Loading...
HomeMy WebLinkAboutT-28820417 L ob,,, a R Q ry LLJ Q J Q � z m L.LJ Q zz z W CD O Q Z LL f— J Y Q J POLE SCHEDULE LUM. POLE NO. LOCATION POLE OFFSET MOUNTING HEIGHT ARM LENGTH SERVICE CIRCUIT (WATTAGE COMMENT EX. POLE DECAL NO. PROP. POLE DECAL NO. 1 EXISTING EXISTING 3OFT (EX.) 1OFT (EX.) EX. PARK/ GARDEN 25OW EX. I EXISTING POLE TO REMAIN 4802F - 2 11 +03.5 63.SFT RT 30FT (EX.) 8FT (EX.) EX. PARK/ GARDEN 25OW (EX. ) RELOCATE EX POLE AT STA 10 +99 TO PROPOSED POLE 4 LOCATION 4801F - 3 EXISTING EXISTING 40FT (EX.) TOR (EX.) SOUTHPORT RELMIP EXISTING POLE TO REMAIN a803F 48038 4 12 +48.5 56.OFT RT 3OF1 (EX.) 10FT (EX.) NEW SOUTHPORT 1 DOW REIAAIP RELOCATE EX. POLE AT STA 13 +40 70 PROPOSED POLE 4 LOCATION 4804F 4804B 5 12 +50.0 23.5FT LT 25FT (EX.) 10FT (EX. SOUTHPORT tOOW RELAMP RELOCATE EX. POLE AT STA 14 +50 TO PROPOSED POLE 5 LOCATION 4806F 48058 WIRING SCHEDULE (THIS SHEET ONLY) • ALL CONDUIT SHALL BE SC 80 UNLESS OTHERWISE NO ALL CONDUIT SHALL CONTA 8 GROUND WIRE •• EXISTING WIRING BASED ON AS- GUILTS. OTHER WIRES /CONDUCTORS MAY B PRESENT. ; o{ \ Q NO RACEWAY CONDUIT TW PR LOOP DETECT (J12 VEH 2C(SH) E V DETECT 3C(SH) VEH HEAD 5C PED HD/P8 5C(SH) ILLUM #6 ILLUM /8 VEH HEAD 20C INTER #22 12PCC INTER #22 6PCC EX NEW EX EW EX'WEW Ez EW EX E EX ji4NEW EX E E% NEW EX NE EX NEW 1 SAWCUT 1 2 SAWCUT 2 3 1 1/2-(EX) 2 2 4 2" EX 1 1 - 5 11 2' SCH40 4 ., 6 1 1/2' SCH40 2" SCH40 ! 2 ! I ! 1 7 2" SCH40 I 1 8 1 2" SCH40 2 9 , 2 10 2 1 1 /2 2 11 1 1/2- 1 2" t 2 12•• EX 1 1 /2 "(EX CITY OF RENTON STANDARD PLAN REFERENCES SEC, 8, TWP 23N, RGE 5E, W.M. / //' 10 40 \�('j� y 2 1/8" 2" __ ROUND EDGES FOR im PROTECTION / / 0 20 60 N / SCALE: 1" = 20' AB 7/16" DIAMETER THROUGH HOLE 2'• DIAMETER 1` 4 - MASTARM STD. PIPE / SIGNAL TENON DETAIL IEDULE :D. AND / l/ i ✓ j / jam, �! / , / j l/ /� ; / /.;' /' ; ' SIGNAL HEAD ASSIGNMENT /IQs PEDESTRIAN HEADS i r 26, 27 (EX) 46, 47 (EX) v o 1. LUMINAIRE POLES SHALL BE PROVIDED AND INSTALLED PER CITY OF RENTON STANDARD PLANS, PAGES J003, J006, J007, JOO8, J009, J014, AND J015. / ' 2. CONTROLLER AND SERVICE CABINETS SHALL BE PROVIDED AND INSTALLED PER / ��' `• -''h• U O 3 a CITY OF RENTON STANDARD PLANS, PAGES JO10, J011, J012, AND J028. �.. }- z" 3. CONDUCTOR FUSING AND SPLICING SHALL BE PROVIDED AND INSTALLED PER CITY `r OF RENTON STANDARD PLANS, PAGE J013. U co 4. JUNCTION BOXES SHALL BE PROVIDED AND INSTALLED PER CITY OF RENTON _ E STANDARD PLANS. PAGE J016, AND TYPE 3 JUNCTION BOXES SHALL BE DUAL HINGED LID PER WSDOT DETAIL 6.02.. JUNCTION BOXES OUTSIDE OF E PAVED /SIDEWALK AREAS SHALL INCLUDE A CONCRETE PAD PER CITY OF RENTON rnE STANDARD PLANS, PAGE 1008. -J/ /_�1,,g 1% -c Q, 5. SIGNAL AND PEDESTRIAN POLES SHALL BE PROVIDED AND INSTALLED PER CITY OF RENTON STANDARD PLANS, PAGES J021 -JO25. J029, J031, AND J035. 6. SIGNAL AND PEDESTRIAN HEADS AND MOUNTS SHALL BE PROVIDED AND INSTALLED It PER CITY OF RENTON STANDARD PLANS. PAGES J018 -J020 AND J036. 7. EMERGENCY VEHICLE PREEMPTION DETECTORS SHALL BE PROVIDED AND INSTALLED s ` PER CITY OF RENTON STANDARD PLANS, PAGE J032. - '" 0 8. INDUCTION LOOPS SHALL BE PROVIDED AND INSTALLED PER CITY OF RENTON STANDARD PLANS, PAGES J034, J038, AND J039. - 17 Y \ % � 7 \ o 9. SIGNAL HEAD TENONS SHALL BE PROVIDED AND INSTALLED PER CITY OF RENTON STANDARD PLANS, PAGE J037. R CONSTRUCTION NOTES (THIS SHEET ONLY) y \' Oj INSTALL 6'X6' LOOP DETECTOR PER CITY OF RENTON STANDARD PLANS. A 6FT DIAMETER ROUND LOOP DETECTOR MAY BE x SUBSTITUTED EXISTING LOOP LOCATIONS ARE APPROXIMATE. FIELD LOCATE EXISTING LOOPS PRIOR TO SAWCUTTING NEW LOOPS. n 2 REMOVE AND REPLACE EXISTING SIDEWALK AS NECESSARY FOR INSTALLATION OF NEW CONDUIT. SEE BRH PLANS. Z oat R� BREMOVE EXISTING CONDUCTORS AND CONDUIT. 7 \ \ 0 INSTALL SIGNAL HEAD 11 ON EXISTING CAPPED TENON WITH A TYPE M MOUNT PER CITY OF RENTON STANDARD PLANS. PULL 7 NEW 5C FROM HEAD 11 TO THE POLE 1 TERMINAL CABINET AND CONNECT TO EXISTING PHASE 1 SIGNAL HEAD TERMINALS. 11 O INSTALL SIGNAL HEAD 72 ON A NEW TENON AT THE LOCATION SHOWN. DRILL HOLE AND WELD A 2" TENON ON THE MAST ARM 1 mm 5 PER THE SIGNAL TENON DETAIL, THIS SHEET. CLEAN AND TREAT SURFACE WITH GALVANIZED TREATMENT PAINT PER WSDOT 4 / x STANDARD SPECIFICATIONS. SECTION 6- 07.3(4). USE A TYPE M MOUNT PER Cltt OF RENTON STANDARD PLANS. PULL NEW 5C F !/ FROM HEAD 72 TO THE POLE 1 TERMINAL CABINET AND CONNECT TO EXISTING PHASE 7 SIGNAL HEAD TERMINALS. OSPLICE NEW LOOPS 72 AND 74 TO EXISTING PHASE 7 (PLUG P38) 2C(SH) LOOP LEAD -IN CABLE AT THE EXISTING JUNCTION BOX. x o PULL NEW LOOP LEAD -IN AND INTERCONNECT CONDUCTORS THROUGH EXISTING CONDUIT INTO THE CONTROLLER. TERMINATE NEW CP2 O 2C(SH) LOOP LEAD -IN CABLE FOR NEW LOOPS 11, 12, 14, AND 15 TO EXISTING PHASE 1 DETECTOR TERMINALS IN THE a CONTROLLER (PLUG P33). TERMINATE NEW 6PCC TO THE EXISTING INTERCONNECT TERMINAL STRIP. a I,, O8 DISCONNECT EXISTING LOOP 45 AT THE JUNCTION BOX. RE- SPLICE EXISTING LOOPS 46 AND 47 TO THE EXISTING LOOP LEAD -IN / / 27 ✓/ CABLE. o O ABANDON EXISTING LOOP. / �\ 10 RELOCATE EXISTING COBRA HEAD 30 FT ALUMINUM LUMINAIRE POLE (APPROXIMATE STATION 10 +99. RT) ' TO PROPOSED POLE 2 LOCATION AND INSTALL NEW JUNCTION BOX. REMOVE EXISTING FOUNDATION / / / i ,A. m O AND EXISTING JUNCTION BOX. LUMINAIRE POLES 4 AND 5 TO BE REMOVED FROM THE EXISTING LIGHTING CIRCUIT AND SERVED FROM THE NFW SOUTHPORT BLVD TRAFFIC SIGNAL SERVICE CABINET. VERIFY POLE BASE BOLT PATTERN PRIOR TO POURING NEW FOUNDATION. 11 EXISTING LUMINAIRE /SIGNAL POLE TO REMAIN. /// �/✓ 12 RE -LAMP EXISTING LUMINAIRE POLE WITH A 10OW HIPS LAMP. INSTALL NEW JUNCTION BOX AGAINST BACK OF CURB TO AVOID DITCH BACK -SLOPE AND PROVIDE A CONCRETE FOR THE JUNCTION BOX PER CITY OF RENTON STANDARD PLANS, PAGE J008. INTERCEPT EXISTING CONDUIT ENTERING THE LUMINAIRE POLE FOUNDATION- R E APPROXIMATE STATION 13+40. RT) ! 13 PROPOSED POLEN4I LOCATION. E-LA IP WITH AG10OW IPS Of CUREMO0E EXIST AVOID "MERGE" TO / //� I!' AND PROVIDE A CONCRETE PAD FOR THE JUNCTION BOX PER CITY OF RENTON STANDARD PLANS, PAGE v 1008. VERIFY POLE BASE BOLT PATTERN PRIOR TO POURING NEW FOUNDATION. v' / RELOCATE EXISTING COBRA HEAD 25FT ALUMINUM LUMINAIRE POLE AND JUNCTION BOX (APPROXIMATE i 14 STATION 14 +50. RT), TO PROPOSED POLE 5 LOCATION. RE -LAMP WITH A 10OW HPS. LAMP. VERIFY ! ' POLE BASE BOLT PATTERN PRIOR TO POURING NEW FOUNDATION. 4S , 15 TRENCHING SHALL BE PER THE OPEN -CUT METHOD. PER CITY OF RENTON SUPPLEMENTAL SPECIFICATIONS. vs 16 RE- SPLICE EXISTING LOOPS 41. 42. 43. AND 44 TO THE EXISTING LOOP LEAD -IN CABLE AS NECESSARY. \ -" 17 RE- SPLICE EXISTING LOOPS 13 AND 16 TO THE EXISTING LOOP LEAD -IN CABLE AS NECESSARY. / r' 18 ABANDON EXISTING CONDUIT AND REMOVE EXISTING CONDUCTORS. z� 19 REPLACE EXISTING 40 AMP SIGNAL CIRCUIT BREAKER WITH A 50 AMP SIGNAL CIRCUIT BREAKER. .93 12" R 12• R 12" R 12" R l/' ! 61 'it. I / '�T /` 12' Y 7 2" 12' Y 12' f / � I ` 12' G 12" G 12" G 12' G HEADS HEADS HEADS HEADS 13, 82 (EX) 31, 32, 33 (EX) 81 (EX) 12, 71 (EX) 15 41, 42 (EX) 11. 72 (NEW) 1 O ,$ 4 , �; / EXISTING SIGNAL PHASING LEGEND 18 EXISTING a "� (TO REMAIN) EXISTIN PROPOSED DIESCRIPTIO ir? '!1 Iu: / 1L 5•: -. / / '� TI ® TYPE 1 JUNCTION BOX A2�LA D TYPE 2 JUNCTION BOX . 01 BLANK 05 ® TYPE 3 JUNCTION BOX (DUAL HINGED LID) CONTROLLER CABINET /��/ 11 1✓ �� /r \ 02 r BLANK 06 ® ELECTRICAL SERVICE CABINET _ OVLP � J I+ MASTARM - MOUNTED SIGN . / \ _ /�' 03 07 —■ —i DE E EMERGENCY PRE - EMPTION / \ / r - - - -� - -► VEHICLE SIGNAL HEAD 155/ j' —� VEHICLE MOVEMENT I 0. ._r PEDESTRIAN SIGNAL HEAD /► PEDESTRIAN MOVEMENT 13 j / 04 X �-- ® 4 82` 1 N 08 SIGNAL POLE 2 \` 11 - _ PERMITTED LEFT TURN ®i PPB POST \,1 /*,`t PROTECTED LEFT TURN t - -I► ®y-0 PEDESTRIAN HEAD POLE j- GENERAL NOTES MAST ARM SIGNAL POLE Q�'�- JJ-- WITH LUMINAIRE 1_ RED BALL SECTIONS AND ALL ARROW SECTIONS OF NEW VEHICLE SIGNAL HEADS 77 5 SHALL BE LED -TYPE PER CITY OF RENTON SUPPLEMENTAL SPECIFICATIONS. yy----1 72 3`41 ♦ LUMINAIRE POLE ALL OTHER SECTIONS SHALL BE INCANDESCENT PER CITY OF RENTON %/% l/` 7� 33 1 `•.\r / SUPPLEMENTAL SPECIFICATIONS. ALL VEHICLE SIGNAL HEADS SHALL HAVE 12" CONDUIT /CONDUCTOR \ 42 GLASS LENSES, ALZAC REFLECTORS, 5" BACK PLATES, TUNNEL VISORS, AND SHALL BE CAST ALUMINUM. SIGNAL HEADS SHALL USE TYPE M. L, OR LE ❑ LOOP DETECTOR 7� MOUNTS AS NECESSARY TO MAINTAIN 16.5 TO 18.5FT CLEARANCE TO THE '` �- J'3 ROADWAY. NEW PEDESTRIAN HEADS SHALL BE LED -TYPE WITH TYPE E O MASTARM- MOUNTED SIGN NOTE +,. (CLAMSHELL) MOUNTS, UNLESS OTHERWISE NOTED. CONSTRUCTION NOTE O .. 2. SIGNAL STANDARD LOCATIONS TO BE APPROVED BY THE ENGINEER. 3. SIGNAL CONDUIT SHALL BE PLACED IN THE SAME TRENCH AS ILLUMINATION SIGNAL POLE NUMBER O CONDUIT AND /OR OTHER UTILITIES AS DIRECTED BY THE ENGINEER. JUNCTION WIRE NOTE BOXES SHALL BE PLACED OUTSIDE OF THE NEW SIDEWALK WHERE POSSIBLE / UNLESS OTHERWISE DIRECTED BY THE ENGINEER. i - ® LUMINAIRE POLE NUMBER 4. ALL WORK SHALL BE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND SPECIFICATIONS. BNSF CROSSING GATE r / v ( j ; 5. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE BNSF CROSSING CANTILEVER VERIFIED IN THE FIELD BY THE CONTRACTOR AS NECESSARY. 1� /j 1 BNSF CROSSING CANTILEVER \ 42 v4 7, I /"-�1 6. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR AND GATE MATERIALS APPROVAL AT THE EARLIEST POSSIBLE DATE. -53 BNSF CROSSING FLASHING LIGHT 3 1`,� 7. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE (SHOULDER MOUNT POST) CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS ' �A ✓. - 76 = 3 11 ��. °. \ BEFORE COMMENCING WORK, AND SHALL COORDINATE WITH AFFECTED UTILITY ® BNSF CROSSING CONTROLLER AGENCIES THROUGHOUT THE PROJECT. \�-.. PSE WOOD POLE W/ LUMINAIRE 34 \ 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY AND THE CITY OF RENTON IMMEDIATELY UPON DAMAGE. 1ER \ �5� :E*R r T e, CHECK FOR COMPLIANCE 9- CONDUIT COVER SHALL BE PER THE CITY OF RENTON SUPPLEMENTAL s`r:'o1 WASH'';�f TO CITY STANDARDS j SPECIFICATIONS. c :, \ ! _ 10. LIGHT STANDARD FOUNDTAIONS SHALL NOT BE EXCAVATED AND POURED BEFORE A: =:W 9 t 9 35635 O i ' POLE LOCATIONS ARE APPROVED BY THE ENGINEER, TOP OF FOUNDATION :FOr DATE \ \`, SHALL BE FLUSH WITH SHOULDER /SIDEWALK. Ss��NAL'ENO _DATE 11. PROTECT AND MAINTAIN EXISTING SIGNAL EQUIPMENT UNLESS OTHERWISE NOTED ; "2y"0 1 ON THESE PLANS. EXPIRES 12/20/01 SCANNED lU! '