Loading...
HomeMy WebLinkAboutT-204501STA 26 +49.86 - WEST 114 CORNER SEC 15, TW 23M ROE W A POR110N OF THE SW /4 OF THE NW /4 OF THE NW /4, SEC 15, TWP 23N, RGE 5E, W.M. II NBBI$2 -W 618.56' 1 I 75.00' 62.00' 60.00' 6MW 60,.O(r �- I II I 1 i l ll I I' II 30 II D b 11 W i yf- - -- o N 3 4 5 STREET — — NAME — SIGN � 4N•r 1 144• PVM WITH I ( 1 I z� N I Y 'I INSTALL STOP ISIG I PER CITY SPECS LL, I I I 1 W PA INSTALL S SIGN CON UCT 5 HIDE CONCRETE SIDEWALK THIS DE Z e D_ I3• q PER CITY g S, BA OF S/W IS 1' INSIDE EASEMENT Yya 93' INSTALL THERM TIC STOP BAR PER qR s!a 1188 j 25.00'1 CITY STANDARD LOCATION STA 1178- STREET GHT FIXTURE 1-1' Le -*R 3t —j 3X7 CONC PAD W/ .UNCTION BOX (TYPICAL) STA LIGHT FIGURE 1 -2- Q IDA 1780 Pde to, t7€sZ \ R 5 Z — 1 --- Comm UNDIN SIDEWALK — — — — — — — — — — — — — — — — OI I I I I 48.64' 6200' Ti UTILITY D DIRECTION PT O+ .31 1WLT I I I OF _- EX15.,2 SO I I I I—" -f- 40• NEW R/W 32' CURB TO CURB — N8895' — .Ww I 1 I T I 1+00 79.5' TO CA 2 +00 3100 WY PT G +35.44 1 I � 16• RT VERIFY PROP CORNER 3' BACK CURB TO PA N8895591W 618.8Y I + I I 1 NE SECOND srREEr R =13.00' JI i EXISTING FENCE ALONG ROW II H/C RAMP TYP. Ii STA G +00 O CA UNION AVE STREET LIGHTING PLAN I I I I I = 13+05.12 STA 13+25.03 = 1 /16 CDR 0+00 = W 1/4 CORNER SEC 15,TWP 23N RGE 5E LEGEND FODOWAMDED a 3 FOR APPROVAL ELECTRICAL CONDUIT W/ 2 -1c #8, 1- 1C J'10 BARE o JUNCTION BOX S R= 120.00' --)C( STANDARD 25' DAVIT LUMINAIRE POLE � — � Ni9 W/ 8' ARM LENGTH FOR HIGH PRESSURE RRooI+� pY�Rrr -L LIGHTING CON ACTOR 8 CONTROL CABINET ,V3066644 SODIUM VAPOR G.E. FIXTURE PER CITY STNDS + STREET NAME SIGN (SNS) LUMINAIRE TABLE w LUMINAIRE WATTAGE VOLTAGE CIRCUIT IES P °L` NUMBER PATTERN Mo. IISO L -1 100 W 240 VAC 1 M -C -111 L -2 100 W 240 VAC 1 M -O -III t-I 82- L -3 100 W 240 VAC 1 M -C -111 11 84 IRO 41 -2045 STREET UGHT:VG CONSTRUCTION NOTES 1. THE CONTRACTOR SHALL SUBMIT A REQUEST FOR MATERIALS APPROVAL TO THE CITY OF RENTON PRIOR TO INSTALLATION. 2- AS BUILT DRAWINGS WILL BE REQUIRED ON COMPLETION OF ALL PROJECTS 3. THE CONTRACTOR SHALL NOTIFY ALL UTILITIES REGARDING THE FACILITIES LOCATED WITHIN THE PROJECT LIMITS 48 HOURS PRIOR TO GRADING AROUND OR UNDERGROUND CROSSING OF UTILITIES. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO. EXISTING UTILITIES THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY AND THE CITY IMMEDIATELY UPON DAMAGE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL POLE I.D. NUMBER AS DIRECTED BY THE TRAFFIC ENGINEER. 6. THE CONTRACTOR SHALL VERIFY THE LOCATION OF THE PUGET POWER SERVICE POINT. 7. THE LIGHT STANDARDS. JUNCTION BOXES, AND OTHER FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE DETAILS HEREIN. 8. A PHOTOCELL SHALL BE INSTALLED ONLY ON LIGHT FIXTURE NO. 1. 9. NO HANDHOLES, POLES. OR JUNCTION BOXES SHALL BE LOCATED WITHIN THE SIDEWALK. 10. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON AND THE 1991 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION BY WSDOT AND APWA, WASHINGTON STATE CHAPTER. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS. IN THE CASE OF CONFLICTS, THE USED. il, i 11$ Tn^ ` I_ STR F _T L1G HT T. D. NDMBE: 5 PER STA N,DARD DRAW]NG JIR 09A, 60.00' 70.00' 88.00' AS BUILT CERTIFICATE: Information marked -AB- or -as built- was measured after construction by me. It is shown correctly on these drawings. G Leonard E Emersom PLS d J �•�Q E certificate number 17665 f WAS &� G�i�Oa '1oa Z? : t1 ;;;._ate 11 a7 43 The Rykele Engineering Group Inc. Correlilting Engineer -CM1. Municipal. Suhdivfalons P.O. Box 133 Kent, WA 98035 -0133 (206) 631 -6598 RECD tnENP^i FODOWAMDED a 3 FOR APPROVAL _ »< D= 25'44'12" 6 Q M 7 S R= 120.00' o Z °z � — � Ni9 HB N !• S RRooI+� pY�Rrr -L LIGHTING CON ACTOR 8 CONTROL CABINET ,V3066644 4 +7 -3' A= 24.57' D= 11'43'47' w TYPE 1 -A R= 120.00' - JUNCTION BOX PEI CITY DETAILS .00' 1 -1/2' GALV STEEI A= 53.03' / D= 37'S8'40� CONDUIT TO PUGET POWER VAULT TO BE CON. CTED BY R =80.9_0�- TY/ _ OTHERS 3@6 AWG S.E. �b AyrE,p Sowrc�. 6 0' ' — 4+00 IX 48*0EMOON SYSTEM a R =10' 5 +00 AS BUILT CERTIFICATE: Information marked -AB- or -as built- was measured after construction by me. It is shown correctly on these drawings. G Leonard E Emersom PLS d J �•�Q E certificate number 17665 f WAS &� G�i�Oa '1oa Z? : t1 ;;;._ate 11 a7 43 The Rykele Engineering Group Inc. Correlilting Engineer -CM1. Municipal. Suhdivfalons P.O. Box 133 Kent, WA 98035 -0133 (206) 631 -6598 RECD tnENP^i FODOWAMDED FOR APPROVAL _ »< BY r %F `�JNE 101 19`i Z- 577777­ ­'9k- Cu p}�,,�� 5 REVISION 0 3 Y] O m � Q o` I ITY ESMT4 fl/w 2.S5 ES MIT I I I IND 5' CONC. S/W 10' STORM DRAIN 5 +23.46 = I FACE OF CURB SCALE 1- = 20 FEET OWNER /DEVELOPER LYLE BARGER EXPIRES 6 /9/93 198 UNION AVE NE RENTON, WA CITY OF RENTON DEPARTMENT OF PUBLIC WORKS BRIAR PATCH SUBDIVISION, RENTON, WA STREET LIGHTING PLAN DESIGNED AJR DATE FILE NO DRAWN AJR SCALE '1=20 FIELD BOOK_ PG CHECKED AJR SHEET /Z- APPROVED OF /'/ DIRECTOR OF PUBLIC WORKS 1 114 1 1 1 I 1 Al I I I I I I I T I 1 I I ® I 1 I I Z 1 I I IT I I i I I