Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
R-342634
SECT.18 T.23N. R.5E. W.M. Ir— O co O W bi V) 0 Ln r1r) N- Q Cf) CD a Ld LLJ Cf) 0 Ln V) LLJ J C) r- Q ROSEWATER 1 CLIENTS I PEOPLE I PERFORMANCE 12.-1 THIRD AVENUE, SUITE 1500 16 SE4fT.. WASHIA;TON 98'01 30 3 i DMJM HARRIS I AECOM 10900 NE STH STREET, SUITE 750 BELLEVUE, WASHINGMN 98044 PHONE: (425) 45"OW FAX: (425) 454-OM 14.1 LF 12" CPEP S=6.74% - APPROVED FOR CONSTRUCTION CITY OF RENTON DATE PROFILE SCALE: H: 1" = 20' V: 1 "=1 0' SURVEYED; DESIGNED: SCALE K SMITH R. EDRALIN CHECKED: DNE N1CH M. DE LL1A AT FULL QfJI F ADDENDUM N0. 1 WRE 07/09 KRS C NOT ONE INCH APPRwED: scuE ►uccaRaNGLr NO. REVISION BY I DATE I APPR K. SMFTH VERTICAL• NAW 1988 HORIZONTAL NAD 1983/1991 DATU M 0 CD LLJ Ld (I) 0 L7 V) K) 0 Cn 0 Ld Ld C!) 0 Ln Q V) W z J U d CONSTRUCTION NOTES: O2 REPLACE EXISTING WATER SERVICE LINE TO MAIN (PIPE AND INSTALLATION BY CITY) O3 PROTECT EXISTING WATER METER AND METER BOX REPLACE EXISTING WATER O METER AND METER BOX (BY CITY) INSTALL TRAFFIC RATED COVER O ON METER BOX OPROTECT EXISTING 10" WATER MAIN, COORDINATE WITH RENTON WATER DEPARTMENT TO SHUT OFF MAIN DURING CONSTRUCTION CONNECT EXISTING STORM LINE TO NEW CATCH BASIN, VERIFY EXISTING PIPE DEPTH PRIOR TO CONSTRUCTION ABANDON AND FILL EXISTING STORM DRAIN PIPE 9 PROTECT GAS LINE (COORDINATE WITH PSE) iC COORDINATE WITH PSE TO RELOCATE OR PROTECT EXISTING UTILITY POLE 11 CONSTRUCT 8" SANITARY SEWER THROUGH MANHOLE IN 14" STEEL CASING. SEE DETAIL, DWG SD06 15 GAS MAIN RELOCATION (BY PSE) 20 SEE DWG SD04-SD05 FOR PROFILE 23 PROTECT OR RELOCATE EXISTING SANITARY SEWER SERVICE 25 ADJUST MANHOLE 2� CONNECT NEW SANITARY SEWER LINE TO EXISTING SANITARY SEWER MANHOLE AND RECHANNEL 28 CORE DRILL AND CONNECT TO EXISTING STORM DRAIN STRUCTURE 32 ABANDON STORM DRAIN MANHOLE 35 WARNING -UNKNOWN UTILITY APPEARS TO PASS THROUGH EXISTING MANHOLE. VERIFY LOCATION AND COORDINATE RELOCATION PRIOR TO REMOVING MANHOLE. CITY OF RENTON Public Works Dept. FED AID NO.: ARRA-0167(044) 36 REMOVE EXISTING CATCH BASIN 3� REMOVE EXISTING STORM DRAIN PIPE* 38 REMOVE ABANDONED SANITARY SEWER* 39 REMOVE EXISTING MANHOLE* 41 ADJUST VALVE BOX 44 BURIED TELEPHONE (BT) SHOWN MAY NOT EXIST. TELEPHONE IS OVERHEAD, VERIFY PRIOR TO CONSTRUCTION. 46 FIELD LOCATE CB TO INTERCEPT EXISTING STORM DRAIN PIPE FROM BUILDING 50 PROTECT EXISTING FIRE HYDRANT *UTILITY REMOVALS PAID FOR BY "REMOVAL OF STRUCTURE AND OBSTRUCTION". RECORD DRAWINGS SEPTEMBER 2010 BASED ON CONTRACTOR'S RECORDS 20 0 20 40 L.wli- SCALE IN FEET RAINIER AVE S (SR 167) IMPROVEMENTS PROJECT FlELDBOOK: PHASE 1 PAGE SHATTUCK AVE S STORMWATER BYPASS AWIN.' STORM DRAINAGE & UTILITIES SD02 PLAN AND PROFILE STA 13+50 TO 17+50 SHEET: . :, A0©Umm©u