CONSTRUCTION NOTES
1D CONSTRUCT LUMINAIRE POLE FOUNDATION. INSTALL HADCO 14 FT. P -2560 SERIES POST
WITH 100 WATT HPS LUMINAIRE WITH TYPE III DISTRIBUTION.
CONSTRUCT LUMINAIRE POLE FOUNDATION. INSTALL HADCO 14 FT. P -2560 SERIES POST
WITH 100 WATT HIPS LUMINAIRE WITH TYPE V DISTRIBUTION.
03 INSTALL TYPE I JUNCTION BOX (SEE WSDOT STD. PLAN J -1 1 a).
INSTALL SERVICE CABINET FOUNDATION. INSTALL SERVICE CABINET.
O CONNECT TO TRANSFORMER VAULT IN ACCORDANCE WITH PUGET SOUND ENERGY REQUIREMENTS.
LEAVE MINIMUM OF 50 FEET OF NO. 10 CABLE AND GREEN NO. 8 CABLE COILED IN
JUNCTION BOX FOR FUTURE USE.
LUMINAIRE SCHEDULE
LUMINAIRE
N0.
CITY OF RENTON
LUMINAIRE I.D_
NUMBER 1
LAMP
WATTAGE
POLE
LOCATION
CL OF POLE
CURBFACE
MOUNTING
HEIGHT
I CIRCUIT
NO.
REMARKS
1
P0150B
100 WATT
SEE PLAN
5 FT.
14 FT.
1
2 (GATE)
2
P0152B
I 100 WATT
SEE PLAN
5 FT.
14 FT.
1
3
P0154B
I 100 WATT
SCALE FROM PLAN (2)
5 FT.
14 FT.
1
4
P0156B
100 WATT
SCALE FROM PLAN (2)
6 FT.
14 FT.
1
5
P0158B
100 WATT
SCALE FROM PLAN (2)
6 FT.
14 FT.
1
6
P0160B
100 WATT
SEE PLAN
12" CENTERS
14 FT.
1
7
P0161B
{ 100 WATT
SCALE FROM PLAN (2)
6 FT.
14 FT.
1
8
P01638
I 100 WATT
SCALE FROM PLAN (2)
6 FT.
14 FT.
1
9
P0165B
100 WATT
SCALE FROM PLAN (2)
6 FT.
14 FT.
1
(1) NUMBER TO BE AFFIXED TO POLE IN ACCORDANCE WITH CITY OF RENTON STANDARD DETAIL.
(2) FINAL LOCATION TO BE APPROVED BY PROJECT MANAGER PRIOR TO CONSTRUCTION.
SERVICE CABINET (I.D. NO. P0002)
BREAKER AND CONTACTOR SCHEDULE
CIRCUIT
NO.
MAIN BREAKER
AMPS
BRANCH BREAKER
AMPS
CONTACTOR
AMPS
REMARKS
MAIN
50
—
—
1 20 '240 VOLT
1 ILLUM
—
20
30
240 VOLT
2 (GATE)
—
20
—
120 VOLT
I!
1 GREEN NO. 8 (GND)
�4
r, L L
71
WIRE NOTES
RUN
CONDUCTORS
4 3/4" DIA X 21" CADMIUM
PLATED STEEL ANCHOR BOLTS W/
3 N0. 8 'POWER)
1 GREEN NO. 8 (GND)
14" BOLT CIRCLE.
T--
A
I
2" PVC
I
I
l
2 NO. 10 (ILLUM)
2 NO. 10 (GATE)
18" MIN.
I!
1 GREEN NO. 8 (GND)
�4
2 NO. 10 (ILLUM)
1 GREEN NO. 8 (GND)
1 —1 /2" PVC
CLASS 3000 CONCRETE
I
I
8 #7 BARS
I I
—I
EVENLY SPACEDI
I
#4 HOOPS
12" CENTERS
— — —
-� 2" CLEARANCE
3' SQ OR RND
FOUNDATION
DETAIL
r, L L
71
WIRE NOTES
RUN
CONDUCTORS
CONDUIT
3 N0. 8 'POWER)
1 GREEN NO. 8 (GND)
2" PVC
A
4 NO. 10 (ILLUM)
2 NO. 10 (GATE)
2" PVC
1 GREEN NO. 8 (GND)
A
2 NO. 10 (ILLUM)
2 NO. 10 (GATE)
2" PVC
1 GREEN NO. 8 (GND)
�4
2 NO. 10 (ILLUM)
1 GREEN NO. 8 (GND)
1 —1 /2" PVC
NOTE: LATERAL CONDUITS SHALL BE PVC SCH. 40.
STREET CROSSINGS SHALL BE PVC SCH. 80.
Tall-231100-
LEGEND
LIGHTING CONTACTOR CABINET
LUMINAIRE
® TYPE 1 JUNCTION BOX
- - - - - -- CONDUIT
— — — — TRENCH, UNDERGROUND POWER
ssgw'Qio��
CITY OF RENTON
I DEPARTMENT OF PUBLIC WORKS
Illumination Plan
L�
Roadway Illumination
OL 241999
Blueberry Place Townhomes
DESIGNED D. HAMLIN DAh October 1997 FILE NO
Dye D. HAMLIN
CHECKED seALE NONE FlELD BOOK_PACE_
DAT- APPROVED _ SHECf Z OP 2
C(`ANNrn WIAQ 3 0 2000
m
o�
6
� 1
y
au
N d i
d
a f�
z �