HomeMy WebLinkAboutT-163002CONSTRUCTION NOTES
S.W! 7th STREET _ _ +00 - _5 4*22
- - R /W-*"4 - -- - -
INSTALL GALV. STEEL SIGNAL POLE TYPE B -I WITH 30' MAST ARM, TWO VEHICLE SIGNAL LEADS, TWO PEDESTRIAN SIGNAL HEADS, AND TWO PEDESTRIAN PUSH -
1 I /2"
�-,f'
BUTTONS. INSTALL 250 WATT SODIUM VAPOR LUMINARE WITH PHOTO -CELL. INSTALL SIGNAL POLE FOLI- NDATION.
`MIRING
D
INSTALL GALV. STEEL SIGNAL POLE TYPE D-I W/ 35- MASTARM, 3 VEH. SIGNAL HDS,2 PED SIGNAL HDS, ,B 2 PED PUSHBUTTONS. INSTALL 250 W S LUMINARE
RUN NO
`-✓
W/ PHOTO -CELL, INSTALL SIGNAL POLE FOUNDATION,
(4 -5 /C, 1-3/C,2-2/C),(2#8)
3
INS T ALL GALV. STEEL SIGNAL POLE TYPE C -1 W130' MAST ARM, 2 VEH, SIGNAL HDS, 2 PED, SIGNAL HDS, a 2 PED PUSHBUTTONS. INSTALL 250 W S V, LUMINARE
3",2 ", 11/2"
(7- 5/C,1- 3/C),(5 - 2/C),(4 #8)
W/ PHOTO -CELL, INSTALL SIGNAL POLE FOUNDATION,
(7 -5 /C, 1 -3 /C, 5 - 2/C),(7- 5/C,2- 3/C,3- 2/C),(6 -PAIR)
4
INSTALL GALV, STEEL SIGNAL POLE TYPE E -I W/ 40' MAST ARM, 3 VEH, SIGNAL HDS, 2 PED. SIGNAL. 'LIDS, ?a 2 PED. PUSHBUTTONS. INSTALL 250W Sy LUMINARE
q
BREAKER
W/ PHOTO -CELL, INSTALL SIGNAL POLE FOUNDATION.
SAWCUT
2 # 12
INSTALL CONTROLLER AND CONTROLLER CABINET TYPE P-1 ON RAISED CONCRETE FOUNDATION.
R
R
INSTALL TYPE "B" CONCRETE JUNCTION BOX.
wl
7
INSTALL TYPE "C" CONCRETE JUNCTION BOX.
Q
Y
INSTALL 6'x6' INDUCTION LOOP DETECTOR WITH THREE TURNS OF WIRE.
i W
3
INSTALL FIRE PRE - EMPTION DETECTOR. f
6#12
ICJ
INSTALL CONDUIT INTO EXISTING UNDERGROUND VAULT, SEAL WITH GROUT. COIL SUFFICIENT AMOUNT OF WIRE FOR CONNECTION BY POWER PERSONNEL -
Q
8# 12
"LEFT
5
11
INSTALL 24" x 30" SIGN R 10-10 TURN SIGNAL" ON MASTARM ADJACENT TO LEFT TURN SIGNAL HEAD.
6
12
INSTALL 6 -PAIR INTERCONNECT CABLE INTO EXISTING CONTROLLER CABINET AT 7th ST 81 RAINIER AVE. CONNECT WIRING AS DIRECTED BY ENGINEER. 1
l
INSTALL STREET LIGHT WIRE INTO EXISTING CONTACTOR CABINET AT 7TH ST 8 RAINIER AVE. CONNECT WIRING AS DIRECTED BY ENGINEER. t
f 4
I4
INSTALL CONDUIT INTO EXISTING JUNCTION BOX. 7
7
11/2"
2#8
R
GENERAL NOTES S
11/2", 11/2"
(6- PAIR),(2 #8)
B
R
R
R
TYPE A ELECTRICAL SERVICE
4
I.
AS A PART OF THIS PLAN, REFERENCE SHALL BE MADE TO THE SPECIAL PROVISIONS, DETAILS, WASH. STATE D.O.T. STD. PLANS 81 SPECS., a NAT -L ELEC. CODE. /191 !
--
2
2.
ALL POLE LOCATIONS SUBJECT TO THE APPROVAL OF THE TRAFFIC ENGINEER. 5
d 4,5
R R
3,
NO UNDERGROUND OR IN -LINE SPLICES SHALL BE PERMITTED UNLESS OTHERWISE NOTED. r
R
p
4
A SEPERATE GROUNDING SYSTEM SHALL BE PROVIDED CONSISTING OF A NO.8 AWG WIRE CONNECTING THE GROUND WIRETERMINALAT THE BASE OF 7 ^
EACH SIGNAL POLE TO THE NEUTRAL BAR IN THE CONTROLLER CABINET. APPROVED UNDERGROUND SPLICES IN THE GROUND CIRCUITARE PERMITTED. { 77
t
R
R
R
R
R
R
R
R
R
_ - -- _ 13
R
I -
S.W! 7th STREET _ _ +00 - _5 4*22
- - R /W-*"4 - -- - -
11/2", 1 1/2"
(1 -2 /C, 6- PAIR),(2#f8)
1 I /2"
1201 V AC
2 ", I 112'
`MIRING
SCHEDULE
(3 -5 /C, I- 3/C),(3- 2/C,6-PAIR),(2 #8)
RUN NO
CONDUIT SIZE
WIRE SIZE
(4 -5 /C, 1-3/C,2-2/C),(2#8)
2 ", 1 1/2"
SINGLE 35 A
3",2 ", 11/2"
(7- 5/C,1- 3/C),(5 - 2/C),(4 #8)
31/2 ",3 ", 11/2"
(7 -5 /C, 1 -3 /C, 5 - 2/C),(7- 5/C,2- 3/C,3- 2/C),(6 -PAIR)
31/2",3",11/2",2"
(7-5/C, 1-3/C, 5- 2/C),(7- 5 /C,2 -3 /C, 4- 2 /C),(6- PAIR),(EMPTY)
11/2"
BREAKER
I
SAWCUT
2 # 12
Y
R
R
R
R
2
SAWCUT
4# 12
Y
G
TO CONTROL
3
SAWCUT
6#12
EQUIPMENT
4
SAWCUT --
8# 12
R
5
1°
4#12
NOTE: BREAKER TO BE LOCATED WITHIN
Y
Y
CONTROLLER CABINET.
6
1"
8#12
Y
7
11/2"
2#8
R
8
11/2", 11/2"
(6- PAIR),(2 #8)
R
R
R
R
TYPE A ELECTRICAL SERVICE
4
1 1/2"
1- 2/C
--
11/2", 1 1/2"
(1 -2 /C, 6- PAIR),(2#f8)
1 I /2"
2 -2 /C
2 ", I 112'
(3 -5/C, 1- 3/C),(2 #8)
'
2 ,2'' ,11/2' '
(3 -5 /C, I- 3/C),(3- 2/C,6-PAIR),(2 #8)
2 ", 11/2"
(4 -5 /C, 1- 3/1),(2 #8)
3 ", 1 1/2"
(4 -5 /C, 1-3/C,2-2/C),(2#8)
2 ", 1 1/2"
(3- 5/C),(2 #8)
3",2 ", 11/2"
(7- 5/C,1- 3/C),(5 - 2/C),(4 #8)
31/2 ",3 ", 11/2"
(7 -5 /C, 1 -3 /C, 5 - 2/C),(7- 5/C,2- 3/C,3- 2/C),(6 -PAIR)
31/2",3",11/2",2"
(7-5/C, 1-3/C, 5- 2/C),(7- 5 /C,2 -3 /C, 4- 2 /C),(6- PAIR),(EMPTY)
11/2"
6 -PAIR
9
2 I
4 4 5
L�J1
IN
! I
I "
I
it
4
n
I
1 r.
R 4'.
i9
SIGNAL SEQUENCE CHART
1
_
0 1 +5
CHANGE TO
stn t+p aro
- N N V
to W51 Ws
0 I +6
CHANGE TO
, h + tD m
t N sV -T J
I& Ws, M is rs
0 2 +5
CHANGE TO
in cD l>, *o jj
' + N d Q
t9 t9 to tL
3
02+6
4 +8
CHANGE TO
� in Ra Ul cfl
is Ws m is
c=n
J
CHANGE TO
t9
10
*
in
N
>ea
m
_.i
tL
1,2
R R
R
R R
R
G
Y
Y
G
R
Y
R
R
R
R
R
R
G
Y
G
R
R
Y
R
R
R
R
R
R
R
3
Y
Y
Y
Y
Y
Y
Y
R
R
R
R
RJR
R
R
R
R
R
R
R
R
R
R
R
R
R
d 4,5
R R
R
R R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
RJR
G
Y
Y
Y
Y
Y
R
6,7
R R 'R
R R
'R
R
R
R
RJR
R
G
Y
Y
G
Y
Y
G
Y
Y
Y
Y
R
R
R
R
R
R
R
8
Y
Y'Y
Y
R
R
R
R
I R
R
Y
Y
Y
Y
R
R
R
R
R
R
R
R
R
R
RJR
R
9,10
R R
R
R'
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
G
Y
'Y
Y
Y
Y
R
11,12
D
F
F
DWMpW
WI
F
F
)WDWDWDWDN)%D%
DW
DE
13,14
DW
DW
DW
DW
W
DW
D
F
D
D
DE
15,16
DW
'
DW
D
MOW
F
DW
DW
F
F
D
F
DW
D
DW
DE
17,18
DW I�
D
D
DW
DW
D
DW
D
DW
OW
DW
E
D
DE
SEMIENCE
NOTES=
I. EASTBOUND EMERGENCY PRE- EMPTION R= RED
Imm
SHALL SEQUENCE TO 02+ 5.
2 WESTBOUND EMERGENCY PRE-EMPTION
SHALL SEQUENCE TO 01 + 6.
3. NORTH a SOUTH BOUND EMERGENCY
PRE- EMPTION SHALL SEQUENCE
TO 0 4 +8. A
R/. - -
SIGNAL HEADS
Y = YELLOW
G = GREEN
F= WALK, FLASH DONT WALK
DW =DONT WALK
DE = DE- ENERGIZE
4{OG - - -9+52
_(i - -
01+6
�1
10 i 6
r 2 ! R 128 R 12„
i 4{ T
1 8 s I 12 7 �J 1;2 u
I
12° G 12°
I�
I 3,8 1,2,4,5x6,7,9,10 _A
I T
• I � �
01+5
11,12.13.14,15,16,17,18
SIGNAL NOTES:
1-
�s L ALL YEtI. HEADS SHALL HAVE TUNNEL VISORS - -I•
AND SQUARE DOORS.
2-ALL VEH_ HEADS SHALL USE MOUNTING TYPE L.
3. ALL PED. HEADS SHALL BE NEON WITH EGG CRATE
2+5
VISORS- PED HEADS SHALL USE L O C H N E R'
TYPE AMOUNTING.
0,� n H. W. LOCHNER, INC., 301-116th AVENUE. S.E..SUITE 390. BELLEVUE. wASr+iNG DON 98004
F(r AlAlK
SCALE IN FEET2
20 10 0 20 40 60 80
NO. REVISION BY APPR. DATE
lltl4
PHASING
2 +6 04 +8
CITY OF'RENTON
DEPARTMENT OF PUBLIC WORKS
SW 7th ST. & HARDIE AVE. SW
SIGNALIZATION PLAN
SIGNED CJS DXTE 12-14-81 PILE NO.
AWN CJS
I
ECKED SCALE C-20 FIELD soon aA��
?ROVED SHEET 2 OF_ 4