HomeMy WebLinkAboutT-225705CONSTRUCTION NOTES
O REMOVE CONDUCTORS FROM PEDESTRIAN POLE TO JUNCTION BOX. REMOVE PEDESTRIAN
SIGNAL HEADS AND PEDESTRIAN PUSH — BUTTONS FOR RE —USE. REMOVE POLE FOR SALVAGE.
REMOVE FOUNDATION.
O REMOVE ALL SIGNAL CONDUCTORS FROM MAST —ARM SIGNAL POLE TO POLL- MOUNTED TERMINAL
CABINET ON SIGNAL POLE AT SE CORNER. REMOVE OPTICOM LEAD —IN FROM MAST —ARM
SIGNAL POLE TO CONTROLLER CABINET. REMOVE SIGNAL HEADS AND OPTICAL DETECTOR FOR
RE —USE. REMOVE ARROW LENSES FROM SIGNAL HEADS 4 & 5 AND REPLACE WITH CIRCULAR
LENSES. REMOVE OVERHEAD SIGN FOR SALVAGE. REMOVE POLE AND MAST —ARM FOR RE —USE.
REMOVE FOUNDATION AND ANCHOR BOLTS TO A MINIMUM OF 12 INCHES BELOW FINISH GRADE.
O INSTALL SIGNAL HEAD NO. 11 ON SIGNAL POLE SHAFT WITH TYPE "K" MOUNTING. INSTALL
SIGNAL HEAD NO. 3 ON EXISTING TENON AT END OF MAST —ARM WITH TYPE "L" MOUNTING.
INSTALL 5— CONDUCTOR CABLE FROM SIGNAL HEAD NO. 3 TO POLE— MOUNTED TERMINAL
CABINET AND CONNECT TO EXISTING TERMINALS OCCUPIED BY 5— CONDUCTOR CABLE LABELLED
651 THRU 656. INSTALL OPTICAL DETECTOR (3M MODEL 51 1) ON POLE SHAFT AND INSTALL
OPTICOM LEAD —IN FROM DETECTOR TO CONTROLLER CABINET. INSTALL SIGNAL HEAD NO. 11
ON POLE SHAFT WITH TYPE "K" MOUNTING. INSTALL 5— CONDUCTOR CABLE FROM SIGNAL
HEAD NO. 11 TO CONTROLLER CABINET.
O4 CONSTRUCT SIGNAL POLE FOUNDATION (SEE POLE DETAIL SHEET FOR LOCATION AND SIZE).
INSTALL NEW S!GNAL POLE WITH 40 FT. MAST —ARM (POLE NO. 1 ON POLE DETAIL SHEET).
INSTALL NEW VEHi ^.LE AND PEDESTRIAN SIGNAL DISPLAYS AND 2 PEDESTRIAN PUSH -
BUTTONS. INSTALL STREET —NAME SIGN.
O5 INSTALL PEDESTRIAN SIGNAL HEAD NO. 16 ON EXISTING MAST —ARM SIGNAL POLE WITH
HARDWARE TO MATCH EXISTING PEDESTRIAN SIGNAL HEAD MOUNTING HARDWARE. INSTALL
PEDESTRIAN PUSH — BUTTON FOR NEW EAST —WEST PEDESTRIAN CROSSING.
O CONSTRUCT 3 FT. DIA. BY 7 FT. DEEP SIGNAL POLE FOUNDATION AT STA 22 +59, 41 FT.
RT. RE— INSTALL MAST —ARM SIGNAL POLE REMOVED BY CONSTRUCTION NOTE NO. 2 (NOTE:
MAST —ARM SHALL BE REMOVED AND ROTATED 180 DEGREES FOR PROPER TENON ORIENTATION).
RE— INSTALL VEHICLE SIGNAL HEADS, OPTICAL DETECTOR AND STREET —NAME SIGN. INSTALL
PEDESTRIAN SIGNAL HEAD NO. 17 AND PEDESTRIAN PUSH — BUTTON FOR NEW EAST —WEST
PEDESTRIAN CROSSING. ROUTE NEW CONDUCTORS FOR VEHICLE SIGNAL DISPLAY TO POLE—
MOUNTED TERMINAL CABINET ON EXISTING SIGNAL POLE AT SE CORNER. ROUTE NEW
CONDUCTORS FOR PEDESTRIAN SIGNAL HEAD AND PEDESTRIAN PUSH — BUTTON TO PEDESTRIAN
SIGNAL HEAD TERMINAL COMPARTMENT ON POLE AT SE CORNER.
O7
REMOVE AND REPLACE EXISTING DAMAGED TYPE 2 JUNCTION BOX. ADJUST TO GRADE OF NEW
SIDEWALK. CONNECT NEW ILLUMINATION CONDUCTORS TO EXISTING ILLUMINATION CIRCUIT.
(SEE WIRING DIAGRAM).
O8 INSTALL TYPE 1 JUNCTION BOX.
O9 INSTALL TYPE 2 JUNCTION BOX.
10 INSTALL TYPE 2 INDUCTION LOOP DETECTOR WITH 3 TURNS.
11 DISCONNECT LOOP NEAREST EXISTING STOP —BAR FROM EXISTING LEAD —IN, CONNECT NEW
LOOP TO LEAD —IN.
12 PROVIDE AND INSTALL 1 NEW LOOP AMPLIFIER WIRING HARNESS. INSTALL 3 NEW LOOP
DETECTOR AMPLIFIERS USING 2 EXISTING SPARE WIRING HARNESSES AND 1 NEW WIRING
HARNESS, INSTALL 3 NEW LOAD SWITCHES (PHASE 5 VEHICLE, PHASE 8 VEHICLE, PHASE 6
PEDESTRIAN). MOVE CONDUCTORS SERVING VEHICLE HEADS 4 & 5 FROM PHASE 1 OUTPUTS TO
PHASE 4 OUTPUTS. CONNECT NEW CONDUCTORS FROM NEW VEHICLE AND PEDESTRIAN SIGNAL
DISPLAYS, NEW LOOP DETECTORS, AND NEW OPTICAL DETECTOR TO FIELD TERMINALS AS
REQUIRED (SEE WIRING DIAGRAM),
NOTE: ALL NEW CABINET AUXILIARY EQUIPMENT SHALL BRAND AND MODEL OF EXISTING
EQUIPMENT UNLESS OTHERWISE ALLOWED BY THE CITY OF RENTON.
13 INSTALL LUMINAIRE FOUNDATION WITH CONCRETE PAD (SEE DETAIL IN SPECIFICATIONS).
INSTALL 40 FT. LUMINAIRE POLE WITH 400 WATT HPS LUMINAIRE.
L
I OOP I OCATIONS
LOOP NUMBER
TYPE
SIZE
STATI O N
NE 3RD STREET
DMONDS AVENUE NE
13
2
6' X 6'
9 +58
4000H
51
2
6' X 6'
9 +84
40 FT,
52
2
6'X 6'
9 +98
14 +43
53
2
W X 6'
10 +12
3
81
2
W X 6'
32 FT. RT.
36 +31
82
2
W X 6'
1.92"
36 +17
83
2
6' X 6'
2
36 +03
84
2
61 X 6'
36 +31
85
2
6' X 6'
36 +17
86
2
6' X 6'
36 +03
3
3"
PVC
0.42"
1.92"
NEW CONDUIT.
5
2
1
1
1
4
3"
1.70"
1.92"
EXISTING CONDUIT.
6
2
1
4
3"
1.59"
1.92"
EXISTING CONDUIT,
7
1
2
3"
PVC
0.35"
1.92"
NEW CONDUIT.
8
1
2
3"
PVC
0.35"
NOTES: LOOP DETECTOR STATIONING IS REFERENCED TO EDGE OF
LOOP NEAREST INTERSECTION.
NEW LOOPS SHALL BE CENTERED IN THEIR RESPECTIVE LANE.
WIRE NOTES
LUMINAIRE SCHEDULE
LUMINAIRE
NO.
LUMINAIRE
1. D.
LAMP
WATTAGE
POLE
LOCATION
CENTERLINE OF POLE
TO CENTERLINE OF ROAD
ARM
LENGTH
MOUNTING
HEIGHT
CIRCUIT
NUMBER
1
4000H
40OW HPS
12 +03
35 FT. RT.
8 FT.
40 FT,
A -1
2
4002H
40OW HPS
14 +43
32 FT. RT,
8 FT.
40 FT,
A -1
3
4004H
400W HPS
16 +83
32 FT. RT.
8 FT,
40 FT,
A -1
I
Pv �OPP�R� do
ZGS� � gG � �O b �G`'� �GS� SC, GplJO Gp�O GpNO P��pSt .
COMMENTS
1
3
2
3
1
2
3"
1,54"
1.92"
EXISTING CONDUIT.
2
1
1
1
3
3"
1.21"
1.92"
EXISTING CONDUIT.
3
3
1
2
1
2
3"
1.33"
1.92"
EXISTING CONDUIT.
4
3
3"
PVC
0.42"
1.92"
NEW CONDUIT.
5
2
1
1
1
4
3"
1.70"
1.92"
EXISTING CONDUIT.
6
2
1
4
3"
1.59"
1.92"
EXISTING CONDUIT,
7
1
2
3"
PVC
0.35"
1.92"
NEW CONDUIT.
8
1
2
3"
PVC
0.35"
1.92"
NEW CONDUIT.
9
1
2"
PVC
0.09"
0.87"
NEW CONDUIT.
10
2
2"
PVC
0.18"
0.87"
NEW CONDUIT.
11
1
1-1Z2"
EXISTING CONDUIT.
12
3
1-1/4"
PVC
0.39"
NEW CONDUIT.
13
6
2"
PVC
0.87"
NEW CONDUIT.
14
2
2"
PVC
0.12"
0.87"
NEW CONDUIT.
15
16
17
18
19
GROUNDING SHALL BE IN ACCORDANCE WITH STD. PLAN J -9a.
* USE SCHEDULE 80 FOR ROADWAY CROSSINGS, SCHEDULE 40 FOR OTHER CONDUIT RUNS.
* DOES NOT INCLUDE GROUNDING CONDUCTORS. TaL 2257
I A I f f I I r.
19 18 17 • 15 14 13 12 11 10 • 8 7 14810
• 81
RE00W
FM APPROV 01 AB
dt
BY fL4J '7/ 0 CITY OF RENTON
BY 9V DEPARTMENT OF PUBLIC WORKS
p E01�
ox Signal Notes
Traffic Signal Revision
E]IPIRE.: APRIL26 ,UG, Edmonds Avenue NE at NE 3rd Street
DESIGNED D. HAMLIN MAY 1995
DATE FILE NO
DRAWN D. HAMLIN
Eo
.GALE
CHECK NONE FIELD BOOK -PAGE-
REVISION W APPR. DATE APPROVED SHEET S OF 7
9 10 11 12 13 14 15 16 17 18 19
i