WIRE SCHEDULE
RUN
NO.
CONDUIT
SIZE
CONDUIT
TYPE
WIRE
COMMENTS
1
1 -1/2"
SCH 40 PVC
(2) #8 AWG, (1) #8 AWG (GREEN)
1 +25
2
2"
SCH 80 PVC
(2) #8 AWG. (1) #8 AWG (GREEN)
2
3
1 -1/2"
SCH 40 PVC
2 8 AWG
1 8 BARE GROUND
8'
4
2"
SCH 40 PVC
(3) #2 (SERVICE)
SERVICE
5
1 -1/2"
SCH 40 PVC
(2) #8 AWG
11) #8 BARE GROUND
(3) #12 AWG (RED, BLACK, WHITE)
PHOTO CELL
POLE SCHEDULE
POLE
NO.
LLJ
LLJ
STATION
OFFSET
F-
O
ARM
LENGTH
COMMENTS
1
i�
1 +25
Q
S
8'
ROAD 'B' CENTERUNE
2
26568
5 +75
22'R
25'
8'
cm
o�ggy
s1
26588
4 +65
S
n
6�
Y r
8'
N.E_ 4TH PL CENTERLINE
4
26606
POLE SCHEDULE
POLE
NO.
CITY
ID NO.
STATION
OFFSET
MOUNTING
HEIGHT
ARM
LENGTH
COMMENTS
1
26548
1 +25
22'R
25'
8'
ROAD 'B' CENTERUNE
2
26568
5 +75
22'R
25'
8'
N.E. 4TH PL CENTERUNE
3
26588
4 +65
27'R
25'
8'
N.E_ 4TH PL CENTERLINE
4
26606
3 +35
22'R
25'
8'
N.E. 4TH PL CENTERLINE
W/ PHOTO CELL
0
� w
m a
y
� rc
'- z Tire- a: /- jip l-/
INSTALL LIGHTING
FOR APPROVAL
i$g
GENERAL NOTES
m
FR
1. ALL WORK SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON STANDARD
PLANS AND SPECIFICATIONS AND THESE PLANS.
2. UNLESS OTHERWISE NOTED, THE LOCATION OF FEATURES SHOWN ARE
APPROXIMATE AND THE EXACT LOCATION WILL BE ESTABLISHED BY THE
S
I
I
ENGINEER IN THE FIELD.
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
- N 88' 4'39°"'; W 327 -7 _
3. INSTALL ALL STREET UGHTING MATERIALS SHOWN ON THE PLANS, EXCEPT
1800 -424 -5555
HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES
NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 1 -800- 424 -5555
WHERE NOTED. ALL MATERIALS SHALL BE NEW AND OF THE BEST GRADE OR
DUALITY:
4. THE CONTRACTOR SHALL SUBMIT A REQUEST TO THE CITY OF RENTON FOR
MATERIALS AT THE EARUEST POSSIBLE DATE.
5. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS.
0
d'
W
THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILTTY AGENCIES 48 HOURS
BEFORE COMMENCING WORK AND SHALL COORIDINATE THE WORK WITH THE
UTIUTIES THROUGHOUT THE PROJECT.
I
'
yyb
2
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING
j
I
1
UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY
AND THE CITY IMMEDIATELY UPON DAMAGE.
E
13.7 S WATER
'- 1 EAMENT
SE
7. THE CONTRACTOR SHALL NOTIFY THE CITY OF RENTON FIELD INSPECTION
DIVISION (277 -5570) FOR INSPECTION PURPOSES, 24 HOURS BEFORE
p
8
COMMENCING WORK. NO WORK SHALL BE COVERED UNTIL IT HAS BEEN
EXAMINED BY THE ENGINEER.
1116!—
8. ALL CONDUIT SHALL BE PVC SCHEDULE 40 UNLESS OTHERWISE NOTED.
I
s
9. ALL CONDUIT COVER SHALL BE 24 INCHES.
0
� w
m a
y
� rc
'- z Tire- a: /- jip l-/
INSTALL LIGHTING
FOR APPROVAL
SERM E CABINET
? 0
FR
- .
--T- -- _�
.E. 4TH PL
--. _ - - --
I
I
before you
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
- N 88' 4'39°"'; W 327 -7 _
EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN
1800 -424 -5555
HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES
NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 1 -800- 424 -5555
CO , T _ 2 9_ -icy SCANNED FEB 15 2002
,\
ITO PSE POWER SERVICE
I
1
13.7 S WATER
'- 1 EAMENT
SE
.
p
8
1116!—
s•
ri
i-'-5' PRIVATE
I
STORM DRAIN ii
15 WRTEk EASEMENT
n 1 w
f
EASEMENT .GPI.!
I L1}I
�;
�
� �
-
�
SCALE 1"
it
II
..
ro
I
23.3'
.�-. 3� 3
1
w
1i<
I
ZD
I
i
Z
33 1' —� 22.3'
'.
—10' PRIVATE
DRQNT!
1 i
1
NV 18"
1-
1 1
I
6CONC
I I I
I
\
T1
1 T T
T T
I -
WV -46724 18' WATER
I
EASEMENT
I t'
., -.__..
_.
i
__. i
- EX. C8
-� RIM = 486.10
18" IE= 483.60
TRIM= 489.27
18" a85.s7
q=
T T .
'
88'21'23' W' 1 ". �:.327.Z
-(.-._
T "_C- �"' r.�C- T
'.`-� -- ( - -- -
T
',
T ;. T
T
—�
APPROXIMATE LOCATIO)7
EX
�_A
"�SO - -' --
-SS
APPROXIMATE LOCATION EX. 24"
2+00
-- I -�-
SANITARY SEWER -SS SS L SS SS- I IBS ��S 'SF—SS---
3 +JO
I -_�— 00 __ EX_ 12 -ADS- - _ -- _ ___
INV= 465.P8 5 +00
EX SSMH I
ASS —.--
_- - _ .I- _; _ SSr - -$S.
7 +00
I
8 +00
_ —
RIM = 471.63
INV= 456.00 (24 "E)
N.E. 4TH ST. (SE 128TH ST)
-- - - - --
EX SSMH
RIM = 491.8+
INV= 476.67(24 "E)
7.2005' ®r
RECOMMENDED
FOR APPROVAL
�I L
? 0
FR
AVOID CUTTINC UNDERGROUND
UTILITY LINES. IT'S COSTLY
137(P1RE5 11/30/02 BY
RECOMMENDED
FOR APPROVAL
rsT6iE° BY 1 //-7-10/
S7ONAL ' BY
AVOID CUTTINC UNDERGROUND
UTILITY LINES. IT'S COSTLY
137(P1RE5 11/30/02 BY
Call
NOTE: UNDERGROUND SERVICE (USA)
before you
EXISTING UTILITY LOCATIONS SHOWN HEREON ARE APPROXIMATE ONLY.
IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE
®p9•
EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDER-
GROUND UTILITIES PRIOR TO COMMENCING CONSTRUCTION. NO
REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN
1800 -424 -5555
HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES
NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION.
CALL BEFORE YOU DIG: 1 -800- 424 -5555
CO , T _ 2 9_ -icy SCANNED FEB 15 2002