Loading...
HomeMy WebLinkAboutT-224605Ij f :I y MATCHLINE STA. 14 +50 SEE SHEET C -33 NEW evopworoogS 5 5 14 yRGIiT C-2C 5rE )GLVAwiNA770A1 4 hl ji1 P A#jS FaK THE FOXAGSr 6 4 _ �— _ °� �@ NE 6TH/ ST 42' 42 cAs$Tw APAarA&wm?5 _I` t 4 - — - -- i ,s r_ C D^ — — — a DI}o I1M1Y 19 , 1997. 3 -'- - — - -- b r s — I 15 W1 E,URITY Jam — UT1r NE INGRESS/EGRESS ESM'T. ESM'T. REC. 5 I I CORRECTED REC. N0910 ORG. REC. NO. 5922 NO. 3070189 W " 5947064 6TH ST. m 30' 0 20 40 so r. .Zrn7 l I 42' Z, s 4„ 5 �I STREET LIGHTING NOTES D i , ? I' 9 < ( 12 LEGEND 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL rn i 1 STANDARD SPECIFICATIONS AND THESE PLANS AND THE LATEST COORDINATION WITH THE POWER COMPANY FOR SERVICE WORK I EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND ALSO PROVIDE'AND INSTALL ALL MATERIAL' NOT PROVIDED Z ! f I TYPE M -C -3' H.P.S. LUMINAIRE, ARM AND, MUNICIPAL CONSTRUCTION BY WSDOT AND APWA L, O Pl I I AND ALUMINUM DAVIT STYLE POLE BY THE POWER' COMPANY. WASHINGTON STATE CHAPTER. IT IS THE RESPONSIBILITY OF ( o THE CONTRACTOR TO OBTAIN COPIES OF THESE DOCUMENTS. IN 4 13. NO HANDHOLDS, POLES, OR JUNCTION BOXES SHALL BE LOCATED o 5 I CONCRETE PAD LIGHT BASE AND THE CASE OF CONFLICTS, THE STANDARDS AND SPECIFICATIONS WITHIN THE SIDEWALK. �' Ili TYPE 1 "JUNCTION BOX OF THE CITY, OF RENTON SHALL BE USED. 14 ALL STREET LIGHTING CONDUIT V I 2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND ULT SHALL HAVE A MINIMUM OF 24� I I I' — — — — PVC CONDUIT (SEE WIRING SCHEDULE) SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR AS INCHES OF COVER. 1t I I I 11 NECESSARY. FOR UTILITY LOCATE CALL 1-800-424--5555. 15. PROVIDE AS BUILT DRAWINGS AT COMPLETION OF PROJECT. I STREET LIGHT CONTACTOR CABINET BEE EXISTING LUMINAIRE TO BE 3. ALL MATERIALS SHALL BE NEW AND OF THE BEST AVAILABLE REPLACED WITH 100' W HPS # I AND FOUNDATION GRADE OR QUALITY, EXCEPT AS NOTED. ALLL EQUIPMENT M -C -III LUMINAIRE BY CITY: TYKE 1 JUNCTION BOX WITH FURNISHED SHALL BE GUARANTEED AGAINST COMPONENT , B FAILURE FOR A PERIOD OF ONE YEAR FOLLOWING ACCEPTANCE CONCRETE PAD BY THE CITY q 4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF I E I 4 I I WIRE NOTE RENTON TRAFFIC ENGINEER FOR MATERIAL APPROVAL AT THE p A' T - p EARLIEST POSSIBLE DATE. WIRING SCHEDULE THIS SHEET ONLY CONSTRUCTION NOTE 5. ALL WORK SHALL BE CONSISTENT WITH AFFECTED UTILITY AGENCY'S REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES FORTY-EIGHT (48) HOURS BEFORE COMMENCING WORK, AND SHALL COORDINATE THE WORK WITH UTILITIES THROUGHOUT THE PROJECT. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL 'NOTIFY ', THE AFFECTED UTILITY COMPANY AND THE CITY IMMEDIATELY UPON DAMAGE. 7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON CONSTRUCTION ENGINEERING DIVISION AT 277 -5570 FOR INSPECTION PURPOSES TWENTY-FOUR (24) HOURS 'BEFORE COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN EXAMINED' BY THE ENGINEER. RUN POLE ID NO. POLE LOCATION NO. CONDUIT CONDUCTORS MAST ARM 1.5" PVC (SCHEDULE 40) 2 - #10 / ? \ 1.5" PVC ,(SCHEDULE 40) 2 - #10, 1-#8 BARE 2L 1.5' PVC (SCHEDULE', 80) 2 - #10 A1.5" PVC (SCHEDULE 40) 2 - #6 2 4" V . SCH 9 +17 21.5' LT I m Pvc 25' C I 8. CAUTION - OVERHEAD ELECTRICAL SERVICE LINES ARE NOT SHOWN ON THE DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING THE EXTENT OF ANY HAZARD CREATED BY OVERHEAD ELECTRICAL POWER IN ALL AREAS AND SHALL FOLLOW PROCEDURES DURING CONSTRUCTION' AS REQUIRED BY LAW AND REGULATIONS AND TAKE PRECAUTIONS THAT MAY BE REQUIRED. MINIMUM CLEARANCE FROM OVERHEAD POWER TO THE STREET LIGHT STANDARDS IS 10 TO 16 FEET, DEPENDING ON VOL TAGS. 9. MAINTAIN CLEARANCES FROM SUCH FEATURES SUCH AS PROPERTY LINES, LOCATION OF DRIVEWAYS, FIRE HYDRANTS AND ANY OTHER FEATURES. MINIMUM CLEARANCE FROM DRIVEWAYS SHALL BE 10 -FEET, MINIMUM CLEARANCE FROM CURB 30- INCHES. POLE NO. POLE ID NO. POLE LOCATION POLE OFFSET LAMP WATTAGE MOUNTING HEIGHT* MAST ARM CIRCUIT NO. REMARKS 1 7 +67 21.5' LT 100 25' 6' EX. A -1 6TH ST 2 BELLEVUE,. WASHINGTON 98004: 9 +17 21.5' LT 100 25' 6' EX. A -1 6TH ST 3 1 SPLICE CONDUCTORS TO EXISTING LIGHTING CIRCUIT IN EXISTING, TYPE 1 JUNCTION BOX. 10 +64 21.5' LT 100 25' 6' EX. A -1 6TH ST 4 8 +90 21.5' LT 100 30' 6' EX. BREMERTON 5 C3> 12+20- 21.5' LT 100 30' 6' - MERTON 31 euwu T Mh 11 41. LT 0 O' 1 — ,. _:. ;_: I.. '='' _ -_- C"D D.H.E. 7 +70 41.5' L 400 40 12' DUVALL 3a APPROVED 91-50 1 'W -s, Lr;' 4= 0' 12' C -2 DRVALL .# I TRANSPORTATION PLANNING ' DEPARTRIENT OF PuBGIa WORKS (XLP) INSULATION. CONDUCTOR INSULATION FOR PHOTO CELL & ENGINEERING, INC. # - 7'^ 2101 -112TH AVENUE NORTHEAST, SUITE 110 CIRCUIT TO BE THHN, BELLEVUE,. WASHINGTON 98004: 4 5 EXISTING LUMINAIRE TO BE .: -7180 REPLACED WITH 100 W HPS THE ORCHARDS DI V 2 I ADDtTD CdAISrRcICTioA! 1 SPLICE CONDUCTORS TO EXISTING LIGHTING CIRCUIT IN EXISTING, TYPE 1 JUNCTION BOX. M -C -III LUMINAIRE BY CITY _ pC °uiFlu�rroivs *All.Al. NO. - FtEvo ON .Y' CONTINUITY ANY DEFECTS NOTED SHALL BE CORRECTED BEFORE FINAL' 1 j . I: CITY OF RENTON 10. ALL CONDUCTORS FOR STREET LIGHTING TO BE TYPE USE -RHH *STAND RD DA POLE; S STR L HTING D ILS £X, A -� DEPARTRIENT OF PuBGIa WORKS (XLP) INSULATION. CONDUCTOR INSULATION FOR PHOTO CELL f j - 7'^ CIRCUIT TO BE THHN, 4 .: THE ORCHARDS DI V 2 11. AND MEGGER TEST S SHALL BE CONDUCTED AND 1 SPLICE CONDUCTORS TO EXISTING LIGHTING CIRCUIT IN EXISTING, TYPE 1 JUNCTION BOX. - OMAN ILL UA" MAN CONTINUITY ANY DEFECTS NOTED SHALL BE CORRECTED BEFORE FINAL' 1 j . I: R.M.H. 5r1 -96 C3> ACCEPTANCE OF THE ELECTRICAL SYSTEM FOR STREET LIGHTS . CONDUIT AND SWEEP CONDUIT INTO NEW 1 JUNCTION X: 2 LOCATE EXISTING 4 B0 O ;' —_ i J — - #, - euwu T Mh DATE No.' �9� ®,. ryae-t _ — -- -- s i — ,. _:. ;_: I.. '='' _ -_- C"D D.H.E. -fCALE 1 " =40' reo soa�_PA4 _. APPROVED f1E8T C31 OF Cfh; T 2 a4&.f- SCANNED MAR 3 0:20 H x c a B o °z �4 661 H x c a B o °z