HomeMy WebLinkAboutT-1781041 I
I
. -t
O
O. _
M - i
N
( 8 ' USE EXISTING CONDUIT UNDER RAILROAD TRACKS. CONDUIT IS
���J// STUBBED AND CAPPED UNDER ROADWAY AT POINTS OF INTERSECTION
OF CURB LINES ON N.W. AND S.W. CORNERS OF INTERSECTION.
PROVIDE JUNCTION BOXES AT THESE CORNERS AND EXTEND CONDUIT
INTO JUNCTION BOXES. SEE SPECIAL PROVISIONS.
��J J JUNCTION BOX TO BE PRUVI DED AND INSTALLED BY OTHERS. SEE
SPECIAL PROVISIONS.
11 PROVIDE AND INSTALL DESIGN B JUNCTION BOX TO BE USED FOR
FUTURE TYPE A SERVICE. SEE SPECIAL PROVISIONS, DETAIL SHEET
AND STANDARD PLAN J -20.
7 +85
I
58
O I F
F � 0 i ++ 57
'RtDX ) � ap
9 I
0
I I
57
I
I
57.1
SCALE IPl FEET
.. � _ }
i�v ^J;�J :16
I
I
9 +64
42
J (
t
t
- - -`
--�
51\
� M
(V
SCANNED MAR 2 8 2�3 ®�
CONSTRUCTION NOTES
O
FOUNDATION, STREET LIGHT STANDARD, AND LUMINAIRES TO BE
PROVIDED, ASSEMBLED, AND INSTALLED BY OTHERS AS PART OF
O1
CONSTRUCT FOUNDATION AND PROVIDE AND INSTALL [•U>rSTER CONTACTOR
CBD PROJECT. PROVIDE AND INSTALL WIRES FOR 120 VOLT INCAN-
WITH MODIFIED TYPE D SERVICE IN TYPE A CABINET 3' FROM FACE
DESCENT T_SGHTING INTO BASE OF POLE AND CONNECT TO 120 VOLT
OF CURB. SEE SPECIAL PROVISIONS, DETAIL SHEET, AND STANDARD
CIRCUIT AT THE EXISTING JUNCTION BLOCK IN THE BASE OF THE
PI•ANS J -lSc, J -1Bd, AND J -lSe.
POLE. PROVIDE I1ND INSTALL WIRES FOR 290 VOLT SODIUM VAPOR
INTO BASE OF POLE AND SPLICE TO 240 VOLT CIRCUIT
OLIGHTING
�
SEE SOUTH 4TH STREET - HURNETT AVENUE INTERSECTION SIGNALI-
WHICH FjI LL HE TERMINATED IN BASE OF POLE BY CBD PROJECT CON -
2ATZON PLAN.
TRACTOR. PROVIDE AND USE QUICK DISCONNECT KITS TO MAKE SPLICE.
SEE SPECIAL PROVISIONS.
/�
( 3 )
PROVIDE AND INSTALL CONCRETE JUNCTION BOX, DESIGN C.
�J
SE8 SPECIAL PROVISIONS AND STANDARD PLAN J -20.
4O
CONSTRUCT 3'X3'X7' FOUNDATION AND INSTALL TYPE II STREET
LIGHT STANDARD A.ND 400 WATT SODIUM VAPOR LUMINAIRE PROVIDED
BY THE CITY. PROVIDE AND INSTALL ADAPTOR PLATE. SEE SPECIAL
PROVISIONS, DETAIL SHEET, AND STANDARD PLAN J -23.
SO
CONSTRUCT TYPE C FOUNDATION. ZNS2ALL TYPE III OR TYPE IV
C
C
STREET LIGHT STANDARD AND 400 WATT SODIUM VAPOR LUMINAI RE
+
�
(TYPE IV ONLY) ALL TO BE PROVIDED BY THE CITY. PROVIDE,
ASSEMBLE AND INSTALL LOW LEVEL MOUNTED LIGHTS. SEE SPECIAL
II
PROVISIONS AND DETAIL SHEET.
�
/�
( 6 )
CONDUIT AND WIRE FOR 120 VOLT INCANDESCENT LIGHTING AND FOR
\�
240 VOLT SODIUM VAPOR LIGHTING TO BE FROVIDED AND INSTALLED
BY OTHERS.
dam'
�"
I [ N
I
�
I ®� P. S_P. EI L. VAULT
�� -3 -�0 SERVICE WIRE
+ 2 22 %1
�
i.�
1 I
I
. -t
O
O. _
M - i
N
( 8 ' USE EXISTING CONDUIT UNDER RAILROAD TRACKS. CONDUIT IS
���J// STUBBED AND CAPPED UNDER ROADWAY AT POINTS OF INTERSECTION
OF CURB LINES ON N.W. AND S.W. CORNERS OF INTERSECTION.
PROVIDE JUNCTION BOXES AT THESE CORNERS AND EXTEND CONDUIT
INTO JUNCTION BOXES. SEE SPECIAL PROVISIONS.
��J J JUNCTION BOX TO BE PRUVI DED AND INSTALLED BY OTHERS. SEE
SPECIAL PROVISIONS.
11 PROVIDE AND INSTALL DESIGN B JUNCTION BOX TO BE USED FOR
FUTURE TYPE A SERVICE. SEE SPECIAL PROVISIONS, DETAIL SHEET
AND STANDARD PLAN J -20.
7 +85
I
58
O I F
F � 0 i ++ 57
'RtDX ) � ap
9 I
0
I I
57
I
I
57.1
SCALE IPl FEET
.. � _ }
i�v ^J;�J :16
I
I
9 +64
42
J (
t
t
- - -`
--�
51\
� M
(V
SCANNED MAR 2 8 2�3 ®�