Loading...
HomeMy WebLinkAboutS-3473550 N 0 o! t 3 a w N 0 N 0 Q 0 z a z �a J 6 "x12" CURB I y BELOW WALL–, its #6 ® 12" "(4 eC FF EL 322.50 e D v p D eD D 10 MIL VAPOR BARRIER D -0 D e 2" SAND ABOVE r 1` AND VAPOR BELOW 6" CRUSHED �j� ROCK \� � /\, 2' -0" STRUCTURAL �� BACKFILL / / /', j \// COMPACTED TO 95% / / ASTM D7557 �. \�. \�� \�� \�. \�. \�.\ NATIVE MATERIAL SCARIFY 12" AND RECOMPACT TO 95% SECTION A -A #5 DOWEL 2 – #5 CONT BASE OF WALL - #6 BAR (TYP) SCALE: 1" = V -0" 3' -0" 2, -0" 6, -0" _ _ ROOF TRUSS NOTES: 1. DESIGN ROOF TRUSSES FOR THE FOLLOWING MINIMUM LOADS. GRAVITY LOADS: DEAD LOAD ON TOP CHORD 15 PSF ON BOTTOM CHORD 10 PSF HANGING POINT LOAD ON BOTTOM 2000 LB LIVE LOAD ON TOP CHORD 20 PSF WIND LOAD: AT BASIC WIND SPEED OF 85 MPH NET UPLIFT /DOWN PRESSURE ZONE A –22 PSF /9 PSF NET UPLIFT /DOWN PRESSURE ZONE B –11 PSF /9 PSF NET UPLIFT /DOWN PRESSURE ZONE C –22 PSF /9 PSF SEISMIC LOAD: SEE SHEET S1 ROOF SNOW LOAD: 26 PSF 2. METAL PLATE CONNECTORS: a. PROVIDE METAL CONNECTOR PLATES DESIGNED AND TESTED IN ACCORDANCE WITH TRUSS PLATE INSTITUTE CRITERIA. b. CONNECTOR PLATES SHALL BE 20 –GAUGE STEEL FOR TRUSS T1 & 18 GUAGE STEEL FOR TRUSS T2, ASTM A -446 GRADE C STRUCTURAL, HOT –DIP GALVANIZED, ASTM 525 –G60. C. CODE APPROVED –ICC EVALUATION SERVICE REPORT. d. APPLY CONNECTOR PLATES TO BOTH FACE OF TRUSS BY HYDRAULIC PRESS OR ROLLER SEAT PLATES FIRMLY AGAINST WOOD TRUSS MEMBERS. 3. FOR ALL TRUSS MEMBERS SEE WOOD FRAMING NOTES ON SHEET S1. 4. SUBMIT CALCULATIONS SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER LICENSED IN THE STATE OF WASHINGTON FOR THE DESIGN OF TRUSSES. SUBMIT DRAWINGS OF TRUSSES SHOWING ALL MEMBERS, LAYOUT, DIMENSIONS, AND CONNECTIONS. DEFERRED SUBMITTALS: IN ACCORDANCE NTH 2006 IBC SECTION 106.3.4.2 SUBMITTAL DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATION THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. THE FOLLOWING ITEMS WILL BE DEFINED AS DEFERRED SUBMITTAL ITEMS: 1. FINAL DRAWINGS AND STRUCTURAL CALCULATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES AND CONNECTIONS BETWEEN WOOD TRUSSES AND OTHER STRUCTURAL COMPONENTS. ROTI -'rlILL Rath HiII, LLC Tel425.869.9448 www.rothtiill.com 11130 NE 33rd Place, Suite 200 Bellevue, WA 98004 Kennedy /Jenks Consultants 32001 32nd Avenue South, Suite 100 Federal Way, WA 98001 Ph. 253- 835 -6400 Fax 253- 9523435 2x BLOCKING SIMPSON H10 EA FACE OF WALL 15/32" PLYWOOD SIMPSON A34 EA (TYP) SID 2x BLOCKING—\ 12 15/32" ROOFING PER PLYWOOD ARCH DWGS 6 (TYP) ROOF ROOFING PER TRUSS ARCH DWGS� I 2x4 SIMPSON LUS24 2x10 FASCIA 2x10 FASCIA BEAM DOUBLE 2x8 TOP PLATE BEAM 2 - #5 CONT, BENT INTO ADJACENT WALLS (TYP AT EACH SIDE OF AB) SPLIT FACE CMU WALL WALL 3/4.0 ANCHOR BOLT, 24" SPLIT FACE i CC, W/ 12" EMBED CMU WALL SECTION B -B SCALE: 3/4" = V -0" #6 ®12" T &B EW EL 322.50 g. 0 I N 12" CRUSHED ROCK EXTEND 1' -0" BEYOND EDGE OF SLAB NOTE: PROVIDE 12" MINIMUM DISTANCE FROM EDGE OF CONCRETE FOR ALL SEISMIC ANCHORAGE. GENERATOR SLAB DETAI 1 SCALE: 1/2" = 1' -0" S4 CON SEE EXP SEE CONTROL NOTE: REINFORCING NOT SHOWN. SEE DETAILS ON THIS SHEET AND STANDARD MASONRY SHEET FOR REINFORCING. 6" CRI ROCK 2' -0" BACKF TO 95' D1557 NATIVE SCARIF RECOM NOTES: 1. SEE DWG S -1 FOR REINFORCING STEEL COVER. 2. ALL CMU WALLS SHALL BE FILLED WITH GROUT PER DRAWING S3 AND SPECIFICATION SECTION 10.04220. 2x BLOCKING 12 6 15/32" PLYWOOD (TYP) TRUSS TOP ROOFING PER CHORD ARCH DWGS TRUSS BOT CHORD SIMPSON H10 EA FACE OF 2x10 FASCIA WALL BEAM DOUBLE 2x8 TOP PLATE 2 – #5 CONT, BENT INTO 3/4 "0 ANCHOR BOLT, 24" ADJACENT WALLS (TYP AT CC, W/ 12" EMBED WALL EACH SIDE OF AB) i SECTION C -C SCALE: 3/4" = V -0" SPLIT FACE CMU WALL WALL i SECTION D -D SCALE: 3/4" = V -0" #4 ® 8" HOOPS (TYP) #5 VERT ® EA CORNER (TYP) — CMU PILASTER (2) - #5 DOWEL W/ STANDARD HOOK - (TYP) LAP SPLICE (TYP) SIMPSON A34 ® 24" 12 6 F— ROOF TRUSS (BEYOND) DOUBLE 2x8 TOP PLATE 2 - #5 CONT, BENT INTO ADJACENT WALLS (TYP AT EACH SIDE OF AB) 2" CMU CAP HORIZ REINF CONTINUOUS W/ WALL I #4 HOOP 12" 6" CRUSHED ROCK ���il�i`i `I�I`i`� • • 1 � 1,1, 6" CRUSHED v. vyivi vrvv� • • v tiC� d . ROCK • v v Vii. it�i �i- v v v v' �iT • •- 2'-0" STRUCTURAL /w• C' TO 95% PER ASTM V/ D1557 NATIVE MATERIAL SCARIFY 12" AND RECOMPACT TO 9 TYPICAL WALL SECTION CMU SCREEN WALL DETAIL WALL -WALL DETAIL W 1/2" = i' -0" S4 RECORD DRAWING SCALE: 1/2" = V -0" S4 These Record Dra.Lgs have been prepared bused on information provided by the contractor and others. Kennedy /Jenks Consukants has not verified the accuracy or completeness of infomation provided to them and does not wamm,t the accuracy or completeness of these Record Drawings. Users of these Record Drawings assume all risk of loin resulting from their use. saxrtvm: swc: vmrpu, w.w ,sse 1/2 " =1. -D" namaxwxn,am,ss, ;L CITY OF Er amwm RENTON CPAwn: °XE "b1 DATUM Er t RECORD DRAWING RFB 7/20/1 JMF cnr DUB Planning /Building /Public Works Dept. IF eor or¢ iucn NO. REVISION BY DATE APPR =*Vv"" (2 24" 18" 12" 6" 0 1' 2' 3' 4' oiz i"i i4v; m ✓ax I ;iazasrz SCALE: 12 " =1' -0" 12" 6" 0 1' 2' J/ Z. -. ,. 7, „i.. SCALE: 1 " =1' -0” STONEGATE LIFT STATION REPLACEMENT CONTROL BUILDING SECTIONS AND DETAILS 06 -11 -2010 PILL S5 26 42