HomeMy WebLinkAboutT-185202c7ECTSom 9, T. 23 N., P. 5 E., W. M.
a
s
x y I
i
Nil
b I l y I rN
do � NE 8 - S7•
_414 .I j
�
e/eelnc ser✓ice from ae 'o rrf PP.(IVNK)
Canl/ncfar Jo eonsfrncf 01-1i;er an ,0 w ,-Pie
and provide secessory ronduif w /ie o%e
u"' hardwore /a/- 0S,0 el crew Ja make
J
canoecf /aa Jo power source
I Carlfroc }6r }a COVSfrOCf Condaif fa xirace
m6ise} P✓ifhaW infermedv }e sfrucfure
,vs1v // ahobce // mr I � I
I bre¢FsJ ondpra✓ide (3) t2 1W11cie,7t
}bis /u/nmaire I I A more canneefions.
�r r
Y
l
°' /9hJ - - I I tfure slieet rry'bJ msotit)
- I I
Junction 6ax hofh ends
-. -— - _ty/z *B Conduc %ra - \`3 m -_ _..._ __- - ---q /af Z4 +8767
Alf 7 rM Cr. NBB 48'34 '4Y
o
N V
I
Xp1{,�of ,I ,
`,I W ,y
Io .II
x0'1 I
I II
b�
II
I �
0
—4, 100 Watt H.P.S. Luminaire mounted at 25 foot height with 6 foot arm on j
aluminum davit style light pole.
PVC Conduit Schedule 40
e PVC Conduit Schedule 80
® Junction Box type B
Street lighting service cabinet
WIRING SCHEMATIC
TYPE =1 SERVICE 120/ 240 VOLT
r
z7bss•r (
(/6ZT /CALLy
MAIN AFtE II
2 Po 2y.o
20�
vor_T
p — e
�a
I►— T —y, <
.i
NEAREST
TEST jq
I!II.Y�i
SWITCH
--II r
c -4 C,
!' -' I
4 I
1-
T'nEET ::GATING
.'.NTAC -CR-
�
}A/STALLDECAL N(1MBERS
z7bss•r (
(/6ZT /CALLy
v
,S IRING CCCOLE TOGnCLNC
PHOTO-CF! L
ROD
--' MOUN-ED CN
A. W!'1TE i•ACK77 INE'J7RAL)
NEAREST
S.BLACK �ACKE7(L,tiE)
LUMINA`nE
C. GREEN JACKET (CRCUNT)
3
D. RED JACKET (LOAD)
E. GREEN CR EARE CCFFER(GRCUND)
cSERV/CE CA8 /NET
M
O O o
o
O 0
0
0
OOA PANEL N/
CH .REAMERS
IS RED'D
I`MALE PEMALE
DShmu
'E CELL TEnMINAL
'TRW
IACEWAY WITH
IEMIVABLE COVER
rEST SWITCH
ML RECEPTACLE
NGHTING CONTACTOR-9 flE.'0
SERVICE FEEDERS
1 Trt nl atNVIUt GAbINtl DATE:12 /20/88
4 -ry
I
b
`41
I
V /C /N/ 7- Y A44P
.v:•en
s'.•x.
.�ix WA.cx cxir
' \ ALLOY aoti•Tc
oLr
-soY.x +olxT
. WE• 4a
/TU4CO A+V M. Fo e't
...U.. {INIiM -Tt SO
5/16" GALV. STEEL
COVER PLATE I _
(Clal.'.CND PATTERN? _
i
" � I
A ( BI
A !I 3
�y E
�-t6 GALV u:_LDED WIRE LOOP
GALV, STEEL FRAME ANCHORED tN PLACE
IDIAt.:GND PATTER,}
tl di
T
SE ^.TION A -A r SECTION 3-3
W70".
1x "'oic OA ]TN / I/t•OF icLT
xYTx aNDIWAt' .... \ ctavf Flxlin[p
Ig x;x"x�ix oni
rai ici "Axo .: . wx�
.... t ,
t� T. LD •{ DETAIL
T
count xi.i. Ij- ----}- SHEET
NDARD 25' DAVIT POLE 41-4.
DETAIL SHEET
Nv//eces TAa� }
}A/STALLDECAL N(1MBERS
z7bss•r (
(/6ZT /CALLy
/NMYN�Nr//EQ
Sa•a¢Aao"r N
NUPtIBF+P /GV6 E.E'OMPLES
3
L£r7£R S
SUr /XEO LZT7E.Q o
oREF/X£O
• e
err, owvea P2L_. X
11A T
z -I
T z
+
\ \
\ E4r/LC rX20
j. F
FcaYF�
AalvY /E1Y
57W, KcT LJGffT STANDARD /r5
DECAL AJU,y3ER1r✓G SYSTEM
TYPICAL LIGHT SASE AND JUNCTION sox 7- /� /G%�L L/SNT /NG VNV6P_(5R0L1N,0 SYSTEM
LOCATION
R/W LINE
-- SIDEWALK
" — CURB
— - IRDWY, rE ii TO LUN, //✓A /Rc
,Q\t/UNLT /ON .BOX FUSc X/TS' y-Mj //
CURB OU /GT.0 /SLONNELT I GRF /NNOLE
I II � /° gMPr NL1Nc FUSc
�!�- - - - -- - -- -ti- - =SIDEWALK
�PGFG //5W=7 -
_ FOUAOAT /UN TO
i� -- R /WLINE SPL/Lc/l /TS 6cLEYCL{y /TN
411N L-E.:R EFGXy Sf" ✓Lc' GROUND GUG`�1I I TOP JFS /OcW.4LK
CLEARANCE FROM DRIVEWAY ww /Re RUNS 77/40 r7
_l�l UNO:�,avGE.SaSE - - \ \GGII Ilia \
TYPICAL PLAN VIEW rPo
B EARE i c1lII = I I I
H 25' 30' 3� 40' G�PPEK °' =T II it
6RGUN•0 /Yi,Z: GROUNp
SL 18'3 °123'3 "263' 33'3" — LLAMP II II
T .188 .188 .2(9 .219 � it II
II ¢.
(5 /ZE.O AS 040 II Il
TAPERED ALUM. POLE O 2 LY571EN II
V -♦- REOUr.Pr.J') SYSTEM L c J
.'T' WALL ALLOY 6063 -T6 U NTat/G TYS7 -Zg
SA - IN GROUND FINISH •H .� G42NTAGTO,e
HANDHOLE 4'x 6' q 3•So. G.P O /F.
OPENING W /COVER B 2104 \ C •SL
S.S. SCREWS. r �I� S•+ 8. COP /GREY£
iGroYnd lug IOVe g
I „U �G•�p FGUNOAT /ON
` -rslae vale � GRauNa QO,a
f �
rrEDCn IocDII00
net t0 stole .
TYPICAL STREET CROSS SECTION
e>_v 3 - 17 -ev DETAIL SHEET L- ,q� /A /LSf1EET
GENERAL NOTES
i. Approximate locatlons of existing utilities have been obtained from available records
and are shown for convenience. The contractor shall be responsible for verifying the
location of all existing utilities whether shown or not. The contractor shall call
the Utility Locator Service, 1- 800 - 424 -5555, five working days prior to any
construction.
2. It is the responsibility of the contractor to verify what permits have been secured
if any) and to obtain and possess all required permits prior to commencing
construction.
3. The contractor shall take all necessary precautions for the safety of employees on
the project and shall comply with all applicable provisions of Federal, State, and
Municipal safety laws and building codes. He shall erect and properly maintain, at
all times, as required by the conditions and progress of the work, all necessary
safeguards for protection of workmen and the public; shall post danger signs warning
against known or unusual hazards; and he shall designate a responsible member of his
organization on the construction site whose duty shall be the prevention of
accidents.
4. All work shall be In accordance with the project specifications and these plans.
5. The locations of features and existing utilities are approximate and shall be
verified in the field by the contractor.
6. The contractor shall notify all utilities regarding their facilities located within
the project limits 48 hours prior to commencing work and shall coordinate his work
with those utilities. The contractor shall be responsible for any damage to
existing utilities and shall notify the affected utility and the City immediately
upon damage.
7. It is the contractor's responsibility to give City of Renton Traffic Engineering
Division 24 hour notification of work to be performed on project for Inspection
purposes (phone 235 - 2620). City of Renton standard specification 8- 20.3(2), 'No work
shall be covered until it has been examined by the Engineer."
8. The contractor shall submit a request for materials approval at the earliest possible
date.
y. As -Built drawings will be required on completion of all projects.
•� E'L
Fv- taro LL•/xE �.
[u-
Lve
AIAWW.4
FusE ,err
1NP1A4% ,s-e —
SPL /C.E ,eiT
PT' L H vy,
tie
i
� < z
n
�Je y
9
i�
LIGHTING STANDARD B JUNCTION BOX
(' 7-
JUNCTION
STREET LIGHT POLE BOX
PLAN VIEW
DEEP.
SIDE ..y: • � :D�:jra
SIDE VIEW
�. p.-` 'r o.•..e ;, NOTE: CLASS 'B' CONCRETE
` —�
TO BE USE IN
•:
�i CONSTRUCTION OF PAD
INDIVIDUAL JUNCTION BOX
PLAN VIEW
,PEV.PG_Z_g, AETq }L 811EE7¢
As BU /L T
/ hereby declare Mal street 19hliny
faeil /l }es shows hereas are as locoled
from fie%' gar ✓ey Gurd�or /nspec }Ian.
!/ern L. Bow , /r, /v
nr
i
/
k_11915;L
0 Add Service Cobrriet; City review eamaWq B1-B9 I/rs B
UN / ®N PLACE
I N T E N S U S Un /Can Ae NE e NE JrN alert
ENGINEERING • SURVEYING (. /� o% ,fenfon, 914,sh.
17508 PALOMINO DRIVE • BOTHELL. WA 98012
(206) 487 -7282
cS;rgEET ZMHT/NG PC A N
5.4 .?.r "t 6' Or 6 0Y.2305.01
GENERAL NOTES
i. Approximate locatlons of existing utilities have been obtained from available records
and are shown for convenience. The contractor shall be responsible for verifying the
location of all existing utilities whether shown or not. The contractor shall call
the Utility Locator Service, 1- 800 - 424 -5555, five working days prior to any
construction.
2. It is the responsibility of the contractor to verify what permits have been secured
if any) and to obtain and possess all required permits prior to commencing
construction.
3. The contractor shall take all necessary precautions for the safety of employees on
the project and shall comply with all applicable provisions of Federal, State, and
Municipal safety laws and building codes. He shall erect and properly maintain, at
all times, as required by the conditions and progress of the work, all necessary
safeguards for protection of workmen and the public; shall post danger signs warning
against known or unusual hazards; and he shall designate a responsible member of his
organization on the construction site whose duty shall be the prevention of
accidents.
4. All work shall be In accordance with the project specifications and these plans.
5. The locations of features and existing utilities are approximate and shall be
verified in the field by the contractor.
6. The contractor shall notify all utilities regarding their facilities located within
the project limits 48 hours prior to commencing work and shall coordinate his work
with those utilities. The contractor shall be responsible for any damage to
existing utilities and shall notify the affected utility and the City immediately
upon damage.
7. It is the contractor's responsibility to give City of Renton Traffic Engineering
Division 24 hour notification of work to be performed on project for Inspection
purposes (phone 235 - 2620). City of Renton standard specification 8- 20.3(2), 'No work
shall be covered until it has been examined by the Engineer."
8. The contractor shall submit a request for materials approval at the earliest possible
date.
y. As -Built drawings will be required on completion of all projects.
•� E'L
Fv- taro LL•/xE �.
[u-
Lve
AIAWW.4
FusE ,err
1NP1A4% ,s-e —
SPL /C.E ,eiT
PT' L H vy,
tie
i
� < z
n
�Je y
9
i�
LIGHTING STANDARD B JUNCTION BOX
(' 7-
JUNCTION
STREET LIGHT POLE BOX
PLAN VIEW
DEEP.
SIDE ..y: • � :D�:jra
SIDE VIEW
�. p.-` 'r o.•..e ;, NOTE: CLASS 'B' CONCRETE
` —�
TO BE USE IN
•:
�i CONSTRUCTION OF PAD
INDIVIDUAL JUNCTION BOX
PLAN VIEW
,PEV.PG_Z_g, AETq }L 811EE7¢
As BU /L T
/ hereby declare Mal street 19hliny
faeil /l }es shows hereas are as locoled
from fie%' gar ✓ey Gurd�or /nspec }Ian.
!/ern L. Bow , /r, /v
nr
i
/
k_11915;L
0 Add Service Cobrriet; City review eamaWq B1-B9 I/rs B
UN / ®N PLACE
I N T E N S U S Un /Can Ae NE e NE JrN alert
ENGINEERING • SURVEYING (. /� o% ,fenfon, 914,sh.
17508 PALOMINO DRIVE • BOTHELL. WA 98012
(206) 487 -7282
cS;rgEET ZMHT/NG PC A N
5.4 .?.r "t 6' Or 6 0Y.2305.01