Loading...
HomeMy WebLinkAboutS-325604�z kr) p M ° t c 17; CL cm ac ui a vi 0 ie 0 J a x c oC C) C i CD Y 5 QCV15W "ItS n/ TVA J A 0 a" POST INDICATOR VALVE (MJxMJ) PAINTED BLUE " 2 -3/4 SHACKLE BOOS PER 4" 9 BEND MJ CITY OF REVLON SPECIFICATIONS 4 "x 2 1 /2" FIRE DEPARTMEN 1 DOUBLE 0' ) J Q CONNECTION FOR STAND PIPE W = 4 4" ADAPTER, FL.x SCREWED ONE EACH SIDE ONE EACH ES CAST IRON HOSE CAPS. DE EQUAL TO GR NNEL FIG. U ti PRECAST CONCRETE VAULT WITH 3 - 3'x 3 4% 4"x 6" BULL HEAD TEE, FL. 1682 WITH HOSE CAPS FIG. 1333. " 13 LF 4" D.I. �— 4 90' BEND (MJ) � ...� HINGED STEEL PLATE COVERS. " " 6" PIPE FL.x FL. " 12 7' -O" w DIMENSIONS 5'-8"x 11 -2 x 7 -2 EQUAL TO 6 SWING TYPE GRAVITY OPERATED — d W Z UTILITY VAULT OR EQUAL 2'-0" LONG CHECK VALVE, FL. EQUAL TO 4" FLxMJ ADAPTOR, _ 18" FOR 10" ASSEMBLY MUELLER CO. A- 2600 -6 WITH BALL o 1— CD 17 1 2" FOR 8" ASSEMBLY `r THE BY —PASS ASSEMBLY SHALL BE / 3' —p" DRIP VALVE AT BOTTOM W +� � 18 1 2" FOR 6" ASSEMBLY " LADDER WITH M cn INCLUDED AS PART OF THE DETECTOR / INSTALL EPDXY NON- SHRINK GROUT (TYP.) 4 FLxW ADAPTOR .� w W Z DOUBLE CHECK VALVE ASSEMBLY. I�- -11 - 2 6" PIPE, FL.x FL. 3'0" LONG •• SUPPORT BARS 2 -4 w W 0 w 10 ", 8" OR 6" FL.x P.E. 6" & 8" ASSEMBLY. PER OSHA Z z 6 SHORT RADIUS 90 BEND FL. W PIPE WITH COLLAR 18" (� 10" ASSEMB08% 6" REDUCING � OC g FROM P.E. � -{� -- 39-211 •� 90' BEND, FL. NON-SHRINK Z � 10 ", _ 3' -8" LONG 12' ., 6 90' BEND FL. : • : . W 8" 3'--6" LONG o EPDXY Y LL- 6" - 4' -0" LONG GROUT 2' -4" 5'-- -�► 4" TEE (MJxFL) ; 4" TEE (FL) W 12 ALL AROUND — W �� (•,; ... DEADMAN BLOCK 0 u A- A 2- 6 I REQUIRED. DEADMAN BLOCK j • � " ., .. REQUIRED WITH 3 10 8",6" FL x MJ ADAPTOR CONCRETE BLOCKING —�� " PRECAST CONCRETE VAULT WITH 2 3 "x3" HINGED SHACKLING TO TEE ui 10 ASSEMBLY 10 x10 " x8 TEE FL. STEEL PLATE COVER. OUTSIDE DIMENSIONS ALL DETECTOR DOUBLE CHECK VALVE ASSEMBLIES 8" ASSEMBLY 8 "x8 "x6" TEE, FL. SHALL INCLUDE RESILIENT SEATED SHUTOFF VALVES ELAN 6" ASSEMBLY 6'x6 "x6" TEE, FL. 4'- 8 "x7' —O . (EQUAL TO PIPE INC., OR UTILITY VAULT 2 AND TEST COCKS. AND APPROVED CROSS— CONNECTION WITH 57 -7L —B, 2 3'x3' DIAMOND PLATE DOORS) _ � CONTROL ASSEMBLIES PER D. S.H.S. LATEST APPROVED LIST. 10 ", 8 ", OR 6" GATE VALVE, . FL.x MJ, WITH INDICATOR POST. TOUCHREAD PITLID SENSOR _ DOUBLE CHECK VALVE ASSEMBLY INCLUDES TWO RESILIENT SEATED SHUTOFF VALVES. INDICATOR POST VALVE SAME SIZE " " " MOUNTED ON STEEL PLATE TWO PIECE CAST IRON VALVE BOX, V; AS DOUBLE CHECK VALVE 6 ,4 OR 3 GATE VALVE (FLxFL) NON- RISING STEM W 10 ", 8 ", OR 6" FLANGED COUPLING ADAPT (MUELLER CO. OR EQUAL). WITH HAND WHEEL EQUAL TO MUELLER CO.A- 2380 -6. " " COVER EQUAL TO OLYMPIC FOUNDRY CO. EQUAL TO ROMAC. " " .• 3 4 REGUDLAR BASE OSECTONIOLENGTIH V < <� 10 8 OR 6 DUCTILE IRON CLASS 52 NIPPLE PIPE, CEMENT LINED, LENGTH TO FIT. TO FIT. a VALVE NUT EXTENSION IF REQUIRED (DWG BR46 /PAGE 8090) a 6" OR 4" (FLxPE) CEMENT LINED w v, DUCTILE IRON PIPE CLASS 52 6 4" OR 3" GATE VALVE F� N !� /""1 a (FLxMJ) EQUAL TO MUELLER 0 3' -6" LONG WITH COLLAR 20" FROM P.E. EQUAL TO THOSE SUPPLIED BY CO. A- 2380 -20. PACIFIC WATER WORKS CO. INC. F �Z _ F77 -1 W a NOTE: 3,. „�, I 1. LOCATE VAULT IN PLANTING AREA NOT IN PAVING 12" AROUND 14" 36 TO 42 0 I 2. 4 IRON CEMENT LINED " AND LARGER BENDS AND TEES TO BE CAST 6" OR 4" PExPE CEMENT UNED M _4 12" DUCTILE IRON PIPE CLASS 52. rn _ ., C LENGTH TO FIT. 'aid 3. TEMPORARY SUPPORT SHAH BE PROVIDED UNDER C .4 6" PIPE VALVES AT THE TIME OF INSTALLATION TO CENTER 6" OR 4" FLEXIBLE FLANGED a 18" FOR 10" ASSEMBLY _ 2'_6" 3' -2" FL. x SCREW THE PIPE IN VAULT OPENING. AFTER COMPLETE COUPLING ADAPTOR, ROMAC OR 17 112 ; FOR 8" ASSEMBLY INSTALLATION REMOVE THE TEMPORARY SUPPORT APPROVED EQUAL. 18 112 FOR 6 ASSEMBLY I AND INSTALL CONCRETE SUPPORT PAD OR 6 ",4" OR 3" COMPOUND WATER METER (FL) PADS OR ADJUSTABLE >!: EQUAL TO SENSUS SRH COMPOUND METER WITH 7' -2" ADJUSTABLE PIPE SUPPORT. TOUCHREAD PITLID REGISTER do SENSOR. PIPE SUPPORTS. 4. INSTALL GALVANIZED LADDER FOR ACCESS. REDUCE AT METER WITH 4 "X3" FLxFI a NOTES: CONCENTRIC REDUCER. SLOT BOTH SIDES do CLEAR ACCESS OPENING o ffii V-1.1 5. AFTER FIELD INSTALLATION, MAIN DDCVA AND DEADMAN BLOCK SHALL BE DESIGNED BOTTOM OF VAULT 6" 90' BEND FL. BY-PASS DCVA MUST BE TESTED SATISFACTORILY AND INSTALLED SO IT BEARS AGAINST _ 2' -11 " BY A DEPT. OF HEALTH CERTIFIED BACKFLOW SUFFICIENT UNDISTURBED EARTH SO AS TO ASSEMBLY TESTER. TEST REPORT TO BE SUBMITTED SUPPORT THE DESIGNED THRUST. NON- SHRINK 6" MIN. DRAIN TO GALVANIZED STEEL LADDER TO CITY OF RENTON WATER UTILITY ENGINEERING GROUT (1YP) DAYLIGHT OR STORM DEPT. PRIOR TO ACTIVATION OF NEW LINE. - DRAIN SYSTEM WITH �, , � _ _ GENERAL NOTES: o CATCH BASIN OR MANHOLE 6. INSTALL. BRASS PLUGS AT ALL TEST COCKS �� Y O ALL METERS AND BACKFLOW PREVENTION DEVICE COMBINATIONS ARE NOT Y O,� `a COMPACTED FOUNDATION GRAVEL END VIEW �i `'� SHOWN OR INCLUDED IN THE STANDARD DETAIL DRAWINGS. IF YOUR INLET OUTLET - l ) + PARTICULAR COMBINATION IS NOT SHOWN, AN APPROVED DRAWING WILL BE d PRE CAST \� REQUIRED BY THE UTILITY ENGINEERING DEPT. FOR ITS INSTALLATION. I THE PRINCIPAL REQUIREMENTS REGARDING VAULT SIZING ARE THE LENGTH ��� -��0� DMDER W OF FITTINGS OR THEIR CLEARANCE FROM THE VAULT WALLS, (WHICH N a a CLEARANCE SHALL BE A MINIMUM OF 12 " FROM THE ENDS AND THE SIDE Y W NTS CLEARANCE SHOULD BE AS TYPICALLY SHOWN ON THE VARIOUS STANDARD NTS TOP OF MANHOLE COVER, 611 V A DETAILS). 3 watel' Meter _._ - 13 -1 FLUSH W/' ADJACENT x o GRADE (TYP. 3) PLAN O ° O 8 E FIRE HYDRANT SHALL BE COREY -TYPE EQUAL TO IOWA F -5110 z 3" VENT. SEE PLAN OR COMPRESSION TYPE SUCH AS CLOW MEDALLION; M & H 929 - 18" TO 20" BEHIND BACK OF CURB GREASE INTERCEPTOR NOTES . FOR CONTINUATION " AND MUELLER SUPER CENTURION 200 WITH 6 MECHANICAL JOINT oR 12 BEHIND BACK of SIDEWALK GAS TIGHT MANHOLE FRAME 6 INSPECTION TEE a INLET WITH LUGS. " THAT IS ADJACENT TO CURB & COVER, MIN 24 "0 I.J., PVC TYPE PIPE (TYP3) PROVIDE CLEANOUT BOX Q 5 -1/4 MAIN VALVE OPENING. TWO 2 -1/2 HOSE CONNECTIONS 1. INTERCEPTOR do MANHOLES SHALL BE RATED FOR H2O LOADING. ADJUST TO GRADE (TYP 3) NATIONAL STANDARD THREADS. 4 PUMPER CONNECTION CITY OF 2. SEAL ALL PIPE PENETRATIONS W/ NON- SHRINK GROUT OR CAULKING. VAULT SHALL BE Is � - _x -_ — ' I I 1 .1 1 - A v w SEATTLE THREADS WITH A STORTZ ADAPTOR, 4" SEATTLE THREAD TWO - -PIECE CAST IRON VALVE BOX WITH LUG TYPE FLEXIBLE Al Q " " COVER. EQUAL TO OLYMPIC FOUNDRY CO. STANDARD WATERPROOFED W/ COAL TAR COATING OR EPDXY, OR UTILITY DEPT. APPROVED EQUAL. CONNECTOR ' '' _ _ _ ' 4. ' '' X 5 STORTZ, ATTACHED WITH 1/8* STAINLESS STEEL CABLE. a v 8" TOP SECTION WITH REGULAR BASE SECTION LENGTH 1-1/4- PENTAGON OPERATING NUT. FIRE HYDRANT TO BE O TO FIT. VALVE NUT EXTENSION AS REQUIRED (SEE 3. FIXTURES SERVED: ONE COMPARTMENT SINK, ONE DISHWASHER, 1 FLOOR RECEPTOR. (TYP) • - - - - - PAINTED WITH TWO COATS OF PAINT, PRESERVATIVE MAX 4" DWG BR46 ; PAGE B090). 4. STRAIGHT PAINT No. 43--655 SAFETY YELLOW OR APPROVED EQUAL. ) INTERCEPTOR SERVED: PER APPENDIX H OF UNIFORM PLUMBING CODE MIN 2" INTERCEPTOR '' M PUMPER CONNECTION TO FACE ROADWAY ASSEMBLY. RAISED PAVEMENT MARKER TYPE 88 A8 NO. OF MEALS WASTE RETENTION STORAGE SIZE ! '' , FIRE HYDRANT EXTENSION TO BE USED IF REQUIRED. SIIMSONITE TWO -WAY BLUE. PER PEAK HOUR X FLOW RATE X TIME X FACTOR - (LIQ. CAP.) LIQUID 7 to Uf) LO � � L] Ln N �oOO Q a o o c� LEVEL .4- '1 °' 'J) `" °° 0p " 42" MIN CONCRETE BLOCKING L 200 X 6 X 2.5 X 1 3000 GALLONS . Ln Ln � BURY •' 3000 GALLON GREASE 6 MIN. no C> c� r� a a .� CONCRETE BLOCKING % 5. SELECTED INTERCEPTOR: MINIMUM 3000 GALLON CAPACITY • • ' INTERCEPTOR, PRE CAST 6. CONTRACTOR SHALL VERIFY WRT ELEVATIONS PRIOR TO BEGINNING WORK. 4" '' 12" MIN (TYP) 4• ',° ' CONCRETE TANK MIN. N UTILITY VAULT 112 -GA Q 7. MANHOLES do CLEAN OUTS SHALL HAVE WATERTIGHT LOCKING LIDS & CONCRETE COLLARS. F 1- A • - - - - � MIN. 12w COMPACTED 8. DIMENSIONS SHOWN ARE APPROXIMATE, AND MAY VARY DEPENDING ON MANUFACTURER. o CAST IRON TEE. WITH 6" FLANGE SIDE OUTLET. 9. CONTRACTOR RESPONSIBLE TO VERIFY PIPING INVERTS AND ELEVATIONS OF GREASE - r� �_ N N�_ w PEA GRAVEL BENEATH V 6 GATE VALVE (FL X MJ) INTERCEPTOR TO ALLOW PROPER OPERATION. 4 " MIN. - � AWWA C -509, RESILIENT SEAT oc - 10. CONTRACTOR SHALL OBTAIN INSTALLATION REQUIREMENTS FROM AHJ AND MEET ALL OF THEIR 2/3 LENGTH 1 /3 LENGTH NTS REQUIREMENTS. Grease hercoor E _ SECTION t i L, r w w 6 DUCTILE IRON PIPE, CLASS 52 N 16 x 8 x 4 MINIMUM CEMENT LINED, LENGTH TO FIT TWO , 'C Y 4 CONCRETE BLOCK 3 4 STEEL TIE RODS. SEE STD C, ��� C. A SHEET M _ UNDER F+rORAr� ti o Kennydale Elementary School o�TAIL FOR TIE Roos. lozz ��� TER N DEEM w •� »oo NE zetn su..t, Renton, We ,T COVGNLINPOR LV �., a i t" 1/3 CU. YD. WASHED DRAIN ROCK (3w TO 3/81 � N � A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION y a o n' n WATER AND 413 PINE STREET - SINTE 300 P: 206/343 -0460 FIRE HYDRANT ASSEMBLY NTS SEATTLE, WA 9e1 ol F: 206/343 -5691 .;;�'�4�' �w� dire "ed, D� ass �� S R DET �t I1los coo so Ga./ st S% ow 00 r r 4