HomeMy WebLinkAboutT-173501NE 19th ST. LL.I zj- W 0 W co CIRCUIT ^ (J �YN ° (?(_." �' l.5" C 3 °6 1,3 1- 4- 2, 4 5 - 7 —�U NE /7n ST. LIGH TING PLAN Q❑ 'CUT -OFF TYPE STREETLIGHT - 175 WATT, 240 VOLT ® CONCRETE HANDHOLE - WSDOI Ty ?,z .) -20,1 PEDESTAL PANEL PAD- MOUNTED TRANSFORMER (BY PSPL) - -- - IV PVC 2 #8, 1 #10 GRND, UTILIZE PSPL '.TRENCH WHERE POSSIBLE, 1" PVC 2 #o, 1 #10 GRND. PROVIDE NEW ,TRENCH WITH 24" MINIMUM COVER, - NOTES: 1- PROVIDE A HANDHOLE AT ALL LUMINAIRE LOCATIONS & WHERE SHOWN, PROVIDE ADDITIONAL HANDHOLES AS NECESSARY FOR CONDUCTOR INSTALLATION, 2- ALL CONDUIT TO BE SCHEDULE 40 EXCEPT STREET CROSSINGS, STREET CROSSINGS TO BE SCHEDULE 80, CONDUCTOR INSULATION TO BE TYPE TM 3- PROVIDE PHOTO -CELL & TWIST LOCK RECEPTACLE ON LUMINAIRE #2, EXTEND 3 #10 CONDUCTORS TO PEDESTAL PANEL & CONNECT AS SHOWN, 4- ALL WORK NOT OTHERWISE SPECIFIED SHALL BE IN ACCORD WITH WSDOT STANDARD SPECIFICATIONS L C! ;111 JA' : E: CUT -OFF COBRA HEAD WITH CLEAR, FLAT, ,HEAT AND IMPACT _ RESISTING GLASS LENS, IES -ANSI SHORT, TYPE III CUT OFF DISTRIBUTION: 175 �'11ATT, 240 VOLT REACTOR NORMAL POl-;ER FACTOR BALLAST. GE TYPE N-25OR CUTOFF, PROVIDE PHOTO CELL AND RECEPTACLE ON UNIT S,OIrN. LAMP: H39KC- 175 /DX STA �DARD: ROUND, TAPERED, PRE- 8 METERS STRESSED CONCRETE ANCHOR BASE WITH 1," TAPERED ELLIPTICAL ALUMINUM ARM. STANDARD AC:GREGATE, GREY CEMENT" - EXPOSED FINISH AND CLEAR ACRYLIC SEALCOAT, CENTRECON I'f'3R-8- AE4-113 SET BACK - FACE OF STANDARD TO FACE OF F] URB. INSTALL ANCHOR BASE 6" - -- T ^� I- J °-36 -- BELOW GRADE. FINISH AREA CUR8$TREET TO MATCH GRADE, =e -�-- —''-� T- 60 i;: = CONDUI T NOTE: A ,I -20,1 HANDHOLE IS REQUIRED {4-I AT EACH STANDARD, STANDARD LUMINAIRE DETAIL NO SCALE WEATHERPROOF PAD MOUNTED $ -- PEDESTAL PANEL WITH COMPONENTS _.., AS NOTED: 12 GAUGE MINIMUM ! NQ - - - - -- ,WITH Si OR I PRE - GALVANIZED SHEET STEEL, , WELDED SEAM CONSTRUCTION: I RS & COV:,t I - DOORS WITH CONCEALED HINGES 46" In krNr, RaR AT LEFT, PADLOCKABLE 3 POINT -- LOAD CENTER COMPRESSION LATCHES PLUS B I I LOCKING BAR, REMOVABLE L--- INTERIOR MOUNTING PAN CONTAINING COMPONENTS AS -- - LISTED, FINISH: PRE - TREATED - -- LIGHTING INSIDE & OUT, INTERIOR TO BE CO TACT,ORS WHITE BAKED ENAMEL, EXTERIOR L== =TES SWITCH i TO BE DARK GREEN BAKED ENAMEL: 2" --- RECEPTACLE BOTTOM OPEN WITH 2" FLANGES 3" TURNED INWARD ALL AROUND: o, d „,•4, ,rte Ern— o �rr;e _ SKYLINE ELECTRIC #33590 •4 II d II II 24" INCOMING & OUTGOING CONDUITS AS REQUIRED FRONT VIEW SIDE VIEW✓ PEDES TAL PANEL DE TA ILS NO SCALE /7345 JD-21 LIGHTING ENGINEERS ' 1840-130th N. E. SUITE 7 BE T�VI LLEVUUE WASHINGTOpN� 98005 + 886.2196 FOR ROAD &BRIDGE CONSTRUCTION. /' FIRST LINE INVESTMENTS A Dfl.PI�RC'VED ��' ' 1 '- . DOLE: "_ APPflOV¢D BY: PUBLIC WORKS DIRECTOR 9 DATE o`er �`" "y 9_J- wa ¢Y .; r DATE: 9-19-791 flcvlDCD W SIERRA HEIGHTS DIV l mi �Jn`NL�"G STREET LIGHTING ­w1 R DS K�l 'T n,21Cr; ^ACE -— -�,oA: SPACE 0,21C4J O 'NT I1 PAN -L N. PEDE.STA! 1'�AMP LTCNr _ E '2 TO STREET LIGHTS -OTAL. LOAD 1.2 KW 11.2 A. ll� / I IE D111�GPAI' ;, NOTES: 1- PROVIDE A HANDHOLE AT ALL LUMINAIRE LOCATIONS & WHERE SHOWN, PROVIDE ADDITIONAL HANDHOLES AS NECESSARY FOR CONDUCTOR INSTALLATION, 2- ALL CONDUIT TO BE SCHEDULE 40 EXCEPT STREET CROSSINGS, STREET CROSSINGS TO BE SCHEDULE 80, CONDUCTOR INSULATION TO BE TYPE TM 3- PROVIDE PHOTO -CELL & TWIST LOCK RECEPTACLE ON LUMINAIRE #2, EXTEND 3 #10 CONDUCTORS TO PEDESTAL PANEL & CONNECT AS SHOWN, 4- ALL WORK NOT OTHERWISE SPECIFIED SHALL BE IN ACCORD WITH WSDOT STANDARD SPECIFICATIONS L C! ;111 JA' : E: CUT -OFF COBRA HEAD WITH CLEAR, FLAT, ,HEAT AND IMPACT _ RESISTING GLASS LENS, IES -ANSI SHORT, TYPE III CUT OFF DISTRIBUTION: 175 �'11ATT, 240 VOLT REACTOR NORMAL POl-;ER FACTOR BALLAST. GE TYPE N-25OR CUTOFF, PROVIDE PHOTO CELL AND RECEPTACLE ON UNIT S,OIrN. LAMP: H39KC- 175 /DX STA �DARD: ROUND, TAPERED, PRE- 8 METERS STRESSED CONCRETE ANCHOR BASE WITH 1," TAPERED ELLIPTICAL ALUMINUM ARM. STANDARD AC:GREGATE, GREY CEMENT" - EXPOSED FINISH AND CLEAR ACRYLIC SEALCOAT, CENTRECON I'f'3R-8- AE4-113 SET BACK - FACE OF STANDARD TO FACE OF F] URB. INSTALL ANCHOR BASE 6" - -- T ^� I- J °-36 -- BELOW GRADE. FINISH AREA CUR8$TREET TO MATCH GRADE, =e -�-- —''-� T- 60 i;: = CONDUI T NOTE: A ,I -20,1 HANDHOLE IS REQUIRED {4-I AT EACH STANDARD, STANDARD LUMINAIRE DETAIL NO SCALE WEATHERPROOF PAD MOUNTED $ -- PEDESTAL PANEL WITH COMPONENTS _.., AS NOTED: 12 GAUGE MINIMUM ! NQ - - - - -- ,WITH Si OR I PRE - GALVANIZED SHEET STEEL, , WELDED SEAM CONSTRUCTION: I RS & COV:,t I - DOORS WITH CONCEALED HINGES 46" In krNr, RaR AT LEFT, PADLOCKABLE 3 POINT -- LOAD CENTER COMPRESSION LATCHES PLUS B I I LOCKING BAR, REMOVABLE L--- INTERIOR MOUNTING PAN CONTAINING COMPONENTS AS -- - LISTED, FINISH: PRE - TREATED - -- LIGHTING INSIDE & OUT, INTERIOR TO BE CO TACT,ORS WHITE BAKED ENAMEL, EXTERIOR L== =TES SWITCH i TO BE DARK GREEN BAKED ENAMEL: 2" --- RECEPTACLE BOTTOM OPEN WITH 2" FLANGES 3" TURNED INWARD ALL AROUND: o, d „,•4, ,rte Ern— o �rr;e _ SKYLINE ELECTRIC #33590 •4 II d II II 24" INCOMING & OUTGOING CONDUITS AS REQUIRED FRONT VIEW SIDE VIEW✓ PEDES TAL PANEL DE TA ILS NO SCALE /7345 JD-21 LIGHTING ENGINEERS ' 1840-130th N. E. SUITE 7 BE T�VI LLEVUUE WASHINGTOpN� 98005 + 886.2196 FOR ROAD &BRIDGE CONSTRUCTION. /' FIRST LINE INVESTMENTS A Dfl.PI�RC'VED ��' ' 1 '- . DOLE: "_ APPflOV¢D BY: PUBLIC WORKS DIRECTOR 9 DATE o`er �`" "y 9_J- wa ¢Y .; r DATE: 9-19-791 flcvlDCD W SIERRA HEIGHTS DIV l mi �Jn`NL�"G STREET LIGHTING ­w1 R