXTENSION z Q W 0 1 _6» GATE VALVE W OOK CREEK AND GREENBELT _ m � J , . I « vE (FLxMJ) � 1 -FIRE HYD. PER CRY OF , Q S01 47 39 w 916.00 RENTON STANDARDS 00'49 1 o E 46.39 1 -FIRE HYD. PER CITY OF COW. ELUMNIG 0 RENTON STANDARDS SEE CONNECTION DTL. 2, SHT. C16 A CONC. BLOCKING AND F.H. DTL SHT. C9. o Q W SEE CONNECTION DTL. 2, SHT. C16 5 +' r. 7 AND F.H. DTL SHT. C9. W �L _ ...... ......... _ __.__ _ ___ ____ _ _..__ _ ..... _ .................... _ ................. .._ - • •r �._..� .:..�... - - - - -- _.-. ..... _ ........... ..... .......... ...._.......................... - ....___......_......... ...................... .......................... ..._ --- - w : O 0.0 WATER EASEMENT ........... 1' . ; ,\ .. 3s' 1 ; •' o I K \ \ INSTALL 1 15' WIDE ,i d+ © i •, ` ,R i c / STA. 4 +07.00, O.C. WATER EASEMENT \ 4 U) SSMH 1 TT ' 54 FLATTOP) -- - 1 -8 x6 CROSS MJxFL ._ < O i. INSTALL - • __.._...____._ ' ' ,Y .� SHALLOW TYPE "B` PER FlREUNE - ) STA. 2 I N 6 a ° 2 6' GATE VALVES(FLxMJ) 8 67 +9 , rn C o E , H CITY STD. DETAIL No. 8072 , 3 '. ,. �..� _ TO SPRINKLER 6' GATE 1- 12`x8' TEE (FLxMJ) ` .', �y' �- \ , Q RIM -21.01 ROOM W DDCVA V BUILDING - ) �...__ - - .........._.... .......................... E.r., x _ • 1 >' .. �' 1 8' GATE VALVE (FLxMJ � � \, 1 • BUILDING E1 / VALVE( MJxMJ) VE MJ MJ }- IE =14.73 (8'IN) E3 CONC. BLOCKING - 'Z w • ao ` 15 WIDE ` ; j .o m _ IE =14.63 (8 OUT) �■�23.0 5 INSTALL: TO SPRINKLER » SANITARY SEWER o F-4 15 WIDE ; �� FIRE�NE -- FF 23.0 10 LF 12 DI WTR ': M� W a INSTALL- STA. 64 +94.89, O.C. + / + _ EASEMENT SANITARY SEWER �4> R OOM W DDCVA STA. 62 +09.45 O.C. ( ) °' o EASEMENT TYP. t _- 1- 12`x8' TEE FLxFL O7 INSTALL• o r c ( ) c r STA. 67 +82.91, O.C. _ E • N 1 -12 x6 TEE (MJXFL) 1 -8 GATE VALVE FLXMJ 48 LF 12 DI WTR " _ SSCO PER CITY ( ) 1 -8 x6 TEE (FLxMJ) SM •� a� 45 LF 12 DI W ; . i 1 -6` GATE VALVE (FLxMJ) STD. DETAIL B076 1-12w GATE VALVE (FLxMJ) _T LA AFEA E l INSTALL: 6 1 6" GATE VALVE FLxMJ b m ; ,, = 1 -12 ADAPTOR (FLxMJ) - 5 LF s a ) P1 R �E , 10 LF 6 DI EXTENSION RIM 23.0 STA 65 +4 .84, O.C. EXTENSION IN DETEA�L X07 - -- - - -- 25 FOOT 1 -FlRE HYD. PER CfTY OF = CONC. BLOCKING a 4" RENTON STANDAR - _ - ._._ - _ - - - - _ - 2 "x8" TEE (FLxMJ) .PER CITY OF _ _ T o .� _. 0 1 1 1 -FIRE HYD ��M..=7 - ,».�„� RENTON STANDARDS • c o CONC. BLOCKINGx _ : :: 1 -8 GATE VALVE IE =18.56(6 4>INSTALL: o c 00 IE =18.39(8 OUT) CONC. BLOCKING SSCO PER CITY ' • EXISTING TA. 61+64.45, O.C. (ANGLE PT.) - INSTALL 1 1/2w WATER gyp, DETAIL 8076 ' ° S6 LF 12" - INSTALL 1 1 /2 WATER +- 1 -12` 90' BEND (MJxMJ) s CONC. BLOCKING 1 15' WIDE - ; : DI WTR SERVICE AND METER RIM =23.00 SERVICE AND METER FENCE a' x -, WATERMAIN = IE -20.00 1 rn - BACKFLOW PREVENTER - t'= 15' WIDE I - _ 1 - _ � SEE DETAIL SHEET C10 EASEMENT (TYP.) 90 r. BACKFLOW PREVENTER R• ,' BACKFLOW PREVENTER - Q WATER EASEMENT cn + r • +bb_- +,. , �� ��;, ---_ ! r. • --= -� +D SHEET ;. - SHEET C10 - EET C 10 , , SEE DETAIL 00 1 I 6 LF 1 DI WTR 184 LF 12 DI WTR - SSCO PER CITY 136 LF 12" DI WTR cr 6 ,,a. . .: .wr - w. .vv.:. .. ..w .,rMwwrwa ....... --iw ..�...':..... �i� . :"""on,wv. M � -I --- "'�'�'VII�"- .'�'�I.l - ^�.•.�'.�•*'.• �• �V7 --- M/ v -� _ DETAIL I o 16 .."�,w, 1 I - .:�..r..c :.....:::""'".`` ._ . _ -__ RIM-23.00 _ ""'.1♦,�r- .....r.:::........ �.: ::.. _....__. _ ---� �» _____� IE =20.00 _ .. - rT, -;-- ---- 296 U o DI SS O 0.4X _. 365 LF 8' DI SS O 0.4% Pt I -. f. --•-- 41 LF 12 DI WTR PIV cv 01 r �- --�- R • « 58 LF SEE DETAIL' SHEET C10 DI WTR T rRELINE r o LA co 15 WID SSMH 3 •' r 15' WIDE 2.5' WATER EASEMENT r a NEW 1 IRRIGATION I =- - ' .- -1-- SANITARY SEWER _ __ SHALLOW TYPE B PER = '4 'Q = TO SPRINKLER • EASEMENT (TYP.) CITY STD. DETAIL No. 8072 , METER W/ BACKFLOW - ROOM W /DDCVA RIM =20.92 PREVENTOR (DCVA) ; INSTALL 1 1/2w WATER IE= 17.21(8 "IN) NCO PER CITY F - , . . PER CITY STD. SERVICE AND METER - -17 1 ) - . _:_ ...__.ry,.,.,, -• :: u• :,::::x:::x :::x:::;.: FDC f >: IE 1(8 "OUT STD. DETAIL 8076 - � � 27 LF 12 I - --� -- - --�- - -� -- .. ac m ADJUST EXIST. HYDRANT DI WTR � - SSMH �2 (54 FLATTOP) 1 - -! � RIM =23.00 SHALLOW TYPE B PER - IE =20.00 BUILDING E5 .� m o TO FINISHED GRADE "I CITY STD. DETAIL No. 8072 BACKFLOW PREVENTER 16 -" "'" r'x`L�' -`�= `= Wiz` -;,- __.2 - Z-' _ w AND INSTALL 5" _ RIM =21.44 SEE DETAIL SHEET C10 STA." 4 +78.27, O.C. co �,,.• - - - - - FT-=23.0 r STORTZ ADAPTOR 1-8"x6* TEE FLxMJ - CN f IE =15.65(8`IN) (FLxMJ) `�,� -- 1 -6 GATE VALVE FLxMJ }. u• STA 16 +95.82 -: �_ = - - - VALVE( FLxMJ) 9 INSTALL: IE= 15.55(8 OUT) SSCO PER CITY 26 LF 6" DI EXTENSION an ) ° SW 34th ST.) = y 15 WIDE WATER ,n STA. 68 +50.82, O.C. (ANGLE PT.) r i ,� NJ o STD. DETAIL B076 1-FIRE HYD. PER CITY : i P STA. 59 +65.43 -- I - _ 1 -12" 90' BEND (MJxMJ) EASEMENT RIM =23.00 OF RENTON STANDARDS r • "r' �` E - -- - CONC. BLOCKING x ` IE =20.00 CONC. BLOCKING a INSTALL: 2 6` i 15' WIDE A m m m m m a r i STA. 60 +28.59, O.C. ANGLE PT. BUILDING E2 TO SPRINKLER BUI 20 WATER EASEMENT LDING E4 o ° o ° ° Q EXISTING 10 10, 1 -12 90' BEND (MJxMJ) '23.0 ROOM W /DDCVA -_ N o TO SPRINKLER -- w, • + ROOM W /DDCVA F-F=23.0 A+ rn DI WATER STUB CONC. BLOCKING o � UTILITY . , 1 p INSTALL: -' N N o cr Q EME J O o � N o STA. 68 +82.61, O.C. °f °D N 1Q INSTALL- i 15' WIDE 1- 12 "x6" TEE (MJxFQ STA. 5 +32.77, O.C. ;5' WATER EASEMENT 1 -6" GATE VALVE (MJxFL) _ m m 1 -8'x6' CROSS (MJxFL) + - - CONC. BLOCKING " r m 39 LF 12 DI WTR a x m m -' W ;. 2 -6" GATE VALVES(FLxMJ) I I "� cod (of 937.16' _..._ _...' , vs v '. . • ' D o - FH z ' " . z o c�' °D EX. 10" WATER - .• EX. 10" WATER � INSTALL: N 712"02* ISTALL: , (� S•TALL.O FIELD LOCATE, REMOVE 1 RCN• SIDE SEWER SHALL BE PROVIDED WITH EX• FH �^ A. 6 +4 .1 .C. 11 STA. 70 +60.11, O.C. U. CUT IN: "CROSS (FLxMJ) (VER'TT ) , � o AN KIN O r� EX. FH - PLUG D BLOCKING r 1 -12 x6 TEE(MJxFL) 1 1 -12 PLUG (MJ) �,Ir BACKWATER VALVE BY MANHOLE PER DETAIL SHEET. ; _ � 1 -10 x8 WET TAPPING TEE A. 0 +99.36, O.C. r H INSTALL: VALVE SHALL BE MODEL 675 P BY NDS. 1 -8` GATE VALVE(FLxMJ) 1 -6 GATE VALVE(MJxFQ 1 -10" TEE (FL) 1-12 BLIND FLANGE (FL) (BOTTOM OF CROSS) Z STA. 60 +03.57±, O.C. I 25 LF 6 DI EXTENSION 1 -2 TEMP. BLOW -OFF ASSEMBLY W W W < 2 (FLxMJ) (VERTICAL) SEE SHEET Cl FOR CONC. BLOCKING 1 -FlRE HYD PER CITY OF 2-10 GATE VALVES 1 -10 x 10 CROSS FLxMJ RTICAL SEE CONNECTION DTL 3, SHT. C16 () 0 0 o o g° 1 -10' PLUG (MJ) FiTT1NG LOCATION IN RENTON STAN OS 1 -12• GATE VALVE W Ci �. • O v vN v a � N u$ 1 -10 BLIND FLANGE (FL) PROFILE VIEW. c�NC. BL 2 -2 LF 1 o a SPOOLS w � (BOTTOM OF CROSS) 6 20 cc 1 -2 TEMP. BLOW -OFF ASSEMBLY w LLJ A.. 5 Z 1 -12'x 10" REDUCER(FLxMJ) oz ZZ W � Q N N� " Z cr tML" NOTES 1 -10' GATE VALVE(MJxFL) a Z Q) cD CA I I w W CONC. BLOCKING SEE CONNECTION DTL. 4, SHT. C16 w 00 BY: ° N W 2, ALL SANITARY SEWER SERVICES SHALL. BE PROVIDED Z N N LAJ crcr 1 Y V) WITH BACK WATER VALVE PER CITY STD. = rIMAM I AL DATM - BAW OF BEARNINI OM x/'0'0 J W') qp M'! N '- • w � (BOTTOM OF CROSS) 6 Z U p 1 -2 TEMP. BLOW -OFF ASSEMBLY w LLJ A.. 5 Z 1 -12'x 10" REDUCER(FLxMJ) oz ZZ W � Q N N� " Z cr tML" NOTES 1 -10' GATE VALVE(MJxFL) Z cr- Z Q) cD CA I I w W CONC. BLOCKING SEE CONNECTION DTL. 4, SHT. C16 w 00 BY: Date: W 2, ALL SANITARY SEWER SERVICES SHALL. BE PROVIDED Z N N LAJ ..� V 1 Y V) WITH BACK WATER VALVE PER CITY STD. = rIMAM I AL DATM - BAW OF BEARNINI OM x/'0'0 By: Date: v THE MAXIMUM AVAILABLE FIRE FLOW FROM THE EXISTING - vmnCA. DOW _ RAW OF 8 VA11M M1'R011ED ` 12" WATERMAINS IN SOUTHWEST 34th STREET, IN OAKESDALE 00 A S.W. CITY OF RENTON BM 2106 (NAVD 1988) �D Jam' 5 By: Date AVENUE SOUTH WEST, AND FROM THE 12' LOOPED WATERMAINS AROUND THE SITE IS LIMITED TO 5, ypm AT 20 PSI 000 /r'1 SLAV. • 19. Of FEET RESIDUAL PRESSURE. THE STATIC PRESSURE IS APPROXIMATELY By: Date 70 PS1 AT FINISHED FLOOR ELEVATION = 24.0' ROLL 20 � i` r cc I N C9 Of C IV, U, IL Z coV2 3 w .J F_ F. •r W �j 4 c) CO) W Y Q O a: 08 .J .J U. W4 C4 W� W Ova% o � Q N CL cD qNEW � 6 Z U p DKB w LLJ A.. 5 Z X d oz ZZ W � Q N N� " Z cr KI8 OO N Z cr- Z Q) cD CA I I w W cV 3 n n w 00 LO CN •� n W CV 00 Z N N LAJ ..� V 1 Y V) AS J °�� No !EV"m v Z DAB M1'R011ED ` 4 Np Jam' 5 D COQ 1 -10 "x12• INCREASER CITY OF RENTON CONC. BLOCKING SEE CONNECTION DTL 1, SW. C16 C>EPARTMENT C w= PUBLIC WOFRK9 � 0 5672 04 �4 cisit " Nl� /ONA l \` ExPRtS -9/2-ST65 6 ADDED HANDRAIL AND LANDSCAPE 8W DKB 11/09/04 A.. 5 REVISED PER CITY REM COMMENTS PRA OKB 10/27/04 4 REVISED PER CRY REVI V COMMENTS KI8 DKB 9/22/04 3 REVISED PER REVIEW COMMENTS LK AS 8/01/04 DOMED 2 REVISED PER CITY REM COMMENTS 8SW AS 2/12/04 CPAVY 1 ADDED FIRELINE TO BUILDING 8W AS 1 /19/04 °�� No !EV"m v om DAB M1'R011ED 023. • 18/l/04 DATE '40 No SCALE 900K PACE K w 's 04 - or C4 m V C N O 0 N 0 0 N 0 0 N w a, X c 0 W 0 0 lot 0 n v 0 V a 0 0 a 0 10 Ln 0 0 v r, C a� c c a c O O z i� • M IM r1 :7 J C V: C r r. C ~N r o rn N z W N