HomeMy WebLinkAboutS-347336vi
�IJ
i
ii
Q�z
TRACT "A"
/ BLACK VINYL COATED
WSDOT TYPE 3 CHAIN
TRACT H LINK SECURITY FENCE PER
I STD. PLAN L- 20.10 -00
\ 4 8" WET \
C16 WELL VENT
P PER DETAIL
I
_ P
NE 3 -23 -5
\
\
\
DETAIL (SEE SHTS.
C8 & C9)
_� p\ PER DETAIL W/ 011
BOLLARDS PER
O i \ CDR DETAIL #H020
f \
A S P H A L T P V I N G
.r -------------------------- - - - - -�
r - ---------------------
I
OVERFLOW \
STORAGE VAULT
------ - - - - --
L-
- - - - - - - - - - d I
_________ ________ _______J
/
WEr ■■
WELL ■ ■ i VALVE '
VAULT
�ti�i j I
w o
J I 1" POLY WATER /
5� SERVICE LINE \ : 2V2" PVC SLEE
wi �P AERIAL LIGHT MOUNTED ON \ i� / ON WATER
o 0- I POLE (SEE ELECTRICAL DWG.) _ ♦ / SERVICE LINE
z z I 10' TEMP. CONSTRUCTION ESMT. / 4
I / PROPOSED/
°d S � ��� / 48 "0 MANHOLE
TRACT „H„ /
S.
Wo STONEGATE �o° 1 \
:14 0 5 "CE
I /
Ci
Z /
FIH I LL
Roth Hill, LLC Tel 425.869.9448 www.rothhill.com
11130 NE 33rd Place, Suite 200 Bellevue, WA 98004
0
z
a
U
0
z
J
i!
1
1
1
1
I
e I
I
I
I
< .
1
I
I
1
y 1
A e., ,
I
i I
,
d I
I 1
I
A 1
1
I
I
4
I
I
I
I'.
JI
jl
al
0
01
01
,
I
1
I
I
i
I
I
I
I
I '
I
I
I
I
I
I ,
I
I
I '
I
I
I i
w I
w I
� I
aI
wo 13
w
o Iro W
Iw
PROPOSED z
TRANSFORMER
W
>
Q
W
I 'J
I
I z
I
I
I
Hp�
I
I �
I
—�20' WIDE DOUBLE
GATE PER WSDOT
STD. PLAN
L- 30.10 -00
(EXACT LOCATION OF
WATERMAIN UNKNOWN.
POTHOLE TO VERIFY
LOCATION OF WATERMA
ER SERVICE PER r91 ,
K) STD. DETAIL \, U9
i
I
RELOCATE EXISTING
UTILITY BOX
BEHIND SIDEWALK
I
I
I
11
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
1
I
I
I
I
I
I
I
I
li
i
i
GENERATOR SET NOTE:
THE GENERATOR SHALL HAVE A SUPER - CRITICAL SOUND
ATTENUATED MUFFLER. SOUND ATTENUATION SHALL LIMIT THE
GENERATOR NOISE, INCLUDING EXHAUST, TO 45 dba AT THE
WEST PROPERTY LINE, ACCOUNTING FOR THE SCREENING
WALL. GENERATOR SET SHALL HAVE INTEGRATED SUB -BASE
DIESEL FUEL TANK, WITH VOLUME SIZED TO PROVIDE
OPERATION OF THE GENERATOR UNDER FULL LOAD
CONTINUOUS FOR 24 HOURS MINIMUM. THE FUEL TANK SHALL
BE A UL- LISTED UNIT WITH SECONDARY CONTAINMENT, AND
SHALL HAVE A DUAL -WALL TANK OR EQUAL. GENERATOR SET
SHALL MEET LATEST IFC REQUIREMENTS, INCLUDING VENTING.
37847
FOR CONSTRUCTION
RECORDS ONLY
REVISED TO INDICATE
CONSTRUCTION RECORDS
REVISED BY: TERRY VAN WECHEL
DATE: JULY 20, 2012
CONTRACTOR: SHORELINE CONSTRUCTION
THESE CONSTRUCTION RECORD DOCUMENTS HAVE
BEEN PREPARED BY ROTH HILL, LLC. MOST FIELD
INFORMATION PROVIDED BY OTHERS. ROTH HILL HAS
NOT VERIFIED THE ACCURACY AND /OR COMPLETENESS
OF INFORMATION PROVIDED BY OTHERS AND SHALL
NOT BE RESPONSIBLE FOR ANY ERRORS OR
OMISSIONS THAT MAY BE INCORPORATED AS A RESULT
OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.
PROPERTY
INFILTRATION
e
/
SYSTEM
0v1
100' WETLAND
x==
I
II
\
\ \\ z
i z
GENERATOR
l I
o-
\N
o\
I I
I o
W
\
x z
w
T\ \
I
\I
CONTROL
y
I
`\
BUILDING
LOT 1
I I
I
\ \
\ 4 8" WET \
C16 WELL VENT
P PER DETAIL
I
_ P
NE 3 -23 -5
\
\
\
DETAIL (SEE SHTS.
C8 & C9)
_� p\ PER DETAIL W/ 011
BOLLARDS PER
O i \ CDR DETAIL #H020
f \
A S P H A L T P V I N G
.r -------------------------- - - - - -�
r - ---------------------
I
OVERFLOW \
STORAGE VAULT
------ - - - - --
L-
- - - - - - - - - - d I
_________ ________ _______J
/
WEr ■■
WELL ■ ■ i VALVE '
VAULT
�ti�i j I
w o
J I 1" POLY WATER /
5� SERVICE LINE \ : 2V2" PVC SLEE
wi �P AERIAL LIGHT MOUNTED ON \ i� / ON WATER
o 0- I POLE (SEE ELECTRICAL DWG.) _ ♦ / SERVICE LINE
z z I 10' TEMP. CONSTRUCTION ESMT. / 4
I / PROPOSED/
°d S � ��� / 48 "0 MANHOLE
TRACT „H„ /
S.
Wo STONEGATE �o° 1 \
:14 0 5 "CE
I /
Ci
Z /
FIH I LL
Roth Hill, LLC Tel 425.869.9448 www.rothhill.com
11130 NE 33rd Place, Suite 200 Bellevue, WA 98004
0
z
a
U
0
z
J
i!
1
1
1
1
I
e I
I
I
I
< .
1
I
I
1
y 1
A e., ,
I
i I
,
d I
I 1
I
A 1
1
I
I
4
I
I
I
I'.
JI
jl
al
0
01
01
,
I
1
I
I
i
I
I
I
I
I '
I
I
I
I
I
I ,
I
I
I '
I
I
I i
w I
w I
� I
aI
wo 13
w
o Iro W
Iw
PROPOSED z
TRANSFORMER
W
>
Q
W
I 'J
I
I z
I
I
I
Hp�
I
I �
I
—�20' WIDE DOUBLE
GATE PER WSDOT
STD. PLAN
L- 30.10 -00
(EXACT LOCATION OF
WATERMAIN UNKNOWN.
POTHOLE TO VERIFY
LOCATION OF WATERMA
ER SERVICE PER r91 ,
K) STD. DETAIL \, U9
i
I
RELOCATE EXISTING
UTILITY BOX
BEHIND SIDEWALK
I
I
I
11
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
1
I
I
I
I
I
I
I
I
li
i
i
GENERATOR SET NOTE:
THE GENERATOR SHALL HAVE A SUPER - CRITICAL SOUND
ATTENUATED MUFFLER. SOUND ATTENUATION SHALL LIMIT THE
GENERATOR NOISE, INCLUDING EXHAUST, TO 45 dba AT THE
WEST PROPERTY LINE, ACCOUNTING FOR THE SCREENING
WALL. GENERATOR SET SHALL HAVE INTEGRATED SUB -BASE
DIESEL FUEL TANK, WITH VOLUME SIZED TO PROVIDE
OPERATION OF THE GENERATOR UNDER FULL LOAD
CONTINUOUS FOR 24 HOURS MINIMUM. THE FUEL TANK SHALL
BE A UL- LISTED UNIT WITH SECONDARY CONTAINMENT, AND
SHALL HAVE A DUAL -WALL TANK OR EQUAL. GENERATOR SET
SHALL MEET LATEST IFC REQUIREMENTS, INCLUDING VENTING.
37847
FOR CONSTRUCTION
RECORDS ONLY
REVISED TO INDICATE
CONSTRUCTION RECORDS
REVISED BY: TERRY VAN WECHEL
DATE: JULY 20, 2012
CONTRACTOR: SHORELINE CONSTRUCTION
THESE CONSTRUCTION RECORD DOCUMENTS HAVE
BEEN PREPARED BY ROTH HILL, LLC. MOST FIELD
INFORMATION PROVIDED BY OTHERS. ROTH HILL HAS
NOT VERIFIED THE ACCURACY AND /OR COMPLETENESS
OF INFORMATION PROVIDED BY OTHERS AND SHALL
NOT BE RESPONSIBLE FOR ANY ERRORS OR
OMISSIONS THAT MAY BE INCORPORATED AS A RESULT
OF ERRONEOUS INFORMATION PROVIDED BY OTHERS.