HomeMy WebLinkAboutT-269219I e a F. LEGEND: GENERAL NOTES: EXISTIND NEW A CONTRACTOR SHALL FIELD VERIFY FOR EXISTING UNDERGROUND PVC CONDUIT AND RECEIVE MOOT MAINTENANCE APPROVAL PRIOR TO REUSING EXISTING CONDUIT -" ■ TYPE I JUNCTION BOX ON PROJECT. -.. ■ TYPE 2 JUNCTION BOX S. HDPE CONDUIT USED FOR DIRECTIONAL BORINGS. HEAVY DUTY JUNCTION BOX C. INSTALL ONE VCONDUIT VATH CONDUCTORS BETAEEN EACH LIGHT STANDARD ■ (SEE SCHEDULE FOR TYPE) AM ITS JUNCTION BOX PER MDOT STD. PLAN J- 25.]0-00. O TYPE 8 JUNCTION BOX D. ELECTRICAL POWER UTILITY IS PUGET SOUND ENERGY (PSE). -. UTILITY REPRESENTATIVES: ,. IN NEMA/BAR■ER JUNCTION BOX SERNIEE2INSTT]AL�18 NS:MARISSA JOHNSON -_ CAMERA CABINET OVMERHEAD �SNTENFERENC�P�(NZOVIID WILCOX ... ® PULL BOX PHONE X2]0 " OAS WUCOOXGPSSECOM ELECTRICAL SERVICE CABINET E. SHEET 110002 AND ILD812 NOT USED. CONTROLLER CABINET F. DRAWNG 1100.20, ILDJF21 AND 11O 2 ALL APPLY TO SURFACE MOUNTED NEMA 4X .. GI TRANSFORMER CABINET JUNCTION BOXES FOR UNDERDECK LUMINAIRES ON EXISTING BRIDGE STRUCTURES ONLY. "._ .j;( SINGLE UGHT,METAL STANDARD 0-0 DOUBLE LIGHT, METAL STANDARD i#( TEMPORARY TIMBER LUMINAIRE _. $D UNDERDECK LIGHT DECORATIVE WALL LIGHTS DECORATIVE LIGHT STANDARD ABBREVIATIONS: O POWER POLE DSIRM = DATA STATIONIMMP METER — AERIAL TRIPLEX CM - CLOSED CIRCUIT TELEVISION - - - - - -- CONDUIT VMS - VARIABLE MESSAGE SIGN CONDUIT BORING -X VIDEO DETECTOR CAMERA `SEE ITS DRAWNG RS CONDUIT, PB, AND CV {il CONSTRUCTION NOTE WRE NOTE 1 1 CIRCUIT 0 CONSTRUCTION NOTES 1. REMOVE LUMINAIRE STANDARD AND FOUNDATION. REMOVE CONDUIT AND CONDUCTORS TO NEAREST JUNCTION BOX BACK FILL. RETURN CRY OF RENTON LUMINAIRES AND STANDARDS TO THE CITY OF RENTON EXCEPT AS OTHERWSE NOTED. 2. REMOVE JUNCTION BOX AND ASSOCIATED CONDUCTORB.ABANDON CONDUIT, BACKFILL, PRIOR TO REMOVAL VERIFY IF EXISTING CONDUIT CAN BE REUSED AS PART OF THIS PROJECT. CONTRACTOR SHALL CONFIRM REMOVAL WTH ENGINEER IF CONTENTS INCLUDE ELEMENTS BEYOND POWER AND LIGHTING CIRCUITS SCHEDULED FOR REMOVAL. EXISTING JB LOCATIONS ARE APPROXIMATE AND SOME ARE BASED OFF OLD POSE. 1 SEE ITS PLAN FOR CONTINUATION OF CIRCUIT AND TRANSFORMER DETAILS. 4, COORDINATE CONDUIT INSTALLATION WTH THE CONSTRUCTION OF RETAINING MILL 6. CONSTRUCT FOUNDATION AND INSTALL TYPE "E" SERVICE PER THE STANDARD PLAN Jki WTH THE EXCEPTION THAT THE TRANSFORMER SHALL BE RATED AT THE WA SHOWN ON THE BREAKER SCHEDULE. INSTALL A SECONDARY CIRCUIT BREAKER WTH AMPERAGES AS SHOWN ON THE BREAKER SCHEDULE. COORDINATE POWER CONNECTION WTH THE UTILITY COMPANY THROUGH THE ENGINEER, J. BAURAN L L) CONSTRUCTION NOTES CONTINUED 6. INSTALL HOUSE SIDE SHIELDS FOR ALL LUMINAIRES ON THIS LUMINAIRE STANDARD. 7. EXTEND NEW RACEWAY AND CONDUCTORS TO EXISTING JUNCTION BOX. SPLICE NEW CONDUCTORS TO EXISTING CONDUCTORS. S. SEE MOOT STANDARD PLAN J -16B FOR TRANSITION OF CONDUIT FROM BARRIER TO GROUND. B. REMOVE EXISTING 310W HPS LUMINAIRES ON EXISTING LIGHT STANDARD AND REPLACE WITH NEW KIXV HPS LUMINAIRES. 10. NEW LUMINAIRES ON NEW SIGNAL POLE;SEE SIGNAL PLANS FOR CONDUIT AND WRING. 11. REMOVE LUMINAIRE STANDARD AND BARRIER FOUNDATION, REMOVE CONDUIT IN LENGTH OF REMOVED MEDIAN BARRIER, INTERCEPT EXISTING CONDUIT . REPLACE VATH NEW CONDUIT TO JUNCTION BOX. PULL AND CONNECT NEW WIRING FROM EXISTING JUNCTION BOXES IN MEDIAN BARRIER TO JUNCTION BOX FOR TYPICAL PROPOSED LIGHT IN MEDIAN BAR ■ER SEE SHEET 11-1 1& 12. INTERCEPT EXISTING RACEWAY AND EXTEND TO NEW JUNCTION BOX. 13. EXTEND RACEWAY AND CONDUCTORS TO EXISTING POWER ON EXISTING POLE. 14, SEE DRAWNG PVD00B FOR ILLUMINATION FOUNDATION DETAILS INCLUDING TRAFFIC BARRIER MOUNTED JUNCTION BOX. 15. INSTALL 4 DEGREE CONDUIT BENDS INTO AND OUT OF BARRIER; CONDUIT BENDS TO TOTAL LESS THAN 270 DEGREES. 16, INTERCEPT EXISTING CONDUIT IN SHOULDER AND EXTEND TO NEW JUNCTION BOX MOUNTED IN BARRIER FOUNDATION. SEE SHEET ILD -D1B. 17, REMOVE EXISTING UNDERPASS LUMINAIRES. 15. INSTALL NEW UNDERPASS LUMINAIRE ON PIER. 13, REMOVE EXISTING PULLBOX AND INSTALL CONDUIT, M. EXISTING LUMINAIRE ON PSE UTILITY POLE; POE TO REMOVE LUMINAIRE. 21. INSTALL NEW UNDERPASS LUMINAIRE TO BRIDGE UNDER STRUCTURE. 22. REMOVE EXISTING SIGN L1GHT(S). REMOVE CONDUIT TO NEAREST IN-GRADE PULLBOX REMOVE WRING TO CIRCUIT NNECTION POINT OR TO BREAKER IN SERVICE CABINET. 23 REMOVE CIRCUIT TO EXISTING ITS EQUIPMENT. REMOVE CONDUIT TO NEAREST N IN -GRADE PULLBOX. REMOVE WRING TO CIRCUIT CONNECTION POINT OR BREAKER I SERVICE CABINET N. REUSE EXISTING 1 12" CONDUIT FOR POWER TO CC532 CABINET THAT IS TO BE REMOVED. 25. REMOVE EXISTING PULLBOX AND ABANDON CONDUIT BELOW GRADE. 23. EXISTING POLE AND MASTARM TO REMAIN, CONVERT THE EXISTING LUMINAIRE FROM 240V TO 480V IN A MANNER APPROVED BY THE ENGINEER. 27. REUSE EXISTING 2 N CONDUCTORS. 28. SPLIT CIRCUIT F AT PBEX2 MAINTAIN CIRCUIT F TO ITS LOADS NORTH OF PBFX2. CONNECT NEW CIRCUIT D FROM 3UA-2023 TO WRES OF FORMER CIRCUIT F GOING TO ITS LOADS REMOVED SOUTH OF PBEX2. 20. INTERCEPT CONDUIT AND WRING TO EXISTING STREET LIGHTS ON & PUGET DRIVE AT NORTHEAST CORNER OF TALBOT ROAD AND S PUGET DRIVE AND EXTEND TO NEW PULLBOX PBR54. 30. REMOVE EXISTING CRY OF RENTON SERVICE CABINET. 31. SPLICE NEW AND EXISTING CONDUCTORS ON THE SAME CIRCUITS IN JUNCTION SOX. M. ROUTE CONDUIT UNDER SIDEWALK 'AND AROUND THE NORTH END OF RETAINING WALL A. ]2H CONTRACTOOR WILL REMOVE NEVI LIGHT AS NEEDED FOUNDATION ASSOCIATED JUNCTION BOX CONDUIT AND WRING AT THE NEW LOCATION IN ACCORDANCE WTH THE PLANS. CITY OF RENTON DULL RE- INSTALL AND ENERGIZE LIGHT STANDARD 72H ON NEW FOUNDATION, CITY OF RENTON REQUIRES TWO WEEKS ADVANCE NOTICE BEFORE REMOVING AND BEFORE RE- INSTALLING LIGHT STANDARD 72H. M. INTERCEPT DUSTING CONDUIT IN SHOULDER AND INSTALL NEW TYPE 4 JUNCTION BOX IN SHOULDER. 35. REMOVE AL LIGHTING CIRCUITS FROM EXISTING JUNCTION BOX, MAINTAIN AND PROTECT SIGNAL INTERCONNECT CABLES INSIDE W. REPLACE EXISTING CITY OF RENTON LUMINAIRE ON SIGNAL POLE WTH LIKE LUMINAIRE WTH 240V BALLAST, 37. ROUTE SPARE CONDUIT TO ITS JUNCTION BOX JUST NORTH OF WMINARE SRO; SEE DRAWNG TS41-0S 38. SEE DRAW NO P 26 FOR ILLUMINATION FOUNDATION DETAILS INCLUDING TRAFFIC BARRIER MOUNTED JUNCTION BOX 30. INSTALL NEW JUNCTION BOX INTERCEPTING EXISTING CONDUITS TO EXISTING POLES A53H AND OSSH. SPLICE EXISTING WRES INTO NEW WRES IN THE JUNCTION BOX. 1-6 TO SIR 169 STAGE 2 - WIDENING AND SIR 615 INTERCHANGE ILLUMINATION LEGEND AND NOTES