Loading...
HomeMy WebLinkAboutS-347341ofn i z BUILDING SEE SHT. Al ASPHALT PAVEMENT SEE SHT. C7 HOT BOX W/ BACKFLOW PREVENTER & YARD HYDRANT 8" VAULT VENT GENERATOR SET ________________________________________________________- I �. 7 °MIN.(T1P.) �� � 118" WIDE I I� 5' -5° DOORS OPEN LADDER J 3'x5' FRP LANDING' I I i 7' BELOW VAULT I I CEILING PER I STRUCT. DWGS. I I I I 48 "x72" ACCESS HATCH, j LW PRODUCTS HD -3C I i I I I I I I I I I I I I I I I i I I i I 1'x1' CONCRETE FILLET W/ I 4 - #4 DEFORMED REINF. j I TREBAR (TYP. OF 4) I I I 1 4\ I I I I L- - - - - -- -- - ---------- - - - - -- - -- -- 12" ROMAC OVERFLOW STORAGE VAULT STYLE 501 FLEX CPLG. SEE SECTIONS, SHT. C13 .fi CHAIN LINK SECURITY FENCE SEE SHT. C7 \ \ 12 "PVC C900 K+1 END 5' SEWER BYPASJxMJ) SEE SHT. C5 + - dIIIYIIu�- ���IIIIIIIII� ��� PHILL Roth Hill, LLC Te1425.869.9448 www.rothhill.com 11130 NE 33rd Plaoe, Suite 200 Bellevue, WA 98004 WET WELL SEE DETAILS, SHTS. C13 AND C14 i \ 8" WET WELL VENT 12" ROMAC STYLE 501 48 "x72" ACCESS HATCH, LW PRODUCTS HD -3C 3'x FRP LANDING - 7' - 7' BELOW VAULT CEILING PER 1. STRUCT. DWGS. r DOORS OPEN 18" WIDE I LADDER I -- ---- ---- 1 - - - -- UNI -HOIST CORE MOUNTED — SLEEVE PER SPECS. (TYP. OF 4) COORDINATE LOCATIONS WITH OWNER. VALVE VAULT SEE - DETAILS, SHT. C15 AERIAL LIGHT \ �� " x x— MOUNTED ON POLE (SEE ELECTRICAL 12 "PVC GRAVITY �WG•) SEWER SEE SHT. C5 12" GATE VALVE (MJxMJ) j GRAVITY SEWER MANHOLE SEE / SHT. C5 / fgSeMF /V / I I 1 I 1 .1 8" VAULT VENT W/ — I I / I I I I / I I I I I I I I I I I I I I 1 I I I \ � I \ I I \ I 1 I I I I I I \r I � I I�� I I � I I � I I I X I 1 I I / I nl 1111 / I I I d TRANSFORMER a / d d - A / d G 4 / / d 4 / 4 / d / 4 d d. L. BRp / w4lwcE WA&w Q 4 d 37847 RE'GISTERF'� 4 Sm,..... FOR CONSTRUCTION RECORDS ONLY REVISED TO INDICATE CONSTRUCTION RECORDS REVISED BY: TERRY VAN WECHEL DATE: JULY 20, 2012 CONTRACTOR: SHORELINE CONSTRUCTION THESE CONSTRUCTION RECORD DOCUMENTS HAVE BEEN PREPARED BY ROTH HILL, LLC. MOST FIELD INFORMATION PROVIDED BY OTHERS. ROTH HILL HAS NOT VERIFIED THE ACCURACY AND /OR COMPLETENESS OF INFORMATION PROVIDED BY OTHERS AND SHALL NOT BE RESPONSIBLE FOR ANY ERRORS OR OMISSIONS THAT MAY BE INCORPORATED AS A RESULT OF ERRONEOUS INFORMATION PROVIDED BY OTHERS. c6 ; .5 - -s 4731;1- w' �I a n o > ¢ cn x 3 d NOTES: —x x x —J Q 1. ALL DUCTILE IRON PIPING AND FITTINGS SHALL BE CEMENT �I LINED CLASS 52 EXCEPT FOR FLANGED SPOOLS (CL. 53) OR a WHERE OTHERWISE NOTED ON DRAWINGS. ALL DI PIPING AND d FITTINGS WITHIN WET WELL SHALL HAVE EPDXY COATED EXTERIOR PER SPECIFICATIONS. 2. BACKFILL AROUND STRUCTURES AND WITHIN 5' OF STRUCTURES SHALL BE SELECT MATERIAL COMPACTED TO 95% PER ASTM 8 "PVC C900 D1557. FORCE MAIN I 3. ALL CONCRETE SUPPORTS TO BE FORMED. SEE SHT. C5 I d 4. ALL PIPE PENETRATIONS IN WET WELL, OVERFLOW STORAGE VAULT, AND VALVE VAULT SHALL USE LINK SEALS UNLESS I 4 OTHERWISE APPROVED. KOR -N -SEAL BOOTS SHALL BE USED FOR PIPE PENETRATIONS IN MANHOLES. ALL PENETRATIONS SHALL BE MADE WATERTIGHT. I 5. ALL MECHANICAL JOINT FITTINGS SHALL BE RESTRAINED d w /MEGALUGS. p 6. WET WELL, OVERFLOW FACILITY & VALVE VAULT SHALL BE COATED INTERNALLY AND EXTERNALLY PER SPECIFICATIONS. 7. CORE DRILL ELECTRICAL & TELEMETRY PENETRATIONS IN FIELD AS REQUIRED. 8. FOR EACH HATCH, PROVIDE ROLL -OUT SAFETY NET PER SPECS. PROVIDE SS SAFETY CHAIN AT EACH OPEN END OF HATCHES. c6 ; .5 - -s 4731;1-