Loading...
HomeMy WebLinkAboutT-271903a 6 i I m rn 82 SS SIZE INCHES TWIST PAIRS DET 2CS PRE -EMPT 3CS SIG HD 5C INTER- CONNECT POWER #8 REMARKS 1 SAWCUT 2 SW 27TH ST. GENERAL NOTES: 23 -�1 1. ALL VEHICLE SIGNAL HEADS SHALL BE CONVENTIONAL HEADS WITH TUNNEL VISORS AND U W I Q 4 SQUARE DOORS, EXCEPT WHEN NOTED. 0O J, 2. ALL PEDESTRIAN SIGNAL HEADS SHALL BE FIBER OPTIC HEADS WITH TYPE E MOUNTING 0 3 SAWCUT HARDWARE. PEDESTRIAN PUSH BUTTONS AND SIGNS SHALL CONFORM TO CITY OF RENTON (/1 n �I C ¢7 STANDARD PLAN J024 AND J025. z_ 4 1 1/2 _ ~ 1- Z F 3. ALL VEHICLE SIGNAL HEADS SHALL BE TYPE M MOUNTED, UNLESS OTHERWISE NOTED. r• LLJ �t _ 08 5 CV :2 _� 4. ALL DETECTOR LOOPS SHALL BE 6 -FOOT BY 6 -FOOT. LOOPS ARE TO BE CENTERED IN LLI O J TYPE SIGNAL POLE THEIR RESPECTIVE LANES AND LOCATED AS SHOWN BY TYPICAL DIMENSIONS, UNLESS >> Cr� 1 1/2 OTHERWISE NOTED. ~ LIND AVE. SW S4 SIGNAL DISPLAYS O_ z Q 5. ALL SIGNAL POLES SHALL HAVE A POLE MOUNTED TERMINAL BOX. O DETECTOR Z z 6. JUNCTION BOX AND CONDUIT LOCATIONS SHALL BE FIELD ADJUSTED IN ORDER TO PLACE Z SW 27TH ST. S5 2 PARALLEL CONDUITS IN ONE TRENCH. w STREET LIGHT 9 LJ Q 7. REMOVE AND SALVAGE EXISTING HARDWARE, LUMINAIRES, AND POLES, AND DELIVER TO > U 0 IV 4 THE CITY OF RENTON SHOPS. Q Lv -1 3 HEADS N0. Q 8. THE LOCATION OF CONDUIT AND JUNCTION BOXES SHOWN ON THESE PLANS ARE FOR Z W z 3 GRAPHIC REPRESENTATION ONLY. JUNCTION BOXES SHALL BE SET OUTSIDE WHEEL - z F- 2 CHAIR RAMP AREAS. JUNCTION BOX LOCATIONS SHALL BE SUBJECT TO APPROVAL Z C0 12 BY THE ENGINEER. 9. LANDSCAPING TO BE REPAIRED TO ORIGINAL CONDITION OR BETTER. RE I J I 1 i i 6 I 1 1 I it I I I I � I 1 � I I L % .IG 46 45134 li' I 1 I u j I� 2 SW 27TH ST. ,6 2 — I E �Q — ..— .. —.. —.. — ..— ..— ..�R /W— — ..— ..— .. —.. —.. �. 47,/II z w EXIST. TYPE II - -- UW as / � oI ° 4 cE co E fir �E -- -- - -- col C - 51/2 34.0' II S2- -m � 4 a 65 134.0' 11112.0' 0 1 63 18.0 61� 1 E6 - - - 2 64 3 - - -- T ° - — SE N� R nl 1 ° W o _ _ y - ------------------ - - - - -- 4 - - - - -- - - - -- ----------- - - - - - -- - - - -- - -- _ 8 +02 6 3 ..... — .. R/W — FUTURE SIDEWALK �70 0 it - X5'_9 CS - CONDUCTOR SHIELDED 2 21 7 I I _ rro I °ZI Zl of Ir c I D: a a a 0 m O i� CONDUIT AND WIRING SCHEDULE 82 SS SIZE INCHES TWIST PAIRS DET 2CS PRE -EMPT 3CS SIG HD 5C INTER- CONNECT POWER #8 REMARKS 1 SAWCUT 2 SW 27TH ST. 1 23 -�1 3 -- -- 2 SAWCUT 4 C ,A / HEADS N0. 62 Of Of 77 11 3 SAWCUT 3 � Z G3 I ¢7 66, 67, 86, 87 4 1 1/2 t LANE USE SIGNAL HEAD 04 � y 08 5 1 1 1/2 NEW STREET NAME SIGNS 7 TYPE SIGNAL POLE 6 1 1/2 1 SIGN ON MAST ARM LIND AVE. SW S4 SIGNAL DISPLAYS 7 1 1/2 VEHICLE HEADS 3 DETECTOR — 8 3 SIGNAL SIGNAL CONTROLLER SW 27TH ST. S5 2 4 STREET LIGHT 9 2 Y FT-1 FIBER OPTIC TELEMETRY BOX 4 EXISTING CONDUIT 10 3 3 HEADS N0. 4 EXISTING CONDUIT 11 3 2 HEADS NO. 22, 41, 42 EXISTING CONDUIT 12 3 62, 81, 82 EXISTING CONDUIT 13 3 4 31/81 EXISTING CONDUIT 14 2 51/21 2 EXISTING CONDUIT 15 3 3 4 2 16 3 4 17 3 6 EXISTING CONDUIT 18 3 8 EXISTING CONDUIT 19 2 1 4 EXISTING CONDUIT 3 6 20 3 8 2 2 STREET LIGHT POWER 3 8 21 3 6 4 2 2 1 CONTROLLER INTERCONNECT 6 -PR F23 2 2 CONTROLLER POWER 243 2 SPARE INTERCONNECT CONDUIT 3 SPARE INTERCONNECT CONDUIT 25 3 3 2 1 4 1 2 40tOO I I I I 31/81 82 SS -� 5 — 1 12SI1 39 +00.5/0 TYPE I JUNCTION BOX TYPE II JUNCTION BOX o------------------------------------------------ - - - -m 1 01 WATER MH STA. 38 +52.50 LIND AVE. SW STA. 10 +00.00 2.0' 24 2 SW 27TH ST. 1 23 -�1 3 -- -- 11/61 02 TYPE II J -BOX � • C ,A / HEADS N0. 62 Of Of 77 11 10 S4 a / _ > A 71/415 � Z G3 I 44' ARM I 2.0�' g 2 8 81 L DR 'N MH 18.0' �gq 2 83 I- 1 r LIGHTING CONTACTO c 'J V" NER H LIGHTING CONTACTOR 3 0 L 3 V l III I I W I I I it 37 +00 I III 134.0' 85 g6 lu C / 5 I I I - I 1 I I I I I J i I (� I I� I I � I I I I 1 I III I i I II 6 I I •I I I I I CONSTRUCTION NOTES: 10 INSTALL NEW SIGNAL POLE FOUNDATION, TYPE III SIGNAL POLE WITH A 44 FOOT MAST ARM. INSTALL TWO NEW SIGNAL HEADS (TYPE M MOUNT), TWO FIBER OPTIC PEDESTRIAN SIGNAL HEADS WITH TYPE E MOUNTING HARDWARE, TWO PEDESTRIAN PUSH BUTTONS WITH SIGNS, ONE TERMINAL BOX, ONE STREET NAME SIGN, AND ONE LANE USE SIGN. INSTALL ONE DUAL INDICATION PRE- EMPTION DETECTOR. 02 INSTALL NEW SIGNAL POLE FOUNDATION, TYPE II SIGNAL POLE WITH A 56 FOOT MAST ARM. INSTALL ONE LANE USE SIGN, TWO NEW SIGNAL HEADS (TYPE M MOUNT), TWO FIBER OPTIC PEDESTRIAN SIGNAL HEADS WITH TYPE E MOUNTING HARDWARE, TWO PEDESTRIAN PUSH BUTTONS WITH SIGNS, ONE TERMINAL BOX, INSTALL TYPE III CUTOFF OPTICS, 400 WATT HIGH PRESSURE LUMINAIRE, ONE STREET NAME SIGN. 03 INSTALL NEW SIGNAL POLE FOUNDATION, TYPE III SIGNAL POLE WITH A 46 FOOT MAST ARM. INSTALL ONE LANE USE SIGN, TWO NEW SIGNAL HEADS (TYPE M MOUNT), TWO FIBER OPTIC PEDESTRIAN SIGNAL HEADS WITH TYPE E MOUNTING HARDWARE. TWO PEDESTRIAN PUSH BUTTONS WITH SIGNS, ONE TERMINAL BOX, ONE STREET NAME SIGN. ® INSTALL NEW SIGNAL POLE FOUNDATION, TYPE II SIGNAL POLE WITH A 56 FOOT MAST ARM. INSTALL TWO NEW SIGNAL HEADS (TYPE M MOUNT), TWO FIBER OPTIC PEDESTRIAN SIGNAL HEADS WITH TYPE E MOUNTING HARDWARE, ONE ONE TERMINAL BOX, DUAL INDICATION PRE- EMPTION DETECTOR. INSTALL TYPE III CUTOFF OPTICS, 400 WATT HIGH PRESSURE SODIUM LUMINAIRE, ONE STREET NAME SIGN, AND ONE LANE USE SIGN. SO INSTALL NEW CONTROLLER FOUNDATION, PAD, AND CONTROLLER CABINET TYPE P. © RELOCATE TYPE 11 JUNCTION BOX, AND EXTEND CONDUITS AS NECESSARY. 07 INSTALL ACE- 20ODSG (TELCO GREEEN COLOR) CABINET FOR FIBER OPTIC CONNECTIONS. ® REMOVE EXISTING TELEMETRY CABINET. EXTEND EXISTING CONDUITS TO NEW SIGNAL INTERCONNECT TELEMETRY CABINET. PULL EXISTING INTERCONNECT WIRES INTO NEW TELEMETRY CABINET AND TERMINATE ON PANELS. � 6 -� 5 — — — —.. R/W 4 — ..— ..— ..— ..— ..— .. —.._ 0 TYPE I JUNCTION BOX TYPE II JUNCTION BOX o------------------------------------------------ - - - -m 1 01 WATER MH �- 24 2 26 1 23 134.0' 25 3 -- -- � 02 TYPE II J -BOX � • _..— ..— .._..— — _ R /W — ..... ,A / HEADS N0. Ta 271! 90 *3 SIGNAL PLAN LEGEND PEDESTRIAN HEADS LANE USE SIGN PHASING SEQUENCE m Q TYPE I JUNCTION BOX TYPE II JUNCTION BOX 17.89" LEFT TURN YIELD 01 ¢5 16.08" ON GREEN � VEHICLE SIGNAL HEAD FIBER OPTIC> � 02 ¢6 -� ► PEDESTRIAN SIGNAL HEAD HEADS N0. R10 -12 VEHICLE PRE- EMTION HEAD 26, 27, 46, 47 24 " X 3v" St, S2 G3 I ¢7 66, 67, 86, 87 �► LANE USE SIGNAL HEAD 04 � y 08 � TYPE I POLE NEW STREET NAME SIGNS TYPE SIGNAL POLE SIGN ON MAST ARM LIND AVE. SW S4 SIGNAL DISPLAYS VEHICLE HEADS DETECTOR — m SIGNAL SIGNAL CONTROLLER SW 27TH ST. S5 R R STREET LIGHT Y Y FT-1 FIBER OPTIC TELEMETRY BOX G G FIBER OPTIC ` -c HEADS N0. DUAL MODE HEADS NO. 22, 41, 42 62, 81, 82 11/61 31/81 51/21 71/41 I i' Ij 445 ROLL 159