HomeMy WebLinkAboutT-199711Y — CONNECT TO EXISTING ILLUMINATION CIRCUIT
L
INAL CAB.
R 661 R
Y 662 Y
G 663 G
W 665 11 POLE NO.
WB 666 WB
R 611 R
Y 612 Y
G 613 G
W 615 W
WB 616 WB
PED HERD 9
HERD 2
R 621 R
R 741 HAND
R 622 Y
G 1 742 MAN
W 745 C
HERD 5
T�
PPB 9
R 661 R
Y 746
Y 662 R
VOOPT. DET. 1
WB
02
OPT. DET. 2 HEAD 1
R
YY
BLU G
N925 0 113WB
P O L E N 0. 2
WB 666 S
915
HERD 6
W
MAN 742 G
R 661 R
Y 662 A
C 745 W PED HEAD 11
R 721 HAND'
PPB 10 G 722 1 MAN
746 Y W I 7251-C
747 WB
G 663 G
PED HERD 8
HAND 721 R /—POLE NO. 1
MAN 722 G
C 725 W
TERMINAL CAB.
W 665 C
WB 666 S
PPB 8 R P6E R
726 Y Y 622 Y
WB 727
HERD 7
R
W 625 W :
m6SY G
W
WB 626 WB
WB
'104
OPT. DET. 3 HEAD 4
931 C- Isf R
932 Y Y
935 BLU G
aq� W
W
T
HERD 3
R 641 R
A 642 Y
G 643 G
C 645 W
S 646 W
L
TERMINAL CAB.
R 641 R
Y 642 Y
G 643 G -
W 645 W
WB 646 WB
L—
POLE N0. 4
lllliF7&mm
5C J I�
3CSH
5C
5C
3CSH
5C
2CSH J
2CSH
Ef 841/842
843/844
CONTROLLER CABINET
BLU 935 PHASE 4
J Y 932 OPT. DET. 3 z
0 931 0
BLU 925 PHASE 2 ~
Y 922 OPT. DET. 2 w
861/862 0 921 i
PL U 915 PHASES 1 a 6
Y 912 OPT. DET. 1 D
0 911
W 862 PHASE 6
B 861
W 844 PHASE 4
8 843 INSIDE LANE o
W 842 PHASE 4 F
B 841 CURB LANE
w
W 822
B 821 PHASE 2 w
W 812 PHASE 1
B 811
WB 747
Y 746 PHRSE 4
W 745 HEADS 9,10 i
G 742
R 741 m
WB 727 j
Y 726 PHASE 2 w
W 725 HEADS 8, 11 w
G - 722- IL
R 721
WB S
W 665 PHASE 6
G 663 HEADS 5, 6
Y 662
R 661
WB S
W 645 PHASE 4 w
G 643 HEADS 3,4 M
m a: 7: x Y 642 _
(n U) 00 cn to to 07 w
UUUUC�Uo R 641 >
mmmcuacucu WB S
W 625 PHASE 2
G 623 HEADS 1,2
Y 622
R 621
WB S
W 615 PHASE 1
G- 613 HEAD 7
U w Y 612
R 611
U U U U
U7 0 U7 Ln Lo U): -
J U
w
_z
z
0
U
w
W
h
2
W 502
LE 8 501 POWER
NOTES: S DENOTES SPARE CONDUCTOR.
NO TERMINAL REQUIRED.
TO POWER VAULT. RMPLIFIER FOR TERMINALS 841/842
_.. cu... ...0 DE.-Hy. FEATURE.
5� 116
HERD 2
R 621 R
R 622 Y
821/822
G 623 G
C 625 W
S 626 WB
r-
02
OPT. DET. 2 HEAD 1
R
YY
BLU G
N925 0 113WB
P O L E N 0. 2
PED HERD 10
HAND 741 R
W
MAN 742 G
C 745 W PED HEAD 11
R 721 HAND'
PPB 10 G 722 1 MAN
746 Y W I 7251-C
747 WB
PED HERD 8
HAND 721 R /—POLE NO. 1
MAN 722 G
C 725 W
TERMINAL CAB.
PPB 11
Y 726
PPB 8 R P6E R
726 Y Y 622 Y
WB 727
727 WB G 623 G
W 625 W :
WB 626 WB
JUNCTION BOX
Ef 841/842
843/844
CONTROLLER CABINET
BLU 935 PHASE 4
J Y 932 OPT. DET. 3 z
0 931 0
BLU 925 PHASE 2 ~
Y 922 OPT. DET. 2 w
861/862 0 921 i
PL U 915 PHASES 1 a 6
Y 912 OPT. DET. 1 D
0 911
W 862 PHASE 6
B 861
W 844 PHASE 4
8 843 INSIDE LANE o
W 842 PHASE 4 F
B 841 CURB LANE
w
W 822
B 821 PHASE 2 w
W 812 PHASE 1
B 811
WB 747
Y 746 PHRSE 4
W 745 HEADS 9,10 i
G 742
R 741 m
WB 727 j
Y 726 PHASE 2 w
W 725 HEADS 8, 11 w
G - 722- IL
R 721
WB S
W 665 PHASE 6
G 663 HEADS 5, 6
Y 662
R 661
WB S
W 645 PHASE 4 w
G 643 HEADS 3,4 M
m a: 7: x Y 642 _
(n U) 00 cn to to 07 w
UUUUC�Uo R 641 >
mmmcuacucu WB S
W 625 PHASE 2
G 623 HEADS 1,2
Y 622
R 621
WB S
W 615 PHASE 1
G- 613 HEAD 7
U w Y 612
R 611
U U U U
U7 0 U7 Ln Lo U): -
J U
w
_z
z
0
U
w
W
h
2
W 502
LE 8 501 POWER
NOTES: S DENOTES SPARE CONDUCTOR.
NO TERMINAL REQUIRED.
TO POWER VAULT. RMPLIFIER FOR TERMINALS 841/842
_.. cu... ...0 DE.-Hy. FEATURE.
5� 116