LUMINAIRE SCHEDULE
CITY
ID N0.
LUMINAIRE
INAI `
STATION
OFFSET
DIST - TYPE -WATT
CIRCUIT
N0.
POLE
HEIGHT
ARM
LENGTH
REMARKS _
2161 F _
T '
11+65
23.5' LT.
M -C -III 250W
LTG1
35'
8.5
WITH PHOTO -CELL
2163F
2
134-00
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
2 - #8, 3 - #12
2165F
3
14 +40
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
2167F
"4
15 +80
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
W
2169F
5
17 +20
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
— >_ roi
2171 F
6
18 +60
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
2173E
7
19 +90 <.
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
2175F
8
21 +00
23.5' LT.
M -C -III 250W
LTG1
35'
8.5'
r
m
RUN Q
(c7 O
U rn Lo
CONDUCTORS
1
1 1/2"
n N
1 1/2"
2 - #8
Z (O N
1 1/2"
SPARE
LTG2
t7 -
2 - #8, 3 - #12
3
1 1/2"
= O r)
2" SCH 80
2 - #8, 3 - #12
F- O
D 00
2" SCH 80
SPARE
8
Ornco
2 - #8, 3 - #12
5
2"
(n o
r-9t
z0
��w0�
D� -
Z
\
X
W z
Z Q
w
Li
w <
W
F=--
rn o
��
— >_ roi
f7 J n
�^
W
MZ
W(o
°w�
`TRO - sii -1��8
`I
w o
fe Y12- _ j
6.
r� I
ILLUMINATION CONSTRUCTION NOTES
O CONSTRUCT FOUNDATION AND INSTALL LUMINAIRE AND TYPE 1 JUNCTION BOX PER CITY OF RENTON STANDARD PLANS J004 AND 1007,
AND DETAILS SHOWN ON THIS SHEET.
INSTALL APPROPRIATE JUNCTION BOX PER DETAIL ON THIS SHEET.
O3 CONSTRUCT FOUNDATION AND INSTALL TYPE III SERVICE CABINET AT STATION 11 +08, 30' RT. TO BACK OF FOUNDATION, PER CITY OF
RENTON STANDARD PLANS J010, J011 AND J012. SEE BREAKER SCHEDULE ON THIS SHEET. LABEL SERVICE CABINET WITH NUMBER °0007"
® INSTALL CONDUIT AND CONDUCTORS PER WIRE NOTE FROM SERVICE INTO POWER VAULT. COORDINATE WITH PUGET POWER FOR
ELECTRICAL HOOK -UP AT POWER VAULT.
WIRE NOTES
RUN Q
CONDUIT
CONDUCTORS
1
1 1/2"
2 - #8, 1 - #8 GROUND
1 1/2"
2 - #8
2
1 1/2"
SPARE
LTG2
1 1/2"
2 - #8, 3 - #12
3
1 1/2"
SPARE
2" SCH 80
2 - #8, 3 - #12
4
2" SCH 80
SPARE
8
2"
2 - #8, 3 - #12
5
2"
SPARE
BREAKER SCHEDULE
BREAKER
MS)
(AMPS)
CONTACTOR
AMP
REMARKS
MAIN
100
3" SCH 80
LTG1
20
20
SPARE
LTG2
20
20
FUTURE
SIGNAL
40
FUTURE
I t
F� `r
i
r
WIRE NOTES
RUN Q
CONDUIT
CONDUCTORS
6
2"
3 - #4
3" SCH 80
SPARE
3" SCH 80
SPARE
7
2" SCH 80
SPARE
2" SCH 80
SPARE
3" SCH 80
SPARE
3" SCH 80
SPARE
8
2" SCH 80
SPARE
2" SCH 80
SPARE
r-9t
2" SCH 80
SPARE
ALL CONDUIT SHALL BE PVC SCHEDULE 40 UNLESS
OTHERWISE NOTED.
So'
SIDE VIEW
AI I2 4� ,�-,Tn L -049
w
w
w
p
pl
1
II
STREET LIGHT POLE
JUNCTION BOX
PLAN VIEW
LIGHTING STANDARD & JUNCTION BOX
PLAN VIEW
INDIVIDUAL JUNCTION BOX
SHEET 19
r
24�X
I