HomeMy WebLinkAboutT-2323051 MOUNTING HEIGHT 15 FEET _j INSTALL DECAL NUMBERS V ERTICALY. INSTALL IN VERY CRY WEATHER 50' F OR ABOVE. NUMBERING EXAMPLES LETTER SUFFIXED CITY OWNED 10 45°� TRAFFIC/ FLOW LETTER PREFIXED PUGET POWER OWNED 1 3/4 -2" N � M � I N � I � DECAL: N REFLECTORIZED GOTHIC GOLD OR WHITE LEGEND ON BLACK STREET LIGHT DETAIL STANDARD DECAL NUMBERING SYSTEM ($ SCALE: NONE 6E(L)805 6E L)805 2" N.P.S. SUPFITTER — BRACKET CABLE 2 2" BY 3/4" REDUCING WASHER 3/4" ROMEX CONNECTOR T WITH LOCKNUT SINGLE OR DOUBLE MAST 3iq ARM AS REQUIRED FOR DOUBLE MAST ARM, INSTALL 2ND CABLE BETWEEN LUMINAIRES WHEN BOTH LUMINAIRES ARE ON SAME CIRCUIT MAST ARM WIRING DETAIL DETAIL STRAIN RELIEF 6 SCALE: NONE 6E(L)804 6E L)805 7RO °7C / -2J27 JUNCTION BOX DIMENSION TABLE M A ITEM R K TYPE ALTERNATE A BOX TYPE 1 ALTERNATE B TYPE 2 A Box Outside length 22" 22" 33" B Box Outside Width 17" 17" 22 1 2" C Box Inside Length 18" 19" 28" D Box Inside Width 13" 14" 17" E Lid Length 18" 18 "' 26 1/2" F Lid Width 13" 13" 17" G Box De th 12" 12" 12" H Lid & Frame De th 5/16" 5/16" 5 16" J Wall Thickness Min. 1 1 2" 1 1/2" 1 1/2" K Wire Reinforcement W -3 W -2.5 W -2.5 L Legend I See Detail I See Detail See Detail m o A C I I I N - o z PLAN VIEW car I LK ITEM MATERIALS ELEVATION VIEW Box 6000 PSI concrete See Notes * Frame Diamond Plate Steel - A786 * Lid Support 1 8'Min. Thick Sled C, L or L - A36 1 Lid Diamond Plate Steel - A786 Anchors Steel Wire or Tee Plate a f Reinforcement ASTM A -82 Steel *GALVANIZED STEEL - „o,,,, fi�^Pe LEGEND DETAIL(— u — N LIGHTING T S1.6 TYPICAL JUNCTION BOX INSTALLATION DETAILS TELEMETRY TRAFFIC SIGNAL SYSTEM LEGEND L° m TYPE '1' BOX letters riU f /8' waN G°n° afi Pamard f "rm�n9 T-11! TYPE 'll' BOX e x x3 /tfi. llo,q L HOOK DETAIL PLAN SYMBOLS ILLUMINATION SYSTEM LEGEND NOTES: All dimensions are minimum. Exact configurations vary among different manufacturers. The noted lid thickeners ov °-ali minimums. The Diamond Pattern for Type 1 or Type 2 Boxes shall be 28% minimum of overall thickness. Lid support members shall be welded to the frame. 4000PSI concrete is allowed if box reinforcement consists of 6 X 6 - W3 X W3 welded wire fabric welded to the frame. When noted in the contract. Type 2 and Type 3 Boxes shall be provided with 12" deep extension boxes. When noted in the contract. Type 2 Boxes shall be provided with a 10' X 27 1/2” 10 gage divider plate complete wit F fasteners. Non - concrete Boxes may be submitted for approval. Evaluation will include an H -20 Locd Test. DETAIL JUNCTION BOX 4 SCALE: NONE 6E(L)6 6E L)805 • .•.T FILL INLINE SPLICE WYE SPLICE SPLICE KIT —DIAMETER = 7/8" 4_7/8•• LOAD LINE 1 /q^ FUSE 1/4" i 1/8" po 0 1/8" CUTTING RINGS FUSE KIT DETAIL FUSE KIT Ac SPLICE KIT 3 SCALE: NONE 6E(L)804 6F_(L)805 TAL232305 Aft KULL 15V III T' n N f WE � n M --A • z� • • z 7, /-} / . T- 2 . - , e,- O v A N N O 0 O F11 O O 0 O rn I g g y m� o� z n 1 o� w N 0 C) o w 91 r 0 r F7 CD r n (J-) FTI D — � 0 1I1 Fl FT-1 ___l c D Z7 omo AS B U LT D r < m � m_ -o _ ° >> 4 z r— F11 oo� Cn Z ---- v-------- - - - - -k RECOMMENDED BY ; M M v `FOR APPROVAL BY i o -- to- -- -- to- --- --to tar ��Wgyjy/ I- ✓�t "�� RECORD DRAWING INFORMATION COMPILED FROM CONTRACTOR'S RECORDS. LICENSEE o gF��02y° �v OVAL IS NOT RESPONSIBLE FOR ACCURACY OR COMPLETENESS OF CONTRACTOR'S RECORDS. I®�C�J/�J16- - ®--- ®/Yy- -j-� ®— g EXPIRES: 10/05/'99 RECORD C ®R D D R A Y Y' 1 V G I raera��ssrrar �o O C3i N � /-} / . T- 2 . - , e,- O v A N N O 0 O F11 O O 0 O rn I g g y m� o� z n 1 o� w N 0 C) o w 91 r