Loading...
HomeMy WebLinkAboutS-361603Z U w O a w CL Z Z w X w Ir w w H f� J O O 2 2 a O a CONTROL POINTS POINT NO. NORTHING FASTING ELEV. POINT DESCRIPTION 114 177970.9955 1323451.0356 463.76 PK NAIL WITH ESM CONTROL WASHER 115 178033.9669 1323118.6406 466.25 PK NAIL WITH ESM CONTROL WASHER 116 178031.6592 1322625.8698 454.97 PK NAIL WITH ESM CONTROL WASHER 117 178649.2669 1323116.4961 455.92 PK NAIL WITH ESM CONTROL WASHER 124 178415.0884 1323149.6271 PK NAIL WITH ESM CONTROL WASHER 125 177488.9418 1322445.4194 430.87 FOUND PK NAIL WITH WASHER 126 177296.4351 1322146.4327 468.46 REBAR WITH ESM CONTROL CAP 127 177593.3833 1321808.8615 479.76 PK NAIL WITH ESM CONTROL WASHER 128 177606.4832 1321701.2801 484.37 CASED MONUMENT 129 177632.5339 1321421.6704 482.701 FOUND PK NAIL 130 177627.0217 1321178.4244 476.29 PK NAIL WITH ESM CONTROL WASHER 134 177624.0971 1321176.5039 CASED MONUMENT 135 178612.0993 1323694.1252 PK NAIL WITH ESM CONTROL WASHER 200 177996.0829 1323425.0723 CASED MONUMENT 202 178014.1230 1323136.6633 CASED MONUMENT 203 179319.1028 1323125 -4542 CASED MONUMENT 204 178666.5189 1323131.0497 CASED MONUMENT 300 177770.8310 1322438.1521 444.38 FOUND PK NAIL WITH WASHER 301 177626.2125 1322442.3278 444.88 FOUND PK NAIL WITH WASHER 8303 177902.0006 1 1322515.0699 FOUND PK NAIL SURVEY DATUM: HORIZONTAL DATUM, NAD83(91) WASHINGTON STATE PLANE COORDINATE SYSTEM NORTH ZONE VERTICAL DATUM, NAVD 1988 CITY OF RENTON PUBLISHED BENCH MARKS #1909 CASED MONUMENT WITH LEAD AND TACK AT THE INTERSECTION OF SE 139th PLACE AND 156TH AVENUE SE. ELEVATION = 408.64 #2088 CASE MONUMENT WITH h" BRASS DISC AT THE INTERSECTION SE 142ND PLACE AND 156TH AVENUE SE. ELEVATION = 372.34 CITY OF RENTON PUBLISHED BENCH DESCRIPTIONS ARE REVERSED FOR BENCHMARKS #2088 AND #1909 NOTE: PROPERTY CORNERS, RIGHT -OF -WAY MARKERS, SURVEY MONUMENTS AND FENCES THAT MAY BE REQUIRED TO BE REMOVED OR DISTURBED BY CONSTRUCTION SHALL BE FIRST LOCATED AND REFERENCED BY A SURVEY AND RESTORED IN THEIR ORIGINAL CONDITION AND LOCATION AFTER CONSTRUCTION IS COMPLETED BY A LICENSED PROFESSIONAL SURVEYOR. IF MONUMENTS NEED TO BE RAISED TO NEW GRADE, SAID RAISING SHALL BE IN ACCORDANCE WITH 2007 KING COUNTY STANDARD DETAILS 5 -019 AND 5 -020. ® 81 S339,d CONSULTING ENGINEERS LLC WARNING: mg 0. SOW 210 10 10 IG'�I FBtlelel WeYi WN 96003 Ot6�t wnv ESI 9b <�� THE UTILITY LOCATIONS SHOWN =rng I txn.com arli En9m °6n9 Lane mnerin9 WnE PI°omnq su -aa°e ARE APPROXIMATE ONLY. DEPTH P°Elia W° 1 P,°1« u°na9° -t 1 La9,°a°P° Aro61t..,. UNKNOWN. CALL 1- 800 - 424 -5555. ESM JOB #1655- 001 -011 A PORTION OF SEC 13,14 & 24, TWP 23 N, RGE 5 E, WM, KING CO, WA w Tn W i NO. I Li F1(6 w 135TH STREET w Q (0 19 z b6K 0 U 137TH PLACE Y J-1 -j( ;-J Jrr1JJ I REVISION by ,x cnccrcmAN NZE LL ENE IF NOT ONE INCH EG!£ ACCORgX9LY VEa : xnw 1969 HORIZOW3 WD 19W/1961 DATUM w Q F-1 n _ 8F�JA-RW0JD EFL ARY SCI )0L S.E. STREE 134TH � T rte_ A 136TH S I Hk=F=T 5- 361603 CITY OF RENTON Planning /Building /Public Works Dept. n SCALE: 1 " = 200' 200 100' O 200' 400' CHECKED FOR COMPLIANCE TO CITY ST NDARDS ISSAQUAH SCHOOL DISTRICT SANITARY SEWER EXTENSION SITE SURVEY CONTROL "S-,36 PPLE -SV