HomeMy WebLinkAboutT-30200DM Z Y3 N / M �S N 3 4 C C7 q E I STOP BAR LX X X LOOP NUMBER TYPE R3 INDUCTION LOOP TO ADDITIONAL LOOPS WHERE TYPE R1 INDUCTION LOOP LOOP WINDING DETAILS JUNCTION BOX E. �¢ OF AS d� ` � 5 92784 p UST NO LOOP INSTALLATION NOTES 1. INSTALL JUNCTION BOX AND LEAD -IN CONDUIT. 2. SAWCUT LOOP SLOTS AND LEAD -IN SLOTS. 3. LAY OUT LOOP WIRE STARTING AT JUNCTION BOX, ALLOWING 5' MINIMUM SLACK. 4. INSTALL WIRE IN LOOP SLOT AS SHOWN. 5. FINISH LAYING OUT WIRE AT JUNCTION BOX AND IDENTIFY LEADS WIT,H LOOP NUMBER AND "S" FOR START AND "F" FOR FINISH. 6. TWIST EACH PAIR OF LEAD WIRES TWO TIMES PER FOOT FROM ! G; ;P TO JUNCTION BOX. REVERSE DIRECTION OF TWIST FOR EACH SUCCESSIVE PAIR INSTALLED. 7. CONSTRUCT SUPPLEMENTAL SPLICE CONTAINING ANY - SERIES `OR PARALLEL LOOP CONNECTIONS REQUIRED IN PLANS. SUPPLEMENTAL SPLICES ARE SUBJECT TO THE SAME REQUIREMENTS SHOWN FOR THE LOOP LEAD AND SHIELDED CABLE SPLICE. 8. SPLICE LOOP LEADS OR SUPPLEMENTAL SPLICE :TADS 'TO SHIELDED CABLE AS NOTED IN THE PLANS.' 9. COMPLETE INSTALLATION AND TEST LOOP CIRCUnS'OR COMBINATION LOOP CIRCUITS. SEE STANDARD SPECIFICATION 8- 20.3(14)D. 10. FRONT OF LOOP SHALL BE MEASURED FROM BACK OF STOP BAR, OR BACK OF CROSSWALK WHERE NO STOP BAR IS-INSTALLED. 11. CONDUIT FOR LOOP STUBOUT SHALL BE SCHEDULE 40 PVC. 12. LABEL ALL LOOP LEAD IN WIRES WITH BOTH LOOP NUMBER AND LOOP SERIES NUMBER ON T7VE R3 LOOPS AS SHOWN BELOW. LOOP LEAD IN WIRE LABEL: LnXX —XX LOOP NUMBER LOOP SERIES NUMBER DASH S OR F TO CONTROLLER tOSEALANT TO ENCAPSULATE CONDUCTORS — SEE SPECIAL PROVISIONS. 2� LOOP WIRE — #14 AWG. O LEAD —IN WIRES: (SEE INSTALLATION NOTES) THREE PAIR MAXIMUM PER SAWCUT. O EXTEND SAWCUT SUFFICIENT LENGTH TO PROVIDE FULL SAWCUT DEPTH AROUND CORNERS. O WEARING COURSE (LOOPS SHALL BE INSTALLED PRIOR TO FINAL LIFT IF NEW PAVEMENT IS INSTALLED) WHERE APPLICABLE. O FILL WITH SEALANT. REVISION z N 0.25" MINIMUM WIDTH SAWCUT SECTION A —A CENTER OF LANE STOP BAR 12" 7T A. .A 14' (rn'•) TO ADDITIONAL LOOPS WHERE APPLICABLE z = X � Q N M 0.50" MINIMUM WIDTH SAWCUT SECTION 3 -13 SEE NOTE 6 T_ g (Tm.) C -dK- TO ADDIRON AL LOOPS WHt?tE APPLICABLE A\ A ROUND LOOP SEE LOOP SAWCUT SAWCUT DETAIL (TYP.) EDGE OF PAVED SHOULDER C FOR CONDUIT STUBOUT LOCATION SEE LOOP STUB OUT CONDUIT PLACEMENT DETAILS JUNCTION BOX D D 1* SPLICES B B C p C_ I D B SPLICES, SEE LOOP WINDING DETAIL L FOR CONDUIT STUBOUT IF LOCATION SEE LOOP STUB A OUT CONDUIT PLACEMENT DETAILS TYPE R3 INDUCTION LOOP T-302 OOD sua� EuBARGHAUSEN C.E. sc Exnc._ ".w ,see N.T.S. NORRON N NND ,seai,�, DESICNm: WHL Dw�wN: MJP /MPJ /JRM '_­ DATUM WHL I �r FULL i IF NOT ONE E IK INCH BY DATE APPR opna� S ""IXiDWN Y REJ LEAD -IN TO ROUND LOO' SAWCUT 45` 1° LU(JP SAWCUT DETAIL TO ADDITIONAL LOOPS WHERE APPLICABLE CENTER OF LANE C B B 1 6' A A TYPE R1 INDUCTION LOOP FULL DEPTH SAWCUT MATCH EXISTING MATERIAL 3° CRUSHED SURFACING TOP COURSE (WHERE SAWCUTTING IS REQUIRED) U') N SAND N r7 CONDUIT W I W = CONDUIT DIAMETER Imo— PLUS 2" 0.50" MINIMUM APPLICABLE IN IMPROVED AREAS WIDTH SAWCUT WHERE SAWCUTTING IS NECESSARY BETWEEN CONDUIT STUBOUT AND SEC -90N C —C ASSOCIATED JUNCTION BOX. SEE NOTE 6 SECTION D —D APPROVED APPROVED BVA'A�_ DATE > BY DATE/ &2 AM CITY OF SAM'S CLUB #4835 -00 ^ ^ REN TON 901 SOUTH GRADY WAY �. Planning /Buildino /Public Works Dept. RENTON, WA 98055 ROUND LOOP DETAILS SCANNED OCT 0 8 Z FR 1 6 - N 3/14/03 FE,D"DdL P14E TS -7 q 1144 Eastlake Ave. E. T (206) 522 -9510 Suite 601 F (206) 522 -8344 Seattle, WA 98109 www.PAcLAND.coN yaso JUNCTION BOX E. �¢ OF AS d� ` � 5 92784 p UST NO LOOP INSTALLATION NOTES 1. INSTALL JUNCTION BOX AND LEAD -IN CONDUIT. 2. SAWCUT LOOP SLOTS AND LEAD -IN SLOTS. 3. LAY OUT LOOP WIRE STARTING AT JUNCTION BOX, ALLOWING 5' MINIMUM SLACK. 4. INSTALL WIRE IN LOOP SLOT AS SHOWN. 5. FINISH LAYING OUT WIRE AT JUNCTION BOX AND IDENTIFY LEADS WIT,H LOOP NUMBER AND "S" FOR START AND "F" FOR FINISH. 6. TWIST EACH PAIR OF LEAD WIRES TWO TIMES PER FOOT FROM ! G; ;P TO JUNCTION BOX. REVERSE DIRECTION OF TWIST FOR EACH SUCCESSIVE PAIR INSTALLED. 7. CONSTRUCT SUPPLEMENTAL SPLICE CONTAINING ANY - SERIES `OR PARALLEL LOOP CONNECTIONS REQUIRED IN PLANS. SUPPLEMENTAL SPLICES ARE SUBJECT TO THE SAME REQUIREMENTS SHOWN FOR THE LOOP LEAD AND SHIELDED CABLE SPLICE. 8. SPLICE LOOP LEADS OR SUPPLEMENTAL SPLICE :TADS 'TO SHIELDED CABLE AS NOTED IN THE PLANS.' 9. COMPLETE INSTALLATION AND TEST LOOP CIRCUnS'OR COMBINATION LOOP CIRCUITS. SEE STANDARD SPECIFICATION 8- 20.3(14)D. 10. FRONT OF LOOP SHALL BE MEASURED FROM BACK OF STOP BAR, OR BACK OF CROSSWALK WHERE NO STOP BAR IS-INSTALLED. 11. CONDUIT FOR LOOP STUBOUT SHALL BE SCHEDULE 40 PVC. 12. LABEL ALL LOOP LEAD IN WIRES WITH BOTH LOOP NUMBER AND LOOP SERIES NUMBER ON T7VE R3 LOOPS AS SHOWN BELOW. LOOP LEAD IN WIRE LABEL: LnXX —XX LOOP NUMBER LOOP SERIES NUMBER DASH S OR F TO CONTROLLER tOSEALANT TO ENCAPSULATE CONDUCTORS — SEE SPECIAL PROVISIONS. 2� LOOP WIRE — #14 AWG. O LEAD —IN WIRES: (SEE INSTALLATION NOTES) THREE PAIR MAXIMUM PER SAWCUT. O EXTEND SAWCUT SUFFICIENT LENGTH TO PROVIDE FULL SAWCUT DEPTH AROUND CORNERS. O WEARING COURSE (LOOPS SHALL BE INSTALLED PRIOR TO FINAL LIFT IF NEW PAVEMENT IS INSTALLED) WHERE APPLICABLE. O FILL WITH SEALANT. REVISION z N 0.25" MINIMUM WIDTH SAWCUT SECTION A —A CENTER OF LANE STOP BAR 12" 7T A. .A 14' (rn'•) TO ADDITIONAL LOOPS WHERE APPLICABLE z = X � Q N M 0.50" MINIMUM WIDTH SAWCUT SECTION 3 -13 SEE NOTE 6 T_ g (Tm.) C -dK- TO ADDIRON AL LOOPS WHt?tE APPLICABLE A\ A ROUND LOOP SEE LOOP SAWCUT SAWCUT DETAIL (TYP.) EDGE OF PAVED SHOULDER C FOR CONDUIT STUBOUT LOCATION SEE LOOP STUB OUT CONDUIT PLACEMENT DETAILS JUNCTION BOX D D 1* SPLICES B B C p C_ I D B SPLICES, SEE LOOP WINDING DETAIL L FOR CONDUIT STUBOUT IF LOCATION SEE LOOP STUB A OUT CONDUIT PLACEMENT DETAILS TYPE R3 INDUCTION LOOP T-302 OOD sua� EuBARGHAUSEN C.E. sc Exnc._ ".w ,see N.T.S. NORRON N NND ,seai,�, DESICNm: WHL Dw�wN: MJP /MPJ /JRM '_­ DATUM WHL I �r FULL i IF NOT ONE E IK INCH BY DATE APPR opna� S ""IXiDWN Y REJ LEAD -IN TO ROUND LOO' SAWCUT 45` 1° LU(JP SAWCUT DETAIL TO ADDITIONAL LOOPS WHERE APPLICABLE CENTER OF LANE C B B 1 6' A A TYPE R1 INDUCTION LOOP FULL DEPTH SAWCUT MATCH EXISTING MATERIAL 3° CRUSHED SURFACING TOP COURSE (WHERE SAWCUTTING IS REQUIRED) U') N SAND N r7 CONDUIT W I W = CONDUIT DIAMETER Imo— PLUS 2" 0.50" MINIMUM APPLICABLE IN IMPROVED AREAS WIDTH SAWCUT WHERE SAWCUTTING IS NECESSARY BETWEEN CONDUIT STUBOUT AND SEC -90N C —C ASSOCIATED JUNCTION BOX. SEE NOTE 6 SECTION D —D APPROVED APPROVED BVA'A�_ DATE > BY DATE/ &2 AM CITY OF SAM'S CLUB #4835 -00 ^ ^ REN TON 901 SOUTH GRADY WAY �. Planning /Buildino /Public Works Dept. RENTON, WA 98055 ROUND LOOP DETAILS SCANNED OCT 0 8 Z FR 1 6 - N 3/14/03 FE,D"DdL P14E TS -7 q