GENERAL ILLUMINATION NOTES
1. CONSTRUCT CONCRETE PAD FOR PROPOSED STREET LIGHTING
AND JUNCTION BOX PER CITY OF RENTON STANDARD PLAN
J014 AND J015.
2. ALL PROPOSED ILLUMINATION CONDUIT RUNS (TRENCH) SHALL BE
LOCATED 6' FROM BACKOF CURB EXCEPT AT WALL.
3. REFER TO SIGNAL PLAN FOR ILLUMINATION CONDUIT
AT SIGNALIZED INTERSECTION.
4. CONSTRUCT LIGHTII.0 UNDERGROUND SYSTEM PER CITY
OF RENTON STANDARD PLAN J007.
5. ALL LUMINAIRE POLE BASES REMOVED SHALL BECOME THE
PROPERTY OF THE CONTRACTOR. ALL OTHER UTILITY ITEMS
REMOVED SHALL BECOME THE PROPERTY OF THE CITY (EXCEPT
WHEN WORK IS DONE BY OTHERS) AND SHALL BE SALVAGED
IN ACCORDANCE WITH THE SPECIFICATIONS.
6 Q
❑ILLUMINATION CONSTRUCTION NOTES
1. FURNISH AND INSTALL ONE COBRA HEAD LUMINARE WITH POWER
DOOR AND MEDIUM TYPE III CUTOFF OPTICS, 400 WATT
F!, 1 .1-1
PRESSURE SODIUM LAMP, AND FIXED BASE TYPE. MOUNTING
HEIGHT AND ARM LENGTH SHALL BE AS SHOWN IN ILLUMINATION
SCHEDULE. CONSTRUCT FOUNDATION PER WSDOT STD. PLAN J -1b
AND THE SCHEDULE BELOW. FOUNDATION DEPTH SHALL BE AS
INDICATED IN THE ILLUMINATION SCHEDULE. INSTALL TYPE I
JUNCTION BOX ADJACENT TO LUMINAIRE PER CITY OF RENTON
STANDARD PLAN J008.
4. INSTALL TYPE I JUNCTION BOX PER CITY nF RFNTON
STANDARD PLAN J008 AND J016.
CONDUIT AND WIRING SCHEDULE
RUN
NO.
Z—\
CONDUIT
CONDUCTORS
1
2" PVC SCH 40
2 - #6, 1 - #8 GROUND
2*
2" PVC SCH 40
PULL WIRE
3
2" PVC SCH 40
2 - #6, 1 - #8 GROUND
*FOR FUTURE INTERCONNECT USE
ROLL # 167 FRI ? 1
OAKESDALE AVENUE SV EXTENSION -PHASE 1B &
ILLUMINATION AND
INTERCONNECT PLAN
SCALE IN FEET
20 10 0 20 40
HORIZ.
-C 1'
I i
ICJ
W
E-
1w
I�
I�
I�?
I U:
18 +00- I CC)
IGO
_-
I i�L '[
1. E. 1, 1 I.. 1.
F
2 �
NOTE:
THE EXISTING TOPOGRAPHIC AND PHYSICAL FEATURES SHOWN ON THESE PLANS
ARE BASED ON:
INFORMATION PROVIDED BY W &H PACIFIC SURVEY 1997
THIS WAS THE INFORMATION AVAILABLE AT THE TIME OF PLAN PREPARATION.
ACTUAL CONDITIONS MAY BE DIFFERENT. THE CONTRACTOR MAY ENCOUNTER
VARIATIONS BETWEEN ACTUAL CONDITIONS AND THOSE SHOWN. THESE VARIATIONS
WILL NOT BE THE BASIS FOR A CLAIM OR EXTRA COMPENSATION.
THE LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE SHOWN IN AN APPROXIMATE
WAY ONLY AND HAVE NOT BEEN INDEPENDENTLY VERIFIED BY THE OWNER OR ENTRANCO
THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES
BEFORE COMMENCING WORK, AND AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL
DAMAGES WHICH MIGHT BE OCCASIONED BY THE CONTRACTOR'S FAILURE TO EXACTLY
LOCATE AND PRESERVE ANY AND ALL UNDERGROUND UTILITIES.
DWG NO.
SHEET
47 OF 69
c`T�) ; 7-22t-?c SCANNED OCT 4 2000