HomeMy WebLinkAboutT-204501STA 26 +49.86 - WEST 114 CORNER SEC 15, TW 23M ROE W A POR110N OF THE SW /4 OF THE NW /4 OF THE NW /4, SEC 15, TWP 23N, RGE 5E, W.M.
II NBBI$2 -W 618.56'
1 I 75.00' 62.00' 60.00' 6MW 60,.O(r �-
I II I 1
i l ll I I'
II 30
II D
b
11 W i yf- - -- o N 3 4 5
STREET — — NAME — SIGN � 4N•r
1 144• PVM WITH I ( 1 I z� N
I Y 'I
INSTALL STOP ISIG I PER CITY SPECS
LL, I I I 1 W PA INSTALL S SIGN CON UCT 5 HIDE CONCRETE SIDEWALK THIS DE
Z e D_ I3• q PER CITY g S, BA OF S/W IS 1' INSIDE EASEMENT
Yya 93' INSTALL THERM TIC STOP BAR PER qR s!a 1188
j 25.00'1 CITY STANDARD LOCATION STA 1178- STREET GHT FIXTURE 1-1' Le -*R 3t
—j 3X7 CONC PAD W/ .UNCTION BOX (TYPICAL) STA LIGHT FIGURE 1 -2-
Q IDA 1780 Pde to, t7€sZ
\ R 5
Z — 1 --- Comm UNDIN SIDEWALK
— — — — — — — — — — — — — — — —
OI I I I I 48.64' 6200' Ti UTILITY D
DIRECTION PT O+ .31 1WLT
I I I OF
_- EX15.,2 SO
I I I I—" -f- 40• NEW R/W 32' CURB TO CURB — N8895' —
.Ww
I 1 I T I 1+00 79.5' TO CA
2 +00 3100
WY PT G +35.44
1 I � 16• RT
VERIFY PROP CORNER 3' BACK CURB TO PA N8895591W 618.8Y
I + I I 1 NE SECOND srREEr
R =13.00'
JI i EXISTING FENCE ALONG ROW
II H/C RAMP TYP.
Ii STA G +00 O CA UNION AVE STREET LIGHTING PLAN
I I I I I = 13+05.12
STA 13+25.03 = 1 /16 CDR
0+00 = W 1/4 CORNER
SEC 15,TWP 23N RGE 5E
LEGEND
FODOWAMDED
a 3
FOR APPROVAL
ELECTRICAL CONDUIT W/ 2 -1c #8, 1- 1C J'10
BARE
o
JUNCTION BOX
S R= 120.00'
--)C(
STANDARD 25' DAVIT LUMINAIRE POLE
� —
�
Ni9
W/ 8' ARM LENGTH FOR HIGH PRESSURE
RRooI+�
pY�Rrr -L
LIGHTING CON ACTOR 8 CONTROL CABINET ,V3066644
SODIUM VAPOR G.E. FIXTURE PER CITY STNDS
+
STREET NAME SIGN (SNS)
LUMINAIRE TABLE
w
LUMINAIRE
WATTAGE VOLTAGE CIRCUIT IES
P °L`
NUMBER
PATTERN
Mo.
IISO
L -1 100 W 240 VAC 1 M -C -111
L -2
100 W 240 VAC 1 M -O -III
t-I 82-
L -3
100 W 240 VAC 1 M -C -111
11 84
IRO 41 -2045
STREET UGHT:VG CONSTRUCTION NOTES
1. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL
TO THE CITY OF RENTON PRIOR TO INSTALLATION.
2- AS BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF ALL
PROJECTS
3. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THE
FACILITIES LOCATED WITHIN THE PROJECT LIMITS 48 HOURS PRIOR
TO GRADING AROUND OR UNDERGROUND CROSSING OF UTILITIES.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO.
EXISTING UTILITIES THE CONTRACTOR SHALL NOTIFY THE
AFFECTED UTILITY AND THE CITY IMMEDIATELY UPON DAMAGE.
5. THE CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL POLE I.D.
NUMBER AS DIRECTED BY THE TRAFFIC ENGINEER.
6. THE CONTRACTOR SHALL VERIFY THE LOCATION OF THE PUGET POWER
SERVICE POINT.
7. THE LIGHT STANDARDS. JUNCTION BOXES, AND OTHER FIXTURES
SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS HEREIN.
8. A PHOTOCELL SHALL BE INSTALLED ONLY ON LIGHT FIXTURE NO. 1.
9. NO HANDHOLES, POLES. OR JUNCTION BOXES SHALL BE LOCATED
WITHIN THE SIDEWALK.
10. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE STANDARDS
AND SPECIFICATIONS OF THE CITY OF RENTON AND THE 1991
STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL
CONSTRUCTION BY WSDOT AND APWA, WASHINGTON STATE CHAPTER.
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN COPIES
OF THESE DOCUMENTS. IN THE CASE OF CONFLICTS, THE
USED.
il, i 11$ Tn^ ` I_ STR F _T L1G HT T. D. NDMBE: 5 PER
STA N,DARD DRAW]NG JIR 09A,
60.00'
70.00'
88.00'
AS BUILT CERTIFICATE:
Information marked -AB- or -as built- was measured after
construction by me. It is shown correctly on these drawings.
G
Leonard E Emersom PLS d J �•�Q E
certificate number 17665 f WAS &�
G�i�Oa '1oa Z? : t1
;;;._ate 11 a7 43
The
Rykele Engineering Group Inc.
Correlilting Engineer -CM1. Municipal. Suhdivfalons
P.O. Box 133 Kent, WA 98035 -0133 (206) 631 -6598
RECD tnENP^i
FODOWAMDED
a 3
FOR APPROVAL
_ »<
D= 25'44'12"
6
Q M
7
S R= 120.00'
o
Z °z
� —
�
Ni9
HB N !• S
RRooI+�
pY�Rrr -L
LIGHTING CON ACTOR 8 CONTROL CABINET ,V3066644
4 +7 -3'
A= 24.57'
D= 11'43'47'
w
TYPE 1 -A
R= 120.00' -
JUNCTION BOX PEI CITY DETAILS
.00'
1 -1/2' GALV STEEI
A= 53.03' /
D= 37'S8'40�
CONDUIT TO PUGET POWER
VAULT TO BE CON. CTED BY
R =80.9_0�-
TY/
_ OTHERS 3@6 AWG S.E.
�b AyrE,p Sowrc�.
6 0'
'
—
4+00
IX 48*0EMOON SYSTEM
a
R =10'
5 +00
AS BUILT CERTIFICATE:
Information marked -AB- or -as built- was measured after
construction by me. It is shown correctly on these drawings.
G
Leonard E Emersom PLS d J �•�Q E
certificate number 17665 f WAS &�
G�i�Oa '1oa Z? : t1
;;;._ate 11 a7 43
The
Rykele Engineering Group Inc.
Correlilting Engineer -CM1. Municipal. Suhdivfalons
P.O. Box 133 Kent, WA 98035 -0133 (206) 631 -6598
RECD tnENP^i
FODOWAMDED
FOR APPROVAL
_ »<
BY r %F
`�JNE 101 19`i Z-
577777 '9k-
Cu
p}�,,��
5
REVISION
0 3
Y] O
m �
Q
o`
I
ITY ESMT4 fl/w
2.S5 ES MIT
I
I
I
IND 5' CONC. S/W
10' STORM DRAIN
5 +23.46 = I
FACE OF CURB
SCALE 1- = 20 FEET
OWNER /DEVELOPER
LYLE BARGER
EXPIRES 6 /9/93 198 UNION AVE NE
RENTON, WA
CITY OF RENTON
DEPARTMENT OF PUBLIC WORKS
BRIAR PATCH SUBDIVISION, RENTON, WA
STREET LIGHTING PLAN
DESIGNED AJR DATE FILE NO
DRAWN AJR SCALE '1=20 FIELD BOOK_ PG
CHECKED AJR SHEET /Z-
APPROVED OF /'/ DIRECTOR OF PUBLIC WORKS
1 114 1 1 1 I 1 Al I I I I I I I T I 1 I I ® I 1 I I Z 1 I I IT I I i I I